| 1 | Dismantling old plaster / skirting carefully , raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 100 m lead |
| 2 | Dismantling C.I pipes of following dia in shafts / open piping including taking out the pipes manually, breaking lead caulked joints, melting of lead, making into blocks including stacking of pipes within a lead of 200 m as per direction of Engineer-in-charge |
| 3 | 75 mm Dia C. I pipe |
| 4 | 100 mm Dia C. I pipe |
| 5 | Removing white or colour wash, distemper, external paint by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete all as directed at site including scaffolding, cleaning of the areas. |
| 6 | Providing 20 mm thick plastering using Ready mix external plastering compound of approved make for external faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete.all as per specifications including forming drip moulds wherever necessary and as directed by the Engineer-in-charge |
| 7 | Providing 15 mm thick plastering using Ready mix internal plastering compound of approved make for internal faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning, scaffolding complete all as per specifications and as directed at site by the Engineer-in-charge.Note: Actual Areas will be measured |
| 8 | Providing structural repairs in old damaged concrete structures / surfaces with approved Polymer with following operations 1) Removal of loose/Spalled or damaged concrete by chipping and cleaning the concrete surface and reinforcement steel with wire brush and with water 2) Cleaning the re bars with Acetone for complete rust removal and washing with water to make the surface clean. 3) Applying protective coat / bond coat using polymer and cement in the proportion of 1; 1.5 (1 part of polymer and 1.5 parts of cement in synthetic enamal paint like consistancy with brush 4) Reinstate the area with polymer modified mortar in layers of maximum 20 mm with the proportion of Cement 50 Kg : washed and Quartz sand 87.50 kg ; silica sand 37.50 Kg. mixed with 10 litres of Polymer (or 1 Kg cement : 1.75 kg Quartz sand ; 0.75 Kg silica sand : 200 ml polymer)5) If thickness of repair exceeds 20mm , after every 20 mm thick repair, bond coat as per 2 above to be applied and further thick of repair to be continued for each layer. This work is inclusive of all materials, labour, complete all as directed at site using approved polymer suitable for structural repair shall be used). Note: Scaffolding will be paid separately under relevant item & documentry evidence i.e purchasing of materials/tax invoices are to be submitted. |
| 9 | Providing SFMC Micro concrete for strengthening of structural members including mixing, pouring, curing as per manufacturer specifications and as directed by the Engineer-in-charge Using 100% SFMC |
| 10 | Providing and fixing double tubular scaffolding system using H - frames with cup lock type on the exterior side upto seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in - charge. The elevational area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding |
| 11 | Providing Reinforcement Steel for reinforced cement concrete atall levels including supplying, preparation of bar bendingschedules, cutting, bending, transporting, fixing, tieing inposition with PVC coated G.I binding wire, all labour charges,cost of cover blocks in specified grade of concrete etc. completeas per specifications and drawings. Steel supplied by thecontractor. Using TMT bars of Fe-500D grade of all sizes .TMTbars to be supplied by the contractor shall conform to IS – 1786(Latest edition) and BARC specification Note: 1) The contractorshall supply documentary evidence of purchase of steel, Testcertificate from approved manufacturers and also testing thirdparty from approved laboratories without any extra cost. 2)Binding wire required for the work will have to be supplied bythe contractor at their own cost and will not be measured forpayment. 3) Cover blocks shall be of same grade of concrete. |
| 12 | Providing & applying Synthetic plaster / TexturedCoating with finishes of minimum 2 mm thicknessbased on synthetic fibre & chemicals having acid,alkalies, fire & fungus resistance properties ofapproved shade &type on plastered surface/ concretesurface at all levels in the same pattern of faciablocks with grooves, bands for different offsets indifferent colours as per approved sample includingrequired cost of Steel Double scaffolding. The itemshall include applying synthetic plaster with onebase coat by trowelling followed by 3 coats offinished paint by brush supplied by samemanufacturer, providing decorative finish asrequired including preperation of plastered surfaceto receive plaster cleaning the surface including costof scaffolding and cost of all materials, labour etccomplete as per manufacturers specifications and asdirected by Engineer. |
| 13 | On Plain plastered / concrete sufaces |
| 14 | Providing and painting walls with (Two coats) of approved shade of high build protective, elastomeric water proof exterior grade paint of approved make of required shade, minimium dry film thickness of 250 microns acheived in two or more coats / as per manudacturer's specifications including preparation of the surfaces by scrapping / wire brush, scaffolding complete. Primer coat will be with approved make with water in ratio of 1:2 and 2 coats of finishing coat without water all as directed by Engineer-in-charge. |
| 15 | Providing and fixing G.I. chicken mesh in the junctions of concrete & brick work / masonry or as directed by the Engineer in charge including cutting, fixing with nails in position before plastering complete all as directed by the Engineer-in-charge. (only area of the chicken mesh used alone will be measured) |
| 16 | Carrying out core cutting beyond 50 mm up to and including 100 mm Dia. size in RCC slab at various levels using Non Vibrational core drilling machine attached with circular Diamond cutting core bit as required at site & as per instruction of Engineer-in-Charge including labour, material, machine, consumable tools & tackles etc. with safety precaution etc. complete. Breaking of brick bat coba and plaster will measured and paid in relevant item |
| 17 | Supplying , cutting to shape and fixing specified diameter UPVC pipes as per IS 4985 in RR Masonry/ RCC walls for weep holes complete all as per drawings and as specified at site. |
| 18 | 90 mm dia UPVC Pipes |
| 19 | Providing and applying one coat of cement primer of approved brand on wall surface to receive specified paint including scaffolding complete all as per specifications and as directed by Engineer-in-charge |
| 20 | Providing and applying white cement based wall putty of approved make over concrete or Plastered surface up to 3 mm thick to get uniform surface free from undulation including cleaning complete all as directed by the Engineer-in-charge |
| 21 | Providing, applying wall painting two coats with Lustre finish paint of approved brand to give an even shade over a coat of cement primer including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge |
| 22 | Providing, applying wall painting two coats on new work with premium plastic emulsion paint of approved brand to give an even shade without cement primer.including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge. Note : Internal painting to be carried out in occupied areas may involve restricted working condition viz taking up painting work according to users convenince and as and when areas are made available in phase manner, shifting / covering of furniture /equipment/smoke detecter /electrical fittings etc. |
| 23 | Providing and Painting two coats of synthetic enamel paint on steel surfaces of approved brand and manufacture to give an even shade over a primer coat.including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge |
| 24 | Providing and painting TWO coats of synthetic enamel paint on new wooden surfaces of approved brand and manufacturer of required colour to give an even shade over an under coat of suitable shade primer of approved brand and manufacturer including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge |
| 25 | Filling the gap between aluminium frame & adjacentRCC / Brickwork / Stone work by providing weathersilicon sealant of approved quality as per architecturaldrawings and directionof Engineer-in-charge complete Upto 5 mm depth and 5 mm width. |
| 26 | Providing and Fixing Homogeneous 2.00 mm thick PVC sheet / tile in flooring and skirting of approved make in approved pattern on a smooth and damp proof base using rubber based adhesive of approved quality and manufacturer including, levelling small undulations with plasterof paris if required , rolling with light wooden roller weighing about 5 kg all complete as directed by Engineer-in-charge in approved colour and shade. Note : Rate shall be included removing of existing flooring (if any). |
| 27 | Providing, supplying, fixing in position, under floors or in walls centrifugally cast iron pipes including required specials like bends, tees, 'Y' collars, cowl etc for soil, waste and ventilation pipes conforming to IS.3989 or Cast Iron hubless pipes confirming to IS 15905 of approved make or approved equivalent product/quality meeting technical specifications including cost of jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes, painting with primer, fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site. |
| 28 | 75 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 0.90 kg lead / joint or Cast Iron hubless pipes confirming to IS 15905 |
| 29 | 100 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 1.00 kg lead / joint or Cast Iron hubless pipes confirming to IS 15905 |
| 30 | Providing, supplying and fixing Vertical /Roller Venetian Blinds with all accessories and fabricating to required sizes etc as per approved design and approved Fabric complete all as directed by the Project Engineer. Note : Size of windows opening will be considered for payment. |
| 31 | Supplying of Unskilled man power / labour for loading / unloading, area cleaning and miscworks. etc. including cost of equipement whichever is required at site. |
| 32 | Lead charges for lead Exceeding 2 KM but not exceeding 3 KM, by mechanical transport including loading, unloading, stacking / levelling etc. |
| 33 | Debris Beyond 2 Km but up to and including 3 kmNote: The rates in respect of Item Nos are applicable for NET Quantities arrived at after making deduction for voids @ 30% from corresponding TRUCK Measurement |
| 34 | Providing and Fixing in position Suspended false ceiling system using 600 x 600mm Calcium Silicate Ceiling tiles having 15mm densified edges and 100% humidity resistance, incombustible as per BS476 part IV with thermal conductivity of 0.043 w/m KC and approvred surface design and edge profile placed in a suspended grid of size of 600 x 600mm made of hot-dipped G.I steel sections having an exposed surface capping of pre-finished baked polyester painted coil wherein the main tee of size 24mm x 38mm x 0.33mm shall be suspended at 1200 mm centres along the length of ceiling with 4mm dia G.I wire with necessary level adjusters and cross tees of size 24 x 28 x 0.33mm x 1200 mm shall be inserted in to slots between the main tees at 600mm centres and thereafter in direction vertical to the longer tees, cross tees of size 24 x 28 x 0.33mm x 600mm shall be inserted to form a grid size of 600 x 600 mm resting on the perifery walls on wall angles of size 20mm x 20mm x 3000 mm x 0.40 mm thickness. The rate shall include providing necessary openings for light fixtures, diffusers, trap doors etc to be made as per layout drawings. The work shall be carried out as per directions of Engineer-in-charge. The main tees to be suspended from the ceiling/ soffit with the help of matal dash fastners of 6mmx50mm, soffit clits of 25mmx35mmx1.60mm and 4mm dia G.I wire with galvanised spring steel levelling clips. the entire grid system shall be designed to bear a distributed load of minimum 15 kg/Sq.m (Only calcium silicate false ceiling area will be measured for the purpose of payment |
| 35 | Providing , centering ,shuttering Form work using PVC film faced plywood to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels in super structure. Please Enable Macros to View BoQ information |