| 1 | MGM ROAD SIDE (5 HP SUB 1 SET, 3 HP SUB 1 SET) |
| 2 | Cost towards lifting and lowering of the 5 H.P Sub. P/set from high yielding T/W with 2\\" dia column pipe total depth of 200' with all tools and tackles including labour charges all complete. |
| 3 | Cost towards rewinding of 5 H.P Sub. Motor (3 Phase 415± 10% volts 50 C/S 2900 RPM) by supplying PVC insulated water proof copper wire as per size required changing and fitting thrust plate - 1 No. G.M bearing bushed for top and bottom and fitting rotor into stator after completion of rewinding work testing the motor on load at side all complete |
| 4 | Cost of repairing of 5 H.P Sub. Pump by changing and fitting new S.S pump shaft as per sample changing its 3 Nos. G.M impeller changing 5 Nos. G.M bush locking key and reassembly its pump all complete. complete |
| 5 | Supplying and fitting 4 mm² x 3 Core PVC insulated & sheathed Sub cable of reputed make |
| 6 | Supplying and fitting Cubical type duly painted control panel board consisting 32 Amp. TPN MCCB inbuilt single phase preventor and suitable for star delta automatic starter water level guard with suitable length and size of wire phase indicating bulb in three different colour suitable voltmeter and ampere meter with selector switch make BCH/Havells/Siemens. |
| 7 | Cost towards S/F 2\\" dia column pipe make TATA Or JINDAL Or Reputed Make |
| 8 | Supplying & fitting 2\\" dia Sluice valve ISI Mark |
| 9 | Supplying & fitting 2\\" dia N.R valve ISI Mark |
| 10 | Chemical earthing 3 meters and 80 mm hole size with electrode and chemical compound etc with watering pipe and locking arrangement including soldering, riveting, Jointing G.I flat 50mm x 6mm to all equipments. |
| 11 | Supplying and fixing of 100 Amp. 415±15% volts Change over switch BCH/Havells/Siemens make |
| 12 | Supplying all materials including Cost of G.I, I.S.I pipe of TATA & equivalent medium class all complete job as per specification and direction of E/I(i)80 mm Dia |
| 13 | (ii)50 mm Dia |
| 14 | Laying of G.I Pipe of approved make in trenches with red lead and yarn with socket and screw joints and cutting pipe to sizes and threading ends where necessary etc. all complete as per specification and direction of Engineer-in-Charge.(i)80 mm Dia |
| 15 | (ii)50 mm Dia |
| 16 | Supplying, fitting & fixing of GM ferrule of approved make.(i)12mm to 16mm Dia |
| 17 | Supplying, fitting & fixing of 15mm Dia C.I. plug cock all complete job as per specification and direction of E/I. |
| 18 | Supplying, fitting & fixing C.I.D.F Sluice Valve(i)80mm Dia |
| 19 | (ii)50mm Dia |
| 20 | Cost towards earthwork in excavation (as per IS:3114/1965) for laying G.I Pipe so as to give one-meter average cover over the socket of pipe with disposal of excavated earth within initial lead lift as per specification.(i)80mm Dia |
| 21 | (ii)50mm Dia |
| 22 | STAFF QUARTER (5 HP SUB PUMPSET- 1 NO.) |
| 23 | Cost towards lifting of the 5 H.P Sub. P/set from high yielding T/W with 2\\" dia column pipe total depth of 200' with all tools and tackles including labour charges all complete. |
| 24 | Cost towards rewinding of 5 H.P Sub. Motor (3 Phase 415± 10% volts 50 C/S 2900 RPM) by supplying PVC insulated water proof copper wire as per size required changing and fitting thrust plate - 1 No. G.M bearing bushed for top and bottom and fitting rotor into stator after completion of rewinding work testing the motor on load at side all complete |
| 25 | Cost of repairing of 5 H.P Sub. Pump by changing and fitting new S.S pump shaft as per sample changing its 3 Nos. G.M impeller changing 5 Nos. G.M bush locking key and reassembly its pump all complete. |
| 26 | Supplying and fitting 7/16 (16 mm² x 2 core) Copper cable ISI mark. |
| 27 | Cost towards S/F 2\\" dia column pipe make TATA Or JINDAL Or Reputed Make |
| 28 | Supplying and fitting 4 mm² x 3 Core PVC insulated & sheathed Sub cable of reputed make |
| 29 | Chemical earthing 3 meters and 80 mm hole size with electrode and chemical compound etc with watering pipe and locking arrangement including soldering, riveting, Jointing G.I flat 50mm x 6mm to all equipments. |
| 30 | Supplying and fitting Cubical type duly painted control panel board consisting 32 Amp. TPN MCCB inbuilt single phase preventor and suitable for star delta automatic starter water level guard with suitable length and size of wire phase indicating bulb in three different colour suitable voltmeter and ampere meter with selector switch make BCH/Havells/Siemens. |
| 31 | Supplying & fitting 2\\" dia N.R valve ISI Mark |
| 32 | Supplying & fitting 2\\" dia Sluice valve ISI Mark |
| 33 | Supplying and making Tripod (14’ x 65 mm C.I. Pipe) hanging chain pulley block |
| 34 | Cost towards renovation of light wiring in out side pump chamber & inside switch room by doing short point light wiring 4-point long point light wiring 4 points, 100-watt Street light complete set- 36-watt CFL- 4 Nos. etc all including labour charges all complete. |
| 35 | BOY'S HOSTEL(5 HP SUB. PUMPSET INSTALLED IN TWO DIFFERENT T/W |
| 36 | Cost towards lifting and lowering of the 5 H.P Sub. P/set from high yielding T/W with 2\\" dia column pipe total depth of 200' with all tools and tackles including labour charges all complete. |
| 37 | Cost towards rewinding of 5 H.P Sub. Motor (3 Phase 415± 10% volts 50 C/S 2900 RPM) by supplying PVC insulated water proof copper wire as per size required changing and fitting thrust plate - 1 No. G.M bearing bushed for top and bottom and fitting rotor into stator after completion of rewinding work testing the motor on load at side all complete. |
| 38 | Cost of repairing of 5 H.P Sub. Pump by changing and fitting new S.S pump shaft as per sample changing its 3 Nos. G.M impeller changing 5 Nos. G.M bush locking key and reassembly its pump all complete. |
| 39 | Supplying and fitting 7/16 (16 mm² x 2 core) Copper cable ISI mark. |
| 40 | Cost towards S/F 2\\" dia column pipe make TATA Or JINDAL Or Reputed Make |
| 41 | Supplying and fitting 4 mm² x 3 Core PVC insulated & sheathed Sub cable of reputed make |
| 42 | Chemical earthing 3 meters and 80 mm hole size with electrode and chemical compound etc with watering pipe and locking arrangement including soldering, riveting, Jointing G.I flat 50mm x 6mm to all equipments. |
| 43 | Supplying and fitting Cubical type duly painted control panel board consisting 32 Amp. TPN MCCB inbuilt single phase preventor and suitable for star delta automatic starter water level guard with suitable length and size of wire phase indicating bulb in three different colour suitable voltmeter and ampere meter with selector switch make BCH/Havells/Siemens. |
| 44 | Supplying & fitting 2\\" dia N.R valve ISI Mark |
| 45 | Supplying & fitting 2\\" dia Sluice valve ISI Mark |
| 46 | Supplying and making Tripod (14’ x 65 mm C.I. Pipe) hanging chain pulley block |
| 47 | Cost towards renovation of light wiring in outside pump chamber & inside switch room by doing short point light wiring 4 point long point light wiring 4 points, 100-watt Street light complete set- 36-watt CFL- 4 Nos. etc all including labour charges all complete. |
| 48 | Cost towards flushing of high yield T/W (150 mtrs) through Rig Machine including all labour tools and tackles |
| 49 | GIRL’S HOSTEL (5 HP SUB. PUMPSET INSTALLED IN THREE DIFFERENT T/W) |
| 50 | Supplying & Installation of Submersible pump set suitable for 6” dia borewell running with 3 phases 415±10% volts 50 C/S 2900 RPM having discharge capacity 2600 GPH against a total head of 60 metres with Noryl/G.M Impeller consists of following accessories: -(a) 2½'' dia G.I Column pipe 200’ (10’ long both end threaded one end fitted socket and other end covered by plastic)(b) 3 Core Flat Copper Cable 4 mm² – 1 Coil(c) M.S Clamp 2½'' dia- 2 Pairs(d) C.I.D.F Sluice Valve 2½'' dia- 1 No.(e) C.I.D.F Sluice Valve 2½'' dia- 1 No. |
| 51 | Supplying and fitting Cubical type duly painted control panel board consisting 32 Amp. TPN MCCB inbuilt single phase preventor and suitable for star delta automatic starter water level guard with suitable length and size of wire phase indicating bulb in three different colour suitable voltmeter and ampere meter with selector switch make BCH/Havells/Siemens. |
| 52 | Chemical earthing 3 meters and 80 mm hole size with electrode and chemical compound etc with watering pipe and locking arrangement including soldering, riveting, Jointing G.I flat 50mm x 6mm to all equipments |
| 53 | Supplying triple spur gear type 3 Tonne Capacity chain pulley block suitable for capacity as below with 6m lift complete with load chain and hand chain suitable for above lift tested to 50% over load as per IS 3832 carrying ISI mark. |
| 54 | Cost towards renovation of light wiring in out side pump chamber & inside switch room by doing short point light wiring 4 point long point light wiring 4 points, 100-watt Street light complete set- 36-watt CFL- 4 Nos. etc all including labour charges all complete. |
| 55 | Supplying and fitting 7/16 (16 mm² x 2 core) Copper cable ISI mark. |
| 56 | Cost towards flushing of high yield T/W (150 mtrs) through Rig Machine including all labour tools and tackles |
| 57 | Cost towards S/F 2” Dia UPVC Column Pipe ISI Mark or Reputed make Please Enable Macros to View BoQ information |