| 1 | Supplying, Installation, Testing and Commissioning of Electrical Measurement, Electrical Workshop, Electrical Machine & Power System Laboratory Equipments/Machineries of Electrical Engineering Department at TTAADC Polytechnic Institute, Khumulwng, West Tripura under the NEC Scheme \\"Improvement of Infrastructure in TTAADC Polytechnic Institute, Khumulwng, West Tripura, District Under Higher Education Department.\\" (2nd call) |
| 2 | Kelvin Double Bridge Trainer KitThe instrument should have following features :• Easy illustration of Kelvin's bridge• Digital display (DPM) for null detection• Online product tutorialThe instrument should have following Technical Specifications :DC Power Supply : +5VKnown Resistance : R1=100KΩ, 20KΩ, 10KΩ R3=1KΩ, 200Ω, 100ΩDPM : 2VDimensions (mm) : 240 W x 345 D x 110 HUnknown Resistance : 0.3Ω, 0.4Ω, 0.8ΩMains Supply : 230 V ±10%, 50 Hz |
| 3 | Whetstone Bridge Trainer KitThe instrument should have following features :Sample : Constantan, NichromeProvided with DC Power Supply Compact designEasy to operateThe instrument should have following Technical Specifications:DC Power Supply:5VGalvanometerDeflection:30 - 0 – 30Resistance:80ΩUnknown Resistance Type: VariableRange:0 - 10kΩWire Samples: -Constantan: 1mNichrome:1mFuse:500mAMains Supply: 90 - 275V, 50HzDimensions (mm):W 345 x D 240 x H 110 |
| 4 | Experimentation with De Sauty's and Schearing BridgeThe instrument should have following features: -• A Complete set up with all necessary accessories• Inbuilt 1 kHz sine wave generator with variable amplitude• Null detector with DPMTechnical Specification: -Sine Wave GeneratorFrequency range:1kHz ±10%Amplitude control output: Up to 15VppFuse:500 mA, S/BDPM:200 mVUnknown Capacitor:0.1μF, 0.22μF, 0.47μFMains Supply:230V AC, ±10%, 50HzDimension (mm):W 345 x D 240 x H 110 |
| 5 | Experimentation with Maxwell's BridgeThe instrument should have following features : Illustration of both Maxwell's inductance bridge and Maxwell's inductance-capacitance bridge on a single board Inbuilt 1 kHz sine wave generator with variable amplitude Null detector with DPMThe instrument should have following Technical Specifications :Mains supply : 230 V ±10%, 50 HzDC Power supply : +12V, -12VSine wave generatorFixed Frequency : 1KHz ±5%Amplitude Control Range : Upto 20VppUnknown Inductors : 10 mH, 20mH, 30 mH, 56μH, 24μH, 12μHDPM : 200mVUnknown Internal Resistance : 470W, 10 , 20 , 30Dimensions (mm) : W 240 x D 345 x H 110 |
| 6 | Measurement of Three Phase Active & Reactive Power with Single Phase Wattmeter Technical specifications:Analog Meters:• Analog Voltmeter, Range : 300V• Analog Ammeter, Range : 2A• Analog Wattmeter Power Supplies:• Operated on Mains power 415V, 50Hz +10%Components are mounted on the panels are:• Capacitive Load Inbuilt• Inductive Load Inbuilt • Resistive Load (External)Salient Features:• Three Phase Power Light Indicator for Mains.• Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols.• MCB for Short Circuit protection• Connections are brought out through 4mm Colored Safety Sockets.• Patch Cords 4mm.• The trainer is housed in Metal cabinet.• Size of the trainer set 36 x 24” |
| 7 | Power & Power Factor Measurement by CT & PT in Three Phase CircuitTechnical specifications:Power Supplies:• AC Power Supply 0-415V AT 4A• Operated on Mains power 415V, 50Hz +10%Digital Meters: • Digital Voltmeter • Digital Ammeter , Digital Wattmeter (Analog), Digital Power Factor Meter Components are mounted on the panels are:• 3 Phase Capacitive Load (Inbuilt)• 3Phase Resistive Load (External)• 3Phase Inductive Load (External)• Emergency Stop • Current Transformer• Potential TransformerSalient Features:• Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols.• Three Phase Indication through 25mm Indicators• Patch Cords 4mm (Heavy Duty) 1Meter Length. • High Voltage Test Points are Provided With 4mm Safety Sockets• The trainer is housed in Rack Type Channel Extruded Panel• Panel is modular based easy to place and remove the Module. • Short Circuit protection with the MCB.• Size of the trainer set 30” x 24” Scope of Supply: • Electrical Trainer• 3 Phase Auto Transformer• 3 Phase Resistive Load• 3 Phase Inductive Load• 4mm Patch Cords 1Mtr. Length, Potential Transformer |
| 8 | Extend range of Ammeter & Voltmeter using i) Shunt & multiplier ii) CT & PTConversion of Galvanometer to Voltmeter & AmmeterTechnical Specification:- Power Supplies:• DC Supply IC Regulated 0-10V DC, 150mA.• Operated on Mains power 230V, 50Hz +10%Analog Meters:• Analog Voltmeter 10V DC• Analog Ammeter 50mA DC• Analog Galvanometer 30-0-30, 20uA/Div.Components are mounted on the panels are:• 4 Different Variable Resistor are given on Board. • 6 Different Resistor are given on Board.• On Board Half Deflection Method given to Measure the internal resistance of Galvanometer.• On Board Galvanometer to Voltmeter Conversion Circuit Given.• On Board Galvanometer to Ammeter Conversion Circuit Given.Salient Features:• Front panel built with high class insulated Printed Circuit Board sheet with well printed circuits and symbols.• Connections are brought out through 4mm Colored Safety Sockets.• Patch Cords 4mm.• The trainer is housed in ABS Plastic cabinet.• Size of the trainer set 12” x 10 |
| 9 | Single Phase kWh meter with LCD displayRange : 5-30A |
| 10 | 3 Phase 4 Wire kWh meter LCD TypeRange : 5-30A |
| 11 | Hand Driven Insulation Testing (Megger)Product Features:• Rugged design to withstand industrial environment• Metal body with collapsible Steel handle• In-built hand-driven brushless AC generator and static rectifier to supply Stabilized DC voltage• Guard terminal to eliminate surface leakage current• Cross coil movement, sintered anti-friction bearings and delrin-moulded gears ensures trouble free operation• 66mm logarithmic scale confirms to IS 2992-1987Technical Specification:Test Standard : IS 2992-1987Accuracy : ±5% in the first effective range ±10% in the first effective rangeAs per clause 9.1 of IS 2992-1987Terminal Voltage Setting at Rated Resistance : +10% of rated voltage Voltage Stability at rated resistance speed 160 to 240 RPM : -2% to +4% of terminal voltage Ripple Content at 160 RPM : <10% of the rated VppHigh Voltage Flash Test : with stand 2KV AC (rsm) between the electrical circuit & the handle for 1 minInsulation Resistance : >50MΩ at 500V between electrical circuit and he training caseRange:I. Insulation Resistance : 0-100MΩ, Test Voltage : 500VII. Insulation Resistance : 0-200MΩ, Test Voltage : 500VIII. Insulation Resistance : 0-500MΩ, Test Voltage : 500VIV. Insulation Resistance : 0-100MΩ, Test Voltage : 1000VV. Insulation Resistance : 0-200MΩ, Test Voltage : 1000VVI. Insulation Resistance : 0-500MΩ, Test Voltage : 1000VStandard Accessories:01. A pair of testing leads 1 Meter length 02. Instruction Booklet03. Test Certificate |
| 12 | Digital Trip RelayThe set will comprise of following modules :- (1) Single phase AC input supply panel will consist of : a) 1 phase/2 pole MCB of 10/15A – 1 Nos, b) Bulb load . (2) Separate Power and control Contact Unit:- a) With separate input output and coil terminals bought out on the panel board (3) Panel will consist of : a) Counter Timer b) Separate auxiliary supplies for coil contacts of relay (4) 230/220 VAC, 1KVA, Isolation Transformer Panel will consist of : Transformer Panel Consists of all the connections of transformer primary and secondary will be brought on the top of panel. (5) Digital Trip Relay along with Protection relay type should consists of : Aux. supply 220VAC Digital Trip Relay. trainer kit with – Relay – 2 no. on Time Delay Relay– 2 no. Aux. DC voltage source for relay – 1 no. Digital time counter – 1 no. Trip Alarm circuit with buzzer – 1 no. With required power supply, DP MCB, indicator, connecting terminals, sockets, Alarm, tripping circuits, operating manuals etc With required power supply, DP MCB, indicator, connecting terminals Sockets, Air break contact with 3 no, NO for power ckt and 1no NO and 1no NC for control ckt, operating manuals etc. |
| 13 | Determination of Load characteristics of D.C. generators. Technical Specifications 5 HP / 440VAC /1500 RPM / 3phase Induction Motor Coupled with /self excited DC Compound generator/220VDC/1500RPM. :1 Set3 phase main switch 32 A Star Delta Starter – 5HP,with 4 point Starter DC: 1 No eachDC Voltmeter /Portable/150/300V : 2 NosDC Ammeter /Portable/15/30A : 2 NosDC Ammeter /Portable/1.5/3A : 2 NosRheostat 750 E / 2 Amp; 2 NosAC Voltmeter /Portable/150/300V : 2 NosAC Ammeter /Portable/15/30A : 2 NosAC Ammeter /Portable/1.5/3A : 2 NosRheostat 750 E / 2 Amp : 2 NosSingle Phase loading rheostat-3KW: 2 NosAccessoriesHYLEM Sheet with following accessories1. Banana connectors2. Fuse Holders3. DC MCB4. IndicatorsDigital speed indicator with speed sensor & mounting accessories on motor shaft |
| 14 | Rectifier, Distribution Panel & AccessoriesProduct Features:• It enables switchgears, instrument and protective gears used in normal switchboard to be demonstrated and their functions explained.It is excellent practice units for students to study its circuitry, dismantle and reassemble component parts rewire.Compartment doors/covers are hinged and can be opened manually by finger operated screws.Technical Specifications:Input: 415VAC, 400A, 3-phase, 50Hz Incomer Panel:• 1 No MCCB 400A TPN, 25KA c/w Shunt Trip CoilInstruments:• 3 Nos 22nim Pilot Lamp (R/ Y/B) Main Phase Lamp• 1 No Power Factor Meter, 415V• 1 No Ammeter, range 0-400A c/w Selector Switch1 No Voltmeter, range 0-500V c/wConstruction: Physical Size : Approx. 1300H X 1100W X 450D in mm Console : Heavy Sheet Steel Finish : Baked epoxy powder in matching grey & whiteMarking : Engraved / label printing legends |
| 15 | Variable (Single Tube) rheostat: 0-100 ohmTechnical Specification The resistance Materials are wound on Ceramic tube.Current rating: 0-5 AVoltage: 230/240 VPower Rating: 1-2 KwFrequency- 50 Hz |
| 16 | Variable (Single Tube) rheostat: 0-400 ohmTechnical Specification The resistance Materials are wound on Ceramic tube.Current rating: 0-2 AVoltage: 230/240 VFrequency- 50 Hz |
| 17 | Variable (Single Tube) rheostat: 0-200 ohmTechnical Specifications The resistance Materials are wound on Ceramic tube.Current rating: 0-4 AVoltage: 230/240 VFrequency- 50 Hz |
| 18 | Variable (Single Tube) rheostat: 0-50 ohmTechnical Specifications The resistance Materials are wound on Ceramic tube.Current rating: 0-10 AVoltage: 230/240 VFrequency- 50 Hz |
| 19 | Insulation Testing Megger Technical Specifications• Metal Body• Housed in Anti-magnetic aluminium body• Metallic flap over glass window• Scale length: 90mm (approx.)• Rotation speed: 160 or more r.p.m• Weight: 2.5 kg (approx.)• Dimensions (in mm): 110x128x195 (approx.)• Analog type |
| 20 | Earth Testing Megger Technical Specifications• Metal Body• Housed in Anti-magnetic aluminium body• Metallic flap over glass window• Scale length: 90mm (approx.)• Rotation speed: 160 or more r.p.m• Weight: 2.5 kg (approx.)• Dimensions (in mm): 110x128x195 (approx.)• Analog type |
| 21 | Switch Bus-Bar ModuleFeatures :-● Connects other parts of equipments Electrical Systems range to create realistic and meaningful electrical power systems with characteristics typical of industrial plant ● Allows creation of fully functional electrical power systems so students can observe the interaction between elements ● Double busbar with six bi-directional feeders● Separate radial circuit with one incoming and three outgoing feeders● Built-in industrial-standard digital protection relays give wide range of functions ● Includes point-on-wave circuit breaker for switching transient investigations ● Fitted with socked for additional protection relay for more experiments● Introduces unit protection● Includes circuit protection instruments and controls● Two separate three –phase fault switches(one with a digital timer)allow students to apply a range of faults and monitor their effects on the whole systemStandard features● Supplied with comprehensive user guide , Five-year warranty, Manufactured in accordance with the laters European Union directivesTechnical SPECIFICATIONSNet dimensions and weight1850 mm x1870 mm x960 mm and 520 kgPacked weight 650 kg Double bus circuit: ● Six bi-directional feeders each with circuit breakers voltage and current meters and protection CTs for connection to the protection relays ● Two circuit – breakers to break each half of the bus ● Twelve bus isolators six on each half of the bus● Two circuit-breakers that break the coupling between the main and reserve bus Radial circuit:One incoming and three outgoing feeders, each with circuit breakers, voltage and current meters and protection cts for connection to the protection relays.PROTECTION RELAYS:Two identical industrial-standard digital relays for connection to the CTs around the circuits, for standard protection and zone protection. |
| 22 | Transformer TrainerFeatures• Control panel with digital microcontroller based measuring devices with high accuracy and resolution• Transformer winding consist of copper or high grade material for long term service, Control Panel with back door for better understanding its internal wiring with ease• Front board and consists of MS Material with power coating to avoid any rust.• Separate auxiliary supply will be required to actuate digital measuring devices• Panel with round grills fitted on both sides for cooling.• Provided with suitable protection such as fuses, MCB, etc wherever requires• Specially designed BS10 Terminals and patch cords to eliminate electrical shock• Lamp indicator for single phase supply• Earthing screw provided at the back side of the control set-up, Diagrammatic representation for the ease of connections., Product should be provided with protection fuses, colored patch cords, single phase/ three phase cords, learning manual having theory operating procedure with connecting diagram, FAQ, Glossary, etcTechnical SpecificationsMains Supply: Single Phase, 230V AC ±10%, 50HzSingle Phase Transformer (2Nos), Rating: 1000VA Primary Voltage : 0-125V-0-125V Secondary Voltage : 0-125V-0-125V Rated Current : 4AWinding : CopperEfficiency : Above 90% (considering experimental losses),Type : E-I Core, Digital Meters Used, Technology Used : Microcontroller basedAC Voltmeter (72 x 72mm) : 500V (2nos.)AC Ammeter (72 x 72mm) : 10A (2nos.)Wattmeter (96 x 96mm) : 1.5kW Protection Devices MCB (DP): 6A , Glass Fuse : 5AGrounding Nut : Available at the rear side of the panelSupporting Accessories supplied with Control Setup• Patch Cords of different color scheme• Single Phase Mains Cord• Extra Glass Fuses• Learning Material Manual resistive Load, 1.2Kw (Included) |
| 23 | Transmission Line SimulatorCONTROL PANELFitted on ENGRAVED BAKELITE Sheet Enclosed in Almirah type M.S. Box suitable for Table Mounting.Technical Specifications• Main Supply: 230V, AC, 50 Hz• MCB Two pole AC16 Amp, 250 Volt – 01 No.• Indicating Lamps LED type 22.5mm size• AC Multi-function Meter 5A Flush type-02 Nos. for Sending and Receiving Ends capable of measuring voltage Current active and reactive power, Apparent power Frequency• 6 Amp Single-Phase Continuously Variable Autotransformer -01 Nos.• Required number of Resistive loads, Capacitive loads, Inductive LoadsSingle Phase transmission line1 kVA, 220V, 50Hz Naturally, air-cooled, all the distributed parameters are formed in T & pie- sections with a complete length of line 180 KMs; all the terminals are brought over to a Bakelite/Acrylic sheet and fitted on its front side through insulated terminals, and the line model can be configured to SHORT, MEDIUM and LONG Transmission Lines.List of Experiments1. To study Short Circuit, Medium, Long Transmission Line2. Determine the ABCD, H, Z and Image parameters of Short Transmission Line3. Determine the ABCD, H, Z and Image parameters of Medium Transmission Line for T network and for pi network4. Determine the ABCD, H, Z and Image parameters for Long Transmission Line5. Measure the receiving end voltage of each line under no load or lightly load condition to understand Ferranti effect6. Understand the performance of transmission line under different loads |
| 24 | Distribution TrainerIt should have following features:• Inbuilt DC Variable Supply• Digital Panel Meters• Separate sections for Ring Main and Radial Distribution System• Facility to configure balanced and unbalanced network• Equipped with Supply Indication Lamp• Designed by considering all the safety standards• Equipped with bulb holders to use load• Should provide online product tutorial.It should have following Technical Specifications:• Mains Supply : 230V ±10%V AC, 50Hz• Inbuilt Isolated DC Output SupplyRated Voltage : 0 - 220V ±10% (Variable)Rated Current : 2A• TransformerRating : 0.5kVAPrimary Voltage : 230VSecondary Voltage : 150V• VariacInput : 230VOutput : 0-270VCurrent : 2A• Digital DC Voltmeter (3 Nos.)Range : 20-500VDisplay Resolution : 1V• Digital DC Ammeter (3 Nos.)Range : 0-5ADisplay Resolution : 0.01A• MCB : 2A (SPN) |
| 25 | Circuit Breaker TrainerFeatures: -• Alphanumeric 16X2 Big Font LCD for better visibility• Isolated Power Supply using Transformer• Inbuilt variable current injection facility• Transparent MCB's to understand internal architecture and its working• Inbuilt Timer, Current & Temperature on LCD• MCBs are mounted with temperature sensor for current temperature analysis• Equipped with supply indication lamp• Designed by considering all the safety standards• Diagrammatic representation for the ease of connections• Learning material Technical Specification: -Mains Supply:0-220V AC ±10%, 50Hz Single Phase VariacInput:230VOutput:0-270VCurrent:10ASingle Phase TransformerRating:1kVAInput:230VOutput:230VExperimental Setup MCB’s:B type, 6AC type, 2A HRC Fuse:6ATemperature Sensor (2 Nos.)Type: Mounting typeName: LM35Display Resolution:0.1°CMounting: With Brass holder mounted on MCB’sProtective Devices: 10A (SPN)Rheostat:100 / 5ADimension (mm):W 600 x D 350 x H 450Weight:22kg (approximate) |
| 26 | AC GENERATOR PROTECTION PANEL SIMULATION UNITCONTROL PANELFitted on ENGRAVED BAKELITE Sheet Enclosed in Almirah type M.S. Box suitable for Table Mounting.Technical SpecificationsMG Set Section –• Mains Supply – Single Phase, 230V, 50Hz• DP MCB 16 Amp, 220V -1 No.• Inbuilt DC Power Supply -1 No.• Digital DC Voltmeter 48 x 96 mm, 0-300 V -2 Nos.• Digital DC Ammeter 48 x 96 mm, 0-20 Amp -1 No.• Digital DC Ammeter 48 x 96 mm, 0-2 Amp -1 No.• Digital AC Voltmeter 48 x 96 mm, 0-500 V -1 No.• Digital AC Ammeter 48 x 96 mm, 0-10 Amp -1 No.• Digital Frequency Meter 48 x 96 mm -1 No.• Digital RPM Meter -1 No.• 3 Point DC Starter 3 HP, face platetype -1 No.• TPN MCB 16 Amp, 440V -1 No.• Excitation controlling arrangement -1 No.• Field Rheostat 1.4 A, 260 Ohms -1 No.• Indicating Lamps -2 Nos.• Insulated terminals• Patch chords.Alternator Protection Section –• Over Current & Earth Fault Protection Relay• Excitation Failure Protection Relay• Reverse Power/Prime Mover Failure Protection Relay• Unbalanced Load Protection Relay• Under/Over Voltage Protection RelayMACHINES REQUIREDM G SET : D C SHUNT MOTOR/3 PHASE ALTERNATORDC MotorType : DC Shunt wound, screen protected. Horizontal foot mounted. Capacity : 2 HPRPM : 1500 to be displayed on Panel Board using Proximity Sensor fitted on shaftVolts : 230Insulation : Class ‘B’Cooling : Fan cooledConnections : All the terminals of armature and shunt field shall be brought over to a bakelite sheet, fixed to C.I. terminal box, fitted on top of Motor.AlternatorType : Salient pole type (Dove Tail type construction with damper windings), 3-phase 4 wire screen protected, horizontal foot mounted, fan cooled, separately excited with damper winding.Capacity : 1 KVARPM : 1500Volts : 415VInsulation : Class ‘B’Frequency : 50 HzPower factor : 0.8 p.f laggingConnections : 3 phase 4 wireBase Plate & CouplingMotor and Generator will be mounted on fabricated base plate of MS channel base. Motor and Generator are coupled with a flexible tyre coupling & mounted on a common M.S. base. Coupling guard is also provided. |
| 27 | Static VAR CompensatorTHE PANEL WILL CONSIST OF:- Thispanel set-up indicates how the power factor falls with increase of R-L loads in the system and also its improvement (either manually or automatic) by means of VAR Compensator. The user gets die provision to set a desired power factor of the system and increase the loads till the p.f. falls below the set value and ones it does so, the Var Compensators provided will automatically get into circuit to increase the p.f. above the set value. If the user wants then this automatic system can be made manual also.The panel structure includes:• Bus bars• Multiple R-L loads• Var Compensators. (basically these are capacitor banks of ‘l Kvar' each)• Microcontroller based IPFC relay.• Wattmeter : Range : 0-3KW………Quantity : 1 • Digital Voltmeter : Range : 0-300V………Quantity : 1 • Digital Ammeters: Range : 0-10A…………Quantity : 1 • Main ON-OFF switch /MCB/fuse. • LED indicator. • Fuse protection. • Overload protection. • Off on switch and power plug. • All equipments /Instruments fitted on a Bakelite panel board with table top self stand. • MS angle Frame with required connecting terminals , patch cords, • Mains cords, instruction /operating Manual etc Brief Description/Specifications: • Examines the distribution efficiency, voltage drop and voltage regulation. • Shows effect of line losses and efficiency. • Built in industrial standard digital protection relays with wide range of functions. |
| 28 | 3 Phase Active & Reactive Power Control The set will comprise of following modules:- (1) Input single phase/Three Phase MCB panel will consist of : a) 4 pole / 2 pole MCB of 415V/10 A & 220 V/10A, b) Bimetallic thermal O/L relay with range 1.4A – 2.3A. (2) Variable voltage and current Injector panel will consist of : a) 1 phase dimmer of rating 0-230VAC/0.75A, b) Toroidal current injecting transformer of 100VA with primary 230VAC/1A, secondary-0-2-8V/12A.(3) Single Phase wattmeter a) With separate input output terminals bought out on the panel board (4) CT panel will consist of : a) 5/5 Amp. CT 6 Nos. b) Primary side of CTs connection should brought on 3 x 2 x 2 SBS-5 sockets. c) Secondary side of CTs will be Star connected in group of 3 & brought out on 4 x 2 SBS-5 sockets.(5) 230/220 VAC, 1KVA, Isolation Transformer Panel will consist of : Transformer Panel Consists of all the connections of transformer primary and secondary will be brought on the top of panel. (6) Transmission line Panel will consist of : a) Simulated model for transmission line (250kms) using R (10 ohm/600W), L(0.15H/5A) & C (2.2Uf / 630V) b) Simulated model for medium/long length transmission line for Pi model. c) Simulated model for medium/long length transmission line for T model. d) Optionally 2 transmission line panels supplied to simulate up to 500kms length. (7) RLC load panel - Table Top Panel will consist of a) 3 nos. of 600W resistors with switch selectable 7 nos. of taps at 100, 112, 125, 150, 175, 200 & 225, b) 3 nos. of inductor 1.5H/1A with switch selectable 6 nos. of taps at 0.3, 0.6, 0.75, 0.9, 1.2 & 1.5H, c) Capacitors 440VAC rating (3 nos. one per phase) with switch selectable 7 nos. of value of 2, 5, 10, 15, 20, 30 & 50μF.Synchronization Panel will consist of : • No. Alternator: 3KVA/440V/50Hz • 2 No. DC Compound Motor: 3KW/220V Panel board for the experiment consists of M. S. Channel, Bakelite board. It includes the following: • Variac (Single phase) for speed control of DC Motor. (2 No.) • Field Regulator for DC Motor (2 No.) • Field Regulator for Alternator. (2 No.) • Synchroscope • Bulbs (3 No.) • 2 No. DC Voltmeter(0-300V) • 2 No. DC Ammeter(0-15A) • 2 No. AC Ammeter(0-10A) • 3 No. AC Voltmeter(0-500V) • 2 No. DC Ammeter(0-5A) • Frequency meter • Synchronizing switch • Phase sequence indicator. • MCB • Main ON-OFF switch /MCB/fuse. • LED indicator. • Fuse protection. • Overload protection. • Off on switch and power plug. • Electrical loading arrangement with minimum 6 steps variation capability (Lamp load) • All equipments /Instruments fitted on a Bakelite panel board with table top self stand. • MS angle Frame with required connecting terminals , patch cords, • Mains cords, instruction /operating Manual etc |
| 29 | DC Network Analyzer The set up will consist of :-• 1phase MCBs of 4A/1.6A - 1no each, Bulb Load.• Consist of 1 phase dimmer 230VAC/2A……2Nos.• Consist of 5/5 Amp. CT 6 Nos. Primary side of CTs are brought on 3 x 2 x 2 SBS-5 sockets. Secondary side of CTs are Star connected in group of 3 & brought out on 4 x 2 SBS-5 sockets.• Built in 0 – 50V, 2A DC regulated Power Supply with over-load, short circuit protection• wire wound resistances (± 5%) having the values mentioned below• 5, 10, 20, 25, 50, 75, 100, 200, 10 W, 0.5k,1.0k, (5W each), 1.5k, 2.0k, 2.5k (2.5W each),5.0k, 7.5K,10K, (1W each), equipped with 2 A SPST Switch with each resistor• Terminal sockets (3 colours ),6A main Switch• Patch chords 30 pcs (1’, 2’ and 3’ length, 15 red+15 black)• Built in digital ammeter (0-100 mA) and voltmeter (0-50 V) Panel type• Main ON-OFF switch /MCB/fuse.• LED indicator.• Fuse protection.• Overload protection.• Off on switch and power plug.• Electrical loading arrangement with minimum 6 steps variation capability (Lamp load)• All equipments /Instruments fitted on a Bakelite panel board with table top self stand.• MS angle Frame with required connecting terminals , patch cords.• Mains cords, instruction /operating Manual etc |
| 30 | Resistance Box (Three Dials) 30 1 ohm 1,110 ohms30 10 ohms 11,100 ohms30 100 ohms 1,11,000 ohms30 1000 ohms 11,10,000 ohms |
| 31 | Resistance Box (Four Dials) 40 1 ohm 11,110 ohms40 10 ohms 1,11,100 ohms40 100 ohms 11,11,000 ohms |
| 32 | Resistance Box (Five Dials) 50 1 ohm 1,11,110 ohms50 10 ohms 11,11,100 ohms50 100 ohms 1,11,11,000 ohms |
| 33 | Resistance Box (Six Dials) 60 1 ohm 11,11,110 ohms60 10 ohms 1,11,11,100 ohms |
| 34 | Resistance Box (Single Dials) DRBC-115U 10 .1 ohm 1 ohmDRBC-115P 10 1 ohm 10 ohmsDRBC-115Q 10 10 ohms 100 ohmsDRBC-115R 10 100 ohms 1,000 ohmsDRBC-115S 10 1 K ohms 10 K ohmsDRBC-115T 10 10 K ohms 100 K ohms |
| 35 | Resistance 1k,2k,3k,5k (50 nos each) |
| 36 | Led light of different colour Max 3 colour (5 nos each colour) |
| 37 | AC/DC Digital Multimeter(0-750v,0-20A,0-3k) |
| 38 | Insulation testing megger (analog) |
| 39 | Earth testing megger(analog) |
| 40 | Led bulb 5W,9W (40 Nos. each) |
| 41 | Bulb 100w |
| 42 | Kit-kat types fuse 5amp |
| 43 | Cut-out type fuse 60 amp |
| 44 | Cartage fuse 60/100 amp |
| 45 | HRC fuse 100/200 amp |
| 46 | MCB 6A,10A,12A (5 Nos. each) |
| 47 | MCB board 8 inchx10 inch |
| 48 | ICDP main switch 16 A |
| 49 | ICTP main switch 32 A |
| 50 | 2.5 micro farad capacitor |
| 51 | Fluorescent tube light set |
| 52 | Wire for bread board single core |
| 53 | Diode Different type (PN Junction diode, Zener Diode, LED, Laser diode, Schottky diode, Photo diode) (30.00 Nos each) |
| 54 | Energy meter single phase |
| 55 | Energy meter three phase |
| 56 | 1 mm multi strand copper wire |
| 57 | 1.5 mm multi strand copper wire |
| 58 | 2.5 mm multi strand copper wire |
| 59 | Wooden board for electrical wiring arrangement big size (8 feet x 12feet) |
| 60 | DIFFERENT TYPE OF RELAY TRAINERFEATURES■ Diagram and meter values printed on Vinyl Sticker on the top of the Panel■ All items fitted on Bakelite Sheet■ MCB protection at the input■ Colour coordinated LED indicator for Inp. Supply■ Fitted with required Voltmeter and Ammeters on the panel■ Complete Manual with connection diagram, procedure tables, graphs(if required) and theory■ Shrouded 4mm Safety terminals & patch cords would be provided for Proper safety■ BS10 Cables provided with the trainers■ Training panel should be made of rust free MS cabinet boxTECHNICAL SPECIFICATIONS■ Input:220V AC/50Hz■ Protection at the Input■ Digital 96*96 AC Voltmeter-500V AC■ Digital 96*96 AC Ammeter-50A AC■ Digital Timer 96*96 0-999.9Sec with Reset■ Variable AC Source 0-220V AC■ Variable AC Current Source (0-30A)■ Onboard Digital Overcurrent Relay■ Onboard Digital EarthFault Relay■ Onboard Digital Undervoltage Relay■ Onboard Electromechanical Overcurrent Relay■ Onboard Electromechanical Overvoltage RelayLIST OF EXPERIMENTS■ To perform the digital overcurrent Relay tripping■ To perform the digital earth fault Relay tripping■ To perform the digital undervoltage Relay tripping■ To perform the Electromechanical Overcurrent Relay tripping■ To perform the Electromechanical Overvoltage Relay trippingLIST OF ACCESSORIES■ Closed Single Phase Variac 220V fitted with input and output terminals provided■ Overcurrent Relay Module■ Earthfault Relay Module■ Cables Set■ Experiment Manual |
| 61 | 1 inch casing capping |
| 62 | CT, 440 V,16A |
| 63 | Digital tachometer (0-3000 rpm) |
| 64 | DC Ammeter Range 0-1A : Portable Analog, Bench type DC Ammeter Range 0-1 A, Usage Laboratory, Portable in ABS body |
| 65 | DC Ammeter Range 0-20A : Portable Analog ,Bench type DC Ammeter Range 0-20 A, Usage Laboratory, Portable in ABS body |
| 66 | AC/DC Ammeter Range : 0-30A Portable Analog ,Bench type AC/DC Ammeter Range 0-30 A Usage Laboratory, Portable in ABS body |
| 67 | AC/DC Ammeter Range 0-5A : Portable Analog ,Bench type Ac Ammeter Range 0-5 Usage = Laboratory, Portable in ABS body |
| 68 | AC Ammeter Range : 0-10A Portable Analog ,Bench type Ac Ammeter Range 0-10 A Usage = Laboratory, Portable in ABS body |
| 69 | AC Ammeter Range : 0-20A Portable Analog ,Bench type Ac Ammeter Range 0-20 A Usage = Laboratory, Portable in ABS body |
| 70 | AC Ammeter Range : 0-30A Portable Analog ,Bench type Ac Ammeter Range 0-30 A Usage = Laboratory, Portable in ABS body |
| 71 | AC Voltmeter Range : 0-500V Portable Analog ,Bench type Voltmeter - 0 - 500 v Usage = Laboratory, Portable in ABS body. |
| 72 | AC Voltmeter Range : 0-25V Portable Analog ,Bench type Voltmeter - 0-25 VUsage = Laboratory, Portable in ABS body. |
| 73 | AC/DC Voltmeter Range : 0-300V Portable Analog ,Bench type Usage Lab Portable in ABS body |
| 74 | DC Voltmeter Range : 0-250V Portable Analog ,Bench Use Lab Portable in ABS body. |
| 75 | DC Voltmeter Range : 0-15V Portable Analog ,Bench Type Voltmeter = 0-15VUsage Laboratory, Portable in ABS body. |
| 76 | 1-Phase Wattmeter Range : 150/300/600V,10/20A |
| 77 | Power Factor Controller Set up should be designed to study the working principle of Power Factor control system in 3 phases Motor Load set up. It should consist ofA. APFC Relay with CapacitorB. 3 Phase 3HP Motor LoadC. Panel with meter & Autotransformer(A). APFC (Automatic Power Factor Control) Relay with CapacitorAPFC Relay for Power Factor Correction in Low Voltage applications should measures the actual power factor and Connect or disconnects capacitors to achieve a target power factor. The single phase electronic measuring system should detect the reactive and active component of the network through the current and voltage path. From this it should calculate the phase shift between current and voltage and compares this with the set target power factor.Specification• Micro controller based design• Effective PF control for balanced loads• 6 or 8 stage option• Auto (or) Manual operation• Front panel digital display for PF• Alarms indication• Voltage Input 415V Ac ± 20%, 50 Hz• Current Input 5A / 1A from CT secondary (Field selectable)• Desired PF setting 0.8 lag to 0.8 lead• Capacitor Bank selection 6 stage Capacitor• Necessary inbuilt 3 phase Capacitor bank with different tapping (6 stage) should provided(B). 3 Phase Motor Load 3Ø AC Motor with load set upType 3Ø squirrel cage induction MotorType 3Ø squirrel cage induction MotorPower 3 HPVoltage 3Ø, 415VACSpeed 1440 RPM Feedback Sensor Proximity sensorLoading Spring balance loadingSpring Balance Loading• One number Brake DRUM with spring balance set up should coupled with the above motor• Two numbers of dial indication (0-50KG) for Load measurement in Kg• All should mounted on a powder coated mechanical set up(C) Panel with meter• One number powder coated panel with mimic diagram should printed on front panel• APFC Relay should fixed on the panel with necessary termination for external connection• Necessary MCB, Switch & indicators should provided.• Banana terminals for 3 Phase AC input & Load Output• One number of 3 phase Autotransformer should provided in panel for Unbalance supply simulation. Please Enable Macros to View BoQ information |