| 1 | BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: REPAIR/ MAINT OF 33/11KV HT NETWORK FOR DISTRIBUTION TRANSFORMER AT NORTHERN PART OF GARRISION UNDER GE (UTILITIES) UDHAMPUR Contract No: CWE/U(U)- 41/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Dismantling existing ACSR conductor of any size/type from PCC/Steel poles including taking down MS works such as cross arms, clamps, hooks, stay etc from overhead line complete all as specified and directed by Engineer-in-Charge. |
| 3 | Taking down/Removing existing PCC/Steel poles from site complete all as specified and directed by Engineer-in- Charge. Note: Damaged poles shall be removed from site as per direction of Engineer-in- charge |
| 4 | Taking down existing unserviceable HT cable complete for replacement all as specified and directed. |
| 5 | Taking down existing old cross arms of MS channel or angle sections etc complete all as specified and directed. |
| 6 | Taking down old unserviceable insulators any type and size from poles including for reuse or removal complete all as specefied and directed. |
| 7 | Taking out old unserviceable GOD vertical/horizontal mounted including insulators and operating mechanism complete all as specified and directed. |
| 8 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed. |
| 9 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and exceeding 1.5 mtr depth and getting out complete all as specified and as directed. |
| 10 | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed. |
| 11 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 12 | M & L for river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning/protection to cable including spreding, levelling and get thick 18cm after hand punning complete all as specified and directed at site. |
| 13 | Material and laying Precast in reinforced Concrete cable covers Class HV, type B-1 flat of size 300mm x 180mm x 40 mm for HT cable all as specefied. |
| 14 | M & L PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation for poles, filling of mass concrete complete all as specified and as directed. |
| 15 | M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping for old and new poles including form work complete all as specified and as directed . |
| 16 | Supply, laying and testing HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 11000 volts grade (earthed) cross sectional area 95 Sqmm 3 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles complete all as specefied and directed. |
| 17 | Supply, laying and testing HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 11000 volts grade (earthed) cross sectional area 120 Sqmm 3 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles complete all as specefied and directed. |
| 18 | Supply, laying and testing HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 11000 volts grade (earthed) cross sectional area 150 Sqmm 3 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles complete all as specefied and directed. |
| 19 | Supply, lay and fix aerial bunched cable 11kV grade stranded and compact aluminium phase conductor of size 3X120 sqmm + 1X95 sqmm (bare messenger) with aluminium alloy as per IS-8130-1984 ans ISD 398(Part-4)-1949. The phase conductor shall be insulated with XLPE compound Aluminium as per IS-14255-1995 & IS-7098(part-2)-1985 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, including end joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed. |
| 20 | Supply, laying and testing HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 33000 volts grade (earthed) cross sectional area 120 Sqmm 3 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles complete all as specefied and directed. |
| 21 | Supply, laying and testing HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 33000 volts grade (earthed) cross sectional area 185 Sqmm 3 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles complete all as specefied and directed. |
| 22 | M&L for heat shrinkable type end termination joint kit indoor type suitable for XLPE insulated HT cable 11000 Volts grade of size 120 to 185 Sqmm 3 core complete with jointing material and acessories alongwith testing after jointing including taking out the old unserviceable joint kit complete all as specefied and directed. |
| 23 | M&L for heat shrinkable type end termination joint kit outdoor type suitable for XLPE insulated HT cable 11000 Volts grade of size 120 to 185 Sqmm 3 core complete with jointing material and acessories alongwith testing after jointing including taking out the old unserviceable joint kit complete all as specefied and directed. |
| 24 | M&L for heat shrinkable straight through joint kit suitable for XLPE insulated HT cable 11000 Volts grade of size 120 to 185 Sqmm 3 core complete with jointing material and acessories alongwith testing after jointing including taking out the old unserviceable joint kit complete all as specefied and directed. |
| 25 | M&L for heat shrinkable end termination joint kit suitable for XLPE insulated HT cable 33000 Volts grade of size 120 to 185 Sqmm 3 core complete with jointing material and acessories alongwith testing after jointing including taking out the old unserviceable joint kit complete all as specefied and directed. |
| 26 | M&L for heat shrinkable straight through joint kit suitable for XLPE insulated HT cable 33000 Volts grade of size 120 to 185 Sqmm 3 core complete with jointing material and acessories alongwith testing after jointing including taking out the old unserviceable joint kit complete all as specefied and directed. |
| 27 | M&L for MS works, cross arms, bracing, support clamps and back plate fabricated out of structural steel sections including nuts, bolts and washers, welding, bending hot or cold, cutting, drilling holes for bolts in any shape or size as directed and including one coat of red oxide primer, one under coat and one finishing coat of aluminium paint paint completet all as specified and directed. |
| 28 | Supply, fixing in replacement , testing and commissioning in replacement air break isolating switch tripple pole mechanically operated with vertical isolation, 12 insulators mounted on steel frame with operating mechanism worked from ground level and including operating rod of 25 mm dia medium grade GI pipe and locking arrangement of capacity 400 Amps 11 KV with drop out fuse set including making all incoming/outgoing connection of HT cable and ocerhead conductor using new leads and nuts, bolts etc and painting of steel work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 29 | Supply, fixing in replacement , testing and commissioning in replacement air break isolating switch tripple pole mechanically operated with horizontal isolation, 12 insulators mounted on steel frame with operating mechanism worked from ground level and including operating rod of 25 mm dia medium grade GI pipe and locking arrangement of capacity 200 Amps 33 KV with drop out fuse set including making all incoming/outgoing connection of HT cable and ocerhead conductor using new leads and nuts, bolts etc and painting of steel work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 30 | Suppling and fixing in replacement erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-55, 11.0 mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole, complete all as specified and directed by Engr-in-Charge. Note : Excavation and Earth Work ,PCC in foundation shall be measured and paid for separately. |
| 31 | Supply and fixing lightning arrestors gapless metal oxide type complete with all fittings, suitable for 11000 volts grade transmission class, discharge capacity 65 KA including brackets, clamps, nuts, washers and connecting to 4 mm dia GI earth wire complete all as specefied and directed. |
| 32 | M&L for danger notice plate of 1.6 mm thick mild steel sheet vitreous, enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25x3m MS flat, bolts and nuts for HT 25x20cm size complete all as specified and directed |
| 33 | Supply and Fixing for galvanised iron tubing 100 mm dia light grade with all fitting laid under floor/road crossing or in trenches or fixed to pole /walls with with clamps as required including sealing of pipe ends with apporoval sealing compound etc complete all as specified and as directed. |
| 34 | Supply, stringing and fixing ACSR conductor of any type/size on existing poles including fixing to insulators with binding wire or aluminium taps complete all as directed . |
| 35 | Supply & Fix 11000 volts grade disc type insulator porcelain vitreous 145mm heigh 255mm dia ball and socket type white or brown or green with tension clamps complete . |
| 36 | Supply & Fix pin type porcelain vitreous white or brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade. |
| 37 | Relaying old serviceable cable HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium condutctor, 11000 volts grade cross sectional area 95/120 Sqmm, 3 core retrieved from item No 3 complete all as specified and directed. |
| 38 | M&L for painting of steel tubular pole 11.0 m long, by applying two coat of alluminum paint after scraping/brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 m height from ground level and balance 1.5 m from ground level will be painted by alternate layer of red and white enammelled paint ( 30 cms each) pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed. |
| 39 | Supply and fixing PG clamp die cast aluminium of suitable size of over head line of ACSR conductor connections for PT's CTs isolators connection etc all as specefied and directed. |
| 40 | M & L for earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 32x6mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete.Note : GI strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately. |
| 41 | S&F in replacement earth continuity conductor on main earthing lead fixed to pole or buried in ground or at any other situation for loop earthing extra as required (beyond 7.5 M) of GI Strip 32 x 6 mm complete all as specified and directed by Engr-in-Charge. |
| 42 | M&L for filling crushed/broken aggregate of gauge exc 40 mm and not exc 80 mm in layer thickness 150 mm laid in sub station yard complete all as specefied and as directed. |
| 43 | Surface excavation in soft/loose soil in exc 30 cm deep and averaging 15 cm deep and getting out for surface dressing complete all as directed. |
| 44 | Taking proper shut down in writing and disconnecting up the LT and HT electrical connections from transformer of capacity 63 KVA to 1250KVA, removing from pole structure/platform shifting to near by suitable location by using crane and any other equipment and reconnecting with existing electrical system of HT and LT electric mains including testing complete all as directed by Engr-in-charge. Note; Temp arrangement will be provided by the Contractor. |
| 45 | Dehydration and filtration of existing serviceable transformer oil at site or at factory permisses of any type any capacity any rating transformer till it achieves the required dielectric strength upto 50kv at 2.5mm gap using dehydration plant complete all as specified and directed by Engr-in-charge |
| 46 | M&L for complete draining out the transformer oil from radiators after closing the inlet valve from main body of 63 kVA to 3150 kVA and refilling new transformer oil of good quality having not less than 55 KV dielectric strength having low viscosity all as per IS 335 of 1983 all as specified and testing of Transformer after filling new oil complete upto 10Hrs minimum as per entire satisfaction of Engr-in-charge. |
| 47 | Shifting of transformer of capacities (63KVA-1250KVA) from the premises of JNE & CHNC Premises to workshop for necessary repairs Reshifting the transformer Post repairs from workshop to JNE&CHNC Premises with help of hydra/crane/any other lifting devices. |
| 48 | M&L for Rewinding of HT/LT coil confirming to the original winding of the transformer of capacity 63kVA- 160kVA with supper enamelled copper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete, all as specified and directed. |
| 49 | M&L for Rewinding of HT/LT coil confirming to the original winding of the transformer of capacity 200kVA-315kVA with supper enamelled copper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete, all as specified and directed. |
| 50 | M&L for Rewinding of HT/LT coil confirming to the original winding of the transformer of capacity 315kVA- 500kVA with supper enamelled copper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete, all as specified and directed. |
| 51 | M&L for Rewinding of HT/LT coil confirming to the original winding of the transformer of capacity 1250kVA-3150kVA with supper enamelled copper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete, all as specified and directed. |
| 52 | M&L for Rewinding of HT/LT coil confirming to the original winding of the transformer of capacity 6350kVA with supper enamelled copper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete, all as specified and directed. |
| 53 | Re-conditioning of LT Coil complete of copper strip/wire any gauge size by providing and wrapping net insulation after removal of old defective insulation and cleaning complete, all as specified and directed by Engr-in-charge. |
| 54 | Taking down old U/S HT Bushing, Supply & fix HT poreceline bushing complete with brass / tinned copper rod with nuts and gasket set complete for following cap transformer:- |
| 55 | 63 KVA to 125 KVA capacity |
| 56 | 150 KVA to 250 KVA capacity. |
| 57 | 315 KVA to 400 KVA capacity. |
| 58 | 500 KVA to 1250 KVA capacity. |
| 59 | Supply only LT porecelain bushing complete with brass/tinned copper rod with nuts and gasket set complete for following cap transformer:- |
| 60 | 63 KVA to 125 KVA capacity |
| 61 | 150 KVA to 250 KVA capacity. |
| 62 | 315 KVA to 400 KVA capacity. |
| 63 | 500 KVA to 1250 KVA capacity. |
| 64 | S&F Silca gel in repalcement (for transformer of any type/cap) complete with end fitting as directed by Engr-in-charge. |
| 65 | Breather assembly complete with silica gel crystal impregnated with cobalt suitable for any model of transformer rating 1250 KVA to air column of conservator tank in replacement, complete all as specified and directed. |
| 66 | Breather assembly complete with silica gel crystal impregnated with cobalt suitable for any model of transformer rating from 160KVA to 500 KVA to air column of conservator tank in replacement, complete all as specified and directed. |
| 67 | M&L For surface Dressing / cleaning of various 11KV/33kV sub-stations free from vegetation of any type including trimming of tree branches, bushesh creepers etc,complete all as specified & Directed Note : The frequency of surface dressing shall not be less than 2 month |
| 68 | M&L for trimming of tree branches upto 75mm dia to clear the route of HT/LT over head conductors in switch yards and open joints upto 3m from the conductor including removing the cut branches from site and depositing at places n nex 50m all as directed by Engineer-in-charge Note:- 1. One/more tree branches covering 3m shall be considered as one unit. 2. The frequency of trimming of tree branches shall not be less than 2 months) |
| 69 | M&L for Disconnecting and taking down old unserviceable control cable any size any description and supply, fixing, testing and commissioning of LT 1100 volts 2.5 Sqmm 4 core copper conductor armoured cable connecting the cable in positioning properly by providing suitable new copper lugs GI bolts & Nuts washers etc complete all as specified and directed. |
| 70 | M&L for Disconnecting and taking down old unserviceable control cable any size any description and supply, fixing, testing and commissioning of LT 1100 volts 2.5 Sqmm 16 core copper conductor armoured cable connecting the cable in positioning properly by providing suitable new copper lugs GI bolts & Nuts washers etc complete all as specified and directed. |
| 71 | M&L for Disconnecting and taking down the unserviceable/damaged/non operational existing lightening arrestor of 33KV Switching yard and supply , fixing & testing and commissioning of new lightening arrestor 33KV, 10KA suitable for 33KV and maximum voltage of 36KV for (MRS) with solid earthed natural system comprising of Metal oxide elements suitable for ACSR Conductor alongwith the insulating base structural work and all as specified and directed. |
| 72 | M&L for Disconnecting and taking down 33 KV Air break swich gang operated outdoor type any Amps repair of folloing parts and refixing the same all as specified and directed by Engineer-in-Charge :- |
| 73 | Male contact for AB Swicth |
| 74 | Female contact for AB Swicth |
| 75 | Blade for AB Switch |
| 76 | Insulater for 33 KV Pin type |
| 77 | IInsulater for 33 KV Disc type |
| 78 | Servicing of 11 KV GOD rewinding of all jumper of 11 KV two/four pole structure including provision of new binding wire, insulator and DO fuze applying one coat of silicon grease and complete painting of one coat aluminium paint on all connected cross arms, clamps etc complete all as specified and directed. |
| 79 | Gasket set of synthetic rubberized cork sheet with suitable holes for any model transformer rating 1250 KVA complete all as specified and directed. |
| 80 | Gasket set of synthetic rubberized cork sheet with suitable holes for any model transformer rating upto 63 KVA to 500 KVA complete all as specified and directed. |
| 81 | M&L for Taking proper shut down and disconnecting up the LT and HT electric mains from transformer to removing the lid/cover for inspection at site and to facilitate minor repairs after draining out the transformer oil reassembling the transformer refilling the transformer oil (new or old) installing, commissioning and testing at site complete all as specified and directed.Note: All the parts required to be replaced shall be measured and paid separately. |
| 82 | 63 KVA to 125 KVA capacity |
| 83 | 150 KVA to 250 KVA capacity. |
| 84 | 315 KVA to 400 KVA capacity. |
| 85 | 500 KVA to 1250 KVA capacity. |
| 86 | M&L for Painting to transformer including disconnecting the all electrical connection from the following transformer by taking written shut down from power house scrubbing the transformer with hammery paper till old paint removed painting work is completed with spray gun as per existing colour etc. complete all as specified and as directed. |
| 87 | 63 KVA to 125 KVA capacity |
| 88 | 150 KVA to 250 KVA capacity. |
| 89 | 315 KVA to 400 KVA capacity. |
| 90 | 500 KVA to 1250 KVA capacity. |
| 91 | Cable route indicator for MES LT/HT/UG cable of 11KV and route of cable with arrow (Embossed or engraved) made of RCC in suitable shape and fixed in in PCC block 1:3:6 type C-2 of using 40mm aggregate 60cmx30cmin ground 30 cm below ground level and 30 cm above ground to show clear indication, complete all as specified and directed. |
| 92 | M&L in replacement Stay assembly complete as show in electrical plate no 1 (Loop type insulator, stay wire, excavation and concrete measured separatly) with 16mm dia stay rod complete all as specefied and directed by Engr-in-charge including taking down old U/S same items. |
| 93 | Servicing/maintenance to battery bank inlcuding replacement of lead acid battery 6 Nos 110V DC and other connected spare parts for smooth functioning of battery bank complete all as specified and directed. |
| 94 | M&L for HT feeder pillar box out door type factory made cubical type dust proof,for suitable 11 kV out door type both side opening of size 110x100x60 cm of MS sheet 3.15mm thick power coated machine pressed front opening in two havels with rubber gasket/ bedding, locking arrangement with sliding bolt including aluminium bus bar of size 50x10mm and 80cm long 3 strips mounted on HT insulators each strip should be mounted minimum two insulator and nut bolt panel shall be mounted on angle iron frame and legs made from angle iron of size 50x50x6mm and legs 40cm long duly spray painted internally and externally with two coat of synthetic enamel paint over a coat of red oxide primer grouted in PCC 1:2:4 type 'B' (using 20mm graded stone aggregate complete incoming/outgoing cable provision. |
| 95 | S&F for mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron filltets(for securing wire mesh etc) including all necessary drilling, bolting or reveting etc and similar work confirming to Fe-290 Gde E-165 including two coats of paint as directed with over a coating of red oxide primer all as directed by Engr-In-Charge. |
| 96 | Supply only PVC coated chain link fencing 3.6 mm dia of G I wire and minimum 1 mm thick vinyl coating, 50mm x 50mm mesh size all as approved and directed.Note: (i) The dia meter of the mesh after PVC coating shall be 5.6mm (ii) The PVC coating shall be green in colour(iii)The GI Chain link mesh with PVC coating shall be weighed for the purpose of payment |
| 97 | Fixing only GI wire PVC coated chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed. |
| 98 | Supply only Rubber matting as per ISI mark 1mtrx2mtrx19mm for HT breakers at substation complete all as specified and directed. |
| 99 | M&L for Inspection & Visit the power house for checking the fault occure due to rain, heavy wind and any other breakdown related to 11/33 KV HT line and power house, Rectify the fault at own arrangement and report to JE/Engr in charge after rectifying the fault and proper testing and commissioning of HT line, All minor spare and parts such as nut,bolts,disc and pin insulator, streching of conductor and all other essential accessories required for fault rectification are included in the quoted rates. |
| 100 | S&F of Chequered plates/GI sheet/Cross arms of MS fabricated complete with all accessories viz nut,bolts,washers etc, including taking down complete all as specified and directed by Engineer-in-charge. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |