| 1 | Distribution Board : |
| 2 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 3 | a) 2+8 Way Enclosure (607711) |
| 4 | b) 2+12 Way Enclosure (607712) |
| 5 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 6 | a) 4 Way Enclosure (607715) |
| 7 | b) 6 Way Enclosure (607716) |
| 8 | c) 8 Way Enclosure (607717) |
| 9 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 10 | a) 4 Way |
| 11 | b) 8 Way |
| 12 | MCB : |
| 13 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. |
| 14 | a) 6-32A SP |
| 15 | b) 6-32A DP |
| 16 | c) 6-32A TP |
| 17 | d) 6-32A 4P |
| 18 | e) 40A / 63A 4P |
| 19 | MCB/ MCCB ENCLOSURE : |
| 20 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. |
| 21 | a) 4 Way |
| 22 | RCCB : |
| 23 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | a) 40A |
| 25 | MCB FOR 3PHASE POWER : |
| 26 | Supplying and fixing 415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing MCB SS enclosure and necessary connection. |
| 27 | a) 6-32A TPN |
| 28 | Circuit & Sub-Main Wiring : |
| 29 | Supplying & drawing of wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. |
| 30 | a) 2 x 22/0.3 (1.5 mm²) + 1 x 22/0.3 (1.5 mm²) ECC |
| 31 | b) 2 x 36/0.3 (2.5 mm²) + 1 x 22/0.3 (1.5 mm²) ECC |
| 32 | c) 2 x 56/0.3 (4 mm²) + 1 x 36/0.3 (2.5 mm²) ECC |
| 33 | d) 2 x 84/0.3 (6 mm²) + 1 x 56/0.3 (4 mm²) ECC |
| 34 | Supplying & drawing of wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. |
| 35 | a) 4 x 56/0.3 (4 mm²) + 2 x 36/0.3 (2.5 mm²) ECC |
| 36 | b) 4 x 84/0.3 (6 mm²)+ 2 x 56/0.3 (4 mm²) ECC |
| 37 | Blank Conduit : |
| 38 | Supplying and fixing PVC Rigid Conduit 'FR' on wall, ceiling with saddles and other accessories as required and mending good damages to building works. |
| 39 | a) 20mm size |
| 40 | b) 25mm size |
| 41 | Point wiring : |
| 42 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 mm²) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5mm²) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]. |
| 43 | a) Average run 6 mtr |
| 44 | b) Average run 8 mtr |
| 45 | C) Average run 10 mtr |
| 46 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 47 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 48 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. |
| 49 | Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 50 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 51 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 52 | Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 53 | FITTINGS & FIXTURES : |
| 54 | SIT&C of Recessed Mounted 2X2 LED Luminaire with Intelligent Inner Edge Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are in line with 2X2 Luminaire. Luminaire should give more volumetric light & higher vertical illumination. Luminaire should be available in Lumen Packs of 3600 lm with different CCT of 6500K. Luminaire should accommodate different color tiles & also accommodate Services like-AC Grill & Smoke detector etc. (PHILIPS RC383B P LED36S-6500 G6 PSU OD WH PIR P OR SIMILAR APPROVED EQUIVALENT). |
| 55 | SIT&C of recess mounted LED light fixture luminare with luminous efficacy of 110 lumen/watt & mimimum flux of 1500 lumen. (PHILIPS DN296B LED15S (GREEN PERFORM SLEEK G2) OR SIMILAR APPROVED EQUIVALENT). |
| 56 | SIT&C of recess mounted LED light fixture luminaire with luminous efficacy of 110 lumen/watt & minimum flux of 1000 lumen. (PHILIPS DN295B LED10S (GREEN PERFORM SLEEK G2) OR SIMILAR APPROVED EQUIVALENT). |
| 57 | SIT&C of surface mounted Square LED light fixture with 15W and 1700 Lumen with Luminous Efficacy of nominal 115 Lm/Watt. (PHILIPS SM261C LED16S 6500 PSU OD WH (SLEEK SURFACE) OR SIMILAR APPROVED EQUIVALENT). |
| 58 | SIT&C of surface mounted LED Batten with 18W and >2000 Lumen with a lumen efficacy >115 Lm/Watt. (BN100C LED20S-6500 PSU L120 GR S4 (SMARTBRIGHT XTRA S4) OR SIMILAR APPROVED EQUIVALENT). |
| 59 | SIT&C of surface mounted LED Batten with 34W and >3800 Lumen with a lumen efficacy >110 Lm/Watt. (BN100C LED40S-6500 PSU L120 GR S4 (SMARTBRIGHT XTRA S4) OR SIMILAR APPROVED EQUIVALENT). |
| 60 | SIT&C of Bulkhead LED light fixture with 6W luminaire. (PHILIPS WT202W LED6S NW PSU S2 PC (ENDURA LED BULKHEAD) OR SIMILAR APPROVED EQUIVALENT). |
| 61 | CEILING FAN : |
| 62 | Supply & Installation of1200mm Sweep,3-Blade 5-star rating AC ceiling fan. (HAVELLS ES-50 OR SIMILAR APPROVED EQUIVALENT). |
| 63 | Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. |
| 64 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 65 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 66 | WALL MOUNTING FAN : |
| 67 | Supply & Installation of \\"Decorative Wall-Mounted\\" oscillating type fan with inbuilt speed controller. The rate shall be inclusive of fixing & mounting accessories. |
| 68 | a) 450mm Sweep wall fan. (HAVELLS AIRBOLL HI-SPEED OR SIMILAR APPROVED EQUIVALENT). |
| 69 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. |
| 70 | EXHAUST FAN : |
| 71 | Supply & Installation of \\"Exhaust Fan\\" with louvres. The rate shall be inclusive of fixing & mounting accessories. |
| 72 | a) 225mm Ventilating fan non-metallic type. (HAVELLS VENTIL AIR-DXR OR SIMILAR APPROVED EQUIVALENT). |
| 73 | b) 380mm, 1PH, 900RPM heavy duty exhaust fan.(HAVELLS TURBO FORCE SP OR SIMILAR APPROVED EQUIVALENT). |
| 74 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 75 | a) 23 cm (9\\") |
| 76 | b) 38 cm (15\\") |
| 77 | Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long). |
| 78 | a) For 23 cm (9\\") Exhaust fan |
| 79 | b) For 38 cm (15\\") Exhaust fan |
| 80 | Earthing : |
| 81 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. |
| 82 | a) 8 SWG GI Wire |
| 83 | Lightning Arrester : |
| 84 | S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium ) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar(4:2:1). |
| 85 | Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: |
| 86 | a) Length above 0.5 Mtr |
| 87 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage for LC installation per storey of building per vertical run. |
| 88 | Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/ Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works. |
| 89 | S & F of GI (Hot Dip) strips 20mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work 4e damages to building works (excluding hire charges of scaffolding). |
| 90 | Making soldered (welding) joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint. |
| 91 | Supply & fixing of Testing joints by 20mm x 3mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required. |
| 92 | Earthing |
| 93 | Earthing with 50mm dia GI pipe 3.64 mm thick x 3.04 mts. Long and 1 x 4 SWG GI ( Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level (a) By TATA-Medium GI pipe. |
| 94 | Excavation of soil for installation of Earth Electrode and filling & ramming. |
| 95 | a) For Soft soil. |
| 96 | Connecting the equipments body to earth busbar including S & F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/ floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. (For Equi-Potential Bonding). |
| 97 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. |
| 98 | a) 8 SWG GI Wire |
| 99 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 100 | Sub-Total = 57,92,527.00 |
| 101 | Add LWC @ 1% |
| 102 | Sub-Total = 58,50,452.27 |
| 103 | Add GST @ 18% Please Enable Macros to View BoQ information |