Tender For Construction Of Rest Room For Security At Terrace Of Control Room Building At 132/33 Kv Ais Substation Dhar Ur, Distt. Mandi (H.P).
Tender Overview
Project Description
Tender for Construction Of Rest Room For Security At Terrace Of Control Room Building At 132/33 Kv Ais Substation Dhar Ur, Distt. Mandi (H.P).
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Jun-2026 | Corrigendum 1 | Date | 01-Jul-2026 |
| 2 | 02-Jul-2026 | Corrigendum 2 | Date | 08-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | ELECTRICAL WORKS |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 4 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size). |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete Suspended floors, roofs, landings, balconies and access platform. |
| 7 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand). |
| 8 | 20mm Cement plaster in two coats,backing coat 15mm and finishing coat 5mm thick on rough side of brick/stone masonry walls for interior plastering upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth.(ii) Cement Mortar1:4 (1cement:4 sand).20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand). |
| 9 | 15mm cement plaster in two coats backing coat 10mm and finishing coat 5mm thick on fair side of brick masonry/stone masonry/concrete walls for interior plastering upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth. (ii) cement mortar 1:4 (1 Cement:4 Sand). |
| 10 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) |
| 11 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 12 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)ew work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 13 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat withcement primer. |
| 14 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cement20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greyand matching pigments etc., complete. Size of Tile 600x600 mm |
| 15 | Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm , mixing fibre @ 125 grams per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge. |
| 16 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab upto 0.50 sqm |
| 17 | Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). |
| 18 | Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 19 | Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). |
| 20 | Providing and Fixing in wall lining medium density Fibre board IS 14587: 1998 marked prelaminted one side decorative lamination and other side balancing lamination with necessary fixing arrangement with necessary Fixing arrangement and screws etc. complete |
| 21 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 22 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 23 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore |
| 24 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore |
| 25 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia |
| 26 | Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length 15 mm nominal bore |
| 27 | Providing and fixing PTMT grating of approved quality and colour.Circular type 100 mm nominal dia |
| 28 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm |
| 29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes |
| 30 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 31 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 32 | Coupler 110 mm |
| 33 | Single pushfit Coupler 110mm |
| 34 | Bend 110mm |
| 35 | Single tee with door |
| 36 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 37 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 38 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 39 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 40 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 41 | Providing and Fixing PVC floor trap of self ceaning design including fixing with approved adhesive ,cost of cutting and making good the foors etc complete .110mm*75mm |
| 42 | Providing and fixing PVC clamps ISI marked of Approved Design with steel screws and rawal plugs etc complete |
| 43 | Providing and fixing 19mm thick Commercial plyBoard water proof shutters for up boards i/c fixing with nickel plated piano hinges with screws etc complete) |
| 44 | Providing and fixing 19mm thick water proof commercial board in shelves/box for cup board with butt joints & fixing with nails & screws etc complete) |
| 45 | Providing and fixing 1.00mm thick coloured or plain lamination sheet (sunmica) on boards/ply wood sheets with approved adhesive and nails etc complete. |
| 46 | Providing and fixing 50 mm special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. |
| 47 | Providing and fixing square edges cover fillets ( beading) 19 mm X 6 mm section i/c mitring at junctions with wood screws and nails complete |
| 48 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Triple strip vertical type. |
| 49 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 50 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets :20 mm dia (heavy type) |
| 51 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 52 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore |
| 53 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 15mm nominal bore |
| 54 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 200 mm |
| 55 | Float glass panes 5.5 mm thick glass panes. |
| 56 | Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Group A) |
| 57 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 58 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 59 | 2 Module (100mmX75mm) |
| 60 | 4 Module (100mmX75mm) |
| 61 | 6 Module (100mmX75mm) |
| 62 | 8 Module (100mmX75mm) |
| 63 | 12 Module (200mmX150mm) |
| 64 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections etc. as required. |
| 65 | S.P. 5/6 amps, one way modular switch, ISI marked |
| 66 | S.P. 15/16 amps, one way modular switch, ISI marked |
| 67 | 3 pin 5/6 amps modular socket outlet, ISI marked |
| 68 | 6 pin 15/16 amps modular socket outlet, ISI marked |
| 69 | Modular blanking plate (dummy switch) |
| 70 | Providing, and fixing decorative and ceiling mounted 12W LED Type luminaries |
| 71 | Providing, and fixing 20W Basic standard LED Type Lightbulb |
| 72 | Supplying and fixing PVC batten/ angle holder including connection etc. |
| 73 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 74 | 8 way, Single door( 8 POLE) |
| 75 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 76 | 10 A ratings , SP MCB, “C” curve, 10 KA breaking capacity |
| 77 | 16 A ratings , SP MCB, “C” curve, 10 KA breaking capacity |
| 78 | 32 A ratings , DP MCB, “C” curve, 10 KA breaking capacity |
| 79 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 80 | Providing a ceiling fan 1200 mm sweep ISI marked the down rod of standard length (up to 30 cm ) with 1.5 sq. mm PVC insulated copper conductor cable as required.(Preferred make: ORIENT ELECTRIC/BAJAJ/CROMPTON) |
| 81 | Supplying and fixing stepped type modular fan regulator on the existing modular box including making connection as required. |
| 82 | Supplying and fixing of Exhaust Light duty fan 250mm sweep ISI marked in the existing opening |
| 83 | Supplying and fixing of 25 Litre storage water Geyser with the existing power point |
| 84 | Supplying and fixing of 05 Litre storage water Geyser with the existing power point |
| 85 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender