Tender For Special Repair To Bldg No. P-28 (Or Living Ticca Bn ) Area Under Age(I) Dalhousie Cantt.
Tender Value
38.83 Lakhs
Estimated cost
Bid Submission
04 Jul 2026
2 days left
EMD
77660
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dalhousie → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No. P-28 (Or Living Ticca Bn ) Area Under Age(I) Dalhousie Cantt.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. |
| 4 | Dismantling of wooden boarding, any description, fixed in any position with nails all as specified |
| 5 | Dismantling timber scantlings in any type of work , in any position |
| 6 | Dismanting of wall and ceiling boards any thickness including cover fillets/ GI /Alumnium/wooden frame work boarding of any description , fixed in any position with nails all as specified. |
| 7 | M&L for 20 mm thick Boarding,Softwood 2nd class supplied & fixed with nails in any situation (except flooring and skirting) Clean sawn with butt joints |
| 8 | M & L for clean sawn second class soft-wood in scantlings |
| 9 | Demolition Brickwork or stone/ boulder masonry, built in cement sand mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 10 | M & L for fly ash bricks as in brick work straight or curved on plan exceeding 6m mean radius built in CM 1:6 all as specified and directed. |
| 11 | M&L for taking down chowkats or frames incl shutters (without taking off shutters from frame) n exc 1.5 Sqm complete all as specified. |
| 12 | M&L for taking down chowkats or frames incl shutters (without taking off shutters from frame) exc 1.5 sqm but n exc 4 sqm each complete all as specified. |
| 13 | Box type Steel windows comprised of tubular frame and shutters made out of 1.25mm thick M S sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg welded to F I frame work, including other fittings; hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-026/13 sheet 1/5 to 5/5 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 14 | S&F stainless steel wire cloth 0.40 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed. |
| 15 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane complete all as specified and directed. |
| 16 | S&F pressed steel frame made out of MS sheet 1.25mm thick of size 125x60 mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate complete all as specified and directed. |
| 17 | M&L for cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats complete all as specified and directed |
| 18 | S&F IInd class 35 mm thick hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed |
| 19 | S&F IInd class hard wood glazed and skelton shutters 35mm thick, open rebated and prepared to receive glass or gauze etc (divided into squares) and fitted to chowkats, edges of framing plain chamfered or rounded fitted with cut and mitred bead for securing glass as specified in SSR Part-I section 8.24 (a) supplied and fitted to chowkhats with edges of sash bars and framing moulded complete all as specified. |
| 20 | M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 21 | M&L for preparation and applying two coat of synthetic enamel paint over a coat of pink primer on new wood or wooden surfaces of any description over 10cm in width or girth not otherwise described complete all as specified. |
| 22 | S&F 200 mm long aluminium anodised barrel tower bolt of extruded section and fixed |
| 23 | M&L150 mm size Aluminium handle, cast type, anodised and fixed. |
| 24 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp and stape ( bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolt and sliding bolt of extruded section or cast aluminium alloy and fixed complete all as specified. |
| 25 | S&F for 300mm, Mild steel ordinary rat rail rod pattern springs including roller and roller plate complete supply & fixed complete all as specified. |
| 26 | M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote |
| 27 | M & L 25 mm thick cement concrete type B-0 1:2:4 (12.5mm graded aggregate) as in sub base for flooring all as specified and directed |
| 28 | M&L Virified Ceramic tiles Dark shade 8-10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match neat cement slurry over 15mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match, complete all as specified and directed by Engr-in Charge. |
| 29 | M&L Virified Ceramic tiles Dark shade 8-10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry as in skirting and pointed in white or coloured cement to match neat cement slurry over 10mm screed bed or bedding layer CM 1:3 & pointed in colour cement to match complete all as specified and as directed. |
| 30 | Material & labour for Machine cut kota stone in flooring/trades of steps 16-18mm thick over and including 20 mm thick cement screed base in cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the floor including rubbing & polishing complete and moulding at edge complete all as specified and as directed by Engineer-in-Charge. |
| 31 | M&L for Dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing), rubish off the premises complete all as specified and directed. |
| 32 | Hi Steel Clip in false Ceiling System with Steel Tile 595 mm X 595 mm manufactured out of 0.50 mm thick polyester coil-coated Galvanized Steel having 180 gms zinc coating Coil-coated Steel tile shall have a 20-micron polyester-coated finish on front side and a backcoat of 5-micron alkyd primer. Two sides of each tile shall have raised, piped and stopped to ensure positive engagemant into the spring clip in profile allowing for demolition of individual tiles . The grid susoension system consists two rows of 0.5mm galvanised steel clip in profile of size 38mm installed at 600mm centre to centre spacing to support the tiles.Wall suspesion Wall Suspension angles /Hangersof size 24 mm X 24 mm X 0.4 mm thick are fixed to the roof by expansion fasteners. Wall suspension angles to be made out of coil coated Steel matching the color of the tile. They will be jointed to the clip-in-profile system by hold on clamps. The Tiles/Planks shall be held in place by pressure clips as per manufacturer's instructions for spacing. in the flexible system the hanger and butterfly clip shall replace the suspension angle, complete all as specified. |
| 33 | M&L for granite (of any type) work (table rubbed and polished) 18-20mm thick in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl. cutting, rounding of edges and mirror polishing complete all as specified. |
| 34 | M&L for taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified. |
| 35 | M&L for rendering 20mm thick (in two layer of 10mm+10mm) on brick or concrete/stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in cement mortar 1:6 surface finished even and smooth w/o using extra cement etc complete all as specified and directed by Engr-in Charge. Note:- Necessary additional dubbing if required will be done by contractor and nothing extra cost is admissible in this account. |
| 36 | M&L for rendering 20mm thick (in two layer of 10mm+10mm) on brick or concrete/stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in cement mortar 1:4 surface finished even and fair w/o using extra cement etc complete all as specified and directed by Engr-in Charge. Note:- Necessary additional dubbing if required will be done by contractor and nothing extra cost is admissible in this account. |
| 37 | M&L for rendering 15mm thick cement plaster concrete surfaces or fair faces of brick work in CM (1:6) surface finished even and smooth w/o using extra cement complete all as specified. |
| 38 | M&L for rendering 15mm thick cement plaster on concrete surfaces or fair surface face of brick work in CM 1:4 surface finished even and fair without using extra cement complete all as specified. |
| 39 | Supply only integral water proofing compound. |
| 40 | M & L for water proof cement based putty @ 1 kg (undiluted) per Sqm of average thickness 1mm over the plastered/ old prepared painted surface of wall and sanding of the putty surface with mechanical wall sander (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per the following steps:-Step 1 :- Mix the putty powder by adding water as per manufacturer's instruction and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute.Step 2 :- Apply the first coat of the prepared mixer with the help of fully automatic airless spray machine of putty application finishing the surface even and smooth in level without any undulations.Step 3 :- Allow 6-8 hrs time to dry the putty surfaceNote: Where thickness of putty is required more than 1mm thick, the same shall be made good using POP and than putti shall be applied to obtain even & smooth surface. Nothing extra shall be admissible on this account. |
| 41 | M&L for preparation and applying two coats of oil bound distemper on newly plastered surfaces of wall over a coat of primer complete all as specified and directed by Engr-in Charge. |
| 42 | M & L for water based premium acrylic smooth exterior emulsion of approved colour with excellent dirt pickup resistance with low VOC less than 50, Antifungal / Anti Algai properties in two coats @ 1.79 litre (undiluted) / 10 Sqm diluted with water as per manufacturer's instruction applied over primed surface with fully automatic airless spray machine of paint application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in between subsequent coats of paint over single coat of acrylic water based exterior grade primer @ 0.9 litre (undiluted)/ 10sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine and allow 6-8 hours to dry the surface for painting of finishing coats complete all as specified and directed. |
| 43 | M & L For Cutting holes, depth of hold fast exc. One brick but not exc. Two brick in stone walls in cement mortar/any mortar or for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed |
| 44 | M & l for reinforced cement concrete nomonal mix Type B1 (1:2:4 , 40mm graded crushed stone aggregate)Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed |
| 45 | M & l for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide.complete all as specified and directed |
| 46 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 47 | Ditto, all as per above item but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 48 | Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15 cm thick (below or above ground level) and removal of rubbish beyond MOD land complete all as specified and directed. |
| 49 | M&L for 75 mm thick PCC type C2, 1:3:6 (40mm graded crushed stone aggregate) in Sub -base, floor and pavings etccomplete all as specified & directed. |
| 50 | M&L for chequered cement concrete coloured tiles, homogenious texture glossy finished, chemically coated machine pressed 30 cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry in floor with gray cement and pigment and including 20 mm thick cement screed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge Shade/Colour of tile shall be as approved by the AGE(I). |
| 51 | M&L for PCC 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed |
| 52 | S&f for half round uPVC rain water gutter pipe of size 150-160mm nominal dia of approved make conforming to relevant IS specification fixed along roof slope eged incl neccessary fittings such as sockets ,bends stop ends ,drop ends couplers,gutter connector, central outlet, support etc as per requirements fixed with brand straps support at 1.2m interval as specified and directed |
| 53 | S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 54 | S&F, for 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints,Fixed to wall, complete all as specified and directed |
| 55 | S & F 110 mm bore PVC Bends (SWR) |
| 56 | S&F powder coated anodised aluminium door shutter, aluminium section wt 0.55 kg / mtr including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos. in each door , hinges , anodised aluminium snap beading screws etc complete all as specified and directed by Engr-in Charge. |
| 57 | S&F powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) & tower bolt 02 nos each shutter, making good all the disturbed surface of floor/wall to mathing the adjoining complete all as specified and directed by Engr-in Charge. |
| 58 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief |
| 59 | Sheet glass, 5.5 mm ordinary quality and glazing with glazing pin in square exc 0.5 sq. m in each pane for aluminium door windows |
| 60 | Taking down carefully copper/aluminium point wiring (light ,fan,socket or power) complete fixture and fittings such as switches ,ceiling rose, regulators,sockets etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separatly) and making good disturbed surfaces of wall, floors etc. |
| 61 | M & L for point wiring with copper conductor cable multistrand, PVC sheathed 1.5 Sqmm size(two run with colour code RYB) for one light point ,fan point, exhaust fan point,or bell point controlled by one switch including one run of 1.5 Sqmm (as continous earth wire Green)multistrand PVC concealed conduit of approved size and quality ISI marked,including all other required accessories as specified in preamable 1(a) to (q) of section 19 of SSR Part-II under heading 'point wiring' fixedon wall/ceiling including sunk cast iron terminal boxes grouting/flushing on wall for mounting fittings like switch,sockets etc covered with 3.00 mm thick plastic laminated sheet top cover of brick masonary/Stone masonary wall complete including cutting,chasing,pinning and making good the disturbed surface by using cement mortar 1:3 complete all as specified and directed by Engr-in-charge.(Note:-the rate for concealed type point wiring shall deemed to include the cost of cutting,chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plaster and matching the surface by white wash/colour wash all as per existing finishes complete). |
| 62 | All as per Srl item No 61 here in before but for one 5 amps socket outlet on same board. |
| 63 | All as per Srl item No 61 here in before but for one 5 amps socket outlet on independent board. |
| 64 | All as per item No 61 above but for power point 3 pin switch socket 16 Amp with PVC insulated copper conductor cable multistrand unsheathed 4 Sqmm (two run with colour code RYB) on independent board including one run of 4 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in concealed PVC conduit of appropriate size and best quality ISI marked, including all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading \\"Point wiring\\" fixed on wall including sunk cast iron or PVC terminal boxes for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed. |
| 65 | Supply & Fixing in replacement of modular Switch one way 6 Amps,1 module |
| 66 | Supply & Fixing in replacement of modular Socket outlet ,6A 2/3 pin combined 2 module. |
| 67 | Supply & Fixing in replacement of modular Switch one way 16 amps,1 module |
| 68 | Supply & Fixing in replacement of modular Socket outlet 6A/16A -2/3 pin combined 2 module. |
| 69 | Supply and fix in replacement of ceiling rose 65X50 mm two to three terminals complete all as specified. |
| 70 | S & F in replacement of surface/wall mounted batten LED Inverter type luminair 20 watt 4000 K Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate having efficiency 120 lumens/watt ,power factor more than 0.90,IP 20 including making connections with flxible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 71 | Supply and fix in replacement of Decorative wall light fitting with LED BULB 1x 09/10 Watt. make Havells cat part No LHFOAJE1TN1I060 or equivalent of Philips/Bajaj or CG as approved. |
| 72 | Supply and Fixing in replacement of Sheet metal enclosures for TPN DBs when MCBs to be used, triple pole and neutral, 4 way, double door, 415 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified. |
| 73 | Supply and fixing in replacement of MCB triple pole and nuetral 63 Amps, 415 volts complete all as spd and directed. |
| 74 | Supply & Fixing in replacement of Sheet metal enclosure for DB,s, double door (when MCB,s to be used) single pole & neutral 8 way with 200 amps rated bus bar 240 volts with fixing arrangements including taking down ICDP/DB's any type including taking down of kitkat fuse/MCB SPN/SP as directed by Engineer-in-charge. |
| 75 | Supply and fixing in replacement of MCB single pole and nuetral 6 to 32 Amps, 240 volts complete all as spd and directed. |
| 76 | Supply and fixing in replacement of MCB single pole 6 to 32Amps, 240 volts all as spd and directed. |
| 77 | M & L for sub main wiring with 6.0 sqmm copper conductor cable multistrand, FRPVC sheathed two run (as phase and neutral) and run 6.0 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in drawn in one pvc concealed wiring complete all as specified and directed by Engr-in-charge.(Note:-the rate for concealed type point wiring shall deemed to include the cost of cutting,chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plasterand matching the surface by white wash/colour wash all as per existing finishes complete). |
| 78 | Supply and fixing LED Bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver ,lamp bracket with impact and corrosion resistant including thermal management in multiple optice complete with IP 65/66 protection complete all as specified and as directed by Engr -in- charge. |
| 79 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |
| 80 | Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 26 of tender doucments. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 days