| 1 | Taking down carefully aluminium point wiring (light, fan, socket, bell or power), complete with fitting such as switches, ceiling roses, lamp holders, sockets, regulators, call bell light fitting with PVC casing capping/conduit surface /concealed or wooden pattens including sunken cast iron /pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces all as specified and directed by Engineer in charge. |
| 2 | M&L for point wiring with single core PVC insulated unsheathed stranded FRLS of size 1.5 Sqmm multistranded copper conductor cable 1100 Volts grade drawn into concealed PVC conduit of suitable size with all fitting and fixing accessories, including MS sunken terminal boxes (ISI Marked) concealed in wall, suitable for mounting of modular switches, sockets and fan regulators etc, with modular cover plate, frame, all fittings and fixing accessories, and PVC FRLS insulated 1.5 Sqmm multistranded copper conductor cable as earth continuity wire connected to earth dolly, including cutting chases, pinning in cement mortar, plastering, making good the disturbed surfaces to match with the existing surface complete all as specified and directed by Engineer-in-Charge.(a) one light/ceiling/exhaust fan point controlled by one switch. |
| 3 | (b) All as per item No.2 here in before but one socket point controlled by one switch on same board. |
| 4 | (c) All as per item No.2 here in before but one socket point controlled by one switch on Independent board. |
| 5 | (d) All as per item No.2 here in before but with 1100 volts grade PVC insulated FRLS multistaranded copper conductor cable of size 2.5 Sqmm (Two runs) including one run of 2.5 Sqmm multistranded copper conductor cable as earth continuity conductor for 6 pin switch socket outlet 15 Amp on independent board complete all as specified and directed by Engineer in charge . |
| 6 | S&F switch piano flush type AC 230 volts 6 Amps single pole one way complete all as specified and directed by Engineer in charge. |
| 7 | S&F socket outlet 2in1 / 3 pin, 6 Amps and AC 230 volts flush type complete all as specified and directed by Engineer in charge. |
| 8 | S&F switch socket combination outlet, 5 pin, 6 Amps, multipurpose, flush type, non shutter, non inter locking type, 230 volt, white/ivory finish with fixing hole complete all as specified and directed by Engineer in charge. |
| 9 | S&F in switch socket combination, 5 in 1, 16Amps, multipurpose , flush type, shutter type, 230 volt, white/ivory finish with fixing hole complete all as specified and directed by Engineer in charge. |
| 10 | S&F in replacements 10W LED Pride ultra/NXT, 6500k, 220V, White, with extruded polycarbonate, environmental friendly & energy efficient this linear profile LED lighting fixture provides uniform illumination for brighter light, including taking down old unserviceable light fittings, complete all as specified and as directed. Make-Havells Model No. LHEXAZP7PN1W010 or equivalent in Philips/Bajaj/Crompton as approved by GE. |
| 11 | S&F in replacements 20W Pride Essential Batten, 6500k, 220V, White, Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, uniform illumination for brighter light, environmental friendly, energy efficient, including taking down old unserviceable light fittings, complete all as specified and as directed. Make-Havells Model No. LHEXAWP7UN1W020 or equivalent in Philips/Bajaj/Crompton as approved by GE. |
| 12 | S&F in replacements 06W LED Panel Round, 6500K, slim compact, aluminum die cast edge LED recess mounted round downlight fixture panel fitting with separate electronic driver, opal diffuser for glare free even light distribution, including taking down old unserviceable light fittings, complete all as specified and directed. Make- Havells/Philips/ crompton/Bajaj as approved by GE. |
| 13 | S&F in replacements 12W LED Panel Round, 6500K, slim compact, aluminum die cast edge LED recess mounted round downlight fixture panel fitting with separate electronic driver, opal diffuser for glare free even light distribution, including taking down old unserviceable light fittings, complete all as specified and directed. Make- Havells/Philips/ crompton/Bajaj as approved by GE. |
| 14 | S&F in replacements for LED light fitting 1 x 9W / 1 x 10W Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size with LED Lamp 1 x 9/10watts, including taking down old unserviceable light fittings, complete all as specified and directed. |
| 15 | S&F in replacements for Decorative wall light fixture made up of Polycarbonate, suitable for 1 x 9 Watts, retrofit LED lamp, B22 base, CITY-1, 220 Volts, AC, including taking down old unserviceable light fittings complete all as specified and as directed. Make: Havells, Cat part No. CITY-1, code no. LHDL05160099/ or equivalent in Philips/Bajaj/Crompton as approved by GE. |
| 16 | S&F in replacements 40W LED Panel Square, 6500K, slim compact, aluminum die cast edge LED recess mounted square downlight fixture panel fitting with separate electronic driver, opal diffuser for glare free even light distribution and fixture size 600 x600mm suitable for roof ceiling, including taking down old unserviceable light fittings, complete all as specified and directed by Engineer in charge. |
| 17 | S&F in replacements LED light fitting mirror type with high output diffuser, 10 watt, 220 V, AC decorative type with driver and connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable light fittings, complete all as specified and directed by Engineer in charge. |
| 18 | S&F in replacements LED light fitting 35 watt building security lights, 230 Volts, outdoor type & Wide temperature operating range: -10 °C to +50 °C, with best in class design & roubst heat sink for better heat dissipation, electronic driver unit with IP 65/66 protection, lamp bracket with impact and corrosion resistant necessary mounting bolts, nuts and washers, fixing on iron angle including taking down old unserviceable light fittings, complete all as specified and directed. |
| 19 | S&F in replacements stepped type electronic fan regulator 230V, single/Double module 120/280Watt, flush type including taking down old existing unserviceable, complete all as specified and directed by Engineer in charge.. |
| 20 | S&F in replacements socket outlet 2in1 / 3 pin, 6 Amps and AC 230 volts flush type including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 21 | S&F in replacements switch socket combination outlet, 5 pin, 6 Amps, multipurpose, flush type, non shutter, non inter locking type, 230 volt, white/ivory finish with fixing hole including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 22 | S&F in replacements switch socket combination outlet, 5 in 1, 16Amps, multipurpose , flush type, shutter type, 230 volt, white/ivory finish with fixing hole including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 23 | S&F in replacements of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including taking down old existing unserviceable complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F in replacements ceiling rose, PVC/polycarbonate insulated body fixed on PVC Block, 3 terminal and 240 volts, ISI marked including taking down old existing unserviceable complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F in replacements switch socket combination, 5 pin, 6 Amps, multipurpose, non shutter, 230 volt, white/ivory finish with PVC Box type including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 26 | S&F in replacements switch socket combination, 5 pin, 6/16Amps, multipurpose , shutter type, 230 volt, white/ivory finish with PVC Box type including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 27 | S&F in replacement switch piano flush type AC 230 volts 6 Amps single pole one way including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 28 | S&F in replacement switch piano flush type AC 230 volts 6 Amps single pole two way including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 29 | S&F in replacement bell push switch piano flush type AC 230 volts 6 Amps single pole including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 30 | S&F in replacement switch piano flush type AC 230 volts 16 Amps single pole one way including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 31 | S&F in replacements socket outlet 2in1 / 3 pin, 6 and 16 Amp AC 230 volts flush type including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 32 | S&F in replacements Modular Switch 1 way 6/10 Amp, 1 module 240 volts 50 Hz including taking down old existing unserviceable complete all as specified and directed. |
| 33 | S&F in replacements Modular Bell push Switch 1 way 6/10 Amp, 1 module 240 volts 50 Hz including taking down old existing unserviceable complete all as specified and directed. |
| 34 | S&F in replacements Modular Switch 1 way 16/20 Amp, 1 module 240 volts 50 Hz including taking down old existing unserviceable complete all as specified and directed. |
| 35 | S&F in replacements Modular socket combined 2/3 pin, 6/10 Amp, 2 module 240 volts 50 Hz, including taking down old existing unserviceable complete all as specified and directed. |
| 36 | S&F in replacements Modular socket combined 2/3 pin, 16/20 Amp, 2 module 240 volts 50 Hz including taking down old existing unserviceable complete all as specified and directed. |
| 37 | S&F in replacements Modular fan regulator rotary type stepped 120/280 watt capacity 1/2 module including taking down old existing unserviceable, complete all as specified and directed. |
| 38 | S&F in replacements plug top three pin, 6 Amps, 240 Volts, ISI Marked complete including taking down old existing unserviceable/broken complete all as specified and directed. Make - Anchor/Havells/Bajaj as approved by GE. |
| 39 | S&F in replacements plug top three pin, 16 Amps, 240 Volts, ISI Marked complete including taking down old existing unserviceable/broken complete all as specified and directed. Make-Anchor/Havells /Bajaj as approved by GE. |
| 40 | S&F in replacements Bell Buzzer, Ding Dong AC, 230 volts single pole including taking down old existing unserviceable complete all as specified and directed by Engineer in charge. |
| 41 | S&F in replacements Modular White cover plate with frame, 3 module including taking down old existing unserviceable/broken complete all as specified and directed. |
| 42 | S&F in replacements Modular White cover plate with frame, 4 module including taking down old existing unserviceable/broken complete all as specified and directed. |
| 43 | S&F in replacements Modular White cover plate with frame, 6 module including taking down old existing unserviceable/broken complete all as specified and directed. |
| 44 | S&F in replacement plastic junctions boxes, round/square (No way/1way/2way/3way /4way) including taking down old existing broken, complete all as specified and directed by Engr-in-charge. |
| 45 | S&F in replacement PVC surface mounting 1 module Gang Box for mounting of switches with fixing accessories, screws etc. Including taking down old existing broken complete all as specified and directed. |
| 46 | S&F in replacement PVC surface mounting 3 module Gang Box for mounting of switches with fixing accessories, screws etc. Including taking down old existing broken complete all as specified and directed. |
| 47 | S&F in replacement MCB SP 240 volts 6 to 32 Amps, 10 KA, 'B' curve complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F in replacement MCB SPN 240 volts 40 to 63 Amps, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge. |
| 49 | S&F in replacement MCB TPN 415 volts 40 to 100 Amps, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge. |
| 50 | S&F in replacement Single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps, 230V, including taking down old unservisible complete all as specified and directed by Engineer-in-Charge. Note: Plug socket capacity shall be not less than 20 Amps. |
| 51 | S&F in replacement sheet metal enclosure MCB DB double door, SPN 240 volts, 8 ways with 200 amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP 43 degree protection for fixing MCBs, including taking down old unservisible broken/rusted DB box, complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F in replacement sheet metal enclosure MCB DB double door, SPN 240 volts, 12 ways with 200 amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP 43 degree protection for fixing MCBs, including taking down old unservisible broken/rusted DB box, complete all as specified and directed by Engr-in-Charge. |
| 53 | S&F in replacement sheet metal enclosure MCB TPN DB double door, 415 volts, 6 ways with 200 amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP 43 degree protection for fixing MCBs, including taking down old unservisible broken/rusted DB box, complete all as specified and directed by Engr-in-Charge. |
| 54 | M/L in repair Sub Main Wiring with two single core PVC FRLS insulated cable of size 4.0 Sqmm multistranded copper conductor cable drawn through PVC casing and caping /conduit of suitable size, with all fixing accessories and 4.0 Sqmm multistrand copper conductor cable as continuous earth wire, including taking down old unservisible cable, complete all as specified and directed by Engineer in charge (Note :- Two Nos of 4.0 Sqmm Wire and One No of 4.0 Sqmm Earth wire in One RM length Measured as one unit length). |
| 55 | M/L in repair Sub Main Wiring with two single core PVC FRLS insulated cable of size 6.0 Sqmm multistranded copper conductor cable drawn through PVC casing and caping /conduit of suitable size, with all fixing accessories and 6.0 Sqmm multistrand copper conductor cable as continuous earth wire, including taking down old unservisible cable, complete all as specified and directed by Engineer in charge (Note :- Two Nos of 6.0 Sqmm Wire and One No of 6.0 Sqmm Earth wire in One RM length Measured as one unit length). |
| 56 | M/L in repair Sub Main Wiring with two single core PVC FRLS insulated cable of size 10.0 Sqmm multistranded copper conductor cable drawn through PVC casing and caping /conduit of suitable size, with all fixing accessories and 10.0 Sqmm multistrand copper conductor cable as continuous earth wire, including taking down old unservisible cable, complete all as specified and directed by Engineer in charge (Note:- Two Nos of 10.0 Sqmm Wire and One No of 10.0 Sqmm Earth wire in One RM length Measured as one unit length). |
| 57 | S&F Ceiling Fan 1200 mm sweep copper wound, single phase 230 Volts, including down rod, clamps and accessories, min air delivery 210 CFM with service value 6.00 BEE ,five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engineer-in-Charge. |
| 58 | Taking down unserviceable Ceiling/Exhaust/wall mounted Fan (any size), sealing cable end, dismantling blades and removing fan and blades to store, complete all as specified and directed by Engineer-in-Charge. |
| 59 | M&L for Re-winding the existing unserviceable Ceiling fans of any make but of size 1200 / 1400 mm sweep, opening the ceiling fan, removing the burnt copper winding after testing, cutting the rotor coil, cleaning the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, replacing the wornout bearings, over-hauling, lubricating with fresh grease, re-assembling and testing for satisfatory operation complete all as specified and directed by Engineer-in-Charge. |
| 60 | M&L for Re-winding the existing unserviceable Exhaust fans of any make but of size 300 mm sweep, opening of Exhaust fans, removing the burnt copper winding after testing, cutting the rotor coil, cleaning the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, over-hauling, lubricating with fresh grease re-assembling and testing for satisfatory operation complete all as specified and directed by Engineer-in-Charge. |
| 61 | All as per item No 14 above but Exhaust fans of size 380/450 mm sweep . |
| 62 | M&L for Rewinding of Table/Bracket fan/wall mounted of any size including opening of fan removing the burnt copper winding after testing and cutting the rotor coil complete, cleaning the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, over-hauling, lubricating with fresh grease including re-assembling and testing for satisfatory operation complete all as specified and directed by Engineer-in-Charge. |
| 63 | M&L for painting of rewinding ceiling fan of 1200/1400mm sweep including preparing the surface of body/blades of ceiling fan of any sweep and make and painting with two coats of synthetic enamel white paint and writing the MES No. complete all as specified and directed by Engineer in charge. |
| 64 | M&L for painting of rewinding exhaust fan of any sweep including preparing the surface of body/blades/frame of of exhaust fan of any sweep and make and painting with two coats of synthetic enamel Grey paint and writing the MES No. with black paint complete all as specified and directed. |
| 65 | S&F in replacement of PCB for BLDC ceiling fan with microcontroller, capacitors & inductors, PCB will be rectifier circuit transforms standard 220V-240V AC input into the required DC voltage to run the brushless motor including taking down old existing unserviceable PCB complete all as specified and directed. |
| 66 | S&F in replacement of 2.5 MFD fan capacitor of apporved make for ceiling fan, Including taking down old existing unserviceable complete all as specified and directed. |
| 67 | S&F Sweep 300mm Exhaust Fan made of steel body AC single phase, voltage 230V, 50Hz, copper winding, including blades, frame & louvers, complete all as specified and directed by Engineer in charge. |
| 68 | S&F Sweep 380mm Exhaust Fan made of steel body AC single phase, voltage 230V, 50Hz, copper winding, including blades, frame & louvers, complete all as specified and directed by Engineer in charge. |
| 69 | Labour only for taking down & opening carefully storage type water heater any make and capacity form clamps/bolts including disconnection water and electric connection or refixing the same and connecting up complete all as specified and directed by Engineer in charge. |
| 70 | S&F in replacement geyser flange assembly (any make/type) copper alloy chromium plates suitable for 25/50 Ltrs capacity including rubber gasket, clamps and nuts/bolts etc complete complete all as specified and directed. |
| 71 | S&F in replacement and connecting heating element (triangular or circular base type) 1.5/2 KW, 230 Volts ISI Marked, suitable for 25/50 Ltrs capacity geysers in replacement of old unserviceable heating element complete all as specified and directed. |
| 72 | S&F in replacement of capillary thermostat and thermal cut out combo ISI standerd of existing type/make complete all as specified and directed. |
| 73 | S&F in replacement of safety/pressure release/non return valve brass (ISI marked) best quality size 15mm suitable for 25/50 ltr capacity geysers including taking down old unservisible complete all as specified and directed. |
| 74 | S&F in repair Bib taps chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of size 15mm bore including taking down old existing unserviceable complete all as specified and directed. |
| 75 | S&F in repair Stop valve chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of size 15mm bore including taking down old existing unserviceable complete all as specified and directed. |
| 76 | S&F in replacement of flexible connection pipe heavy duty Hot and cold stainless steel pipe, anti explosion design, pack of two of superior quality as per existing pattern with washer fitted at both end suitable to 15mm GI pipe line including taking down old unservisible complete all as specified and directed. |
| 77 | S&F in replacement 200mm sweep Exhaust Fan (White) plastic body, complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, copper winding, including making electrical connection & taking down old unserviceable exhaust fan complete all as specified and directed by Engineer in charge. |
| 78 | S&F in replacement 250mm sweep Exhaust Fan (White) plastic body, complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, copper winding, including making electrical connection & taking down old unserviceable exhaust fan complete all as specified and directed by Engineer in charge. |
| 79 | S&F in repair PVC casing capping size 20mm including all accessories, fixing arrangement, screws, etc complete all as specified and directed. Make: Modi |
| 80 | S&F in repair PVC casing capping size 25mm including all accessories, fixing arrangement, screws, etc complete all as specified and directed. Make: Modi |
| 81 | S&F in repair PVC casing capping size 32mm including all accessories fixing, arrangement, screws, etc complete all as specified and directed. Make: Modi |
| 82 | S&F in repair 25mm Flex corrugated flexible hose pipes made with strong pipes of virgin plastic, highly flexible, anti-distortion, good bending performance, well strech, complete all as specified and directed. Make: Modi |
| 83 | S&F in repair for Rigid non-metallic PVC conduit of 20 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks,cable tie etc complete all as specified and directed by Engineer in charge. |
| 84 | S&F in repair for Rigid non-metallic PVC conduit of 25 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks,cable tie etc complete all as specified and directed by Engineer in charge. |
| 85 | S&F in repairs HFFR PVC insulated multistranded copper conductor cable single core of size 1.5 Sqmm, 1100 volt, confirming to IS 17048, complete all as specified and directed. Make - Havells, polycab, & finolex etc as approved by GE. |
| 86 | S&F in repairs HFFR PVC insulated multistranded copper conductor cable single core of size 2.5 Sqmm, 1100 volt, confirming to IS 17048, complete all as specified and directed. Make - Havells, polycab, & finolex etc as approved by GE. |
| 87 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 10.00 sq. mm x 2 core cable complete all as specified and as directed. |
| 88 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 16.00 sq. mm x 2 core cable complete all as specified and as directed. |
| 89 | S&F in repair for GI Bracket made out from GI pipe 25/32mm dia bend to shape as required, and flat iron clamps of sutable size bolts, nuts, washers etc for fixing of security light fitting, complete all as specified and as directed. |
| 90 | S&F in repair Louvers fixed type any size made out of 1.6mm GI sheet with horizontal ventilation, machine pressed cutting for horizontal ventilation with flat iron base of including taking down old existing unserviceable louvers complete all as specified and directed. |
| 91 | S&F in repair copper earth strip 20 x 3 mm with saddles and fixing screws on porecelain insulator/ spacer fixed at every 1 mtr length for extension of earthing strip on roof/wall and joining the same with earth test point complete all as specified and directed by Engr-in-Charge. |
| 92 | M&L in repair earth continunity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of 4.00 mm dia GI or steel wire complete all as specified and directed by Engr-in-Charge. |
| 93 | M&L in repair for air termination, single pointed aluminium rod, 12mm dia and 300mm long including necessary fixing arrangement using clamp, nuts and bolts complete all as specified and directed by Engr-in-Charge. |
| 94 | S&F in repair test point terminal block inside the box which made out of gun metal or phosphorous bronze of size 75 x 75 x 25mm, drilled and screwed including 3 Nos 8mm dia 25 mm long hex Head screw including thermoplastic weather proof terminal empty box for fixing the terminal block complete all as specified and directed. |
| 95 | M&L for dismantling the existing broken earth pits and necessary PCC work for repair earth pit complete all as specified and directed. |
| 96 | M&L in repair for earthing complete with Galvanised steel earth plate electrode of size 600mmx600mmx6mm, buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth plate not less than 1.5 Mtrs deep below normal ground level, connected to GI 4.0 Sqmm wire by bolts, nuts, check nuts and washers of GI or steel and connected to earthing test point/distribution board/LT Panel/equipments or any other indicated situation all as shown in electrical plate No. 3 of SSR Part I (2009) and testing on completion including necessary excavation and earth work in any type of soil, returning filling, removing of soil. GI medium grade pipe 32mm dia 1.5 mtr long for watering pipe. Earth pit chamber made of PCC 1:3:6 type B1 using block masonry including chamber cover made of 1:2:4 type B1 using 20mm graded aggregate and reinforced with 8 mm dia TMT bars at 150mm c/c on both ways precast chamber cover with lifting handle, including charcoal and common salt in alternate layer of 15cm thick covering all faces of earth electrode plate, complete all as specified and directed. Note :- (i) The rates quoted for the complete earthing shall deemed to include the cost of GI 4.0 Sqmm wire and GI medium grade protection pipe upto 7.5 Mtrs.(ii) GI 4.0 Sqmm wire and GI medium grade protection pipe beyond 7.5 Mtrs length shall be measured and paid separately. |
| 97 | M&L in repair for earthing complete with copper earth plate electrode of size 600mmx600mmx3.15mm, buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth plate not less than 1.5 Mtrs deep below normal ground level, connected to copper earth strip 20 x 3 mm by bolts, nuts, check nuts and washers of copper and connected to earthing test point/distribution board/LT Panel/equipments or any other indicated situation all as shown in electrical plate No. 3 of SSR Part I (2009) and testing on completion including necessary excavation and earth work in any type of soil, returning filling, removing of soil. GI medium grade pipe 32mm dia 1.5 mtr long for watering pipe. Earth pit chamber made of PCC 1:3:6 type B1 using block masonry including chamber cover made of 1:2:4 type B1 using 20mm graded aggregate and reinforced with 8 mm dia TMT bars at 150mm c/c on both ways precast chamber cover with lifting handle, including charcoal and common salt in alternate layer of 15cm thick covering all faces of earth electrode plate, complete all as specified and directed. Note :- (i) The rates quoted for the complete earthing shall deemed to include the cost of copper 20x3 mm and GI medium grade protection pipe upto 7.5 Mtrs.(ii) Copper earth strip and GI medium grade protection pipe beyond 7.5 Mtrs length shall be measured and paid separately. Please Enable Macros to View BoQ information |