| 1 | CREATION OF 25KVA SUBSTATION ALONG WITH HT/LT NETWORK FOR MULTIFUNCTIONAL COMMON FACILITATION CENTRE AT SAIM SMITH RAJOURI. |
| 2 | SITC OF HT Line |
| 3 | S.T Pole 9 mtrs long (410-SP33) |
| 4 | Galvanisied V cross-arm with top bracket including clamp |
| 5 | GalvanisiedChannel cross-armt including clamps and braces. |
| 6 | 30 mm2 ACSR Weasel Conductor |
| 7 | PG clamp for 30 mm2 ACSR Weasel Conductor |
| 8 | 11 kv Pin insulators with pins (10KN) |
| 9 | 11 kv Disc insulators with fittings (45 KN) |
| 10 | Galvansied Stay set with 50x8mm stay clamp, guy insulator (02nos.) anchor plate (200x200x6mm) nut bolts, 2nos. Turn bukles, 1.8m long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 11 | Al. Painting |
| 12 | Red Oxide |
| 13 | Anti Climbing Device with clamps |
| 14 | Danger Plates with clamps |
| 15 | Galvansied Nuts and Bolts of sorts |
| 16 | SITC OF 11/0.44 kV S/Station |
| 17 | 25KVA Transformer Level II , 11/0.433KV,3-Phase Distribution Transformer with Bimetallic Terminal Connectors ,Almunium Wound and with LV Cable Box having detachable Aluminium Gland plate. |
| 18 | S.T Pole 9 mtrs long (410-SP33) |
| 19 | Surge Arrester Station Type 9KV, 10 kA (Polymer Type) |
| 20 | 11 KV Horn Gap Set, 3 Phase, 200 Amp |
| 21 | 11 KV GO, AB Switch 3-Phase ,3-pole, 200 Amp, Vertical Type |
| 22 | Channel/Flate/Angle in shape of fabricated X-arms, Top bracket, Angle braces, clamps etc. |
| 23 | GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete. |
| 24 | wedge connector/PG clamp |
| 25 | PVC insulated stranded conductor FRLS type 1.1kv Grade Cable 185mm sq with Thimbles |
| 26 | 11 kv Pin insulators with pins (10KN) |
| 27 | 11 kv Disc insulators with fittings (45 KN) |
| 28 | Nuts and Bolts of sorts |
| 29 | Earthing of Sub-station ,excavation of earth pit of dia 650mm and depth 3000mm,installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5 mtr.long as per IS 1239.GI strip for neutrl earthing of size 25 mm*3 mm for connection of transformer body ,G.O set and lightening arrestor as per IS 2629/85,GI nuts and bolts ,refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.(Specification as per cost data) |
| 30 | Cemment Bottoming 1:2:4 mix as per REC standard 0.5 cubic mtr per poles |
| 31 | 3-Phase Trivector Meter with CT. |
| 32 | GI BARBED WIRE FOR Anti Climbing |
| 33 | Danger Plate |
| 34 | Al. Painting |
| 35 | Red Oxide |
| 36 | Sundry Items/POL |
| 37 | SITC OF LT Line |
| 38 | S.T Pole 8 mtrs long (410-SP15) |
| 39 | 30 mm2 ACSR Weasel Conductor |
| 40 | Shakle Insulator (16KN) |
| 41 | Mukky Clamps |
| 42 | Cemment Bottoming 1:2:4 mix as per REC standard 0.45 cubic mtr per poles |
| 43 | Galvansied Stay set with 50x8mm stay clamp, guy insulator (02nos.) anchor plate (200x200x6mm) nut bolts, 2nos. Turn bukles, 1.80m long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 44 | Earthing Complete by G.I. Pipe 40mm or G.I. Rod 20mm 2.5mtr long through G.I. Strip |
| 45 | Anti Climbing Device with clamps |
| 46 | Red Oxide |
| 47 | Al. Painting |
| 48 | LT line spacer |
| 49 | Danger Plate |
| 50 | Nuts and Bolts of sorts |
| 51 | Providing of computriised single diagram of the complete work depicting all vital items including landmark (size of sheet 24X24 inch) |
| 52 | installation of sign board of dimensions (2*3) sq. ft depicting name of the work ,scheme and executing agency along with name of the contractor with legs of 3 feet height embedded in cement concrete |
| 53 | Providing of geo tagged coloured photographs of all the vital items of the work including name plate of Transformer(size of photograph 4X6 inch) Please Enable Macros to View BoQ information |