| Sl. No. | Item Description |
| 1 | BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: REPAIR/ MAINT OF VCB’S / RMU’S ALONGWITH ALLIED SERVICES OF CHNC AND NORTHERN PART OF GARRISON UNDER GE (UTILITIES) UDHAMPUR Contract No: CWE/U(U)- 40/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | M & L for carrying out following on site Tests for 33 / 11 KV 3.15 MVA Transformer of any capacity with required / suitable testing equipment by Qualified and Licensed Personal, Recording Test Results and submitted to GE to keep on record duly signed by all concerned complete all as specified and as directed:[a] IR Test[b] PI[c] Magnetic Balance Test[d] Ratio test[e] Di-electric Test of Oil[f] Short Circuit Test[g] Vector Group[h] Winding Resistance [j] All test to be carried out as per applicable IS. |
| 3 | All as per item No. 01.00 but for 11 kv/ 0.433 KV transformer 1250 KVA |
| 4 | M & L for Repairs / Servicing of 33KV VCB indoor/outdoor type VCB having nominal system voltage 33KV highest system voltage 36KV interrupting capacity, frequency 50Hz, short circuit current 25KA, control circuit voltage 110V DC, of ABB make and comprising of the following complete all as specified and as directed:[a] Cleaning of Vacuum Interrupter Limbs for Dust, Oxidising and Decarbonising with CTC.[b] Repair / Servicing of Spring Loaded Operating Mechanism[c] Repair / Servicing of Spring Charging Motor [d] Checking, repairing & servicing of Gearbox, Auxiliary Switches, Spring, Limit Switch etc. complete[e] Checking & Repairing Electrical and Mechanical Operations[f] Checking & Repairing Remote Closing and Tripping of VCB from 33KV Control Panel.[g] Lubrication all Moving Parts with Petroleum Jelly & cleaning all Bushing Insulators with CTC[h] Tightening of all Mechanical Connections of Mechanism[i] Tightening of all HV and LV Connection of VCB. Note: Spares required for Servicing / Repairing of 36 KV Circuit Breaker shall be measured and separately under respective items of this BoQ at supply only rates. |
| 5 | M & L for Repairs / Servicing of 11KV VCB indoor type with hallow porcelain insulated porcelain clad VCB having nominal system voltage 11KV highest system voltage 36KV interrupting capacity, frequency 50Hz, short circuit current 25KA, control circuit voltage 110V DC, of ABB make and comprising of the following complete all as specified and as directed:[a] Cleaning of Vacuum Interrupter Limbs for Dust, Oxidising and Decarbonising with CTC.[b] Repair / Servicing of Spring Loaded Operating Mechanism[c] Repair / Servicing of Spring Charging Motor [d] Checking, repairing & servicing of Gearbox, Auxiliary Switches, Spring, Limit Switch etc. complete[e] Checking & Repairing Electrical and Mechanical Operations[f] Checking & Repairing Remote Closing and Tripping of VCB from 33KV Control Panel.[g] Lubrication all Moving Parts with Petroleum Jelly & cleaning all Bushing Insulators with CTC[h] Tightening of all Mechanical Connections of Mechanism[i] Tightening of all HV and LV Connection of VCB. Note: Spares required for Servicing / Repairing of 36 KV Circuit Breaker shall be measured and separately under respective items of this BoQ at supply only rates. |
| 6 | Tripping latch Assembly for 33 KV Indoor SF6 Breaker of make ABB as per existing model complete all as specified and as directed. |
| 7 | Closing latch Assembly for 33 KV Indoor SF6 SF6 Breaker of make as per existing model complete all as specified and as directed. |
| 8 | Closing coil 110/220V for 33 KV Indoor SF6 Breaker of make ABB as per existing model complete all as specified and as directed. |
| 9 | Triping coil 110/220V for 33 KV Indoor SF6 Breaker of make ABB as per existing model complete all as specified and as directed. |
| 10 | Closing Spring Assembly for 33 KV Indoor SF6 Breaker of make ABB as per existing model complete all as specified and as directed. |
| 11 | Triping Spring Assembly for 33 KV Indoor SF6 Breaker of make ABB as per existing model complete all as specified and as directed. |
| 12 | Limit Switch with bracket complete for 33 KV Intdoor SF6 Breaker of make ABB as per existing model complete all as specified and as directed. |
| 13 | Supply & fix in replacement following spares suitable for 11 KV Intdoor Vacuum Circuit Breaker of Make: Crompton Greaves model No OVB-VBF 11 complete all as specified and as directed. |
| 14 | Closing coil 110/220V for 11 KV Indoor VCB of make Crompton Greaves as per existing model complete all as specified and as directed. |
| 15 | Auxillary contact for 11 KV Intdoor VCB of make Crompton Greaves as per existing model complete all as specified and as directed. |
| 16 | Charging Spring for 11 KV Indoor VCB of make Crompton Greaves as per existing model complete all as specified and as directed. |
| 17 | L-Liver for 11 KV Indoor VCB of make Crompton Greaves as per existing model complete all as specified and as directed. |
| 18 | main Shaft for 11 KV Indoor VCB of make Crompton Greaves as per existing model complete all as specified and as directed. |
| 19 | Gear Assembly for 11 KV Indoor VCB of make Crompton Greaves as per existing model complete all as specified and as directed. |
| 20 | Triping coil 110/220V for 11 KV Indoor VCB of make Crompton Greaves as per existing model complete all as specified and as directed. |
| 21 | Spring Charging motor 110/220V for 11 KV Indoor VCB of make Crompton Greaves as per existing model complete all as specified and as directed. |
| 22 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5 mtr in depth for laying of cables and getting out of excavated material complete all as specified and directed. |
| 23 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and exceeding 1.5 mtr depth and getting out complete all as specified and as directed. |
| 24 | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed. |
| 25 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 26 | M & L for river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning/protection to cable including spreding, levelling and get thick 18cm after hand punning complete all as specified and directed at site. |
| 27 | Material and laying Precast in reinforced Concrete cable covers Class HV, type B-1 flat of size 300mm x 180mm x 40 mm for HT cable all as specefied |
| 28 | M & L PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation for poles, filling of mass concrete complete all as specified and as directed |
| 29 | M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping for old and new poles including form work complete all as specified and as directed by Engineer-in-Charge. |
| 30 | Taking down existing unserviceable HT cable complete for replacement all as specified and directed. |
| 31 | Supply, laying, jointing and testing in replacement of HT XLPE insulated ,screened,PVC bedded galvanised steel strip or wire armoured ,electric power cables(heavy duty) with aluminium conductor,11000 volts (earthed) , grade cross sectional area 95 sqmm 3 core for working voltage upto 11000 Volts, including cable lugs for providing connections as in repair complete all as specified and as directed. |
| 32 | Supplying, laying, testing and connecting in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable of size 120 sqmm 3 core (heavy duty) with multistranded aluminum conductors, 11 KV grade,IS 7098 (Part-2) 2011 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI, HDPE pipe / fixed to pole etc or against re-routing / diversion from residential buildings/ road/ footpath etc, including jointing & testing complete all as specified and directed by Engr In Charge. |
| 33 | Supply, laying and testing HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 11000 volts grade (earthed) cross sectional area 150 Sqmm 3 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles complete all as specefied and directed. |
| 34 | Supply, laying and testing HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 33000 volts grade (earthed) cross sectional area 185 Sqmm 3 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles complete all as specefied and directed. |
| 35 | Maintenance and complete overhauling of 33 KV VCB Make: ABB (CHNC) including disassembling of operating mechanism parts, well cleaning with petrol & CRC-226 and reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts and components etc complete all as specified and directed by Engr-in-Charge.Note: (i) Spare parts will be measured and paid separately as under relevant items as supply only. The labour charges for fixing shall be included in this item. |
| 36 | Maintenance and complete overhauling of 11 KV VCB Make: Crompton(CHNC) including disassembling of operating mechanism parts, well cleaning with petrol & CRC-226 and reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts and components etc complete all as specified and directed by Engr-in-Charge.Note: (i) Spare parts will be measured and paid separately as under relevant items as supply only. The labour charges for fixing shall be included in this item. |
| 37 | Maintenance and complete overhauling of 11 KV VCB Make: ABB(JNE) including disassembling of operating mechanism parts, well cleaning with petrol & CRC-226 and reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts and components etc complete all as specified and directed by Engr-in-Charge.Note: (i) Spare parts will be measured and paid separately as under relevant items as supply only. The labour charges for fixing shall be included in this item. |
| 38 | Maintenance and complete overhauling of 11 KV VCB Make: Schneider (JNE) including disassembling of operating mechanism parts, well cleaning with petrol & CRC-226 and reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts and components etc complete all as specified and directed by Engr-in-Charge.Note: (i) Spare parts will be measured and paid separately as under relevant items as supply only. The labour charges for fixing shall be included in this item. |
| 39 | M&L for Closing shaft assembly of existing rated VCB having spring operated through shunt motor and triped through push button with spring and close strips indoor type 11 KV VCB in replacement, complete all as specified and directed. |
| 40 | TNC switch/(Tripping neutral & closing) of existing specifications and make with coil suitable for 11 KV VCB 1250 Amps in replacement, complete all as specified and directed. |
| 41 | Over current/Earth fault relay Numerical 3 Pole, OC/EF Protection Relay ,Model:- ADR 131A, suitable for 11 KV VCB in replacement, complete all as specified and directed. |
| 42 | Push Button Bracket assembly of existing specifications and make suitable for 11 KV VCB in replacement, complete all as specified and directed. |
| 43 | Charged/Discharged indicator assembly of existing specifications and make suitable for 11 KV VCB in replacement, complete all as specified and directed. |
| 44 | Triping spring assembly of existing specifications and make suitable for 11 KV VCB in replacement, complete all as specified and directed. |
| 45 | Trip shaft assembly of existing specifications and make with spring and trip strips suitable for 11 KV VCB in replacement, complete all as specified and directed. |
| 46 | Current transformer of capacities 150/75/1/1A suitable for 33 KV VCB of existing Complete all as specified and directed. |
| 47 | Current transformer of capacities 600/300/5/5A suitable for 11 KV VCB of existing Complete all as specified and directed. |
| 48 | Current transformer of capacities 400/200/5/5A suitable for 11 KV VCB of existing Complete all as specified and directed. |
| 49 | Current transformer of capacities 200/100/5/5A suitable for 11 KV VCB of existing Complete all as specified and directed. |
| 50 | Current transformer of capacities 100/60/5/5A suitable for 11 KV VCB of existing make. Complete all as specified and directed. |
| 51 | Indicatior lamp LED type in Red, Blue, Green and White colour 50 volts/110 volts suitable for 11KV VCB's in replacement, complete all as specified and directed. |
| 52 | HRC fuse up to 32 Amp ISI marked type - FI RNSH-32 suitable for 11 KV VCB in replacement, complete all as specified and directed. |
| 53 | Petrolium jelly on GOD after removing carbon, dust etc complete all as specified and directed. |
| 54 | Servicing of 11 KV GOD rewinding of all jumper of 11 KV two/four pole structure including provision of new binding wire, insulator and DO fuze applying one coat of silicon grease and complete painting of one coat aluminium paint on all connected cross arms, clamps etc complete all as specified and directed. |
| 55 | Drawing out the SF6/RMU/from the Circuit system of 11KV, Servicing the Circuit breaker by checking the following parameters for proper funcationing using CTC for clear off the carbon deposited. |
| 56 | Checking / fault diagnisis of isolator & earth switch mechanism slips |
| 57 | Checking of gas inside the tank |
| 58 | Checking the funcationality of relay protection system |
| 59 | Checking the Mechanism of isolator module and VCB module. |
| 60 | Checking the voltage presence indicator. |
