| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8130/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: REPAIR / REPLACEMENT OF STREET LIGHTS, CABLES AND CONNECTED ACCESSORIES OF 17 DOGRA & ARTY CENTRE UNDER GE GOLCONDA Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | S&F Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.00 metre long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/ exposed surfaces, including taking down existing pole of any description, complete all as specified and directed. Note: (i) Rate quoted by the contractor shall deemed to includes excavation and earth work, 150mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) below pole and filled in trench alround the pole including coping up to 20cm above ground using PCC (1:2:4) type B1 with required formwork complete.(iii) Rate quoted by the contractor shall also deemed to include for taking down carefully the existing unserviceable pole, serviceable street light fitting and ACSR conductor including connecting accessories and refixing the same after replacing the new pole with all necessary accessories complete all as specified and directed. |
| 3 | S&F Driver circuit board 45W with necessary wiring including taking down existing driver circuit board from street light pole of any make, complete all as specified and directed. |
| 4 | S&F Driver circuit board 60W Model with necessary wiring including taking down existing driver circuit board from street light pole of any make, complete all as specified and directed. |
| 5 | S&F Driver circuit board 90W with necessary wiring including taking down existing driver circuit board from street light pole of any make, complete all as specified and directed. |
| 6 | S&F Driver circuit board 120W with necessary wiring including taking down existing driver circuit board from street light pole of any make, complete all as specified and directed. |
| 7 | S&F Surge protector device for street light fitting of any make/type/capacity with necessary wiring including taking down existing surge protector device from street light pole, complete all as specified and directed. |
| 8 | Taking down existing LED street light fitting Item poles and Replace luminaire of any type, 230 volts, AC energy saving and environmental friendly long life versatile, pressure di-cast aluminium including electrical connections and taking down of existing unserviceable fitting complete all as specified and directed. |
| 9 | S&F in repair 60W energy saving and environmental friendly long life LED building security street light made up of pressure die cast aluminium housing with high power LED, lens & toughened glass, having TOP opening separate driver compartment potted driver and with efficacy of 130lm/W, ,impact resistance IK07,surge protection 10 kv inbuilt &IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed. MAKE- CAT noENDURAOMNPLUSSL60W LED757SASYTOPC of havells or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 10 | S&F in repair 90W energy saving and environmental friendly long life LED building security street light made up of pressure die cast aluminium housing with high power LED, lens & toughened glass, having TOP opening separate driver compartment potted driver and with efficacy of 130lm/W, ,impact resistance IK07,surge protection 10 kv inbuilt &IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed. MAKE- CAT noENDURAOMNPLUSSL90W LED757SASYTOPC of havells or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 11 | S&F in repair 120W energy saving and environmental friendly long life LED building security street light made up of pressure die cast aluminium housing with high power LED, lens & toughened glass, having TOP opening separate driver compartment potted driver and with efficacy of 130lm/W, ,impact resistance IK07,surge protection 10 kv inbuilt &IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed. MAKE- CAT noENDURAOMNPLUSSL120W LED757SASYTOPC of havells or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 12 | S&F in repair 45W energy saving and environmental friendly long life LED building security street light made up of pressure die cast aluminium housing with high power LED, lens & toughened glass, having TOP opening separate driver compartment potted driver and with efficacy of 130lm/W, ,impact resistance IK07,surge protection 10 kv inbuilt &IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed. MAKE- CAT noENDURASUNDOWN45W LED765PASYBOTG of havells or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 13 | Supply and lay in trenches/fixed to walls/poles etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of size 2 Core 10 Sqmm including taking out of existing cable complete all as specified and directed.. Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately. |
| 14 | All as per item No:12 above but 2 Core 16 Sqmm |
| 15 | All as per item No:12 above but 4 Core 16 Sqmm |
| 16 | All as per item No:12 above but 4 Core 25 Sqmm |
| 17 | S&F Hot press moulded SMC Junction box of size 270 mm x 200 mm x 135 mm with right openable hinged door with two number aluminium bus bars mounted on porcelain insulator including clamps of MS flat iron 25 x 3 mm with bolts and nuts and including one MCB SP upto 6A, 10 KA for ON/OFF street light, fixed on pole including taking down old junction box, complete all as specified and directed. Make : Sintex/HPL/MDS |
| 18 | S & F of nature switch pole mounted enclosure consisting of NATURE SWITCH-02, power contactor for load switching, MCB, and terminal blocks. The enclosure complete with mounting brackets, cable glands, openable door with lock and key. The enclosure is made of UV stabilized, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor. Selectable options are available for duration based switching OFF suitable for single phase operation of 08 KW load, 230 Volts, 50 Hz, AC , with all connected accessories, including taking down existing timer switch of any description, complete all as specified and directed. |
| 19 | S & F nature switch pole mounted enclosure consisting of NATURE SWITCH-02, power contactor for load switching, MCB, and terminal blocks. The enclosure with mounting brackets, cable glands, openable door with lock and key arrangement. The enclosure is made of UV stabilized, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor. Selectable options are available for duration based switching OFF suitable for 12 KW load, three phase operation, 415 Volts, 50 Hz, AC, with all connected accessories, including taking down existing timer switch, complete all as specified and directed. |
| 20 | S&F on / off switch for timer nature switch -02, 8 KW single phase street light timer control including taking down existing nature switch for the street light timer switch, complete all as specified and directed. |
| 21 | All as per item No. 19 hereinbefore but for three phase timer of 12KW. |
| 22 | S&F contactor 8KW suitable for single phase street light timer control unit of existing make and model as per site requirement, including taking down existing unserviceable contactor of any description complete all as specified and directed. |
| 23 | All as per item No. 21 hereinbefore but for 12KW. |
| 24 | S&F bracket made out of 40 mm dia GI pipe, light grade, 1.5m long, bend to shape including clamps, nuts and bolts etc and required electrical connections including taking out old unserviceable brackets of any description complete all as specified and directed. |
| 25 | S&F bracket made out of 50 mm dia GI pipe, light grade, 1.5m long, bend to shape including clamps, nuts and bolts etc and required electrical connections including taking out old unserviceable brackets of any description complete all as specified and directed. |
| 26 | S&F PVC insulated and FR PVC round sheathed, copper conductor, flexible industrial cable, 1100Volts, 1.5 Sqmm 2 core for connection from junction box to street light fitting complete all as specified and directed. |
| 27 | S&F PVC insulated and FR PVC round sheathed, copper conductor, flexible industrial cable, 1100Volts, 2.5 Sqmm 2 core for connection from junction box to street light fitting complete all as specified and directed. |
| 28 | M&L for cleaning thoroughly the street light poles/LT distribution poles of any height and any description (Maximum 9 Mtr long ) with necessary cleaning agent including complete removal of existing paint by scrapping etc carefully and applying two coat of synthetic aluminium paint over a coat red oxide primer complete all as specified and directed . |
| 29 | Cutting & trimming of tree branches any girth and size touching to overhead lines and clearing the distance 1.5 mtr both sides of overhead line with in a gap of span 35 to 50 mtrs each and removing the same cleaning the site all as specified and directed. |
| 30 | S&F PVC conduit suitable for 20mm on pole(steel pole/ concrete pole) from junction box to street light fitting for PVC wire complete all as specified and directed. |
| 31 | S&F PVC flexible conduit (size 20mm ) on pole from junction box to PVC conduit & PVC conduit to streetlight fitting complete all as specified and directed. |
| 32 | Supply, Fixing and stringing ACSR Conductor steel reinforced of type as directed including stretching, binding using ACSR conductor on insulator on overhead line including taking down of existing conductor complete all as specified and directed. |
| 33 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of poles / cable in trenches and getting out in hard/dense soil complete all as specified and as directed . |
| 34 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as directed by Engineer-in-Charge. |
| 35 | Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above from the starting point complete all as specified and directed. |
| 36 | Supply and spread approved dry river sand for cushioning of cable laid in trenches including watering and consolidation, complete all as specified and directed. Note:- Punned thickness of sand cushioning shall only measured for payment purpose. |
| 37 | M&L for brick, sub class 'B', old size, laid in trenches as cable protection covers, complete all as specified and directed. |
| 38 | supply and fix 40 W solar street light is made with high efficiency mono crystalline solar PV module ,lithium ferro phosphate battery with in built BMS technology high efficiency LED MPPT solar charge and AL extruded body &is special performed to automatically control the dimming and brightness of light complete all as specified and directed. |
| 39 | Supply & fix 6 Mtr Octoganal GI Solar Street light pole Suitable for 40W/60W solar light , complete all as specified and directed. Note: (i) Rate quoted by the contractor shall deemed to includes excavation and earth work, 150mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) below pole and filled in trench alround the pole including coping up to 20cm above ground using PCC (1:2:4) type B1 with required formwork complete |
| 40 | Supply & fix bamboo 8W LED BOLLARD light long life aesthetically designed IP-54 die cast aluminium landscape all as directed by engg- harge make - cat no BAMBOOBLS 8W LED830SS of havells/bajaj/wipro |
| 41 | Supply, install, test and commission CPRI APPROVED factory fabricated, outdoor type, LT FEEDER PILLAR BOX made out of 3.15mm thick CRCA sheet of size 1M x 0.75M x 0.35M with projected globe roof for rainwater protection dust and vermin proof, double door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc. and embedded with 50x50x6mm MS angle iron frame, 600mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:3:6 (20mm graded stone aggregate) complete all as specified and comprising of the following :-(a) Aluminium busbar 200 amps - 04 Nos, supported on suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b) MCCB 100 amps, 415 volt, 16 KA breaking capacity 4 pole electromagnetic release duly connected to busbar as incoming - 01 No. |
| 42 | Supply & Laying 40 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |