| Sl. No. | Item Description |
| 1 | GST % for the tender Please select the rate of GST in cell AY13. Rate selected shall be applicable for the entire BoQ. |
| 2 | AMC for HM Towers and Flood Light Towers at ERPL Haldia (PHBPL) |
| 3 | Repairing of Winch Motor:Rewinding of 1-phase/3-phase electrical motors of various voltage grades/makes/types and of following capacities as per the original specifications & types/gauge of rewinding/winding wire, insulation of various points inside slots/overhang and overall final layers of insulation/tapes as per the original motor specifications, after baking to required temperature and applying insulating varnish (Dr-Beck & Co. make & type), providing glass/other types of sleaves on connection wires from inside motor winding to connection plate. The winding, varnishing, tapes and other materials required for completion of this complete job is in the scope of contractor excluding transportation to & from Owner’s works to Contractor's rewinding shop. which shall be paid seperately on trip basis.The winding wire will be Devi Dayal make and insulation tapes shall be ISI marked & of reputed manufacturers as per decision of Engineer-in- Charge. This also includes repair/replacement of connection plate completely including insulating sheet, nuts, bolts, washers and other hardwares as per original specifications. This further includes replacement of bearings (DE & NDE) of SKF make & greasing (IOC/HP make Servogem 2 or equivalent). This further includes satisfactory trial of motors at Owner’s premises at No load as well as at Full load. The Contractor will guarantee the rewound motors for satisfactory performance for a period of minimum six months at owner’s premises & if any such rewound motor fails within six months, it is to be rewound again by Contractor free of cost. All complete with labour and materials as per directions of Engineer-in-Charge.Note: Burnt winding wire shall be kept by Contractor. Bearing Shall be supplied by IOCL |
| 4 | Rectification of Lighting DBs:Rectification of circuit fault in FLP/Non FLP Lighting junction boxes etc. including supply of minor type of materials, consumables like PVC putty/M-seal putty, easy clean etc to avoid entering of water/inspect, all complete with labour and materials as per directions of the Engineer-in-Charge. Materials like lugs, glands shall be paid vide separate line item of SOR. |
| 5 | Structural works:Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint \\"EPILUX 155\\" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer’s recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work). |
| 6 | SITC of Junction Box:Supply, erection, installation, testing and commissioning of weather proof junction box of approved make with minimum 18 cable entries (suitable for 5Cx4 sqmm & 3Cx2.5 sqmm) for providing cable termination & including connection and termination of earthing wire and conduits, including supply & installation of cable glands & plugs for sealing all spare entries etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect. |
| 7 | Cable Laying OD above 20mm:Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD above 20 mm and upto 40 mm |
| 8 | Cable Laying OD upto 20mm:Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD upto 20 mm |
| 9 | LT Cable Joint OD above 20mm:Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD above 20 mm and upto 40 mm |
| 10 | LT Cable Joint OD upto 20mm:Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD upto 20 mm |
| 11 | 3Cx2.5 sqmm Cable termination:Providing end termination of power/control cable including cutting, stripping, providing & fixing heavy duty type lugs, cable insulation, providing & glanding single compression heavy duty brass cable gland conforming to IS-12943 (Dowell's or apporved equivalent), wherever specified, providing heavy duty type aluminium lugs for power cables and copper lugs/connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-Charge. 3 x 2.5 sqmm LT cables with copper lugs |
| 12 | 3.5Cx 35 sqmm Cable termination:Providing end termination of power/control cable including cutting, stripping, providing & fixing heavy duty type lugs, cable insulation, providing & glanding single compression heavy duty brass cable gland conforming to IS-12943 (Dowell's or apporved equivalent), wherever specified, providing heavy duty type aluminium lugs for power cables and copper lugs/connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-Charge. 3-1/2 x 35 sqmm |
| 13 | Cable Tray works:Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings with foundation. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, complete in all respect specification and directions of Site Engineer / Engineer-in-Charge. |
| 14 | 100MM Cable conduit work:Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge: 100 mm |
| 15 | Letter Writing:Lettering with black Japan paint of approved brand and manufacture. [Note: Unit \\"EA\\" shall mean \\"PER LETTER PER CM HEIGHT\\"]. |
| 16 | Primer Coat: Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works after surface preparation, removal of old rusted paint with wired brush including all consumables, tools-tackles, labour complete in all respect as per direction of Engineer In Charge. |
| 17 | Epoxy Paint: Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete : On steel work. |
| 18 | Supply of 3.5Cx35 sqmm Power Cable:Supply of Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%: AL,3.5CX35mm²,A2XFY |
| 19 | Supply of 3CX2.5 mm Power Cable:Supply of Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40% CU,3CX2.5 mm²,2XWY |
| 20 | Installation of Lights upto 8 M Height:Installation of OWNER supplied NFLP/FLP lights on High Masts/ Pump shed / Fire Fighting Engine Shed / Equipment Shed / Roof mounted structure / other mounted structure upto height of 8.0 M complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer. |
| 21 | Dismantling of defective lights upto 8 M Height:Dismantling of existing defective lights from High Masts/ Pump shed / Fire Fighting Engine Shed / Equipment Shed / Roof mounted structure / other mounted structure upto height of 8.0 M and shifting of defective lights to work shop / other designated place within boundary complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer. |
| 22 | Installation of lights above 8M Height:Installation of OWNER supplied NFLP/FLP lights on Flood Light Towers (FLTs)/ other mounted structures height above 8.0 M complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer |
| 23 | Dismantling of defective lights above 8 M Height:Dismantling of existing defective lights from Flood Light Towers/ other mounted structures height above 8.0 M and shifting of lights to work shop / other designated place within boundary complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer. |
| 24 | Wire rope testing:Carrying out wire rope testing at any NABL acrediated or Govt. Lab as per latest IS Standard including making & collecting samples from HM, transportation of the same to lab, collection of report & all other required works to execute the testing in toto as per direction of EIC. |
| 25 | Supply of trailing cable:Supply of 5C x 4 sqmm copper conductor EPR insulated & PCP sheathed trailing cable for High Mast |
| 26 | Supply of wire Rope:Supply of SS Wire Rope 7x19 AISI 316 Wire rope for High Mast. Unit of measurement \\"EA\\" indicates individual High Mast Tower . |
| 27 | Supply of winch motor:Supply of Flame proof 1.6 HP winch motor,DDMFO |
| 28 | Supply of winch chain:Supply of winch chain. |
| 29 | Supply of Manual Timer:Supply of Manual Timer as per direction of EIC. |
| 30 | Dismantling & Re-commissioning of HMT:Job includes lowering & Dismantling of light fittings, Dismantling of Pole, rectification, carrying out alignment of pole etc. and re-erection of pole, re-installation of light fittings including repair/replacement of wire rope and trailing cable, inspection and maintenance of head frame. job complete in all respect including overhauling to be executed with man, materials, tools and tackles as per instruction of EIC. Unit of Measurement \\"EA\\" indicates individual High Mast Tower.For dismantling of Pole, Supply of crane shall be paid against separate line items.Other Materials like wire clamps, cable clamps,other material as required etc, tools and tackles, high mast lifting rope and man power are in scope of contractor. Wire rope, clamps and trailing cable shall be paid against separate line items. |
| 31 | Yearly-Maint of HM Tower:Yearly Maintenance of HM Tower as per SCOPE OF WORK including following activities:1. Lowering down of lighting carriage Fittings; 2. Overhauling of gear box including supply and change of recommended Grease or gear oil, cleaning of gear box, rectification of gear box defects including minor welding jobs, Alignment of gear box with motor, tightness of motor base-bolts, rectification and greasing of the coupling chain. 3. Tightness of Nut-Bolt of winch drum, face plate, bracket, chain set alignment, winch alignment, pole alignment (without pole dismantling) & other related jobs.4. Inspection of wire ropes and trailing cable and provision of new clamps in place of damaged ones, replacement of wire ropes if found damaged without dismantling of pole (if possible) as per instruction of IOCL site engineer. New Clamps of stainless steel material only is to be provided. Supply of Wire, rope shall be paid vide separate line item.5. Replacement of damaged flexible trailing cable from pole mast terminal box to light fittings as per instruction of IOCL site engineers. Supply of Cable shall be paid vide separate line item.6. Checking of alignment of the high mast pole, alignment of fittings with respect to pole, checking of inner ring of lighting carriage and replacement of rubber pad if required, Tightness of pole base bolts and alignment of pole with respect to ground as per instruction of Site Engineer.7. Lowering and raising of FLM fittings smoothly in presence of IOCL site engineer.8. All consumable items such as drill bit, hammer bit, nut-bolt, rubber seal packing, grease or gear oil, CRC, Easy clean & other relevant tools-tackles shall be supplied by the contractor. No additional claim shall be entertained for consumable items apart from SOR.9. Maintenance of HMT feeder pillar including replacement of faulty MCB, contactor, wire re-lugging & circuit fault rectification etc. MCB, Contactor shall be supplied by owner. 10. Contractor shall submit signed & stamp copy of IOCL checklist after job completion for each high mast tower.11. All consumables such as Nut-Bolt, gear oil, grease, lugs, Putty, Easy clean, cutton waste etc shall be supplied by Contractor without any extra claim. Separate item shall be paid as per SOR line item only. Unit of Measurement \\"EA\\" indicates individual High Mast Tower |
| 32 | Pre-cyclone HM Lowering works:Supply of PVC ropes, providing service for lowering all High Masts, covering of all LED lights with properly wrapped plastic with PVC ropes, checking tightness of luminaire structure bolts, after cyclone, restoration of site complete in all respect. |
| 33 | Head frame Repair maintenance: Head frame maintenance including replacement of bush of gun metal or bearing with complete alignment if required. (in case of pulley damaged or alignment out) as per direction of EIC. |
| 34 | Winch/Spur Gear Repair maintenance: Supply and fixing of spur gear of HM complete with replacement of bush of gun metal and alignment, fixing with the HM , successful trial run and operation of the gear for lowering and raising of lighting carriage in presence of IOCL engineer. The job should be completed with all man, materials and tools and tackles as per Direction of EIC. |
| 35 | Supply of Head Frame Galvanised:Supply of Head Frame Galvanised for 30M |
| 36 | Supply of Lantern Carriage rest stand:Supply of lanten carriage rest stand |
| 37 | Supply of winch stand:Supply of winch stand. |
| 38 | Supply of winch gear:Supply of winch gear |
| 39 | Supply of Lantern Carriage:Supply of Lantern Carriage suitable for mounting existing Luminiares of High Mast. |
| 40 | Supply of Motor Handle:Supply of Motor Handle to be used for High Mast. |
| 41 | Supply of GI Fastner (M16x40mm): Supply of GI fastner sets of M16x40 mm |
| 42 | Supply of GI Fastner (M16x105 mm): Supply of GI fastner sets of M16x105 mm |
| 43 | Supply of GI Fastner (M19x40 mm): Supply of GI fastner sets of M19x40 mm |
| 44 | Supply of GI Fastner (M12x35 mm): Supply of GI fastner sets of M12x35 mm |
| 45 | Supply of GI Fastner (M10x25 mm): Supply of GI fastner sets of M10x25 mm |
| 46 | Supply of Trailing cable Clamp with single Hole:Suppy of HM Trailing Cable clamp with Single hole. |
| 47 | Supply of Trailing cable Clamp with double Hole:Suppy of HM Trailing Cable clamp with double hole. |
| 48 | Suppy of Wire rope clamp:Suppy of HM Wire rope clamp. |
| 49 | Supply of Male-Female Plug:Supply of Male-Female Plug for Trailing cable of High Mast. |
| 50 | Supply & fixing of thimble, lugs:Supply & fixing of thimble, lugs. |
| 51 | Supply of 90W NFLP LED FLOOD LIGHT:Supply of 90 W NFLP LED Flood Light of reputed brand make as per specifications, complete with driver, mounting accessories and warranty. |
| 52 | Supply of 150W FLP LED FLOOD LIGHT:Supply of 150 W FLP LED Flood Light of reputed brand make as per specifications, complete with driver, mounting accessories and warranty. |
| 53 | Supply 350W NON-FLP LED FLOOD LIGHT:Supply of 300 W FLP LED Flood Light of reputed brand make as per specifications, complete with driver, mounting accessories and warranty. |
| 54 | SIC of 62Meters SS WireRope 7/19 con:Supply and fixing of 62Meters SS WireRope 7/19 for HM. Unit of measurement \\"EA\\" indicates individual High Mast Tower . |
| 55 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 90W)/LED chip (rating upto 90W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 56 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 120W)/LED chip (rating upto 120W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 57 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 150W)/LED chip (rating upto 150W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 58 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 300W)/LED chip (rating upto 300W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 59 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 500W)/LED chip (rating upto 500W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 60 | Supply of Photo Senser :Supply of Photo Senser as per direction of EIC. |
| 61 | Supply of street Light Junction Box(J.B):Supply of street Light J.B (16mm SWH Sheet) G.I Size - 2.50 mm x 250mm x10mm including supply of 2 nosclamp (19mm x3) G.I strp also direction of EIC. |
| 62 | Installation of trailing cable:Installation of 5C x 4 sqmm copper conductor EPR insulated & PCP sheathed trailing cable for High Mast. Unit of measurement \\"EA\\" indicates individual High Mast Tower. |
| 63 | AMC for HM Towers and Flood Light Towers at ERPL Haldia (PSHPL) |
| 64 | Repairing of Winch Motor:Rewinding of 1-phase/3-phase electrical motors of various voltage grades/makes/types and of following capacities as per the original specifications & types/gauge of rewinding/winding wire, insulation of various points inside slots/overhang and overall final layers of insulation/tapes as per the original motor specifications, after baking to required temperature and applying insulating varnish (Dr-Beck & Co. make & type), providing glass/other types of sleaves on connection wires from inside motor winding to connection plate. The winding, varnishing, tapes and other materials required for completion of this complete job is in the scope of contractor excluding transportation to & from Owner’s works to Contractor's rewinding shop. which shall be paid seperately on trip basis.The winding wire will be Devi Dayal make and insulation tapes shall be ISI marked & of reputed manufacturers as per decision of Engineer-in- Charge. This also includes repair/replacement of connection plate completely including insulating sheet, nuts, bolts, washers and other hardwares as per original specifications. This further includes replacement of bearings (DE & NDE) of SKF make & greasing (IOC/HP make Servogem 2 or equivalent). This further includes satisfactory trial of motors at Owner’s premises at No load as well as at Full load. The Contractor will guarantee the rewound motors for satisfactory performance for a period of minimum six months at owner’s premises & if any such rewound motor fails within six months, it is to be rewound again by Contractor free of cost. All complete with labour and materials as per directions of Engineer-in-Charge.Note: Burnt winding wire shall be kept by Contractor. Bearing Shall be supplied by IOCL |
| 65 | Rectification of Lighting DBs:Rectification of circuit fault in FLP/Non FLP Lighting junction boxes etc. including supply of minor type of materials, consumables like PVC putty/M-seal putty, easy clean etc to avoid entering of water/inspect, all complete with labour and materials as per directions of the Engineer-in-Charge. Materials like lugs, glands shall be paid vide separate line item of SOR. |
| 66 | Structural works:Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint \\"EPILUX 155\\" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer’s recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work). |
| 67 | SITC of Junction Box:Supply, erection, installation, testing and commissioning of weather proof junction box of approved make with minimum 18 cable entries (suitable for 5Cx4 sqmm & 3Cx2.5 sqmm) for providing cable termination & including connection and termination of earthing wire and conduits, including supply & installation of cable glands & plugs for sealing all spare entries etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect. |
| 68 | Cable Laying OD above 20mm:Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD above 20 mm and upto 40 mm |
| 69 | Cable Laying OD upto 20mm:Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD upto 20 mm |
| 70 | LT Cable Joint OD above 20mm:Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD above 20 mm and upto 40 mm |
| 71 | LT Cable Joint OD upto 20mm:Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD upto 20 mm |
| 72 | 3Cx2.5 sqmm Cable termination:Providing end termination of power/control cable including cutting, stripping, providing & fixing heavy duty type lugs, cable insulation, providing & glanding single compression heavy duty brass cable gland conforming to IS-12943 (Dowell's or apporved equivalent), wherever specified, providing heavy duty type aluminium lugs for power cables and copper lugs/connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-Charge. 3 x 2.5 sqmm LT cables with copper lugs |
| 73 | 3.5Cx 35 sqmm Cable termination:Providing end termination of power/control cable including cutting, stripping, providing & fixing heavy duty type lugs, cable insulation, providing & glanding single compression heavy duty brass cable gland conforming to IS-12943 (Dowell's or apporved equivalent), wherever specified, providing heavy duty type aluminium lugs for power cables and copper lugs/connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-Charge. 3-1/2 x 35 sqmm |
| 74 | Cable Tray works:Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings with foundation. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, complete in all respect specification and directions of Site Engineer / Engineer-in-Charge. |
| 75 | 100MM Cable conduit work:Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge: 100 mm |
| 76 | Letter Writing:Lettering with black Japan paint of approved brand and manufacture. [Note: Unit \\"EA\\" shall mean \\"PER LETTER PER CM HEIGHT\\"]. |
| 77 | Primer Coat: Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works after surface preparation, removal of old rusted paint with wired brush including all consumables, tools-tackles, labour complete in all respect as per direction of Engineer In Charge. |
| 78 | Epoxy Paint: Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete : On steel work. |
| 79 | Supply of 3.5Cx35 sqmm Power Cable:Supply of Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%: AL,3.5CX35mm²,A2XFY |
| 80 | Supply of 3CX2.5 mm Power Cable:Supply of Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40% CU,3CX2.5 mm²,2XWY |
| 81 | Installation of Lights upto 8 M Height:Installation of OWNER supplied NFLP/FLP lights on High Masts/ Pump shed / Fire Fighting Engine Shed / Equipment Shed / Roof mounted structure / other mounted structure upto height of 8.0 M complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer. |
| 82 | Dismantling of defective lights upto 8 M Height:Dismantling of existing defective lights from High Masts/ Pump shed / Fire Fighting Engine Shed / Equipment Shed / Roof mounted structure / other mounted structure upto height of 8.0 M and shifting of defective lights to work shop / other designated place within boundary complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer. |
| 83 | Installation of lights above 8M Height:Installation of OWNER supplied NFLP/FLP lights on Flood Light Towers (FLTs)/ other mounted structures height above 8.0 M complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer |
| 84 | Dismantling of defective lights above 8 M Height:Dismantling of existing defective lights from Flood Light Towers/ other mounted structures height above 8.0 M and shifting of lights to work shop / other designated place within boundary complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer. |
| 85 | Wire rope testing:Carrying out wire rope testing at any NABL acrediated or Govt. Lab as per latest IS Standard including making & collecting samples from HM, transportation of the same to lab, collection of report & all other required works to execute the testing in toto as per direction of EIC. |
| 86 | Supply of trailing cable:Supply of 5C x 4 sqmm copper conductor EPR insulated & PCP sheathed trailing cable for High Mast |
| 87 | Supply of wire Rope:Supply of SS Wire Rope 7x19 AISI 316 Wire rope for High Mast. Unit of measurement \\"EA\\" indicates individual High Mast Tower . |
| 88 | Supply of winch motor:Supply of Flame proof 1.6 HP winch motor,DDMFO |
| 89 | Supply of winch chain:Supply of winch chain. |
| 90 | Supply of Manual Timer:Supply of Manual Timer as per direction of EIC. |
| 91 | Dismantling & Re-commissioning of HMT:Job includes lowering & Dismantling of light fittings, Dismantling of Pole, rectification, carrying out alignment of pole etc. and re-erection of pole, re-installation of light fittings including repair/replacement of wire rope and trailing cable, inspection and maintenance of head frame. job complete in all respect including overhauling to be executed with man, materials, tools and tackles as per instruction of EIC. Unit of Measurement \\"EA\\" indicates individual High Mast Tower.For dismantling of Pole, Supply of crane shall be paid against separate line items.Other Materials like wire clamps, cable clamps,other material as required etc, tools and tackles, high mast lifting rope and man power are in scope of contractor. Wire rope, clamps and trailing cable shall be paid against separate line items. |
| 92 | Yearly-Maint of HM Tower:Yearly Maintenance of HM Tower as per SCOPE OF WORK including following activities:1. Lowering down of lighting carriage Fittings; 2. Overhauling of gear box including supply and change of recommended Grease or gear oil, cleaning of gear box, rectification of gear box defects including minor welding jobs, Alignment of gear box with motor, tightness of motor base-bolts, rectification and greasing of the coupling chain. 3. Tightness of Nut-Bolt of winch drum, face plate, bracket, chain set alignment, winch alignment, pole alignment (without pole dismantling) & other related jobs.4. Inspection of wire ropes and trailing cable and provision of new clamps in place of damaged ones, replacement of wire ropes if found damaged without dismantling of pole (if possible) as per instruction of IOCL site engineer. New Clamps of stainless steel material only is to be provided. Supply of Wire, rope shall be paid vide separate line item.5. Replacement of damaged flexible trailing cable from pole mast terminal box to light fittings as per instruction of IOCL site engineers. Supply of Cable shall be paid vide separate line item.6. Checking of alignment of the high mast pole, alignment of fittings with respect to pole, checking of inner ring of lighting carriage and replacement of rubber pad if required, Tightness of pole base bolts and alignment of pole with respect to ground as per instruction of Site Engineer.7. Lowering and raising of FLM fittings smoothly in presence of IOCL site engineer.8. All consumable items such as drill bit, hammer bit, nut-bolt, rubber seal packing, grease or gear oil, CRC, Easy clean & other relevant tools-tackles shall be supplied by the contractor. No additional claim shall be entertained for consumable items apart from SOR.9. Maintenance of HMT feeder pillar including replacement of faulty MCB, contactor, wire re-lugging & circuit fault rectification etc. MCB, Contactor shall be supplied by owner. 10. Contractor shall submit signed & stamp copy of IOCL checklist after job completion for each high mast tower.11. All consumables such as Nut-Bolt, gear oil, grease, lugs, Putty, Easy clean, cutton waste etc shall be supplied by Contractor without any extra claim. Separate item shall be paid as per SOR line item only. Unit of Measurement \\"EA\\" indicates individual High Mast Tower |
| 93 | Pre-cyclone HM Lowering works:Supply of PVC ropes, providing service for lowering all High Masts, covering of all LED lights with properly wrapped plastic with PVC ropes, checking tightness of luminaire structure bolts, after cyclone, restoration of site complete in all respect. |
| 94 | Head frame Repair maintenance: Head frame maintenance including replacement of bush of gun metal or bearing with complete alignment if required. (in case of pulley damaged or alignment out) as per direction of EIC. |
| 95 | Winch/Spur Gear Repair maintenance: Supply and fixing of spur gear of HM complete with replacement of bush of gun metal and alignment, fixing with the HM , successful trial run and operation of the gear for lowering and raising of lighting carriage in presence of IOCL engineer. The job should be completed with all man, materials and tools and tackles as per Direction of EIC. |
| 96 | Supply of Head Frame Galvanised:Supply of Head Frame Galvanised for 30M |
| 97 | Supply of Lantern Carriage rest stand:Supply of lanten carriage rest stand |
| 98 | Supply of winch stand:Supply of winch stand. |
| 99 | Supply of winch gear:Supply of winch gear |
| 100 | Supply of Lantern Carriage:Supply of Lantern Carriage suitable for mounting existing Luminiares of High Mast. |
| 101 | Supply of Motor Handle:Supply of Motor Handle to be used for High Mast. |
| 102 | Supply of GI Fastner (M16x40mm): Supply of GI fastner sets of M16x40 mm |
| 103 | Supply of GI Fastner (M16x105 mm): Supply of GI fastner sets of M16x105 mm |
| 104 | Supply of GI Fastner (M19x40 mm): Supply of GI fastner sets of M19x40 mm |
| 105 | Supply of GI Fastner (M12x35 mm): Supply of GI fastner sets of M12x35 mm |
| 106 | Supply of GI Fastner (M10x25 mm): Supply of GI fastner sets of M10x25 mm |
| 107 | Supply of Trailing cable Clamp with single Hole:Suppy of HM Trailing Cable clamp with Single hole. |
| 108 | Supply of Trailing cable Clamp with double Hole:Suppy of HM Trailing Cable clamp with double hole. |
| 109 | Suppy of Wire rope clamp:Suppy of HM Wire rope clamp. |
| 110 | Supply of Male-Female Plug:Supply of Male-Female Plug for Trailing cable of High Mast. |
| 111 | Supply & fixing of thimble, lugs:Supply & fixing of thimble, lugs. |
| 112 | Supply of 90W NFLP LED FLOOD LIGHT:Supply of 90 W NFLP LED Flood Light of reputed brand make as per specifications, complete with driver, mounting accessories and warranty. |
| 113 | Supply of 150W FLP LED FLOOD LIGHT:Supply of 150 W FLP LED Flood Light of reputed brand make as per specifications, complete with driver, mounting accessories and warranty. |
| 114 | Supply 350W NON-FLP LED FLOOD LIGHT:Supply of 300 W FLP LED Flood Light of reputed brand make as per specifications, complete with driver, mounting accessories and warranty. |
| 115 | SIC of 62Meters SS WireRope 7/19 con:Supply and fixing of 62Meters SS WireRope 7/19 for HM. Unit of measurement \\"EA\\" indicates individual High Mast Tower . |
| 116 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 90W)/LED chip (rating upto 90W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 117 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 120W)/LED chip (rating upto 120W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 118 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 150W)/LED chip (rating upto 150W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 119 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 300W)/LED chip (rating upto 300W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 120 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 500W)/LED chip (rating upto 500W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 121 | Supply of Photo Senser :Supply of Photo Senser as per direction of EIC. |
| 122 | Supply of street Light Junction Box(J.B):Supply of street Light J.B (16mm SWH Sheet) G.I Size - 2.50 mm x 250mm x10mm including supply of 2 nosclamp (19mm x3) G.I strp also direction of EIC. |
| 123 | Installation of trailing cable:Installation of 5C x 4 sqmm copper conductor EPR insulated & PCP sheathed trailing cable for High Mast. Unit of measurement \\"EA\\" indicates individual High Mast Tower. |
| 124 | AMC for HM Towers and Flood Light Towers at ERPL Haldia (PHBMPL) |
| 125 | Repairing of Winch Motor:Rewinding of 1-phase/3-phase electrical motors of various voltage grades/makes/types and of following capacities as per the original specifications & types/gauge of rewinding/winding wire, insulation of various points inside slots/overhang and overall final layers of insulation/tapes as per the original motor specifications, after baking to required temperature and applying insulating varnish (Dr-Beck & Co. make & type), providing glass/other types of sleaves on connection wires from inside motor winding to connection plate. The winding, varnishing, tapes and other materials required for completion of this complete job is in the scope of contractor excluding transportation to & from Owner’s works to Contractor's rewinding shop. which shall be paid seperately on trip basis.The winding wire will be Devi Dayal make and insulation tapes shall be ISI marked & of reputed manufacturers as per decision of Engineer-in- Charge. This also includes repair/replacement of connection plate completely including insulating sheet, nuts, bolts, washers and other hardwares as per original specifications. This further includes replacement of bearings (DE & NDE) of SKF make & greasing (IOC/HP make Servogem 2 or equivalent). This further includes satisfactory trial of motors at Owner’s premises at No load as well as at Full load. The Contractor will guarantee the rewound motors for satisfactory performance for a period of minimum six months at owner’s premises & if any such rewound motor fails within six months, it is to be rewound again by Contractor free of cost. All complete with labour and materials as per directions of Engineer-in-Charge.Note: Burnt winding wire shall be kept by Contractor. Bearing Shall be supplied by IOCL |
| 126 | Rectification of Lighting DBs:Rectification of circuit fault in FLP/Non FLP Lighting junction boxes etc. including supply of minor type of materials, consumables like PVC putty/M-seal putty, easy clean etc to avoid entering of water/inspect, all complete with labour and materials as per directions of the Engineer-in-Charge. Materials like lugs, glands shall be paid vide separate line item of SOR. |
| 127 | Structural works:Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint \\"EPILUX 155\\" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer’s recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work). |
| 128 | SITC of Junction Box:Supply, erection, installation, testing and commissioning of weather proof junction box of approved make with minimum 18 cable entries (suitable for 5Cx4 sqmm & 3Cx2.5 sqmm) for providing cable termination & including connection and termination of earthing wire and conduits, including supply & installation of cable glands & plugs for sealing all spare entries etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect. |
| 129 | Cable Laying OD above 20mm:Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD above 20 mm and upto 40 mm |
| 130 | Cable Laying OD upto 20mm:Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD upto 20 mm |
| 131 | LT Cable Joint OD above 20mm:Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD above 20 mm and upto 40 mm |
| 132 | LT Cable Joint OD upto 20mm:Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD upto 20 mm |
| 133 | 3Cx2.5 sqmm Cable termination:Providing end termination of power/control cable including cutting, stripping, providing & fixing heavy duty type lugs, cable insulation, providing & glanding single compression heavy duty brass cable gland conforming to IS-12943 (Dowell's or apporved equivalent), wherever specified, providing heavy duty type aluminium lugs for power cables and copper lugs/connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-Charge. 3 x 2.5 sqmm LT cables with copper lugs |
| 134 | 3.5Cx 35 sqmm Cable termination:Providing end termination of power/control cable including cutting, stripping, providing & fixing heavy duty type lugs, cable insulation, providing & glanding single compression heavy duty brass cable gland conforming to IS-12943 (Dowell's or apporved equivalent), wherever specified, providing heavy duty type aluminium lugs for power cables and copper lugs/connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-Charge. 3-1/2 x 35 sqmm |
| 135 | Cable Tray works:Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings with foundation. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, complete in all respect specification and directions of Site Engineer / Engineer-in-Charge. |
| 136 | 100MM Cable conduit work:Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge: 100 mm |
| 137 | Letter Writing:Lettering with black Japan paint of approved brand and manufacture. [Note: Unit \\"EA\\" shall mean \\"PER LETTER PER CM HEIGHT\\"]. |
| 138 | Primer Coat: Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works after surface preparation, removal of old rusted paint with wired brush including all consumables, tools-tackles, labour complete in all respect as per direction of Engineer In Charge. |
| 139 | Epoxy Paint: Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete : On steel work. |
| 140 | Supply of 3.5Cx35 sqmm Power Cable:Supply of Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%: AL,3.5CX35mm²,A2XFY |
| 141 | Supply of 3CX2.5 mm Power Cable:Supply of Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40% CU,3CX2.5 mm²,2XWY |
| 142 | Installation of Lights upto 8 M Height:Installation of OWNER supplied NFLP/FLP lights on High Masts/ Pump shed / Fire Fighting Engine Shed / Equipment Shed / Roof mounted structure / other mounted structure upto height of 8.0 M complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer. |
| 143 | Dismantling of defective lights upto 8 M Height:Dismantling of existing defective lights from High Masts/ Pump shed / Fire Fighting Engine Shed / Equipment Shed / Roof mounted structure / other mounted structure upto height of 8.0 M and shifting of defective lights to work shop / other designated place within boundary complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer. |
| 144 | Installation of lights above 8M Height:Installation of OWNER supplied NFLP/FLP lights on Flood Light Towers (FLTs)/ other mounted structures height above 8.0 M complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer |
| 145 | Dismantling of defective lights above 8 M Height:Dismantling of existing defective lights from Flood Light Towers/ other mounted structures height above 8.0 M and shifting of lights to work shop / other designated place within boundary complete in all including consumables, labours, tools-tackles as per direction of Engineer In Charge / Site Engineer. |
| 146 | Wire rope testing:Carrying out wire rope testing at any NABL acrediated or Govt. Lab as per latest IS Standard including making & collecting samples from HM, transportation of the same to lab, collection of report & all other required works to execute the testing in toto as per direction of EIC. |
| 147 | Supply of trailing cable:Supply of 5C x 4 sqmm copper conductor EPR insulated & PCP sheathed trailing cable for High Mast |
| 148 | Supply of wire Rope:Supply of SS Wire Rope 7x19 AISI 316 Wire rope for High Mast. Unit of measurement \\"EA\\" indicates individual High Mast Tower . |
| 149 | Supply of winch motor:Supply of Flame proof 1.6 HP winch motor,DDMFO |
| 150 | Supply of winch chain:Supply of winch chain. |
| 151 | Supply of Manual Timer:Supply of Manual Timer as per direction of EIC. |
| 152 | Dismantling & Re-commissioning of HMT:Job includes lowering & Dismantling of light fittings, Dismantling of Pole, rectification, carrying out alignment of pole etc. and re-erection of pole, re-installation of light fittings including repair/replacement of wire rope and trailing cable, inspection and maintenance of head frame. job complete in all respect including overhauling to be executed with man, materials, tools and tackles as per instruction of EIC. Unit of Measurement \\"EA\\" indicates individual High Mast Tower.For dismantling of Pole, Supply of crane shall be paid against separate line items.Other Materials like wire clamps, cable clamps,other material as required etc, tools and tackles, high mast lifting rope and man power are in scope of contractor. Wire rope, clamps and trailing cable shall be paid against separate line items. |
| 153 | Yearly-Maint of HM Tower:Yearly Maintenance of HM Tower as per SCOPE OF WORK including following activities:1. Lowering down of lighting carriage Fittings; 2. Overhauling of gear box including supply and change of recommended Grease or gear oil, cleaning of gear box, rectification of gear box defects including minor welding jobs, Alignment of gear box with motor, tightness of motor base-bolts, rectification and greasing of the coupling chain. 3. Tightness of Nut-Bolt of winch drum, face plate, bracket, chain set alignment, winch alignment, pole alignment (without pole dismantling) & other related jobs.4. Inspection of wire ropes and trailing cable and provision of new clamps in place of damaged ones, replacement of wire ropes if found damaged without dismantling of pole (if possible) as per instruction of IOCL site engineer. New Clamps of stainless steel material only is to be provided. Supply of Wire, rope shall be paid vide separate line item.5. Replacement of damaged flexible trailing cable from pole mast terminal box to light fittings as per instruction of IOCL site engineers. Supply of Cable shall be paid vide separate line item.6. Checking of alignment of the high mast pole, alignment of fittings with respect to pole, checking of inner ring of lighting carriage and replacement of rubber pad if required, Tightness of pole base bolts and alignment of pole with respect to ground as per instruction of Site Engineer.7. Lowering and raising of FLM fittings smoothly in presence of IOCL site engineer.8. All consumable items such as drill bit, hammer bit, nut-bolt, rubber seal packing, grease or gear oil, CRC, Easy clean & other relevant tools-tackles shall be supplied by the contractor. No additional claim shall be entertained for consumable items apart from SOR.9. Maintenance of HMT feeder pillar including replacement of faulty MCB, contactor, wire re-lugging & circuit fault rectification etc. MCB, Contactor shall be supplied by owner. 10. Contractor shall submit signed & stamp copy of IOCL checklist after job completion for each high mast tower.11. All consumables such as Nut-Bolt, gear oil, grease, lugs, Putty, Easy clean, cutton waste etc shall be supplied by Contractor without any extra claim. Separate item shall be paid as per SOR line item only. Unit of Measurement \\"EA\\" indicates individual High Mast Tower |
| 154 | Pre-cyclone HM Lowering works:Supply of PVC ropes, providing service for lowering all High Masts, covering of all LED lights with properly wrapped plastic with PVC ropes, checking tightness of luminaire structure bolts, after cyclone, restoration of site complete in all respect. |
| 155 | Head frame Repair maintenance: Head frame maintenance including replacement of bush of gun metal or bearing with complete alignment if required. (in case of pulley damaged or alignment out) as per direction of EIC. |
| 156 | Winch/Spur Gear Repair maintenance: Supply and fixing of spur gear of HM complete with replacement of bush of gun metal and alignment, fixing with the HM , successful trial run and operation of the gear for lowering and raising of lighting carriage in presence of IOCL engineer. The job should be completed with all man, materials and tools and tackles as per Direction of EIC. |
| 157 | Supply of Head Frame Galvanised:Supply of Head Frame Galvanised for 30M |
| 158 | Supply of Lantern Carriage rest stand:Supply of lanten carriage rest stand |
| 159 | Supply of winch stand:Supply of winch stand. |
| 160 | Supply of winch gear:Supply of winch gear |
| 161 | Supply of Lantern Carriage:Supply of Lantern Carriage suitable for mounting existing Luminiares of High Mast. |
| 162 | Supply of Motor Handle:Supply of Motor Handle to be used for High Mast. |
| 163 | Supply of GI Fastner (M16x40mm): Supply of GI fastner sets of M16x40 mm |
| 164 | Supply of GI Fastner (M16x105 mm): Supply of GI fastner sets of M16x105 mm |
| 165 | Supply of GI Fastner (M19x40 mm): Supply of GI fastner sets of M19x40 mm |
| 166 | Supply of GI Fastner (M12x35 mm): Supply of GI fastner sets of M12x35 mm |
| 167 | Supply of GI Fastner (M10x25 mm): Supply of GI fastner sets of M10x25 mm |
| 168 | Supply of Trailing cable Clamp with single Hole:Suppy of HM Trailing Cable clamp with Single hole. |
| 169 | Supply of Trailing cable Clamp with double Hole:Suppy of HM Trailing Cable clamp with double hole. |
| 170 | Suppy of Wire rope clamp:Suppy of HM Wire rope clamp. |
| 171 | Supply of Male-Female Plug:Supply of Male-Female Plug for Trailing cable of High Mast. |
| 172 | Supply & fixing of thimble, lugs:Supply & fixing of thimble, lugs. |
| 173 | Supply of 90W NFLP LED FLOOD LIGHT:Supply of 90 W NFLP LED Flood Light of reputed brand make as per specifications, complete with driver, mounting accessories and warranty. |
| 174 | Supply of 150W FLP LED FLOOD LIGHT:Supply of 150 W FLP LED Flood Light of reputed brand make as per specifications, complete with driver, mounting accessories and warranty. |
| 175 | Supply 350W NON-FLP LED FLOOD LIGHT:Supply of 300 W FLP LED Flood Light of reputed brand make as per specifications, complete with driver, mounting accessories and warranty. |
| 176 | SIC of 62Meters SS WireRope 7/19 con:Supply and fixing of 62Meters SS WireRope 7/19 for HM. Unit of measurement \\"EA\\" indicates individual High Mast Tower . |
| 177 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 90W)/LED chip (rating upto 90W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 178 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 120W)/LED chip (rating upto 120W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 179 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 150W)/LED chip (rating upto 150W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 180 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 300W)/LED chip (rating upto 300W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 181 | Repairing of LED Lights:Repairing of lights by replacing of defective LED drivers or LED chip including supply of LED driver (rating upto 500W)/LED chip (rating upto 500W) asper requirement and direction of Engineer In Charge / Site Engineer. |
| 182 | Supply of Photo Senser :Supply of Photo Senser as per direction of EIC. |
| 183 | Supply of street Light Junction Box(J.B):Supply of street Light J.B (16mm SWH Sheet) G.I Size - 2.50 mm x 250mm x10mm including supply of 2 nosclamp (19mm x3) G.I strp also direction of EIC. |
| 184 | Installation of trailing cable:Installation of 5C x 4 sqmm copper conductor EPR insulated & PCP sheathed trailing cable for High Mast. Unit of measurement \\"EA\\" indicates individual High Mast Tower. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail