| 1 | Drilling of 500mm dia bore with Suitable Rig method borehole in alluvial formation clay/graunlar zones cpmpossed n pebble,cobbles in semi rocky with suitable rig including the cost of consumable store fuel,oil & transportation of rig to the site of proposed bore. complete in all respect. Drilling of bore with suitable rig method borehole Upto 200 m depth BGL |
| 2 | Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect. |
| 3 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.200mm nominal diameter (weight 33.6 kg per metre) 6.4 mm thickness |
| 4 | Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell respects.200mm Steel Strainer (slot size 0.75mm) 6.30 mm thickness |
| 5 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.200mm internal diameter. |
| 6 | Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all Respect.200mm internal diameter. |
| 7 | Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect.200mm internal diameter (weight 33.6 kg per metre) 6.30 mm thickness |
| 8 | Supplying and fixing well cap having thread to fix on housing pipe. Complete in all respects.200mm internal diameter. |
| 9 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 10 | Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 11 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments .(to be paid as per actual length of pipe).The rates including loading & unloading charges. |
| 12 | Supplying & fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects.(a) Strainer & MS pipe should be properly jointed with sockets and duly welded to ensure maximum strength of joint.(b) A steel strip of suitable size should be welded across the length of strainer to provide additional strength to the tubewell assembley. |
| 13 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide & Urenium etc.) |
| 14 | Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.Capacity of Air compressor 550 cfm at 600 PSI. |
| 15 | Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 16 | Collection of water sample from different strata and testing of sample from approved laboratory |
| 17 | Supplying at site Tibba sand etc. including pouring and packing in the annular space between the pipes assembly and the bore above clay seal complete in all respect. |
| 18 | Providing & Fixing Sanitery Seal (As per IS:2800-2019) |
| 19 | Provision for Sterilisation of tubewell with sodium hypochorlide/chlorination of well as per IS code 2800: 2019 complete job. The well shall be disinfected or sterilized as per IS code 2800:2019 or latest, after the development by pump and before the final test. All wells regardless of the use should be sterilized on completion to prevent or retard the growth of corrosion or incrustation fostering organisms. This should be done by introducing chlorine into the water in the well and immediate aquifer surrounding the well .The volume of water in the screen and casing should be estimated and sufficient chlorine added to yield for water with chlorination of 1000 ppm. The solution should be poured into the well and thoroughly mixed in the well by surging with pump. The solution should remain in the well for at leaset 6 hours during which it should be surged at about 2 h interval. After expiration of contact time , the well should be pumped initially back into the well for abour 30 minute and late to waste until there is little of no odour or taste of chlorine in the discharged water . IT has been found that using hypochlorite is of 10% concentration, the requirement of hypochlorite is 10 litre for every cubic meter of water in the well to produce. |
| 20 | Providing & Fixing Clay seal in graval pack minimum 3 Mtr. (As per IS: 2800-2019) |
| 21 | Providing, Laying, fixing & jointing of PVC pipes as per ISI-4985 (ISI marked with prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation complete in all respects. 110mm o/d PVC Pipe of 10kg/Sqm2 |
| 22 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge).100 mm I/d |
| 23 | Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete @ 33Kg Each (1x33kg = 33kg) |
| 24 | Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (size 0.9m x 0.9m) |
| 25 | Prov. Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator,suitable for delivering 0.5 to 6 Litres of Bleaching Powder Solution/Sodium Hypo solution per hour under maximum delivery pressure up to 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS. standard specifications. |
| 26 | Providing, installing, testing and commissioning of 1 no. (12.50 BHP) Electrically driven pumping set of reputed make Complete in all respects\\" |
| 27 | Providing and Fixing G.I. Column Pipe of IS 1239-2004 medium class size 80 mm (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts complete in all respects. |
| 28 | Providing and Fixing of PVC insulatedPVC Sheathed (3 core) round flexible wire with copper conductor (FR cable) (ISI marked) confirmed to IS 694-1990 left bare in pipe or casing of suitable size complete in all respects as desired by the Engineer-in-charge - Overall Size 4.0 sqmm (56, 0.3mm), 3 Core |
| 29 | Providing installing, testing and commissioning of 1 no. control panel with closed transition star delta with enclosure consisting of electrical appliances such as contactor, furses, MCCB's over load relays, isolator switches wiring and connnections. Complete in all respect . |
| 30 | Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects |
| 31 | Providing, laying, Jointing and fixing of PVC pipes (4 kg/cm² ISI marked ) as per ISI-4985 (ISI marked with prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications (including specials and excavation) |
| 32 | Any Other Items Please Enable Macros to View BoQ information |