| Sl. No. | Item Description |
| 1 | Earthwork in excavation (As per I.S 3114 /1965 for laying of different types and sizes of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineer-in-Charge |
| 2 | Total Excavation in all type of Soil strata |
| 3 | For Classification of Soil Item -A (Excavation in Soft Strata) -50 % |
| 4 | For Classification of Soil Item -B (Excavation in Hard Strata) - 35 % |
| 5 | E/W in excavation of cut-off trenches by the hydraulic excavator as per designed section in soft rock (Where blasting is not needed) (vide type of soil item -C) with disposal of soil beyond 1/2 km from centre of trench but upto 1 km with all lifts by tipper including construction and maintenanceof haul road all complete as per specification & direction of E/I . |
| 6 | Excavation in Hard Strata (15% of Total Earth) |
| 7 | Earthwork in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts, evelling , ramming the foundation trenches, removing roots of trees , surbs all complete as per approved design, building specification and direction of E/I. |
| 8 | E/W in excavation in foundation trenches in ordinary soil (vide classification of soil item - A) and disposal of excavated earth obtained to a distance upto 50 M including all lift leveling, ramming the foundation trenches removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I. |
| 9 | Excavation for structures (earthwork in excavation of foundation of structures as per drawing and technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for roadwork.) |
| 10 | Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 m and lift of 1.5 m all complete as per building specification and direction of E/I |
| 11 | Earthwork in back filling the trenches after laying different types and sizes of pipes with earth removed during excavation within initial lead and lift as per specification and design of Engineer -in- charge (for classification of soil item A & B ) |
| 12 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I (mode of measurement compacted volume) |
| 13 | Dewatering |
| 14 | Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A- 9/261) |
| 15 | RCC/PCC |
| 16 | Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of store chips 20 mm-6 mm size graded and clean coarsed sand of FM 2.5 to 3.0 including screeing shuttering mixing cement concrete in mixer and placing in position vibrating striking curing taxes and royalty all complete as per building specification and directio of E/I |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) :3 graded stone aggregate 20 mm nominal size). |
| 18 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to(1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size) |
| 19 | REINFORCEMENT |
| 20 | Providing Tor steel reinforcement of 8 mm, 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carrriage of MS bars to work site. Including cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 21 | Mild Steel Bars |
| 22 | Road Cutting and Road Restoring |
| 23 | Supplying tools and cutting road as well restoring the same as per specification and direction of E/I. |
| 24 | Pucca Road (Except black top only taken out material to be used) for cutting road as per requirement. |
| 25 | Water bound macadam road (taken out material will be used) for cutting road as per requirement and making good the same. |
| 26 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15 meter lead and disposal of un-serviceable materials with all leads all complete as per direction of E/I |
| 27 | Plaster |
| 28 | Providing 12 mm thick cement plaster (1:6) with clean coarse sand of FM 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I. |
| 29 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding, taxes & royalty all complete as per building specification & direction of E/I. |
| 30 | Providing 12 mm. cement plaster (1:3) with clean coarse sand of F.M. 1.5 and 1.5mm cement punning including screening, curing wit taxes and royalty all complete as per building specification & direction of E/I. |
| 31 | Providing 1.5 mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I |
| 32 | Brickwork |
| 33 | Providing designation 75A brickwork in C.M. (1:6) in superstructure with approved quality of clear coarse sand of FM 2 to 2.5 including providing 10 mm thick mortar joints cost of screening, materials, scaffolding, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 34 | Providing designation 75A one brick flat soling joint filled with local sand including cost of watering taxes royalty all complete as per.building specification and direction of E/I |
| 35 | Providing designation 75B one brick flat soiling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of Engineer |
| 36 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening, materials, scaffolding, raking out joints to 15 mm depth curing, taxes & royalty all complete as per building specification & direction of E/I. |
| 37 | FLOATING INTAKE |
| 38 | Design ServicesDesign, IRS/IIT Vetting of Pontoon for 2 nos of Horizontal split case Pump set |
| 39 | Metallic PontoonPontoon is suitable for 2 nos. of HSCF pumps sets having below duty points(Flow - 116 LPS = 417 m3/hrHead- 50 mtr Motor - 130 KW/ 150 HPPump Type - HSCFPump Qty - 2 pump 1.Pontoon Size- 10 x 6 mtr approx.2.Pontoon lifting lugs3.Chain pulley with trolley of 3T capacity.4.Supporting structure for chain pulley5.Safety Railing6.Anti-skidding top surface7.MOC for pontoon– MS IS 2062 Grade – Br E2508.Exterior pontoon surface painting -PU paint, Inside Paint– Red oxide9.Hardware - SS30410. Covering shed on metallic pontoon |
| 40 | Anchoring and Mooring for PontoonAnchoring and mooring for pontoon as per Marine Statutory Rules and approvals, necessary bollards, RCC anchors with suitable weight and size, marine chain with suitable size dia. and length |
| 41 | Floating Walkway Metallic1.Size - length 1 x width 3 mtr2.MOC -MS IS 20623.Safety railing4.Anti-skidding top surface5.surface painting - PU Coating |
| 42 | Anchoring and MooringAnchoring and mooring for walkway per Marine Statutory Rules and approvals, necessary bollards, RCC anchors with suitable weight and size, marine chain with suitable size dia. and length |
| 43 | HeaderHeader on pontoon Header pipe size - 400 mm dia., 6 mtr long 2 nos of inlet pipe -300 DN Dia and 1 nos of outlet -300 mm dia. along with flanges, hardware and gasket |
| 44 | HDPE Pipe 300 DNMOC - HDPESize - 300 DNwelded with 2 stud ends and 2 MS slip flanges inserted. UV stabilized raw material.Length - 6 mtr |
| 45 | SS Flexible pipe 300 DNSize - 300 mm dia.MOC - SSLength - 6 mtrSingle braided with both side Flanges |
| 46 | Safety Equipments1.Life Jackets2.Life Buoys3.Fire Extinguisher4.Automatic/ non automatic bilge Pump |
| 47 | RWRM , CWRM |
| 48 | Providing and supplying ISI mark centrifugally cast (spun) ductile iron pipes of 100 mm and above all diameter for water works with socket and spigot ends confirming to IS.8329/2000 in standard working lengths of 4.5, 5.5 & 6.0 m for classification K-9 suitable for push on joint (Rubber gasket D jointing) with cement mortar lining on inside surface with outside zinc and bituminous coating. |
| 49 | 250 mm Dia |
| 50 | 400 mm Dia |
| 51 | 450 mm Dia |
| 52 | Providing, supplying ISI standard D.I. specials & fitting with sealing rubber gasket of S.B.R. complete with cast iron follower gland and M.S. nut & bolts coated or otherwise protected from rusting and suitable for D.I. pipes including all taxes etc. complete as per IS 9523 class K-12 9 ex - factory).Socketed |
| 53 | 100-300 mm dia |
| 54 | 350 - 450 mm dia |
| 55 | Supplying labours, tool and tackles for testing of laid CI or UPVC or HDPE or AC or DI pressure pipe all complete as per specification direction E/I |
| 56 | 250 mm Dia |
| 57 | 400 mm dia |
| 58 | 450 mm Dia |
| 59 | Labour charge for one cutting of cast iron/DI pipe & specials including supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I. |
| 60 | 250 mm Dia |
| 61 | 400 mm dia |
| 62 | 450 mm Dia |
| 63 | Manufacturing, providing and supplying spirally welded/ ERW/ SAW / fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible). |
| 64 | Dia of Pipe : 500.00 mm (I.D.) & Thickness of Pipe : 9.00 mm |
| 65 | Lowering, laying in position to correct line and level including M. S. pipes with / without any outcoating on pedestals or chairs upon prepared formation. The rate to include loading, unloading, hoisting, marginal cutting wherever required, assembling and tack welding, and transportation upto 500 M. etc. completed as specified. |
| 66 | 5 mm to 8 mm thick & Above 250 mm. Upto 500 mm. dia |
| 67 | Providing double flange sluice valve (50 mm to 1200 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete.Without bypass arrangement - P.N - 1.6 |
| 68 | 100 mm Dia |
| 69 | 150 mm dia |
| 70 | 450 mm Dia |
| 71 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. |
| 72 | 100 mm Dia |
| 73 | 150 mm dia |
| 74 | 450 mm Dia |
| 75 | Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores in all respect etc. complete. Kinetic Air Valve Flanged Type - PN -1.6 |
| 76 | 150 mm Dia |
| 77 | Lowering, laying and fixing in properalignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves) Air Valve Double Ball (PN-1 and PN - 1.6) |
| 78 | 150 mm Dia |
| 79 | Providing and fixing in position and jointing high performance C. I. Air valves for water combination type ( Kinetic air valve along with automatic air valves ) double ball, double orifice with stainless steel ball, tamper proof air vents rolling seal mechanism for air release and anti vacuum application designed for 16 Kg. Per sq. cm. working pressure and tested for 20 for kg per sq. cm. pressure. Rate to include cost of gaskets, bolt, nut and any other material required for jointing and its transportation etc. in all respect.C.I. ARV FLFF PN 1.6 150mm Dia. (Vacuum Air Breaker Valve) |
| 80 | Providing double flange sluice valve (50 mm to 1100 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete.Without bypass arrangement PN-1.6 |
| 81 | Scour Valve |
| 82 | 150 mm |
| 83 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. |
| 84 | Scour Valve |
| 85 | 150 mm |
| 86 | Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking in all respect etc. excluding C.C. foundation/structural steel support.Butterfly valve - PN - 1.6 (With by pass arrangement)450 mm dia |
| 87 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. |
| 88 | Butterfly valve |
| 89 | 450 mm dia |
| 90 | Supplying labours, tools, tackles, lubricant etc. for laying and jointing DI/C.I.S/S Tyton pipes (class LA) trenches supplying rubber gasket (Rubber gaskets confirming to I.S.S.-5382-1969) and taking gasket joints including providing night guard, barrier and red light to safe guard against accident, all complete , laying of pipes is to be done as per (I.S.S. 3114 -1985) as per design, specification and direction of E/I. |
| 91 | 250 mm Dia |
| 92 | 400 mm Dia |
| 93 | 450 mm Dia |
| 94 | Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking in all respect etc. excluding C.C. foundation /structural steel support.Butterfly valve - PN - 1.6 (With by pass arrangement) |
| 95 | 250 mm Dia |
| 96 | 400 mm Dia |
| 97 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. |
| 98 | Butterfly Valve |
| 99 | 250 mm Dia |
| 100 | 400 mm Dia |
| 101 | Providing double flange sluice valve (50 mm to 1100 mmmm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete.Without bypass arrangement PN-1.6 Sluice Valve |
| 102 | 400 mm Dia |
| 103 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.(Rate for all class of valves.). |
| 104 | Sluice Valve |
| 105 | 400 mm |
| 106 | Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications having small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring,with built-in Kinetic features, isolating sluice valve mounted in horizontal position and operated by wheel gearing, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, in all respect etc. complete.b) Kinetic Air Valve Flanged Type - PN -1.6 |
| 107 | 100 mm |
| 108 | 150 mm |
| 109 | Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves)c) Kinetic Air Valve (PN-1 and PN - 1.6) |
| 110 | 100 mm |
| 111 | 150 mm |
| 112 | Providing, lowering, laying, aligning, fixing in position jointing in pipeline following dia D/F DI Plunger valve (Flow Control Valve) PN 1.6 class with electrical actuator suitable for SCADA compatibility complete (including jointing & jointing material) including all material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer.High Altitude Values |
| 113 | 250 mm Dia |
| 114 | 400 mm Dia |
| 115 | Full-Bore Electromagnetic Flow Meter:Supply, install and commission Electromagnetic Flow Meter (EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/-0.5% of measured value & protection as per given specifications for size 100 mm-1000mm including sensor, transmitter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications. |
| 116 | 250 mm Nominal Dia Flowmeter |
| 117 | 400 mm Nominal Dia Flowmeter |
| 118 | 450 mm Nominal Dia Flowmeter |
| 119 | Water Treatment Plant - 10 MLD |
| 120 | Designing (aesthetically ), providing constructing and commissioning Conventional Water Treatment Plant consisting of all Civil, Mechanical and Electrical works including cost of providing and applying epoxy paint to inside surface of water retaining structures in contact with chlorine and providing antitermite treatment to entire structure below ground level, mechanical and electrical components of various sub-works as given below, including necessary hydraulic testing, structural testing, equipment testing and trial run for a period of 3 months, etc. complete as directed by Engineer-in-charge (turn-key job). |
| 121 | Aeration Fountain- Plan are a not less than 0.625 square metre per MLD |
| 122 | Ventury Flume - With necessary devices, consisting of simple mechanical indicator. (Pedestal type gauge) |
| 123 | Flash Mixer-Rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec -1, vane mixer type conforming to I.S. 7090 of 1985. |
| 124 | Flocculator – Conforming to I.S.7208-1974 (Type-C) with detention period of 30 minutes. |
| 125 | Clarifier - Horizontal flow circular tank, detention period 2-5 hours, overflow rate 30 cubic metre per square metre per day (to be specified), Weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to I.S. No. 10313-1982. with necessary inlet arrangements. |
| 126 | Rapid Sand Filter sand Filter House-Filter designed for filteration rate of 5,000 litres per square metre per hour, minimum 2 beds for plant upto 10 MLD, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width with constant rate filtration or declining rate filtration. |
| 127 | FilterSand-Effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75M, free board 50cm, gravel 0.45M in depth, sand and gravel conforming to I.S. 8491 (i)-77, back wash by air wash, standard appurtenances (to be specified), rate of flow controller, filter gauge, sand expansion gauge, etc. |
| 128 | Wash Water Tank-Capacity to be specified and suitable to supply water to wash specified number of filter beds at a time 12 minutes @ 600 lit/sqm/min. under a head of 12 m at under drain. |
| 129 | Wash Water Pumps- Capacity to fill water tank in 1 hour with 100% standby. |
| 130 | Air Blowers-Capable of delivering 600 LMP per square metre of free air, of filter area at 0.4kg / sq.cm at the under drains (100% stand by) for period of 5 min. |
| 131 | Chemical House in Two Storeys |
| 132 | Ground floor to accommodate 7 days' alum requirement and sundry storage. (Minimum 4 m height) |
| 133 | First floor to accommodate alum and lime tanks. Chain pully block etc. (min. 5 m height) |
| 134 | Solution tanks-Minimum 3 tanks (one for preparation, second for dosing and third as stand by), each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30M, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device (constant head device, strength of solution upto 10% only) conforming to I.S. 9222 Part-I 1979. |
| 135 | Pure Water Sump and Pump House. |
| 136 | Capacity of sump – One hour of designed flow. |
| 137 | Pump House- Pump house of required size over the sump or by the side. |
| 138 | Store House-Suitable for alum storage of three months and 7 days temporary storage, 7 days TCL requirement in mansoon with 20% extra capacity for other sundry articles. |
| 139 | Vacuum feed type Chlorinators- Make tobe approved by MJP. |
| 140 | Conforming to I.S. 10533 - A Part-II 1983 |
| 141 | Rate for withdrawal |
| 142 | Temperature Degree 'C' |
| 143 | Degree \\"C\\" Cylinders |
| 144 | 45 67 Tonnes |
| 145 | 10 6.35 9.50 110 |
| 146 | 15 10.75 16.10 130 |
| 147 | 20 14.50 21.24 254 |
| 148 | 27&Above 18.70 28.12 315 |
| 149 | Chlorinator equipment and container room to conform to I.S. 10553 Part-I 1983. |
| 150 | 100% standby shall be provided. |
| 151 | By pass arrangements - C.I. or M.S. pipes. |
| 152 | Disposal of waste from WTP : Safe disposal arrangement to nearby nalla including cost of pipe. |
| 153 | For WTP of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided , including sump, pumping machinary, rising main etc. complete. |
| 154 | Drainage arrangements To decant all units of WTP with CI pipes upto boundary of each unit and further extension with RCC pipes to nearby nalla. |
| 155 | Electrical installation – Both internal and external including entire plant area. |
| 156 | Laboratory equipment –As per requirement (to be specified during tendering). |
| 157 | Sanitary blocks – Carpet area -15 square metre minimum upto 25 Mld and 25 square metre above 25 Mld. |
| 158 | Administrative block and internal road-To accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and WBM road to connect all units from main gate of plot. |
| 159 | Rates given below are inclusive of up lift pressure if any and dewatering during entire work. |
| 160 | All pipes conduits channel with 20% overloading. |
| 161 | These rates are applicable for seismic zones 2, 3 and 4. |
| 162 | All RCC structures shall be constructed in M-300 |
| 163 | Note: Conditions from Sr. No. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants (proposed). |
| 164 | Cost of 10 MLD Conventional Water Treatment Plant |
| 165 | Electrical Works for Intake and WTP |
| 166 | 11/.433 KV DSS with 315 KVA Distribution Transformer |
| 167 | Providing and erecting Vaccum circuit breaker (VCB) panel indoor type including CT ofrequired ratio for metering and protection including 3 O/C and E/F relay and high speed trip relay. 11 kV system 1250 Amp 25 kA |
| 168 | Providing and Fixing of MCCB and Accessories in Existing Cubicle Panel Board'The work includes supplying, providing, and fixing molded case circuit breakers (MCCB) of different ratings with thermomagnetic release and terminal spreaders in the existing cubicle panel board. The scope covers drilling holes in the cubicle panel, making proper connections, and ensuring safe installation as required. The MCCBs to be installed comprise: 1 No. of 400 Amps, 35 KA, adjustable thermal setting; 2 Nos. of 250 Amps, 35 KA, fixed thermal setting; 3 Nos. of 100 Amps, 16 KA, fixed thermal setting; and 1 No. of 500 Amps, 415 V heavy-duty three-phase with neutral busbar. Additionally, 4 Nos. of 32 Amps TPN, 10 KA, “C” curve miniature circuit breakers (MCB) are to be provided and fixed. The panel shall also be equipped with 3 Nos. LED indicator lamps in R/Y/B, 1 No. digital voltmeter (0–500 V, class 0.5), 1 No. digital ammeter (0–500 Amp), and 3 Nos. current transformer (CT) coils with CT ratio 300/5 Amp. The complete panel work shall further include provision of panel enclosure (considered as 50% of the total MCCB and accessory cost) and panel wiring, casing, tagging, termination, and all associated works to deliver a fully functional and tested system. |
| 169 | APFC PanelSITC of Automatic power factor correction panel with 125 kVAR Capacitor bank comprising with APFC relay, capacitor banks,contator,indicating lamp, power factor meter, free standing made of sheet steel enclosed, aluminium bus bar, earthing pads, complete with power & control wiring and suitable to improve the power factor of the system up to 0.98 lag. |
| 170 | FCMA / HFSR Electrical Soft starterProviding erecting and giving test and trial of FCMA fully Automatic, Starter with DOL Soft Starter complete with main Contactor, VAF meter , PLC and HMI , push buttons and indications,FCMA module with bypass contactor and its control circuitry etc complete.LG 6-16 - 180 HP |
| 171 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries, FCBC ( Float cum boost charger)suitable for 415V +/-10%, 50 Hz , 1-ǿ / 3 -ǿ Input & 24/ 48 /110 V DC Output Natural Cooled, free standing in Sheet Steel enclosure,SCR controlled , regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,Built in DC Distribution Board (6 No MCB), indication , control as required. All as per pre approved by Engineer in-charge. |
| 172 | Supply , Installation, Testing and Comissioning of wall mounted remote ON/OFF Push Button station for AHU/Air washers made out from powder quoted CRCA sheet of 16 SWG , illuminated ON/OFF push button including making connections etc as required complete in all respect. All as per pre approved by Engineer in-charge. |
| 173 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 174 | 1.1 kV 3.5 C-185 sqmm XLPE Cable |
| 175 | 1.1 kV 3.5C-300 AL XLPE cable |
| 176 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 177 | 4Cx16 sqmm, AL, 415V, 1.1 kV |
| 178 | 1.1 kV 3C-6 AL XLPE cable |
| 179 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. |
| 180 | 1.1 kV 3.5C-300 AL XLPE cable |
| 181 | 1.1 kV 3.5C-50 AL XLPE cable for Motors |
| 182 | 1.1 kV 4C-16 AL XLPE cable |
| 183 | 1.1Kv 4Cx10sqmm, AL, XLPE |
| 184 | 1.1KV 3Cx25sqmm CU XLPE Cable |
| 185 | Providing and laying Stranded/ Flexible Annealede Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyster taped Al (inner sheated GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel armoured overall PVC sheathed (ST-1) overall screened Core armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009.'1.1 kV 10C-2.5 CU XLPE cable for Trf. Protection and LPBS |
| 186 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in-charge. |
| 187 | 1.1 kV 3C-50 AL XLPE cable(Indoor) |
| 188 | 11 kV 3C-185 AL XPLE cable(Indoor) |
| 189 | 11 kV 3C-185 AL XPLE cable(Outdoor) |
| 190 | S & Making Heat shrinkable type Tubular sleeve version outdoor straight through joint for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade as required. All as per pre approved by Engineer in-charge. |
| 191 | 1.1 kV 3.5C-300 AL XLPE cable |
| 192 | 1.1 kV 4Cx16sqmm, AL XLPE Cable |
| 193 | 1.1 kV 3C-2.5 CU XLPE cable |
| 194 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 |
| 195 | 1.1 kV 3C-2.5 CU XLPE cable |
| 196 | 1.1 kV 10C-2.5 CU XLPE cable |
| 197 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in-charge. |
| 198 | 11kV 3C-185 sqmm XLPE Cable (OUT DOOR) |
| 199 | 11kV 3C-185 sqmm XLPE Cable (INDOOR) |
| 200 | S & Making Heat shrinkable type Tubular sleeve version outdoor straight through joint for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade as required. All as per pre approved by Engineer in-charge. |
| 201 | 1.1kV 3.5C-300 sqmm AL XLPE Cable |
| 202 | 4Cx16sqmm, AL, 415V, 1.1 kV |
| 203 | 1.1 kV 3C-6 AL XLPE cable |
| 204 | 1.1 kV 3Cx2.5sqmm, CU XLPE Cable |
| 205 | Galvanized Cable trays |
| 206 | Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in-charge. 300mm x 62.5mm x 2.0mm |
| 207 | Earthing |
| 208 | Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. |
| 209 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. |
| 210 | 50mm x 6mm G.I. Strip |
| 211 | 25mm x6mm G.I. Strip |
| 212 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. |
| 213 | 10 SWG G.I. Wire |
| 214 | Lightning Protection |
| 215 | Lightening Conductor of G.I. bar of 25mm dia& 2m long |
| 216 | Providing & Fixing of G.I. tape (Hot Dipped galvanized ) 20mm x 3 mm on parapet or surface of wall fixed with porcelain or bakelite insulator (SP-35) in vertical/horizontal run as required. All as per pre approved by Engineer in charge. 20mm x 3mm G.I. ( Hot Dipped ) Strip |
| 217 | Supply and fixing of 1.6 mm thick MS 11 kV Danger plates as per IS :2551-1982 & specification of Discom on the existing poles complete in all respectas as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 218 | Indoor and Outdoor Illumination System |
| 219 | 7 Mtr. height Octagonal Hot - Dip galvanized pole (BOP - 7030) with top dia 70 mm, bottom dia 130 mm & made of 3 mm thick sheet, base plate dimensions 200 X 200 X 12 mm ( L x B x T) including suitable sizes of foundation bolt all complete as reqd. |
| 220 | 1 meter Single Arm suitable for 70mm Top |
| 221 | Installation, Testing & Commissioning of the 7 Mtr. Octagonal Pole & light fitting with the help of suitable tools and plants, wiring of luminaires with all materials and construction of shallow foundation with M25 grade concrete considering safe soil bearing capacity of 10T/mtrs sq. |
| 222 | S/F 6 amps to 32 amps rating 240 volts, ‘C’ series miniature circuit breaker suritable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as reqd.6/32 amps,Single pole |
| 223 | SITC of following rating LED street lighting luminari with pressure die cast housing and toughtend glass cover ,IP 66 protection,lumonous EFFICARY>=110 LM/W with lens in existing pole/pipe for supply voltage 100-270 V AC,50 Hz.Luminarie shall be confirm to IS:10322 part 5/section 3 and shall be complete with all necessery accessories as reqquired.120W LED street light |
| 224 | Supplying and drawing following size of FR PVC insulated copper conductor single core cable in existing surface/recessed steel/PVC conduit including dismantling as required 3x1.5 sqmm |
| 225 | Supply of XLPE insulated sheathed (heavy duty) armoured electric cables with Aluminium conductor for working voltage 1100 volts conforming to IS:7098 (part-1)/IS:1554; 4 core x16 sq mm |
| 226 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required; 4 X 16 sq. mm (28mm) |
| 227 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation, cushioning, protective coveringand and refilling the trench etc. as required |
| 228 | Supplying and laying of 40mm dia medium class GI pipes for road crossing |
| 229 | Earthing with GI earth pipe 4.5 mtr long,40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. |
| 230 | Supplying and laying 6 SWG GI wire at 0.50 meter below ground level for conductor earth electrode, including soldering etc as reqd. |
| 231 | S.I.T.C of Outdoor stand mounted feeder peelar with 63 amps TP&N,MCB incomer ,65 amps TP contractor automatic switch of luminaries,power tool control incommer outgoing terminal etc as required |
| 232 | Miscellaneous Items |
| 233 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in-charge. |
| 234 | 33 KV, class C 3 mm thick with proof voltage 36 KV AC (rms) for 3 min. and Break Down Voltage 65 KV AC (rms) |
| 235 | 3.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms) |
| 236 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in-charge. 1400 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) |
| 237 | Machnical Works at Intake and WTP |
| 238 | RATES FOR HORIZONTAL SPLIT CASTING CENTRIFUGAL PUMP (1500 RPM) confirming to IS 1520Supply and delivery of Horizontal split casing centrifugal pump conforming to IS 1520 and as amended thereafter with CI casing and split glands, stainless steel shaft, hydraulically and dynamically balanced bronze impellers capable of discharging required quantity of water against a total head noted below due to all causes and with the accessories such as G.M air release cock, Grease cup, G.I priming funnel, M.S lifting hook, drip water G.I pipe connections, leading to the outside of pump house rubber water deflector, double flap foot valve, G.M strainer including unique tyre type coupling, common M.S fabricated base to mount pump and motor and other standard fittings etc complete. Pump shall be capable of discharging the specified quantity at the head noted at the minimum NPSH at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase, 415 V, 50 Hz, 1500 RPM. |
| 239 | 7947.917 LPM and 40 m Head |
| 240 | 7947.917 LPM and head 51 |
| 241 | Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking etc. complete. as per I.S.5312 Part I (1984)Without bypass arrangement -PN - 1.6(7.) 200 mm dia |
| 242 | Providing and fixing M.S. chequerred plate flooring of following thickness supported on M.S. angles (25 x 25 x 5 mm size) including welding, cutting and fabricating the plates to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge.6 mm thick |
| 243 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)(vii) 200 mm dia |
| 244 | Supplying labours, tools, tackles, lubricant etc. for laying and jointing DI/C.I.S/S Tyton pipes (class LA) trenches supplying rubber gasket (Rubber gaskets confirming to I.S.S.-5382-1969) and taking gasket joints including providing night guard, barrier and red light to safe guard against accident, all complete (Pipe to be supplied departmentally free of cost and laying of pipes is to be done as per (I.S.S. 3114 -1985) as per design, specification and direction of E/I.250 mm dia |
| 245 | Labour charge for one cutting of cast iron/DI pipe & specials including supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I.250 mm dia |
| 246 | Air Release Valve: Lowering, laying and fixing in proper alignment and position all types of CI air valves as directed by engineer in charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing etc complete. (Rate for all class of valves.) PN-1.680 mm Dia |
| 247 | EOT Crane : - Providing, Erecting and Commissioning Single Girder electrically Operated Circular/Rectangular over head travelling crane with 6 m Lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54 control panel and down pendant control block. |
| 248 | 5 T Capacity - Above 6 m upto 8 m span. |
| 249 | Square Bar / Rail :- Providing, erecting and fixing square bar of EN 8 asrail for over head crane on provided track, girder / continuous corbel beam, including supporting plate and \\"J\\" bolts..40x40 mm |
| 250 | Providing and supplying ISI mark centrifugally cast (spun) ductile iron pipes of 100 mm and above all diameter for water works with socket and spigot ends confirming to IS.8329/2000 in standard working lengths of 4.5, 5.5 & 6.0 m for classification K-9 suitable for push on joint (Rubber gasket D jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating (including cost of one no. gasket for each pipe). Rate are exfactory excluding transportation, taxes & duties contractor profit and over head charges etc. |
| 251 | Providing and supplying ISI standard D.I specials & fitting with sealing rubber gasket of S.B.R., complete with cast iron follower gland and M.S nut & bolts coated or otherwise protected from rusting and suitable for D.I pipes including cost of all labours and materials and transportation to stores / site, loading, unloading including all taxes, etc. complete as per I.S-9523, @10% (Including 10% C.P.)Socketed (200-300 mm dia) |
| 252 | Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in-charge. |
| 253 | Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC type Fire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in-charge. 4 kg |
| 254 | ESR ( Elevated Service Resevoir) |
| 255 | Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for ESR having capacity upto 500 cum and not more than 6 m c/c for ESRs having capacity above 500 Cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing off the surplus stuff within a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout,overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, C.I. manhole frame and covers, water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case from ground level to roof level, M.S. grill gate of 2 M height with locking arrangement of approved design, B.B.masonry chambers for all valves, ventilating shafts, providing and applying three coats of cement paint tothe structure including roof slab, epoxy painting to internal surface and antitermite treatment for underground parts of the structure and giving satisfactory water tightness test as per I.S. code. The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-Charge. |
| 256 | The design of the structure be in accordance with relevant I.S.specification (I.S. 3370 - 1965 or revised.) |
| 257 | The design shall satisfy the stipulations as per I.S. 1893 - 1984 and I.S. 13920 /1993 for seismic force and I.S. - 11682 / 1985 for R.C.C. staging of overhead tanks. |
| 258 | For design having more than 6 columns, provision of internal bracing is obligatory. External bracings is also obligatory. |
| 259 | Plain round mild steel bars grade-I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used, grade-II mild steel bars will not be allowed. |
| 260 | These rates include providing M.S. ladder for E.S.R.s upto 2 lakh litres capacity and providing spiral staircase for E.S.R. above 2 lakh litres capacity |
| 261 | Staging shall have to be designed with stresses of M-200 concrete for ESR. However all RCC construction should be done in M-300 |
| 262 | These rates are including the cost of uplift pressure if any and entire dewatering during execution. In case of water logging area where water is stretch at shallow depth, extra provision of dewatering shall be made as per site condition. |
| 263 | All conditions given in the Member Secretary's Circular No. MJP / TS-I / 350 / 1668 dt. 2-8-97 and MJP / S-I / 350 / 2127 dt. 13-7-99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below. |
| 264 | 75% part rate shall be payable for reinforcement concrete and plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete. |
| 265 | The rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. The scope of work, however, includes cost of erecting, laying and jointing of pipes and valves including cost of jointing materials upto 5 M beyond outer face of outermost column |
| 266 | For ESR upto 500 cum capacity C.I. double flanged pipes upto 300 mm dia shall be provided and C.I. specials shall be used. For ESR above 500 cum capacity C.I./M.S. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti-corrosive epoxy treatment from inside and outside. |
| 267 | Below mentioned rates are for foundations with individual footing with bearing capacity of 20 tonnes per square metre. For raft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5% where SBC is more than 5 MT/sqm and upto 10 MT/sqm. This % of 5% or 7.5% is applicable for estimation of amount of lumpsum item of ESR. For extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant DSR item. |
| 268 | 1. ESR - 1980 KL , Staging - 25 m |
| 269 | 2. ESR - 1840 KL , Staging - 27 m |
| 270 | Distribution System |
| 271 | Providing and supplying ISI mark centrifugally cast (spun) ductile iron pipes of 100 mm and above all diameter for water works with socket and spigot ends confirming to IS.8329/2000 in standard working lengths of 4.5, 5.5 & 6.0 m for classification K-7 suitable for push on joint (Rubber gasket D jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating (including cost of one no. gasket for each pipe). Rate are exfactory including transportation, taxes & duties contractor profit and over head charges etc. |
| 272 | 100 mm dia |
| 273 | 150 mm dia |
| 274 | 200 mm dia |
| 275 | 250 mm dia |
| 276 | 300 mm dia |
| 277 | 400 mm dia |
| 278 | 450 mm dia |
| 279 | 500 mm dia |
| 280 | Supplying labours, tools, tackles, lubricant etc for laying and jointing DI/C.I. S /S tyton pipes (class LA) trenches, supplying rubber gasket (Rubber gasket confirming to I.S.S -5382 -1969) and making gasket joints including providing night guard, barrier and red light to safe guard against accident all complete ,laying of pipes is to be done as per ( I.S.S 3114-1985 ) as per design, specification and direction of E /I |
| 281 | 100 mm dia |
| 282 | 150 mm dia |
| 283 | 200 mm dia |
| 284 | 250 mm dia |
| 285 | 300 mm dia |
| 286 | 400 mm dia |
| 287 | 450 mm dia |
| 288 | 500 mm dia |
| 289 | Supplying labours, tool and tackles for testing of laid CI or UPVC or HDPE or AC pressure pipe upto 60 m head of water all complete as per specification and direction E/I. |
| 290 | 100 mm dia |
| 291 | 150 mm dia |
| 292 | 200 mm dia |
| 293 | 250 mm dia |
| 294 | 300 mm dia |
| 295 | 400 mm dia |
| 296 | 450 mm dia |
| 297 | 500 mm dia |
| 298 | Providing and supplying ISI standard D.I specials & fitting with sealing rubber gasket of S.B.R., complete with cast iron follower gland and M.S nut & bolts coated or otherwise protected from rusting and suitable for D.I pipes including cost of all labours and materials and transportation to stores / site, loading, unloading including all taxes, etc. complete as per I.S-9523 |
| 299 | 100-150mm |
| 300 | 200-300mm |
| 301 | 350-450 mm |
| 302 | 500-600mm |
| 303 | Labour charge for one cutting of cast iron/DI pipe & specials including supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I. |
| 304 | 100 mm dia |
| 305 | 150 mm dia |
| 306 | 200 mm dia |
| 307 | 250 mm dia |
| 308 | 300 mm dia |
| 309 | 400 mm dia |
| 310 | 450 mm dia |
| 311 | 500 mm dia |
| 312 | Providing double flange sluice valve (50 mm to 1200 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete.Without bypass arrangement PN-1.6 |
| 313 | Sluice Valve |
| 314 | 100 mm dia |
| 315 | 150 mm dia |
| 316 | 200 mm dia |
| 317 | 250 mm dia |
| 318 | 300 mm dia |
| 319 | 450 mm dia |
| 320 | 500 mm dia |
| 321 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. Sluice Valve |
| 322 | 100 mm dia |
| 323 | 150 mm dia |
| 324 | 200 mm dia |
| 325 | 250 mm dia |
| 326 | 300 mm dia |
| 327 | 450 mm dia |
| 328 | 500 mm dia |
| 329 | Providing double flange sluice valve (50 mm to 1200 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete.Without bypass arrangement - PN - 1Scour Valve |
| 330 | 80 mm Dia |
| 331 | 100 mm dia |
| 332 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. Scour Valve |
| 333 | 80 mm Dia |
| 334 | 100 mm Dia |
| 335 | Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications having small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring,with built-in Kinetic features, isolating sluice valve mounted in horizontal position and operated by wheel gearing, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, in all respect etc. complete.b) Kinetic Air Valve Flanged Type - PN -1.6 |
| 336 | 80 mm Dia |
| 337 | 100 mm Dia |
| 338 | Lowering, laying and fixing in properalignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves)c) Kinetic Air Valve (PN-1 and PN - 1.6) |
| 339 | 80 mm Dia |
| 340 | 100 mm Dia |
| 341 | Full-Bore Electromagnetic Flow Meter:Supply, install and commission Electromagnetic Flow Meter (EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/-0.5% of measured value & protection as per given specifications for size 100 mm-1000mm including sensor, transmitter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications. |
| 342 | 150 Nominal Dia Flowmeter |
| 343 | 200 Nominal Dia Flowmeter |
| 344 | 250 Nominal Dia Flowmeter |
| 345 | 300 Nominal Dia Flowmeter |
| 346 | 500 Nominal Dia Flowmeter |
| 347 | House Service Connection |
| 348 | Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends, couplers,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer in charge. |
| 349 | A) Household Connection without water meter (Compression Saddle+ISI Mark Ferrul) for HDPE & PVC pipe |
| 350 | For MDPE/UPVC Pipe Service Connection on Disribution main |
| 351 | (With Road Crossing)For 15 mm Service connection |
| 352 | I S I mark as per IS 779/1994Providing, installing and giving satisfactorily field testing of domestic water meter, horizontal inferential type multijet type with magnetic drive and dry dial suitable for 50 degree temperature duly sealed against tampering complete with couplings at both ends and conforming to class B as per IS 779/1994 (VI revision) with ISI mark along with manufacturer's test certificates and guarantee certificates including cost of all labour and materials.15 mm dia |
| 353 | Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1\\" .Base of the box should be designed in such a way That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box. Provision for fixing Name plate showing the name of the Department etc., complete and as directed by E/I. |
| 354 | N.H. CROSSING |
| 355 | Manufacturing providing and supplying spirally welded / ERW / SAW / Fabricated M.S. Pipes (Commercial Quality) including procurement of plates. Gas cutting to required size rolling, tack welding, assembling in suitable lengths to form pipes, welding on automatic welding machine and forming 'v' edge on both ends of pipe including all taxes, railway freight, insurance, unloading from railway wagon, loading into truck transport to stores / site, unloading, stacking etc. complete as per IS - 3589 and IS - 5504 as applicable as per specifications (No negative tolerance in thickness is permissible). |
| 356 | c) For 100 mm dia DI pipe - Dia of Pipe : 323.90 mm (O. D.) 9.5 mm thick MS pipe for Casing |
| 357 | e) For 200 mm dia DI pipe - Dia of Pipe : 406.00 mm (O. D.) 9.5 mm thick MS pipe for Casing |
| 358 | m) For 400 mm dia DI pipe -Dia of Pipe : 813.00 mm (O. D.) 10.0 mm thick MS pipe for Casing |
| 359 | Pushing of M.S. pipes of following dia for road crossing and railway crossing by push through method in all types of strata by using hydraulic jack and drilling machine of required diameter of below M.S. casing pipes, lowering, laying , jointing of material, required welding machinery, tripod, shain -pulley block crain, blower, compressor, loading and unloading of machinery into the trench, etc. transportation and dewatering, etc complete, as directed by engineer-in-charge butincluding the cost of M.S. pipes.. |
| 360 | a) 200 mm to 499 mm dia MS pipe |
| 361 | b) 500 mm to 1000 mm dia MS pipe |
| 362 | Providing and applying primer first coat of intertol 49 W emaline 05/58 pipe coat or any other equivalent approved paint to the internal surface of pipe line at site. |
| 363 | a) Dia of Pipe : 323.90 mm (O. D.) |
| 364 | 45 m X 3.142 X 323.90 (two surface) |
| 365 | b) Dia of Pipe : 406.00 mm (O. D.) |
| 366 | 45 + 45 m X 3.142 X 406.00 (two surface) |
| 367 | c) Dia of Pipe : 813.00 mm (O. D.) |
| 368 | 45 m X 3.142 X 813.00 (two surface) |
| 369 | First Coat |
| 370 | Second Coat |
| 371 | TRENCHLESS RAILWAY CROSSING |
| 372 | Supply and Pushing of MS casing pipe of specified thickness by trenchless method adopting micro-tunnelling or any suitable mechanical technology or technology approved by Railway below ground at all depth under running traffic condition as per railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipment’s for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (upto 3 metre depth) with proper protection at three sites with shoring sheets and ISMB's.Providing MS cutting edges for front shield and Constructing thrust bed at designated level. Necessary de-watering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Railway Authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per requirement and as per approved by railway authorities, specification and the direction of the Engineer. (Protective coating/ lining if done that will be paid extra) Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.In Rock |
| 373 | 600 mm dia 12 mm thick casing pipe |
| 374 | Providing and applying primer first coat of intertol 49 W emaline 05/ 58 pipe coat or any other equivalent approved paint to the internal surface of pipeline at site, etc. complete. |
| 375 | a) 610 mm dia MS pipe - |
| 376 | 40 m X 3.142 X 0.610 (two surface) |
| 377 | First Coat |
| 378 | Second Coat |
| 379 | Boundary Wall - For WTP + ESR1 -360m & ESR2 - 120m , |
| 380 | Removal of unserviceable soil with disposal up to 1000 m (removal of unserviceable soil including excavation, loading and disposal up to 1000 m lead but excluding replacement by suitable soil which shall be paid separately as per clause 305. |
| 381 | Plain / Renforced Cement Concrete in open foundation complete as per drawing and technical specifications.PCC Grade M20 |
| 382 | Plain / Renforced Cement Concrete in well foundation complete as per drawing and technical specifications.RCC Grade M30 |
| 383 | Providing 2 coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing, and taxes all complete as per building specification and direction of E/I. |
| 384 | Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre |
| 385 | Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete |
| 386 | Supplying, fitting and fixing M. S. grill gate with M. S. grills made of 20 x 6 mm M. S. flats or 16 mm M. S. square bars fitted on 25 x 25 x6 mm M.S. angle frame.2 Nos MS GATE |
| 387 | Estimate Of Approach Road |
| 388 | E/W in Soil by manual means, (Excavation for roadway in soil using manualmeans including loading in truck for carrying of cut earth to embankment site with all lift and lead upto 1000 meters) (ii) including Royality @ Rs. 30.0 Per cum, cost of watering, rolling & compaction |
| 389 | Granular sub-base with close graded material, plant mix method (construction of granular sub-base by providing close graded material, mixing in mechanical mix plant at OMC, carriage of mixed material to work site, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401) (i) for grading-I material |
| 390 | Water bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes/smooth 3 wheeled steelroller in stages to proper grade and camber, applying and brooming requisite type of screening /binding materials to fill up the interstics of coarse aggregate, watering and compacting to the required density) (A) By manual means(i) Grading-I (a) Using Screening crushable type such as moorum or gravels(with vibratory roller) |
| 391 | Providing and laying in situ Plain Cement Concrete M-15 of in open foundation complete as per drawing and technical specifications.PCC Grade M15 using batching plant & Concrete pump |
| 392 | Carriage of material from divisional store kiln site or quality site to work site including loading, unloading, transportation are complete. Including contractors profit. |
| 393 | Cement-Loading & Unloading (Truck 10 Tonne Capacity) |
| 394 | Loading &Unloading stone aggregates/sand/moorum |
| 395 | VALVE CHAMBER |
| 396 | Construction of B.W. masonry valve chamber of size 1.50x1.20x1.80Above 300 mm dia |
| 397 | Construction of B.W.masonry valve chamber of size 1.20M X 0.90M X 1.50M mt.Upto 300 mm dia |
| 398 | Thrust Block |
| 399 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. |
| 400 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming & watering in layers not exceeding 150 mm thick with all leads and lifts including cost of all materials, labour, royalty & taxes all complete as per building specification & direction of E/I. (mode of measurement compacted volume) |
| 401 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I. |
| 402 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level. 1:2:4( 1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size) |
| 403 | Providing Tor steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carrriage of MS bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 12 mm (TMTcoil Fe 500) (only valid for Sail & Tata Steel) |
| 404 | Sludge Settling Tank |
| 405 | Providing P.C.C M-10 with nominal mix of (1:4:8) in foundation with approved quality of stone metal grade-III (50mm to 25mm), size clean coarse sand of F.M 2.5 to 3 including screening, shuttering mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 406 | Providing Tor steel reinforcement of 8mm - 12 mm dia rods as per approved design and drawing excluding carriage of M.S. Rods to work site, cutting, bending, and binding with annealed wire with cost of wire removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 407 | Providing M.S. foot rests inclding fixing in manholes with 20x20x10cm cement concrete blocks 1:3:6 (1cement: 3coarse sand: 6 graded stone aggregate 20mm nominal size) as per standard design:With 20x20 mm square bar |
| 408 | Providing and fixing in position pre-cast RCC manhole cover and frame of required shape and approved qrality . Circular shape 560mm internal dia. |
| 409 | Providing and fixing soil, waste and vent pipes : 75 mm diameter : Sand cast iron S&S pipe as per IS: 1729 |
| 410 | STAFF QUARTER |
| 411 | Providing P.C.C. M -100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade- III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer & placing in position, vibrating, striking, curing, taxes & royalty all complete as per building specification & direction of Engineer-in-charge. |
| 412 | Providing and laying Damp Proof Course 50 mm thik with cement concrete 1:2:4 ( 1 cement : 2 coarse sand ( zone III ) : 4 graded stone aggregate 20 mm nominal size ). |
| 413 | Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) :3 graded stone aggregate 20 mm nominal size). |
| 414 | Supplying, fitting & fixing good quality, well dressed & well seasoned sal wood work in chaukhat in doors, windows, skylights, fanlights and C/W celestial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls & lintels all complete as per building specification & direction of the E/I. |
| 415 | Supplying fitting and fixing 250 x 20 x 6 mm L-type M.S. Clamp properly fish tailed, including making holes and setting the same in 375 x 125 x75 mm cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I |
| 416 | Supplying fitting & fixing 38 mm thick good quality well dressed and well seasoned Sal wood battened shutter ledged & braced in doors and windows with oxidized iron fitting such as hinges, sliding door bolts, tower bolts, handles or rings, hooks and eyes, cleats, sand block as per schedule, taxes & royalty all complete as per building specification & direction of Engineer–in-Charge |
| 417 | Supplying, fitting & fixing M.S. Grill made of 20 x 6 mm M.S. Flat as per approved design & drawing properly fabricated with Joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per the building specification and direction of E/I. |
| 418 | Providing 25 mm thick precast R.C.C. M-200 with nominal mix of (1:1.5:3) jali with approved quality of stone chips of 6 mm nominal size and clean coarse sand of FM 2.5 to 3 with 1.6 mm thick M.S. wire as per approved design and drawing and placing the same in position true to plumb and level and properly grouted with cement mortar (1:3) including cost of curing, scaffolding and finishing all complete as per building specification and direction of E/I. For WC (W3) |
| 419 | Providing and fixing fan hook of 16 mm dia M.S. bar 1 meter long bent to required size and shape, placed in position and fixing in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. |
| 420 | Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm. M.S. square bars fitted on 25x25x 6mm, M.S. Angle frame. |
| 421 | Providing average 115mm. thick lime terracing (24 lime :36 surkhi:100 brick khoa) well beaten and compacted including maintaining proper level & slope, making ghundi with finishing treatment, cost of carriage,curing, royalty & taxes all complete as per building specification & direction of E/I. |
| 422 | Providing average 150 mm thick dry rammed khoa beaten to 112 mm. (compacted with water) made of well burnt or jhama bricks including ramming properly till compacted thickness is achieved, curing & carriage of water with all leads, making proper slope & blending the top with cement mortar (1:10) all complete as per building specification & direction of E/I. |
| 423 | Providing 25 mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layer 19 mm thick (1:2:4) with 12 mm to 6 mm size graded stone chips and top layer 6 mm thick (1:2) with 6 mm down stone chips, in panels including cost of curing , finishing the surface smooth by rubbing with carborandum stone, taxes & royalty with all complete as per building specification & direction of E/I. |
| 424 | White washing three coats over new surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales of smoke and mosh marks with jhama rubbing, scaffolding, washing, of floors and taxes all complete as per building specification and direction of E/I. For Ceiling |
| 425 | Colour washing two coats over a coat of white wash over new surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales of smoke & mosh marks with jhama rubbing, scaffolding, washing, of floor and taxes all complete as per building specification and direction of E/I. |
| 426 | Providing two coats of painting with ready mixed paint over a coat of primer of approved shade and make over new wooden surface includ n g preparing the surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specification & direction of E/I. |
| 427 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (mode of measurement area shall be multiplied by the coefficient as indicated in building specification).For Grill Gate |
| 428 | Providing two coats of painting with ready mixed paint of approved shade & make over steel surface including cleaning the surface thoroughly, scaffolding & taxes all complete as per building specification & direction of E/I.For Outside |
| 429 | Providing P.C.C. M -100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade- III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer & placing in position, vibrating, striking, curing, taxes & royalty all complete as per building specification & direction of Engineer-in-charge. |
| 430 | Providing 12 mm thick water proof cement plaster (1:3) in CM 1:3 with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound all complete as per building specification & direction of EЛ. |
| 431 | Providing, hoisting and fixing in position C.I. manhole, frame and cover of best quality and of required size and shape with locking arrangements including applying 2 coats of anti-corrosive paint, etc. complete. |
| 432 | Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 433 | Supplying materials and labours for constructing inspection chamber of designation class 75-8 bricks size 750 mm deep, 600 mm x 450 mm internal dimension having 250 mm wall thickness in cement mortar (1.6) including 12 mm cement plaster (1:4) with punning on side and cement plaster (16) with 600 mm x 475 mm G.I. cover with frame (weight not less than 36Kg) along with earth work in excavation and 80mm thick PCC-(1:3:6) in foundation and refilling all complete as per specification and direction of E/I |
| 434 | Supplying, fitting and fixing vitreous white glazed earthen ware I WC of Perry Hindustan or any other ISS approved make with 100mm HC.I. 'P' TRAP (15) Liters C.I. pull and let go flushing C.I.stern of names or other ISS equivalent make, complete with all fittings, C.. or C.C. brackets 32 MM alkathenae PVC telescopic flush, pipe about 2m long with one brass coupling and clamps G.I. Chain and pull including supplying and fixing a pair or vitreous white glazed earth ware footrest to be fixed in floor 50Gms., 15mm PVC Connection pipe 450 mm Long and the exposed pipe and C.I.stem with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of EA. 580 mm long with 12.5 lit low level PVC cistern |
| 435 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of Perry of Hindustan or any other iSS approved make supported on painted C.I. or RS Brackets 32mm CI brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc all complete as per specification and direction of EЛ. |
| 436 | Providing and supplying in standard lengths High Density Polyethylene Pipe (HDPE Pipe) confirming to IS 4984/ 14151/ 12786/ 13488 (Latest Revision with necessary jointing materials like mechanical connector i.e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joints excluding coupler / specials and taxes)HDPE pipe of materials grade PE80-PN10 (dia in mm) |
| 437 | 1) 110 mm dia |
| 438 | 2) 75 mm dia |
| 439 | Supplying HDPE/uPVC pipe fitting and labour tools and equipments for laying of all size HDPE/uPVC fitting and fixing in trainches / on wall etc all complete as per direction of E/I |
| 440 | 110 mm dia |
| 441 | Coupler |
| 442 | Door Tee |
| 443 | Plain Bend |
| 444 | Door Bend |
| 445 | Pipe Clip |
| 446 | Slotted cowl |
| 447 | 75 mm dia |
| 448 | Coupler |
| 449 | Door Tee |
| 450 | Plain Bend |
| 451 | Door Bend |
| 452 | Pipe Clip |
| 453 | 110 mm x 75 mm dia |
| 454 | P. trap ( 110 x 110 mm ) |
| 455 | Adhesive solvent cement |
| 456 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 457 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 458 | a) 2x2.5 sq mm + l x 2.5 sq mm earth wire (M.C.B. to board) |
| 459 | b) 2x4.0 sq mm + l x 4 sq mm earth wire ( main to M.C.B. to light) |
| 460 | c) 2x6.0 sq mm + l x 6 sq mm earth wire (main to M.C.B. to power) |
| 461 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 462 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections. painting etc. as required. |
| 463 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 464 | Supplying and fixing brass batten/ angle holder including connection etc.asreqd. |
| 465 | S/F 3 pin 5 Amp. Ceiling rose on the existing junction box /wooden block including connection as per reqd. |
| 466 | S/F following piano type switch/socket on the existing switch box cover including connection etc as per reqd. |
| 467 | 5/6 amps switch |
| 468 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 469 | 75 mm X 75 mm X 60 mm deep |
| 470 | 100 mm X 100 mm X 60 mm deep |
| 471 | 150 mm X 75 mm X 60 mm deep |
| 472 | 150 mm X 150 mm X 60 mm deep |
| 473 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 474 | a) 40 Amps |
| 475 | b) 63 Amps |
| 476 | SCADA |
| 477 | Supply,Installation,Testing & Commissioning (SITC) of centralized SCADA Monitoring center equipment |
| 478 | Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 1200 mm X 800 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following:- Programmable Logic Controller (PLC) with Dual Hot Redundant CPU, Power supply, Communication Module, IO & Processor rack (Standard DC), Back up Interface/Expansion Module, Rack (Backplane) 10 slots for IO and Processor. SCADA software shall have facility VPN, OPC, Smart Client, Web Enabled, Automation Report Generation, Archiving, Treands, Data Logging, etc. |
| 479 | MCB 16A DP |
| 480 | MCB 6A DP |
| 481 | SMPS 100-240VAC/ 4.5A / 24 VDC |
| 482 | Selector Switch (Auto/Manual) & Local / Remote |
| 483 | Control Relays |
| 484 | Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with |
| 485 | Electronic Hooter |
| 486 | Control Transformer 200VA |
| 487 | Emergency STOP Push Button |
| 488 | Panel Cooling Fan & Filter |
| 489 | Panel Light with Door Switch, 7W |
| 490 | Control Indication Lamp for 24VDC, 220VAC |
| 491 | Push Button |
| 492 | Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc |
| 493 | Panel Hardware, lugs, terminations, ferrules, name plate Etc. |
| 494 | UTILITY SOCKET 16A, 3 PIN |
| 495 | HMI Display 15 Inch, Colour |
| 496 | Isolators Dual Output, 24VDC |
| 497 | Ethernet Switch ( Managed) |
| 498 | Operator Station including, Core i7 processor, 8 GB RAM, 1TB SSD, DVD RW Drive, RS-232/485/RJ45 Port, 1 Parallel Port, 4 nos. USB Port, 2x Ethernet Cards, Keyboard, Optical mouse, 32'' LED monitor, Latest windows professional, Anti Virous, etc. |
| 499 | Engineering Station including, Core i7 processor, 8 GB RAM, 1TB SSD, DVD RW Drive, RS-232/485/RJ45 Port, 1 Parallel Port, 4 nos. USB Port, 2x Ethernet Cards, Keyboard, Optical mouse, 32'' LED monitor, Latest windows professional, Anti Virous, etc. |
| 500 | Run Time & Development Programming and Troubleshooting software for PLC, HMI, SCADA, VPN, Web Client - OWS |
| 501 | Black and white, A4 Size Laser Printer, copier Scan.Hi-Speed USB 2.0 port; built-in Fast Ethernet 10/100Base-TX network port; built-in WIFI 802.11b/g/n |
| 502 | Online UPS 5 KVA with 60 min Backup time. |
| 503 | SITC of Intelligent Manageable Ethernet Switches providing 24 x 10/100/1000 Fast Ethernet ports- and 2 dual purpose uplink (provision for Copper / Fibre Giga connectivity) with LAN based Software. The LAN based S/W supports enhanced integrated security, including Network Admission Control (NAC), advanced quality of service (QoS), availability and scalable management to enable new converged applications |
| 504 | Supply, Installation, Testing, Intgeration & Commissioning of 49\\" LCD monitor at Conf. Room for display of total water system (Online) |
| 505 | Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, 3 Phase 415 V, 50 Hz with 2 hour backup SMF battery bank as per specification7.5 KVA |
| 506 | Surveillance System |
| 507 | Desiging, supplying, installing, commissioning & testing of CCTV IR water proof camera suitable for upto 100ft. with control key board, DVR, Hard Disk,cables, UPT transreceivers etc. complete with not less than following specifications.1. Four numbers of IP Camera with night vision functionality with range up to 30 meters. Camera construction shall be suitable for weather proof outdoor installation.2. Eight Channel DVR with metal body construction, having software features of motion detect recording.3. 3.5 inch 2 GB HDD4. 8 port POE Switch5. 32 inch LED Screen, Keyboard & mouse. |
| 508 | SITC of GPRS gateway PLC based along with necessary software and hardware, Controls 50 nos. SLC, 140-270Vac, CE/FCC certified communication module, Battery backup up to 24 hours, On-board 2 nos. current (4-20mA), and 2 nos. antilog voltage channel(1-10V), On-board RS485 Modbus interfaceThree Phase |
| 509 | Telephone Accessories (WG-TW/TA) Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 24 extensions suitable upto 96 extensions complete. |
| 510 | Compact RTU complete with DI, DO, AI and modbus communication ports and power supply. // Compact RTU for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated modem; connection to control center via Tele Control Basic, DNP3, IEC60870-5-104 and Communication protocols, on-board I/O (8 DI, 4 DQ, 4 AI), configuration and diagnostics per web interface, RJ45 port, mobile communications antenna (GSM/UMTS), Mini SIM card, with adapter Micro SIM card also, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client. Panel Enclosure for Compact RTU Location, wall/floor mounted along with wiring and related accessories and arrangement of mounting of RTU, Modem and having IP-5X Protection. Panels shall be self-fabricate type only with Canopy. |
| 511 | Supply, Installation, Testing and Comissioning of Window type Air conditioners as per BEE star rating complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 230 V +/- 10% with low & high voltage cutoff and 50 Hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation R-32/R-410 Green Refrigerant with Scroll / rotary compressor complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. All as per pre approved by Engineer in-charge. 1.5 TR ISEER not less then 3.0 |
| 512 | SITC of UL 10th edition / EN54 / VDS certified Microprocessor based inteligent, Analogue addressable,modular, expandable networkable loop Fire Alarm Control Panel with each loop capacity of min 125 detectors per loop with total of 125 detectors & devices with Loop length up to 1 KM as per NFPA 72 approval. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. . The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, LCD/LED unit to indicate Fire / Fault Signal of individual unit, inbuilt networking port(both RS485&Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in-charge. 2 Loop Pannel |
| 513 | Ultrasonic level transmitter raddar type level transmeter for raw water pumping station |
| 514 | Designing, Supplying, Installing, commissioning & testing of Ultrasonic Raddar type Ultrasonic level transmitter CE marked with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement. |
| 515 | Output-4-20 mA / HART |
| 516 | Power supply - 24V DC ext. |
| 517 | Display - 4\\" LED |
| 518 | Range- 0 to …30... mtrs |
| 519 | Accuracy - +/- 0.25% of Full Scale or better |
| 520 | Enclosure- IP 68 |
| 521 | Mounting - On PLC panel |
| 522 | Full-Bore Electromagnetic Flow Meter: |
| 523 | Supply, install and commission Electromagnetic Flow Meter (EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/- 0.5% of measured value & protection as per given specifications for size 100 mm- 1000mm including sensor, transmitter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM/GPRS ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications. |
| 524 | 100 mm Nominal Diameter Flowmeter |
| 525 | 200 mm Nominal Diameter Flowmeter |
| 526 | Pressure Transmitter for raw & pure water pumping station |
| 527 | Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement. |
| 528 | Output 4-20 mA / HART |
| 529 | Power supply - 24V DC ext. |
| 530 | Display - 4\\" LED |
| 531 | Accuracy - +/- 0.1 % of full scale or better |
| 532 | Enclosure- IP 68 |
| 533 | Pressure Guages at outlet line:- Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main.Pressure gauge (150 mm dia) |
| 534 | Instrumentation cable (2 pair x 1sq.mm):- Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 2 Pair x 1 sq.mm as per IS 694 copper Shielded twisted, multistranded armoured cable on wall in GI tray or on ground. |
| 535 | Cable Trays:-Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. All as per pre approved by Engineer in charge. 100mm x 50mm x 1.6mm |
| 536 | PLC panel for Raw water pump House with two Pumps |
| 537 | Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel of size approx. 1000 mm X 700 mm X 1500mm (LBH), fabricated out of min. 2 mm thick CRCA sheet powder coated to Siemens gray color. The Panel shall be provided with reputed make PLC with following accessories as well as input output configuration. The PLC shall be programmed with IEC 61131 standards for control, monitoring and communication of equipments & instruments at Raw water Pumphouse. PLC shall have Ethernet port & protocal for Modbus TCP communication with following IO. |
| 538 | 7 inch color TFT HMI complete with programming shall be provided to interact with PLC. The panel shall include all the accessories (not limited to following) to achieve purpose of smooth & trouble free operation of pump house. |
| 539 | MCB 10A DP |
| 540 | MCB 4A DP |
| 541 | 24 VDC Power Supply 10A |
| 542 | Push Buttons |
| 543 | Selector Switch |
| 544 | Control Contactor |
| 545 | Annunciator with 6 Windows |
| 546 | NO to NC Type |
| 547 | Electronic Hooter |
| 548 | Control Transformer |
| 549 | Emergency PB |
| 550 | Panel Cooling Fan |
| 551 | Panel Light with Door Switch |
| 552 | Control Indication Lamp |
| 553 | Wiring + TB etc |
| 554 | Hardware |
| 555 | Scada system for Raw water pump House |
| 556 | Design, manufacture, supply, installation, testing and commissioning of SCADA System for pump house. Windows based PC with latest configuration & OS complete with necessory office & antivirus softwares. PC configuration shall not be less than Intel i5 10th Gen CPU, 16 GB Ram, 128 GB SDD, 500 GB HDD, DVD RW, Rs232 & Rs485 port, 2 RJ45 ports, Keyboard, Optical Mouse, 32 inch color TFT Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Sequrity software for 3 years license. |
| 557 | SCADA Software of reputed company with developer & runtime license with minimum 256 number of Tags with following features & functions |
| 558 | 1. Supervise real-time data in the form of graphical presentation |
| 559 | 2. Control pumping processes locally or through Remote locations |
| 560 | 3. Dynamic process Graphic, It should resemble the process mimic. SCADA should have good library of symbols so that develop the mimic as per required. When operator sees the screen he should know what’s going in plant. |
| 561 | 4. Alarm summery & Alarm history, SCADA system must be able to detect, display, and log alarms and events. When there are problems the SCADA system must notify the operators to take corrective action. |
| 562 | 5. Acquire real-time data as well as logs data with Real time trend & Historical time trend. |
| 563 | 6.Web Connectivity, Real-time displays can be accessed on remotely attached PCs and notebooks using internet. |
| 564 | SCADA Programming shall be done so as operator can visualize and control complete pump house operation from operator desk. All important alarms & events shall be logged. All the data from field instruments & equipments shall be logged. There shall be provision to take reports in required formats of real time & historical data, events & alarms. |
| 565 | There shall be provision of broadcasting messages, emails of reporting information. There shall be provision of access security. An Industrial grade Din rail mounting ethernet switch with 5 ports shall be provided. An Industrial grade modem with 4G/5G GSM connectivity shall be provided. |
| 566 | Supply, Installation, Testing, Intgeration & Commissioning of 49\\" LCD monitor at Conf. Room for display of total water system (Online) |
| 567 | Ultrasonic level transmitter for pure water pumping station |
| 568 | Designing, Supplying, Installing, commissioning & testing of Ultrasonic level transmitter CE marked with following technical parameters at pure Water Pump House and Interfacing with PLC panel including Mounting accesories. |
| 569 | Range- 0 - 5 mtrs |
| 570 | Output-4-20 mA / HART |
| 571 | Power supply - 24V DC ext. |
| 572 | Display - 4\\" LED |
| 573 | Accuracy - +/- 0.25% of Full Scale or better |
| 574 | Temp.- With Inbuilt temp compensation |
| 575 | Enclosure- IP 68 weatherproof |
| 576 | Mounting - Top/above FSL of Tank |
| 577 | Open channel type ultrasonic flowmeter with FIT |
| 578 | Design, Supply, Installation, Testing & calibration of open chanel type ultrasonic flow Transmitter CE marked with following technical parameters at Raw Water channel and Interfacing with PLC panel including mounting arrangement. |
| 579 | Range- 0 - 5 mtrs |
| 580 | Output-4-20 mA / HART |
| 581 | Power supply - 24V DC ext. |
| 582 | Display - 4\\" LED |
| 583 | Accuracy - +/- 0.25% of Full Scale or better |
| 584 | Enclosure- IP 68 |
| 585 | Providing, installation, testing and commissioning of Level Switch (Conductivity) Conductivity Probes, Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminium Rigid for lengths of up to 3 Mtr. |
| 586 | pH Analyser |
| 587 | Design, Supply, Installation, Testing of pH analyser as per IUPAC( International Union for Pure & Applied Chemistry)at A.F. and Interfacing with PLC panel including mounting arrangement. Range : 0 ‐14 , pH Accuracy : Better than 0.1% of full scale , Supply Voltage : 24V dc, Output : 4‐20 mA /HART As per IEC 61000-6-2 & IEC 61000-6-3 |
| 588 | Turbidity Analyser |
| 589 | Design, Supply, Installation, commissioning, testing of Turbidity Anayser as per ISO 7027 scattering light method at A.F. and Interfacing with PLC panel. Turbidity analyser shall comprises of 3 components i.e. sensors,signal distributor and transmitter with indicator. with 2 Outputs, 1 to PLC & anather to Local Display with mounting arrangement. |
| 590 | Overall Range : 0 ‐ 2000 NTU |
| 591 | Accuracy : +/‐ 0.02 NTU |
| 592 | Supply Voltage : 230 V ac |
| 593 | Output : 4‐20 mA /HART |
| 594 | Residual chlorine analyser |
| 595 | Design, Supply, Installation,Testing of Residual chlorine analyser / meter must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors,flow through assembly and transmitter with indicator and gives 2 outputs one to Local display & other to PLC including Mounting arrangement. Overall Range : 0 ‐ 8 mg/l (ppm) Accuracy : 2% of full scale Supply Voltage : 230 V ac Output : 4‐20 mA Membrane free sensor of 2 gold plated electrodes for long termstability and reference electrode (ag/Agcl) must be provided to avoid maintenance. IP 65 Nema 4 housing protection class required. |
| 596 | PLC Panel for WTP Automation |
| 597 | Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel of size approx. 1200 mm X 700 mm X 1500mm (LBH), fabricated out of min. 2 mm thick CRCA sheet powder coated to Siemens gray color. The Panel shall be provided with reputed make PLC with following accessories as well as input output configuration. The PLC shall be programmed with IEC 61131 standards for control, monitoring and communication of equipments & instruments at WTP Plant (raw water monitoring, alum dosing control, clariffaculator operation & control, recirculation & mud pump operation). PLC shall have Ethernet port & protocal for Modbus TCPcommunication with following IO |
| 598 | 10 inch color TFT HMI complete with programming shall be provided to interact with PLC The panel shall include all the accessories (not limited to following) to achieve purpose of smooth & trouble free operation of WTP plant. |
| 599 | MCB 16A DP |
| 600 | MCB 10A DP |
| 601 | MCB 4A DP |
| 602 | 24 VDC Power Supply 10A |
| 603 | Push Buttons |
| 604 | Selector Switch |
| 605 | Control Contactor |
| 606 | Annunciator with 12 Windows |
| 607 | NO to NC Type |
| 608 | Electronic Hooter |
| 609 | Control Transformer |
| 610 | Emergency PB |
| 611 | Panel Cooling Fan |
| 612 | Panel Light with Door Switch |
| 613 | Control Indication Lamp |
| 614 | Wiring + TB etc |
| 615 | Hardware |
| 616 | SCADA system for WTP |
| 617 | Design, manufacture, supply, installation, testing and commissioning of SCADA System for WTP Plant, Sand Filter beds & pump house. Windows based PC with latest configuration & OS complete with necessory office & antivirus softwares. PC configuration shall not be less than Intel i5 10th Gen CPU, 16 GB Ram, 128 GB SDD, 500 GB HDD, DVD RW, Rs232 & Rs485 port, 2 RJ45 ports, Keyboard, Optical Mouse, 32 inch color TFT Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Sequrity software for 3 years license. |
| 618 | SCADA Software of reputed company with developer & runtime license with minimum 512 number of Tags with following features & functions. |
| 619 | 1. Supervise real-time data in the form of graphical presentation. |
| 620 | 2. Control WTP processes locally or through Remote locations. |
| 621 | 3. Dynamic process Graphic, It should resemble the process mimic. SCADA should have good library of symbols so that develop the mimic as per required. When operator sees the screen he should know what’s going in plant. |
| 622 | 4. Alarm summery & Alarm history, SCADA system must be able to detect, display, and log alarms and events. When there are problems the SCADA system must notify the operators to take corrective action. |
| 623 | 5. Acquire real-time data as well as logs data with Real time trend & Historical time trend. |
| 624 | 6.Web Connectivity, Real-time displays can be accessed on remotely attached PCs and notebooks using internet. |
| 625 | SCADA Programming shall be done so as operator can visualize and control complete pump house operation from operator desk. All important alarms & events shall be logged. All the data from field instruments & equipments shall be logged. There shall be provision to take reports in required formats of real time & historical data, events & alarms. |
| 626 | There shall be provision of broadcasting messages, emails of reporting information. There shall be provision of access security. An Industrial grade Din rail mounting ethernet switch with 5 ports shall be provided. An Industrial grade modem with 4G/5G GSM connectivity shall be provided. |
| 627 | Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, 3 Phase 415 V, 50 Hz with 2 hour backup SMF battery bank as per specification20 KVA |
| 628 | UTILITY SHIFTING |
| 629 | Shifting of existing poles by excavation, dismantling the existing foundation, loosening of over head conductors and then erecting the same pole in newly excavated pit with PCC (500X500X1700) 1:2:4 foundation, laid over a bed of PCC(500X650X150)1:4:8 bed and coping as per actuals, assembling all the accessories from the existing dismantled poles (excluding cost of accessories) such as cross arms clamps bolts, nuts washers pin insulators etc., with all leads and lifts, labour, Including environmental and social safe guards, including all taxes, as directed by the Engineer-in-Charge etc., complete. |
| 630 | Providing and fixing new RCC poles of 9 m long 145 kg WL with PCC 1:2:4 pole concreting (500X500X1700) laid over a bed of PCC 1:4:8 (500X650X150) and coping as per actuals, assembling all the accessories from the existing dismantled poles (excluding cost of accessories) such as cross arms clamps bolts, nuts washers pin insulators etc., with all leads and lifts, labour, Including environmental and social safe guards, including all taxes, as directed by the Engineer-in-Charge etc., complete. |
| 631 | Shifting of CablesCable shifting: Excavating and stacking the excavated soil clear from edges of excavation, removing and relying the cables in identified place and refilling trenches with selected available earth including watering, consolidation in layers of 15 cms thickness including disposing off the surplus earth with all lead and lift, Including environmental and social safe guards, including all taxes, as directed by the Engineer-in-Charge etc., complete. |
| 632 | Supplying and laying cables in trench, including trench excavation, stacking the soil clear from edges of excavation, refilling the trench with available earth, including watering, consolidation in layers of 15 cms thickness including disposing off the surplus earth with all lead and lift, Including environmental and social safe guards, including all taxes, as directed by the Engineer-in-Charge etc., complete. |
| 633 | Cutting of trees along with its branches their removal away from the work site and stacking the same as per specification and direction of E/I(measurement of girth at height of one meter above the ground level) |
| 634 | Girth from 300mm to 600mm |
| 635 | Girth from 600mm to 900mm |
| 636 | Girth from 900mm to 1800mm |
| 637 | Girth above 1800mm |
| 638 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, sapling and tress girth upto 300 mm, removal of stumps of tree cut earlier and disposal of unserviceable materials and stacking of sericeable material to be used of auctioned, up to a lead of 1000 00 metres including removal and disposal of top organic soil not exceeding 150mm in thickness. |
| 639 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantling material, disposal of unserviceable material and stacking the serviceable material with all lead and lift, Including environmental and social safe guards, including all taxes, as directed by the Engineer-in-Charge etc., complete. |
| 640 | Demolishing stone rubble masonry in cement mortar manually/by mechanical means including stacking of serviceable material and disposal of unserviceable materail within 50 metres lead as per direction of Engineer - in -charge |
| 641 | Shifting of water pipe line |
| 642 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15mtr. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 643 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15mtr. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 644 | Dismantling/ removing G.I. pipes (external work) including excavation and refillingtrenches after taking out the pipes, manually/ by mechanical meansincluding stacking of pipes within 50 metres lead as per direction ofEngineer-in-charge : |
| 645 | 15 mm |
| 646 | 20 mm |
| 647 | 25 mm |
| 648 | 32 mm |
| 649 | 40 mm |
| 650 | 50 mm |
| 651 | 65 mm |
| 652 | Laying and joining of GI pipes of approved make in trenches with red lead and yarn with socket and screw joints and cutting pipes to sizes and threading ends where necessary etc. all complete as per specificationand direction or Engineer - in -charge etc., complete. & Supply labour and tools for fixing G.I pipes with red lead and yarn of following nominal bore with screwed and scoketted joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plungs cutting pipes to size and threading ends if required etc all complete as per specificationand direction of E/I. |
| 653 | 15 mm |
| 654 | 20 mm |
| 655 | 25 mm |
| 656 | 32 mm |
| 657 | 40 mm |
| 658 | 65 mm |
| 659 | Providing random rubble stone masonry in cement moratar (1:6) in foundation and plinth with hammer dressed stone of less than 0.03cum in volume and clean coarse sand of F.M. 2 to 2.5 including cost of screening, raking out joints to 20mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I |
| 660 | Ambient Air Quality Monitoring- For parameters PM-2.5 & PM-10, SO2, NO2, CO from NABL approved laboratory and submission of report complete in all respect. |
| 661 | Ambient Noise Quality Monitoring - To Identify sources of noise, Noise due to traffic/transportation of vehicles, Noise due to heavy equipment operations, Duration and variations in noise over time etc. the equivalent noise levels shall be monitored (Lday and Lnight in Leq dBA) from NABL approved laboratory and submission of report complete in all respect |
| 662 | Surface Water Monitoring– Collecting representative sample and Physical & Chemical testing of Parameter from NABL approved laboratory as per CPHEEO manual: PH, TDS, Electrical Conductivity (EC), Taste & Odour, turbidity, magnesium, Total hardness, total alkalinity, chloride, Dissolved Oxygen (DO), sulphate, nitrate, fluoride, Calcium, Iron, Pesticide, Manganese, Cooper, Aluminium, Residual Chlorine, Zinc, phenolic compound, Arsenic, Cadmium, Chromium, cyanides, lead, selenium, Mercury. |
| 663 | Surface Water Monitoring Collecting representative sample and Bacteriological Parameter testing of water from NABL approved laboratory as per CPHEEO manual: Total coliforms, faecal coliforms |
| 664 | Drinking Water Monitoring– Collecting representative sample and Physical & Chemical testing of Parameter from NABL approved laboratory as per CPHEEO manual: PH, TDS, Electrical Conductivity (EC), Taste & Odour, turbidity, magnesium, Total hardness, total alkalinity, chloride, Dissolved Oxygen (DO), sulphate, nitrate, fluoride, Calcium, Iron, Pesticide, Manganese, Cooper, Aluminium, Residual Chlorine, Zinc, phenolic compound, Arsenic, Cadmium, Chromium, cyanides, lead, selenium, Mercury. |
| 665 | Drinking Water Monitoring Collecting representative sample and Bacteriological Parameter testing of water from NABL approved laboratory as per CPHEEO manual: Total coliforms, faecal coliforms |
| 666 | Tree plantation in Water Treatment Tlant Premises |
| 667 | 1)Polyalthia (Polyalthia Longifolia) |
| 668 | 2)Indian Date (Phoenix sylvestris) |
| 669 | TOTAL CARRIAGE |
| 670 | Aggregate |
| 671 | cement |
| 672 | Bricks |
| 673 | OPERATION & MAINTENANCE FOR 5 YEARS |
| 674 | Operation and Maintenance for 1st Year |
| 675 | Operation and Maintenance for 2nd Year |
| 676 | Operation and Maintenance for 3rd Year |
| 677 | Operation and Maintenance for 4th Year |
| 678 | Operation and Maintenance for 5th Year Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail