| 1 | Cutting in earth work and disposal of all excavated earth with in all leads and lifts complete to the entire satisfaction as directed by the Engineer-in-charge . |
| 2 | Excavation in foundations,trenches etc., in earth work, lift upto 1.50 mts. Stacking the excavated soil not more than 3 mts. Clear from the edge of the excavation & then returning the stacked soil in 15 cms. Layers,when required into plinths sides of foundation etc.,consolidating each deposited layers by ramming & watering & then disposing of all surplus excavated earth as dierected within all leads & lifts as per entire satisfaction of Engineer in charge. |
| 3 | Providing & laying cement concrete 1:3:6 (1cement : 3 sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring & shuttering in Foundation & plinth. |
| 4 | Providing & laying design mix M-30 but not less than cement concrete 1 : 1.5 : 3 (1cement : 1.5 sand : 3 graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work & reinforcement for reinforced concrete work in :- |
| 5 | Foundation,footing,bases of columns and the like & mass concrete. |
| 6 | Wall (any thickness but not less than 0.10 mts.Thickness)attached pillasters,buttresses plinth,& string courses etc.from top of found.level upto floor two level |
| 7 | Suspended floor,roofs,landing & shelves & their support balconies,beams,girders,bressumers & cantilever upto floor level. |
| 8 | Prov.form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm,so as to give a fair finish i/c centring shuttering,strutting & propping etc. with wooden battens & ballies,ht. of propping & centring below supporting floor to ceiling not exceeding 4.00 mts. & removal of the same for in situ-reinforced concrete & plain concrete work :- |
| 9 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors etc. above 200mm. In thickness with in all leads & lifts & to the entire satisfaction of Engineer-in-Charge. |
| 10 | Vertical surfaces such as wall (any thick.) partitions & the like i/c attached pillasters,buttresses,plinth & string courses & the like. |
| 11 | Prov.in RCC work smooth finishing of the exposed surface with cement mortor1:3(1cement :3 sand ) |
| 12 | Providing Tor steel reinforcement for RCC work i/c bending,binding & placing complete upto floor two level within all leads and lifts complete to the entire satisfaction as directed by the Engineer-in-charge of the site of work |
| 13 | Steel work welded in built up sections,trusses & framed work i/c cutting,hoisting & fixing in position & applying a priming coatof red paint :- In grating, framed ,guards,bars, ladders,railing,brackets & similar works. |
| 14 | Prov. & fixing SFRC Man hole cover with frame having frames size of 560 mm internal dia.should not be less than 100 kg within all leads and lifts complete to the entire satisfaction as directed by the Engineer-in-charge of the site of work Please Enable Macros to View BoQ information |