| 1 | E/W in excavation in foundation trenches in ordinary soil (vide classification of soil item –A) as per approved design, building specification and direction of E/I BCD 5.1.1 |
| 2 | E/W in excavation in foundation trenches in ordinary soil (vide classification of soil item –A) as per approved design, building specification and direction of E/I BCD 5.1.2 |
| 3 | Provding coarse clean sand in filling foundation and plinth with all complete and as per building specfication and dierection of E/I.BCD 5.1.10 |
| 4 | Providing designation 75-B one brick flat soling joint filled by local sand all complete as per building specification & direction of E.I BCD 5.6.3 |
| 5 | Providing P.C.C. M150 with nominal mix of (1:2:4) in foundation and plinth as per building specification and direction of E/I BCD 5.3.1.2 |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) BCD 5.3.9.1 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) BCD 5.3.10 |
| 8 | Reinforcment Cement Concrete work in beams,lintels,landing,balconies,shelves,chajja, band,staircase above plinth level. excluding shuttering & centering with all complete as per specification & direction of E/I. BCD5.3.11 |
| 9 | Providing dsignation 75-B brick work in cement mortar (1:6) in foundation & plinth with all complete as per bldg. specification and direction of E/I. BCD 5.2.6 |
| 10 | Providing T.M.T. Bars in reinforcement in R.C.C. Work as per approved design and drawing with cutting binding and bending with annealed wire.8mm dia Tor/T.M.T Fe- 500 5.5.4 |
| 11 | Providing T.M.T. Bars in reinforcement in R.C.C. Work as per approved design and drawing with cutting binding and bending with annealed wire.10 mm dia Tor/T.M.T Fe- 500 5.5.5(A) |
| 12 | Providing T.M.T. Bars in reinforcement in R.C.C. Work as per approved design and drawing with cutting binding and bending with annealed wire.12 mm dia and above Tor/T.M.T Fe- 500 5.5.5(B) |
| 13 | Providing 12mm thick cement Plaster in C.M (1:6) with clean coarse sand of F.M. 1.5 including screening curing with all leads and lifts BCD 5.7.3 |
| 14 | Finishing wall with Premium Acrylic Smooth exterior paint of required shade New work ( two or more coats applied @ 1.67 ltr./10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kgs/ 10 sqm.)13.47.1 DSR |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for foundation footing , base of Column etc. for mass concrete.BCD.5.3.17.1 |
| 16 | Earth filling in foundation trenches and plinth - do - do - as per building specification and direction of E/I. (5.1.7) |
| 17 | Columns, Pillars, Piers, Abutments, Posts and Struts 5.3.17.6 |
| 18 | Lintels, beams, plinth beams, girders, bressumers and cantilevers Plinth beam 5.3.17.5 |
| 19 | Providing designation 100 A brick work with fly ash lime brick (FLAG) condieminf ro IA - 12894 - 1990 (0'-9'' x 4'-5'' x 0'-3'') in CM (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick motor joint, cost of screening materials rakingout joints 15 mm depth, curring, taxes and royalty all complete as per building specification and direction of E/I (5.2.52) |
| 20 | (iii) Plinth Beam (5.3.17.21) |
| 21 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) 5.3.2.3 |
| 22 | Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I 5.7.2 |
| 23 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.DSR/10.5.1 |
| 24 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all complete as per specification and direction of E/I and Providing primer one coat or red lead paint of approved makeover new steel surface 5.8.41 + 5.8.43 |
| 25 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent 11.55.1 |
| 26 | Carriage of Materials :-Cement + Steel |
| 27 | Stone chips |
| 28 | Stone Metal |
| 29 | Bricks |
| 30 | total |
| 31 | GST @18 % |
| 32 | L Cess @ 1% Please Enable Macros to View BoQ information |