|
| 1 | E/W in excavation in foundation trenches in ordinary soil (vide classification of soil item –A) as per approved design, building specification and direction of E/I BCD 5.1.1 |
| 2 | E/W in excavation in foundation trenches in ordinary soil (vide classification of soil item –A) as per approved design, building specification and direction of E/I BCD 5.1.2 |
| 3 | Provding coarse clean sand in filling foundation and plinth with all complete and as per building specfication and dierection of E/I.BCD 5.1.10 |
| 4 | Providing designation 75-B one brick flat soling joint filled by local sand all complete as per building specification & direction of E.I BCD 5.6.3 |
| 5 | Providing P.C.C. M150 with nominal mix of (1:2:4) in foundation and plinth as per building specification and direction of E/I BCD 5.3.1.2 |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) BCD 5.3.9.1 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) BCD 5.3.10 |
| 8 | Reinforcment Cement Concrete work in beams,lintels,landing,balconies,shelves,chajja, band,staircase above plinth level. excluding shuttering & centering with all complete as per specification & direction of E/I. BCD5.3.11 |
| 9 | Providing dsignation 75-B brick work in cement mortar (1:6) in foundation & plinth with all complete as per bldg. specification and direction of E/I. BCD 5.2.6 |
| 10 | Providing 75 B Brick work in S/S in cement mortar (1:6) with all complete as per bldg. specification & direction of E/I. BCD 5.2.14 |
| 11 | Providing T.M.T. Bars in reinforcement in R.C.C. Work as per approved design and drawing with cutting binding and bending with annealed wire.8mm dia Tor/T.M.T Fe- 500 5.5.4 |
| 12 | Providing T.M.T. Bars in reinforcement in R.C.C. Work as per approved design and drawing with cutting binding and bending with annealed wire.10 mm dia Tor/T.M.T Fe- 500 5.5.5(A) |
| 13 | Providing T.M.T. Bars in reinforcement in R.C.C. Work as per approved design and drawing with cutting binding and bending with annealed wire.12 mm dia and above Tor/T.M.T Fe- 500 5.5.5(B) |
| 14 | Providing 12mm thick cement Plaster in C.M (1:6) with clean coarse sand of F.M. 1.5 including screening curing with all leads and lifts BCD 5.7.3 |
| 15 | Providing 6mm thick cement plaster in ceiling in cement mortar (1:4) with clean coarse sand of F.M. 1.5 including screening curing with all leads and lifts.BCD 5.7.6 |
| 16 | Providing 12 mm thick out side plaster in cement mortar (1:6) with clean coarse sand of F.M. 1.5 including screening curing with all leads and lifts. BCD 5.7.14 |
| 17 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) BCD5.5.12 |
| 18 | Providing and fixing PVC Door Frame of size 50x47mm with thickness of 5mm made out of single piece of extruded PVC profile with mitred cut joints.BCD 9.14.1 |
| 19 | 35mm thick factory made Solid panel PVC Door shutter made out of single piece extruded solid PVC profiles 5mm thick having style & rails all complete job as per specification.BCD 9.142 |
| 20 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .5.6.28 |
| 21 | supplying ,fitting and fixing collapsible gate of approved size and make properly fabricated all complete job as per building specification and direction of E/I 5.5.14 |
| 22 | provinding and fixing pressed window frame...fixing with adjustable lugs with split end tail to each jamb dsr 10.14.1.1 |
| 23 | providing and fixing glazing in aluminium door ,windows ventilators shutters and partition etc glass panel of 5mm thickness dsr21.3.2 |
| 24 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.With commercial grade colour 15 x 15 cm tiles 5.6.23.1 |
| 25 | providing and applying plaster of paris putty of 2mm thickness over plaster surface to prepare the surface even and smooth complete (13.26) DSR |
| 26 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)(13.46.1) |
| 27 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqmover and including one coat of Special primer applied @0.75 ltr /10 sqm 13.48.1 |
| 28 | Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills& railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.5.8.45 |
| 29 | Providing and fixing 40 mm high vitreous white glazed eathen E.W.C with p trap of perry hidustan or any other approved I/S/S make including supplying and fixing 15 litres mosquito proof low down flusing cistern E/I 3.2.2(ii).(a)B.C |
| 30 | Providing and fixing wash basin with C.I. brackets 15mm C.P. brass pillar taps, 32 mm C.P brass waste of standard pattern, including painting of fitting and brackets, cutting and making goods the wall wherever required, white vitreous china flat back wash basin size 550x400mm with single 15mm C.P. brass pillar taps.3.2.5 |
| 31 | C.P. brass bibcock 15mm 3.1.5.1SOR |
| 32 | C.P. brass long body bibcock 15mm DSR 18.51.1 |
| 33 | Providing and fixing (C.P.V.C) having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes pipes G.I. fitting including trenching and refilling etc. Extranal work 25mm nominal bore dsr 18.9.3 |
| 34 | Providing and fixing (C.P.V.C) having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes pipes G.I. fitting including trenching and refilling etc. Extranal work 32 mm nominal bore dsr 18.9.4 |
| 35 | Providing and fixing (C.P.V.C) having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes pipes G.I. fitting including trenching and refilling etc. Extranal work 40mm nominal bore dsr 18.9.5 |
| 36 | Providing and laying factory made chamferededgeCementConcretepaver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory methodusingPUmould, laid inrequired colour & pattern over 50 mm thick compactedbedofsand,compactingand proper bedding/laying of inter locking paverblocksintothesandbeddinglayer through vibratory compactionbyusingplatevibrator, filling the jointswithsandandcuttingofpaver blocksasper requiredsizeandpattern, finishing and sweeping extra sand. completeallasperdirectionofEngineerin-Charge. 80mmthickC.C.paverblockof M-35 grade with approved colour design and pattern.DSR 16.91.2 |
| 37 | Supplying, fitting and fixing 20mm dia M.S. Bar 1 meter long holding down bolt with nuts washers 100 X100 X6mm plate fitted and fixed with cement concrete (1:24) as per approved design all complete as per building specification and direction of E/I.5.5.19 |
| 38 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete DSR 10.20 |
| 39 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-inCharge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.DSR 12.50 |
| 40 | Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (i) 300X300 mm size 5.6.19 |
| 41 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I.5.7.11 |
| 42 | Finishing wall with Premium Acrylic Smooth exterior paint of required shade New work ( two or more coats applied @ 1.67 ltr./10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kgs/ 10 sqm.)13.47.1 DSR |
| 43 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).DSR 10.28 |
| 44 | Earth filling in foundaion trenches and plinthinlayersnotexceding150mmthick well watered, rammed, fully compacted and fine dressed with earth obtained from excavationof foundationtrencheswithina leadof50Mandliftof1.5Mallcomplete asperbuildingspecificationanddirection ofE/I. (modeofmeasurementcompacted volume) 5.1.7 |
| 45 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 40 mm nominal size) BCD. 5.3.1.5 |
| 46 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1.5.3(1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)BCD.5.3.1.1 |
| 47 | Centering and shuttering including strutting, propping etc. and removal of form for foundation footing , base of Column etc. for mass concrete.BCD.5.3.17.1 |
| 48 | Earth work in filling in foundation trenches or back filling of masonry structure with state earth in layer not exceeding 150mm thick well watered rammed and fully compacted and finely dressed with earth obtained from excavation of foundation trenches and kept at a lead of 30m and initial lift 1.5m complete as per specification and direction of E/l.WRD.Part-B 6.1.16 |
| 49 | Columns, Pillars, Piers, Abutments, Posts and Struts 5.3.17.6 |
| 50 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot Finished Welded Type Tubes IS CODE 1161:1998 DSR 10.16 |
| 51 | labour or fitting and fixing G.C.I. or C.A. sheet rooing in proper slope including the cost of 'J' or 'L' hooks,limpet and bitumen washers carriages o sheets to work site and taxes all complete as per building specification and direction o E/I 5.9.10 |
| 52 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges Plain (500-600mm) DSR 12.51.1 |
| 53 | Aggregate 20 mm nominal size at Quarry wrd part b M 0412*3*0.5=3 M3 |
| 54 | Aggregate 40 mm nominal size at Quarry wrd part b M 0412*3*1.0=6.0 M3 |
| 55 | Labour laying for stone Wrd 6.6.1item no 6+7=3+6=9.0 m3 |
| 56 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.DSR 2023 VOL 1, 12.41.2 110 mm diameter Multiple factor - 0.794 |
| 57 | Lintels, beams, plinth beams, girders, bressumers and cantilevers Plinth beam 5.3.17.5 |
| 58 | Making plinth protection 50mmthick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6gradedstoneaggregate20mm nominal size)over75mmthickbedofdry brick ballast 40mmnominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.5.3.8 |
| 59 | Providing 150mm. Wide brick drain in cementmortar(1:6)withav.150mmclear depthand125mmapronincludingcostof eartwork involved with 75mm cement concrete(1:4:3)overonebrickdesignation 75Aflatsolinginpropergradeandslopeat thebasethedraindulyplastered inC.M. (1:3)withpunningoverexposedsurfaceall completeasperbuildingspecificationand direction of E/I.5.10.3 4 |
| 60 | Providing designation 100 A brick work with fly ash lime brick (FLAG) condieminf ro IA - 12894 - 1990 (0'-9'' x 4'-5'' x 0'-3'') in CM (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick motor joint, cost of screening materials rakingout joints 15 mm depth, curring, taxes and royalty all complete as per building specification and direction of E/I (5.2.52) |
| 61 | (iii) Plinth Beam (5.3.17.21) |
| 62 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) 5.3.2.3 |
| 63 | Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I 5.7.2 |
| 64 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.DSR/10.5.1 |
| 65 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all complete as per specification and direction of E/I and Providing primer one coat or red lead paint of approved makeover new steel surface 5.8.41 |
| 66 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all complete as per specification and direction of E/I and Providing primer one coat or red lead paint of approved makeover new steel surface 5.8.43 |
| 67 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent 11.55.1 |
| 68 | Wiring for light/point/fan point/Exhaust fan point/call bell point with 1.5 Sq.mm F.R P.V.C insulated copper conductor cable in surface / recessed P.V.C conduit as required. with piano type switch phenolic laminated sheet M.S Box earthing the point P.V.C insulated copper with 1.5 Sq.mm F.R PVC insulated copper conductor single core cable etc. at required.1.1.3 Group C |
| 69 | Supplying and fixing suitable size GI box/PVC all complete job 1.22.9 :- 210x206x48mm |
| 70 | Supplying and fixing suitable size GI box/PVC all complete job 1.22.8 :- 170x221x48mm |
| 71 | Supplying and fixing suitable size GI box/PVC all complete job 1.22.1 :- 75x75x50mm |
| 72 | Wiring for light/power plug wiring with 2x4 sqmm PVC insulated copper conductor single core cable in surface/ recessed pvc conduit alongwith 1 No. 4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 73 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.1.7.1 2x1.5 sq.mm+ 1x1.5 sq. mm earth wire |
| 74 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.1.7.2 2x2.5 sq. mm +1x2.5 sq. mm earth wire |
| 75 | S/F of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.1.21.2 25 mm |
| 76 | S/F of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.1.21.3 32 mm |
| 77 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.1.22.4 72mmx226mmx48mm deep/(4\\"x10\\") |
| 78 | Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required.1.23.1 5/6 amps switch |
| 79 | Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required. |
| 80 | Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required. |
| 81 | Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required. |
| 82 | Supplying and fixing metal box of 150 mm X 75 mmX 60 mm deep (nominal size) on surface or in recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential building). |
| 83 | Installation of ITC exhaust fan upto 450 mm sweep in the existing opening ,including making the hole to suitable size of the above fan making good the damage,connection ,testing &commissioning etc. as required |
| 84 | supply,installation,testing and commissioning of surface / recess mounting verticle type 415 volts. Pre-wired TPN MCB distribution board of sheet steel , dust procted , dully phosphatized and powder painted, inclusive of 200 amps. Tinned copper bus bar for monting MCB's detachable gland/ Knock out plate and with built in loose wire box and superior make terminal connecters for all in coming and out going circuits, dully prewired wirth adequate size of FR PVC insulated copper conducted up to the terminal connecter/ nuteral link and ready for installation of following ways (but without MCB,s and incomer) as required 2.10.3 4 (8+12)way double door verticle type |
| 85 | Providing and fixing of 300 mm exhaust fan.(C.G, Bajaj an Equivalent) M 775 |
| 86 | P/F of 1x18 w PL-L tube.(Philips, Bajaj Eqv) M-856 |
| 87 | ITC ceiling fan installation 1.44 |
| 88 | Supplying Celling Fan 48'' (1200 mm) M772 |
| 89 | Carriage of Materials :-Cement + Steel |
| 90 | Stone chips |
| 91 | Stone Metal |
| 92 | Bricks |
| 93 | total |
| 94 | GST @18 % |
| 95 | L Cess @ 1% Please Enable Macros to View BoQ information |