| 1 | Taking down carefully existing copper/aluminium point wiring (light/fan/sockets/bell/power point) complete with all accessories such as switch with sheet, ceiling rose including rusted/broken concealed conduit, junction and sunken boxes etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ.) |
| 3 | All as per Item No.2 above here in before but for One three pins 6 Amps switch socket outlet point on independent board with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. |
| 4 | All as per Item No.2 above here in before but for One three pins 6 Amps switch socket outlet point on same board with other switches with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. |
| 5 | All as per Item No.2 above here in before but for One light point controlled by two 2-way switches of 6 amps with other switches with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. |
| 6 | Description all as per item No.2 above here in before but for 16 amps socket outlet with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. |
| 7 | Description all as per item No.2 above here in before but for 16 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. |
| 8 | Supply only modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 9 | Supply only modular switch 5/6Amps, single pole, two way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 10 | Supply only modular Bell Push switch, 5Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 11 | Supply only modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 12 | Supply only modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 13 | Supply only modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 14 | Supply only modular Fan regulator, single pole, one way complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 15 | S & F switch piano one way 5/6 amps 240 volts complete all as specified and directed. |
| 16 | S & F switch piano one way 16 amps 240 volts complete all as specified and directed. |
| 17 | S & F Bell push AC, 50 Hz, 230 Volts, 5 amps complete all as specified. |
| 18 | S & F Bell ding dong AC, 230 Volts, Single pole complete all as specified. |
| 19 | S & F socket 5 in 1, 5 amps flush type complete all as specifeid. |
| 20 | S & F socket 5 in 1, 5/16 amps flush type complete all as specifeid. |
| 21 | S & F switch piano flush type 5 amps but 2 way type complete all as specified. |
| 22 | Supply & fixing PVC Lamp holder suitable for and including batten fittings ,LED Electric lamp 9 Watt with backalite 20mm back plate complete all as specified & directed, . |
| 23 | M & L Ceiling rose, 3 terminals/phase type, fabricated of PVC/Polycarbonate, isolated body complete, |
| 24 | S&F of fan regulator step down electronic type heavy duly flush type 230 volts AC single phase fixed on laminated sheet top cover (laminated top cover is included in point wiring) and connecting up complete all as specified and directed. (Laminated sheet top cover and sunken box is included in point wiring). |
| 25 | M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings/existing concealed conduit complete, including provision of 1 x 10 sqmm nominal cross sectional area multistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire complete incl taking down old UNSV sub main all as specified.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 26 | Description all as per item No.25 above here in before but 2 Runs of 6 sqmm complete in PVC conduits/ complete all as specified. |
| 27 | Description all as per item No.25 above here in before but 2 Runs of 4 sqmm in PVC conduit and its fittings complete all as specified and directed by Engr-In-charge. |
| 28 | Supply, laying, fixing or passing through pipe, 1100 volts grade heavy duty cable of size 2 core 10 sqmm nominal cross section in service connections of PVC insulated aluminium multi standard conductor served with an inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed by Engr-In-charge. |
| 29 | All as per Item No.28 above here-in-before but 2 core 6 sqmm complete all as specified and directed. |
| 30 | S&F sheet metal enclouser VTPN/HTPN DB having facility to fix MCCB incomer upto 125 Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates including making good disturbed surfaces after taking out old unserviceable DB complete all as specified and directed. |
| 31 | Dismantling of existisng unserviceable MCB distribution board and S&F in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ. |
| 32 | Dismantling of existisng unserviceable MCB distribution board and S&F in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ. |
| 33 | S&F Post top lantern Light of not less than 30 Watt capacity made of housing epoxy powder coated pressure die cast aluminium spigot and lid cover with graphite grey finish and clear acrylic cover, IP65 protction with suitable mounting GI pipe upto 1.0m, including PCC 1:2:4 foundation, complete all as specified and directed. |
| 34 | Supply and fixing complete set of 1x10 watt LED retrofit type bulkhead fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge. |
| 35 | Demolishing the earth pit chamber and constructing new earth pit chamber brick work in cm 1:4, plastering cm 1:3 and PCC chamber cover only complete as per SSR Pt-I of 1996 including new wire mesh funnel all as directed |
| 36 | Material and labour for 2mm thick galvanised steel presses sunken box suitable for both paino type fitting and modular switch socket (min 60 mm deep, suitable length) grouted flush to walls and necessary cement work of cm 1:4 and applying putty around 3mm thick switch board to match with existing surface and provision of suitable hylem sheet of 3mm thick (ISI Marked) fitted with Chromium plated brass screws & washers for paino type fittings and for 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc. Fixing existing serviceable modular/paino type switch, socket, regulator for any type of concealed point wiring complete all as specified and directed.Note: 1. Replacing Old unserviceble switch, socket regulator if any with new is measurable in sepearte items |
| 37 | Earthing complete with galvanised steel earth plate electroe 60 cmx60cm6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connectedto and including galvanized earth lead 4mm dia GI earth wire by means of GI bolt/snuts/washers, protected by 40mm bore GI light grade pipe from earth plate & upto 3m long pole fixed with 2 clamp made from mild steel flat iron 32x6mm bolts, nuts, washer etc. earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around buttom and top of earth plate 20mm dia GI Medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame PCC 1:3:6 type C1 using 20mm graded stone aggregate as in earthing pit including necessary excavation & earth work all as specified & shown on electrical plate No. 3 of SSR Part-I, (Note: (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner (ii) earthing for Lightning protection is also included in the above item) |
| 38 | Supply and fixing LED luminaire 600 mm x 600 mm,36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.Make :Bajaj/ Havells/Phillips/Wipro as recommended by Engr-Incharge and approved by GE. |
| 39 | Supply and fixing warm type LED luminaire 600 mm x 600 mm,36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.Make :Bajaj/ Havells/Phillips/Wipro as recommended by Engr-Incharge and approved by GE. |
| 40 | S&F and testing of warm type LED light fitting 1x18watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through h oles. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. |
| 41 | S&F sheet metal enclouser TPN DB having facility to fix MCB TPN upto 100 amp and MCB in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates complete all as specified and directed. |
| 42 | S & F of MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 6 to 32 Amps all as specified and directed. |
| 43 | S & F of MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 40 Amps all as specified and directed. |
| 44 | S& F plug and socket type DB (Functional unit)20 Amps capacity with provision of single pole 20 amps MCB,plug top and earth plug,grouted flush to walls complete all as specified. |
| 45 | Supply and fixing LED light fitting 1 x 8/10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 46 | S&F and testing LED light fitting 1x18watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through h oles. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. |
| 47 | M&L for ceiling light fitting of skylux LED efficient LED surface round type luminaire & galre free soft illumination of capacity 15 watt LED white/warm colour complete suitable for roof ceiling including connecting upto with driver 3 core flexible conductor copper of suitable size complete all asspecified anddirectedby Engrin-charge |
| 48 | M&L for ceiling light fitting of skylux LED efficient LED surface square type luminaire & galre free soft illumination of capacity 15 watt LED white/warm colour complete suitable for roof ceiling including connecting upto with driver 3 core flexible conductor copper of suitable size complete all asspecified anddirectedby Engrin-charge |
| 49 | S&F and testing of warm decorative LED light min 9 watt with glass shade/fabric/wood/ aluminum, brass/metal material l flush mount including wrrm white E27 bulb with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. Total input voltage range 140-280V AC, complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supplying, fixing,testing,& commissioning intergal decorative Water proof 9/10 Watt LED bollard light with opal acrylic with IP-65 protection with inbuilt driver, colour temperature of 5700 K of graphite grey powder coated finish type including PCC base with specified size complete all as specified and directed by Engr-in-Charge. |
| 51 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles/ garden light etc , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. Please Enable Macros to View BoQ information |
| 52 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles/ garden light etc , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. Please Enable Macros to View BoQ information |