| 61 | Checking the complete control wiring for tripping/closing/indication system necessary spare parts shall be measured as supply only in following items Note: a) Servicing shall be performed by authoriesed service personnel of M/S ABB b) Servicing certificate shall be provided to engineer-in-charge c) replacement of minor spares like push button lever. Green push button, red push buttons and shaft for operating handles are inclusive of rate quoted by tenderer. |
| 62 | Supply only Spare parts of SF6/RMUs 630A |
| 63 | 3PKE Mechanism w/o hex rod for islators module |
| 64 | 2 PA Mechanism w/o hex rod for VCB Module |
| 65 | Ashida ADR241S NANO Relay |
| 66 | Voltage Presence Indicator (Capacitor unit & Chord) |
| 67 | Gas for RMU Tank. |
| 68 | CT 200/100/5/5A |
| 69 | CT 400/200/5/5A |
| 70 | V module push button bracket |
| 71 | M&L for heat shrinkable type end termination joint kit indoor type suitable for XLPE insulated HT cable 11000 Volts grade of size 120 to 185 Sqmm 3 core complete with jointing material and acessories alongwith testing after jointing including taking out the old unserviceable joint kit complete all as specefied and directed. |
| 72 | M&L for heat shrinkable type end termination joint kit outdoor type suitable for XLPE insulated HT cable 11000 Volts grade of size 120 to 185 Sqmm 3 core complete with jointing material and acessories alongwith testing after jointing including taking out the old unserviceable joint kit complete all as specefied and directed. |
| 73 | M&L for heat shrinkable straight through joint kit suitable for XLPE insulated HT cable 11000 Volts grade of size 120 to 185 Sqmm 3 core complete with jointing material and acessories alongwith testing after jointing including taking out the old unserviceable joint kit complete all as specefied and directed. |
| 74 | Scrapping , cleaning and preparation of old surfaces of steel tubular pole (11 mtr long) including painting channel, angel, clamp, nuts and bolts washer etc steel fitting complete and M&L for painting with one coat for aluminium paint after preparation of the steel surfaces by painting with two coat for aluminium paint after preparation of the steel surfaces and as directed by the Engr-in-Charge. |
| 75 | Scrapping , cleaning and preparation of old surfaces of of HT 4 pole structure of any type and size (Steel tubular pole) including all steel/MS fitting and fixture complete and M&L for painting with two coat for aluminium paint after preparation of the steel surfaces and then applied strap with two coats black & white paint in strip alternatively all round the poles from the bottom of the pole for indication of the poles. Height of the strap shall be 30 cm and number of strap shall be 05 Nos and writing Sub Stn No/feeder name with white luminaire paint of letter size 75 mm complete andcomplete all as directed by Engr-in-Charge. |
| 76 | Scrapping , cleaning and preparation of old surfaces of of HT 2/3 pole structure of any type and size (Steel tubular pole) including all steel/MS fitting and fixture complete and M&L for painting with two coat for aluminium paint after preparation of the steel surfaces and then applied strap with two coats black & white paint in strip alternatively all round the poles from the bottom of the pole for indication of the poles. Height of the strap shall be 30 cm and number of strap shall be 05 Nos and writing Sub Stn No/feeder name with white luminaire paint of letter size 75 mm complete and complete all as directed by Engr-in-Charge. |
| 77 | Mateial and labour for applied strap with two coats black and white paint in strap alternatevely all round the poles from the bottom of the pole for indication of the poles. Height of the strap shall be 30 cm and number of strap shall be 05 Nos. |
| 78 | Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 11KV grade stranded and compact aluminium phase conductor of size 3x95 sqmm + 1x70 sqmm (bare messenger) with Aluminium alloy as per IS-8130-1984 ans ISD 398(Part-4)-1979. The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14255-1995 & IS-7098(Part-2)-1985 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed. |
| 79 | Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 11KV grade stranded and compact aluminium phase conductor of size 3x120 sqmm + 1x95 sqmm (bare messenger) with Aluminium alloy as per IS-8130-1984 ans ISD 398(Part-4)-1979. The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14255-1995 & IS-7098(Part-2)-1985 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed. |
| 80 | Taking down/Removing existing PCC/Steel poles from site complete all as specified and directed by Engineer-in- Charge. Note: Damaged poles shall be removed from site as per direction of Engineer-in- charge |
| 81 | Suppling and fixing in replacement erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-55, 11.0 mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole, complete all as specified and directed by Engr-in-Charge. Note : Excavation and Earth Work ,PCC in foundation shall be measured and paid for separately. |
| 82 | Supply and fixing lightning arrestors gapless metal oxide type complete with all fittings, suitable for 11000 volts grade transmission class, discharge capacity 65 KA including brackets, clamps, nuts, washers and connecting to 4 mm dia GI earth wire complete all as specefied and directed. |
| 83 | M&L earthing complete with Copper earth plate electrode 600mmx600mmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of earth plate not less than 1.5 mtrs below normal ground level connected with copper earth strip 32mmx6mm thick and copper bolts, nuts, etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnel for watering, connecting to busbar, all as shown in electrical plate No.3 of SSR Part I incl necessary earth work and excavation in any type of soil, PCC earth chamber with RCC cover slab, salt, charcoal and MS hook, ane provn of test point complete. NOTE : copper strip 20x3mm upto 7.5 Mtrs with 40mm protection pipe shall be included in quoted rates and beyond 7.5 mtrs shall be measured and paid separately. |
| 84 | S&F Copper strip 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground |
| 85 | M & L for earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 32x6mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete.Note : GI strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately. |
| 86 | S&F in replacement earth continuity conductor on main earthing lead fixed to pole or buried in ground or at any other situation for loop earthing extra as required (beyond 7.5 M) of GI Strip 32 x 6 mm complete all as specified and directed by Engr-in-Charge. |
| 87 | M&L for Disconnecting, opening of VCB (Make : Schneider) of any description and any make of rating 11 KV 400 Amps capacity for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing and its testing complete all a specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in these item. (ii) Servicing shall be got carried out by the authorised rep of the VCB manufacturer and the service engineer will submit a service report for each VCB. (iii) Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted. |
| 88 | Supply only following items/spare parts suitable for 11KV VCB, Amps capacity of (Make : Schneider) dismantled / fixed under Sch 'A' item No: 39 here-in-before complete all as specified and directed. |
| 89 | Vacuum Interrupter type suitable for 11 KV VCB Panel complete all as specefied and directed. |
| 90 | Isolating contact assembly 12500 Amps suitable for 11 KV VCB Panel complete all as specefied and directed. |
| 91 | Tripping Coil assembly 30 Volts DC suitable for 11 KV VCB Panel complete all as specefied and directed. |
| 92 | Close Coil Coil assembly 30 Volts DC suitable for 11 KV VCB Panel complete all as specefied and directed. |
| 93 | Motor & Gear assembly 110V AC and 220 AC for 11 KV VCB Panel complete all as specefied and directed. |
| 94 | TNC switch for 11 KV VCB Panel complete all as specefied and directed. |
| 95 | Indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC supply. |
| 96 | M&L for filling crushed/broken aggregate of gauge exc 40 mm and not exc 80 mm in layer thickness 150 mm laid in sub station yard complete all as specefied and as directed. |
| 97 | Surface excavation in soft/loose soil in exc 30 cm deep and averaging 15 cm deep and getting out for surface dressing complete all as directed. |
| 98 | M&L for Breather assembly complete with silica gel crystal impregnated with cobalt suitable for any model of transformer rating 63 to 500KVA to air column of conservator tank in replacement, complete all as specified and directed. |
| 99 | M&L for Breather assembly complete with silica gel crystal impregnated with cobalt suitable for any model of transformer rating 1250KVA to air column of conservator tank in replacement, complete all as specified and directed. |
| 100 | S&F Silca gel in repalcement (for transformer of any type/cap) complete with end fitting as directed by Engr-in-charge. |
| 101 | M&L for Disconnecting and taking down the unserviceable/damaged/non operational existing lightening arrestor of 33KV Switching yard and supply , fixing & testing and commissioning of new lightening arrestor 33KV, 10KA suitable for 33KV and maximum voltage of 36KV for (MRS) with solid earthed natural system comprising of Metal oxide elements suitable for ACSR Conductor alongwith the insulating base structural work and all as specified and directed. |
| 102 | M&L for HT feeder pillar box out door type factory made cubical type dust proof,for suitable 33KV out door type both side opening of size 110x100x60 cm of MS sheet 3.15mm thick power coated machine pressed front opening in two havels with rubber gasket/ bedding, locking arrangement with sliding bolt including aluminium bus bar of size 50x10mm and 80cm long 3 strips mounted on HT insulators each strip should be mounted minimum two insulator and nut bolt panel shall be mounted on angle iron frame and legs made from angle iron of size 50x50x6mm and legs 40cm long duly spray painted internally and externally with two coat of synthetic enamel paint over a coat of red oxide primer grouted in PCC 1:2:4 type 'B' (using 20mm graded stone aggregate complete incoming/outgoing cable provision. |
| 103 | S&F for mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron filltets(for securing wire mesh etc) including all necessary drilling, bolting or reveting etc and similar work confirming to Fe-290 Gde E-165 including two coats of paint as directed with over a coating of red oxide primer all as directed by Engr-In-Charge. |
| 104 | Supply only PVC coated chain link fencing 3.6 mm dia of G I wire and minimum 1 mm thick vinyl coating, 50mm x 50mm mesh size all as approved and directed.Note: (i) The dia meter of the mesh after PVC coating shall be 5.6mm (ii) The PVC coating shall be green in colour(iii)The GI Chain link mesh with PVC coating shall be weighed for the purpose of payment |
| 105 | Fixing only GI wire PVC coated chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed. |
| 106 | Material and Labour for construction of platform for transformer 3 M(wide)x 3 m (long) & 1.5m (height) including moorum filling, earth work in brickwork any type of soil, brick work in CM (1:6) and PCC at top 10 cm thick (1:2:4) type B-1 and foundation with 1:4:8 type D-2, 25cm thick all as per drawing including plastering to exposed walls and white wash, providing MS channel on top of size 75x40x8mm of 1.5m length for rolling to transformer, including chain link fencing of wire mesh 150x100 size made out 4mm dia GI wire of height 1.5m fixed with the help of MS strip 25x6mm on and including MS angle iron 75x45x6mm thick 12 Nos post by the means of drilling holes at the distance of 30cm and fixed with the help of suitable nut, bolt and washer, the length of MS angle iron not less than 2.25m top of post bend to the shape of 60 degree including 03 Nos cuts for inserting barbed wire including 03 run of barbed wire and including provision of gate of size 1.5mx0.9m made out of MS angle iron 50x50x6mm and MS bar 12mm dia for meshing to the gate and locking arrangement complete all necessary for work, complete all as specified. |
| 107 | Supply, fixing in replacement , testing and commissioning in replacement air break isolating switch tripple pole mechanically operated with vertical isolation, 12 insulators mounted on steel frame with operating mechanism worked from ground level and including operating rod of 25 mm dia medium grade GI pipe and locking arrangement of capacity 400 Amps 11 KV with drop out fuse set including making all incoming/outgoing connection of HT cable and ocerhead conductor using new leads and nuts, bolts etc and painting of steel work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 108 | M&L for danger notice plate of 1.6 mm thick mild steel sheet vitreous, enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25x3m MS flat, bolts and nuts for HT 25x20cm size complete all as specified and directed |
| 109 | Supply and laying 100 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed. |
| 110 | Supply and laying 80 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed. |
| 111 | M&L for complete draining out the transformer oil from radiators after closing the inlet valve from main body of 1250 KVA,500KVA,250KVA,160KVA,63KVA transformer oil of good quality having not less than 70 KV dielectric strength having low viscosity all as per IS 335 of 1983 all as specified and testing of Transformer after filling new oil complete upto 10Hrs minimum as per entire satisfaction of Engr-in-charge. |
| 112 | M&L for Servicing of 11 KV GOD rewinding of all jumper of 11 KV two/four pole structure including provision of new binding wire, insulator and DO fuze applying one coat of silicon grease and complete painting of one coat aluminium paint on all connected cross arms, clamps etc complete all as specified and directed. |
| 113 | Gasket set of synthetic rubberized cork sheet with suitable holes for any model transformer rating 1250 KVA complete all as specified and directed. |
| 114 | Gasket set of synthetic rubberized cork sheet with suitable holes for any model transformer rating upto 63 KVA to 500 KVA complete all as specified and directed. |
| 115 | M&L for replacement of U/S DC Power pack with battery back up complete enclosed in a sheet metal enclosures size not less than 2mm thick duly compartmentlise for battries, charging system and control system with LED indicator lamps and toggle switch and push button ON/OFF system for charging, discharging etc as per requirement , front openable and lockable with proper ventilaation as per latest IS, suitable for supply of 24 volt DC 100 AH duly banked with 2 volt LED acid maintenance free battries including float and trickle battery charging system suitable for input single phase 220 volt/3 phase 440 volt 50 Hz AC supply including all electrical and control connection upto existing socket for charging and DC Supply to the existing VCBs upto 2 Nos. The connection of incomming and outgoing battery bank to VCBs willl be made by stranded copper conductor size not less than 2.5 sqmm for each core in case of multi core cable or single core cable PVC insulated unsheathed cable duly drawn into medium grade PVC conduit on floor/wall complete all as specified and as directed. Location- Substation-1 |
| 116 | M &L for Opening, maintenance and general servicing of servo voltage stabilizer of capacity 50 KVA and 100 KVA incuding removal of sludge from disserstate coils, buck boost transfomers, tightening of all nuts and bolts, cleaning of stabilzer coils, checking and servicing of servo mechanisam, gear, syncronising system, automatic voltage regulator circuits and other allied electrical components complete all as specefied and directed by Engr-in-charge. Note: a) Voltage stabilizer must be repaired by original manufacturer or by authorised service provider of the company. b) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item c) All T & P and transportaion arrangement are deemed to be included in the rates quoted. |
| 117 | Supply only following parts suitable for three phase servo voltage stabilizer upto 100KVA capacity as per existing make or as recommanded by original stabilizer manufacturer complete all as specified and directed. |
| 118 | Volt Meter (Digital/Analog) |
| 119 | Ampere meter with CT (Digital/analog) |
| 120 | Micro Processor based control card for each phase |
| 121 | Servo synchronizing motor single phase AC 230 Volts, 3 Kg torque |
| 122 | RC Net work for 3 Kg torque servo motor |
| 123 | Carbon Brush of any capacity |
| 124 | M&L in replacement of Aluminium lugs suitable for 630 sqmm cable including taking down the existing unserviceable one, complete all as specified and directed by Engineer-in-charge |
| 125 | All as per Ser Item No 88.00 here-in-before but for 500 sqmm |
| 126 | All as per Ser Item No 88.00 here-in-before but for 400 sqmm |
| 127 | All as per Ser Item No 88.00 here-in-before but for 300 sqmm |
| 128 | All as per Ser Item No 88.00 here-in-before but for 185 sqmm |
| 129 | All as per Ser Item No 88.00 here-in-before but for 150 sqmm |
| 130 | All as per Ser Item No 88.00 here-in-before but for 120 sqmm |
| 131 | All as per Ser Item No 88.00 here-in-before but for 95 sqmm |
| 132 | All as per Ser Item No 88.00 here-in-before but for 70 sqmm |
| 133 | All as per Ser Item No 88.00 here-in-before but for 50 sqmm |
| 134 | All as per Ser Item No 88.00 here-in-before but for 35 sqmm |
| 135 | All as per Ser Item No 88.00 here-in-before but for 25 sqmm |
| 136 | Supply only Rubber matting as per ISI mark 1mtrx2mtrx19mm for HT breakers at substation complete all as specified and directed. |
| 137 | Supply & Fixing Insulation HT Tape of size 25x3mm including taking down the existing unserviceable one, complete all as specified and directed by Engr-in-Charge. |
| 138 | Taking out ACB trolly LT control panel 415 V 3 Phase 600/800 Amp, 50KA,4 Pole and cleaning the ACB with CRC removing all dust, carben etc greasing the mechanical parts gears, lever charging male female contacts and spring holders and testing and calibration for overload current and fault current at 11KV/33KV sub stn complete all as specified and directed. |
| 139 | M&L for inspection & Visit the power house for checking the fault occured due to rain, heavy wind and any other breakdown related to 11/33 KV HT line and power house, Rectify the faullt at own arrangement and report to JE/Engr in charge after rectifying the fault and proper testing and commissioning of HT line, All minor spare and parts such as nut, bolts, disc and pin insulator, streching of conductor and all other essential accessories required for fault rectification are included in the quoted rates. |
| 140 | M&L for stretching/ tightning of loose ACSR conductor including fixing of conductor accessories such as clamp etc as per site condition of Zebra/ Dog/Goat/Panther/Wolf/etc/any type conductor of 11 KV to 33 KV lines. Note : Length of indl conductor shall be measured. |
| 141 | S&F of Chequre plates/GI sheet/Cross arms in replacement of MS fabricated complete with all accessories viz nut,bolts,washers etc, including taking down complete all as specified and directed by Engineer-in-charge. |
| 142 | Supply, fixing in replacement , testing and commissioning in replacement air break isolating switch tripple pole mechanically operated with vertical isolation, 12 insulators mounted on steel frame with operating mechanism worked from ground level and including operating rod of 25 mm dia medium grade GI pipe and locking arrangement of capacity 200 Amps 11 KV with drop out fuse set including making all incoming/outgoing connection of HT cable and ocerhead conductor using new leads and nuts, bolts etc and painting of steel work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 143 | Dismantling of overhead ACSR (Aluminium conductor steel reinforced) from existing electric pole and removing unserviceable ACSR from Site complete all as directed. |
| 144 | Supplying and fixing, Stretching, Securing, Connecting & testing of Aluminium Conductor Steel Reinforced (ACSR) of size Zebra/ Dog/Goat/ Panther/Wolf/mink for 11 KV to 33 KV over head lines complete including taking out old unserviceable conductor complete all as directed and specified by Engr In Charge. |
| 145 | Dismantling of existing GI earth/guard wire of any Size and removing unserviceable GI wire from Site complete all as specified and as directed. |
| 146 | Suplying and fixing as in replacement GI Stranded continous earth wire/ surge wire of 7/2.24 mm on 11 KV to 33 KV line at road crossing including of special Tools and plant , manpower required at site complete all as directed by Engr-in -charge.Note : -(i) Length of span is approx 60 to RM.(ii) Due care is to be given while replacement of earth wire that there should no damage to over head line conductor/pole. In case due to any negligence, damage is caused to be make good/renewal by the contractor from his own resources and nothing extra is admissible.(iii) All Safety to labourer must be adhered by the contractor during execution of work. |
| 147 | Dismantling of insulator of any type and Size from existing poles after opening nuts, bolts and removing from Site all as directed. |
| 148 | M&L for heat shrinkable type end termination joint kit outdoor type suitable for XLPE insulated HT cable 33000 Volts grade of size 120 to 185 Sqmm 3 core complete with jointing material and acessories alongwith testing after jointing including taking out the old unserviceable joint kit complete all as specefied and directed. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |