| Sl. No. | Item Description |
| 1 | SCHEDULE A PART-I A (BUILDING WORK) |
| 2 | Construction of 50 Bedded Crises Ward with permanent specifications complete all as specified and shown on drawings. |
| 3 | SCHEDULE A PART-I B (BUILDING WORK) |
| 4 | Providing cement concrete 25 mm thick type B-0 (1:2:4) using 12.5 mm graded agg as in sub base to flooring to receive tilling all as spd and directed by engg-in-charge . |
| 5 | M & L, glazed joint free coloured ceramic tiles in vertical surface as in skirting & dado,450X 300 X 7 to 8 mm thick over and including 10 mm thick rendering in CM1:4 set & jointed in neat cement slurry & pointed in coloured cement to match and including Dismantling of existing floor ,hearth or wall tiling complete all as specified and directed. |
| 6 | M & L, double charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm and not exceeding 1 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colouredcement to match including 15 mm thick screed bed in CM 1:6 as in floor etc set & jointed in neat cement slurry and pointed in coloured cement to match and including Dismantling of existing floor ,hearth or wall tiling complete all as specified and directed |
| 7 | M & L, double charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tilesexceeding 0.42 sqm and not exceeding 1 sqm, in vertical serfaces etc. set and jointed in neat cement slurry and pointed in white or colouredcement to match including 10mm thick rendering in CM 1:4 and including Dismantling of existing floor ,hearth or wall tiling complete all as specified and directed |
| 8 | M & L, non skid joint free coloured ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile not exceeding 0.11 sqm over and including 15 mm thick screed bed in CM 1:6 as in floor etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade, including dismantling tile complete all as specified and directed |
| 9 | M&L Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6. Complete including dismantling of existing floor ,hearth or wall tiling complete all as specified and directedComplete all as specified and directed. |
| 10 | M&L Machine Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl 10 mm thick rendering on brick surface in CM 1:4. Complete including dismantling of existing floor ,hearth or wall tiling ,complete all as specified and directedComplete all as specified and directed. |
| 11 | M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces on wall in CM 1:6 finished the plaster surfaces fair and even complete all as specified and directed. |
| 12 | All as per item no. 2.08 but in cm 1:4 (external surfaces)with water proofing treatment compound. |
| 13 | M&L for 05 mm thick rendering in CM 1:4 on ceiling, soffits, chajja projection etc complete all as specified and directed. |
| 14 | M&L for applying two coat exterior emulsion paint (weather coat of Berger or equivelent ) on newly plastered wall with airless electric sprayers over and incl a coat of primer applied using airless electric sprayers over and incl one coats of wall care putty of 1-1.5mm thickness prepared and sanded with electrically operated sanding machine. application to be done through the authorised applicator of manufacturer complete all as specified and directed.. |
| 15 | M&L for complete removal of existing treatment using mechincal device and applying two coat exterior emulsion paint (weather coat of Berger or equivelent ) on old plastered wall with airless electric sprayers after prepearing old surface applied using airless electric sprayers over and incl one coats of wall care putty of 1-1.5mm thickness prepared and sanded with electrically operated sanding machine. application to be done through the authorised applicator of manufacturer complete all as specified and directed.. |
| 16 | M&L for applying two coat OBD on newly plastered wall with roller application over and incl a coat of primer and one coats of wall care putty of 1-1.5mm thickness prepared and sanded manually. complete all as specified and directed. |
| 17 | M&L for complete removal of existing treatment and applying two coat OBD on existing plastered wall with roller application over a coat of primer and one coats of wall care putty of 1-1.5mm thickness prepared and sanded manually. complete all as specified and directed. |
| 18 | M&L for applying two coat OBD on newly plastered ceilling with roller application over a coat of primer and one coats of wall care putty of 1-1.5mm thickness prepared and sanded manually. complete all as specified and directed. |
| 19 | M&L for complete removal of existing treatment and applying two coat OBD on existing plastered ceilling with roller application over a coat of primer and one coats of wall care putty of 1-1.5mm thickness prepared and sanded manually. complete all as specified and directed. |
| 20 | M&L providing factory made PVC internal door frame (PRELAM ) of size 100 mm x 45 mm with a wall thickness of 5 mm (+- 0.25 mm) made out of extruded 5 mm (+-).25 mm) thick PVC sheet manufactured by an ISO 9001-2008certified company and by joining 3 nos of heat bend PVC sheet section The inside section of size 90 x 30 mm shall be made from plain colour PVC sheet of 5 mm (+- o.25 mm) thickness the inside section will be covered by sticking two sections of size 30 x 35 mm and 70 x 45 mm made from (+-0.25 mm) thick plain PVC sheet The frame shall be mitered cut at two corners and joined with 4 nos of 150 mm longbrackets of 15 mm x 15 mm MS square tube The two vertical door frame are tobe reinforced with 40 mm x 20mm MS square tube of 19 guage through out the frame the door shall be fixed to the wall using anchor fastners A minimum of 4 nos of screw to be provided for each vertical members and min 2 nos for horizontal members etc complete as per manufacturers specification and direction of engineers-in-charge. |
| 21 | M&L in providing 30 mm thick factory made internal PVC flush door shutter wood free consisting of frame made out of MS tube of 19 guage thickness and size 20 mm x 40 mm for stiles as well as top bottom and lock rail MS frame shall have a coat of primer of approved make and manufacturer The inside Panel shall consist of 20 mm thick multichamber hollow PVC section 1 mm thick wall thickness bonded using solvent cement/ cynoacrylate adhesive with 5 mm (+-0.25 mm ) thick plain / prelam PVC sheet manufactured by an ISO 9001-2008 certified company on both side of the inside panel All the four edged lipping to pe painted with PVC ink of matching colour of PLAIN/PRELAM moulded PVC sheet of door 0.20 mm thick (5 mm x 4 mm ) thick PVC sheet to be given for lock provision at lock height door to be fixed with frame with 3 nos SS butt hinges of size 100 mm x 25 mm x 25 mm and 50 mm long steel screw drilled suitable for to pass through both the wall of th MS tube, 2 nos of 150mm long aluminium tower bolt and 2 nos of 100mm aluminium handles other hardwares could be fixed with 25 mm x 8 mm size steel screw etc complete as per direction of engineer in cahrge manufacturer specification and drawings. |
| 22 | S&F 18 mm thick factory made solid PVC flush Kitchen CB shutter /shutter , ,made from co-extruded three layer rigid foam sheet (single extruded process ) with 0.8 to 1mm thick outer face layer having density not less than 1400 kg /cum and density of central core material not less 600 kg/cum , manufactured by an ISO 9001:2015 certified company and fixing in frame at site with and including 03 nos S S hings, 02 Nos S S fancy handle ,02 Nos S S tower bolt, Ball catches with 8mm dai steel ball and brass body and striding plate including letting and inbuilt lockin divice with Key etc for Cup Board / Kitchen cabinets as per specification & drawing complete all as specified and directed Engr-in-charge. |
| 23 | S&F 150mm long floor door stopper of aluminum alloy body and tongue , anodized with hard drawn steel spring complete all as specified and directed |
| 24 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners,Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured or payment purpose.)(A) Area not exceeding 2.50 sqm each. |
| 25 | Supply and fixing factory made uPVC white colour fixed glazed ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 26 | Supply and Fixing sheet glass 5.5mm thick ordinary quality and glazing with oil putty or rubber and aluminium beading in squares n. exc 0.5 sqm in each pane complete all as specified and directed. |
| 27 | Supply and Fixing sound proof, gas filled translucent glass ( 12 mm thick ) and glazing with rubber and aluminium beading in squares exc 0.5 sqm in each pane complete all as specified and directed. |
| 28 | Supply and Fixing sheet glass (frosted or obscured or ground) 5.5mm thick ordinary quality and glazing with oil putty or rubber and aluminium beading in squares n. exc 0.5 sqm in each pane complete all as specified and directed. |
| 29 | M&L for RCC 1:2:4 type B-1using 20mm graded stone aggregate as in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like ,complete all as specified and as directed. |
| 30 | Use and waste of form work to soffit of suspanded slab such as roof slab ,floor slab landing and similar work n exc 200mm thick (horizontally or sloping complete all as specified and as directed. |
| 31 | M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia or securing with clips all as specified. |
| 32 | S&F in repairs bib taps cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed for iron pipe or or brass ferrule for 15 mm bore of pipe. |
| 33 | S&F in repairs 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. |
| 34 | Supply & Fix in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding flushing cistern ) including connection to drain (or outgoing pipe) and to flushing pipe , antisyphonage pipe ,with PVC cover sheet in same colour etc complete all as specified and directed. |
| 35 | S&F in repairs PVC low level 10 lit capacity valveless syphonic action type flushing cistern including 32mm dia PVC flush pipe fixed in repairs complete all as specified and directed |
| 36 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 37 | S&F in repairs Brass chromium plated Tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete. |
| 38 | Supply & Fix 1000 litre capacity rotational moulded polythylene water storage tanks (cylindrical vertical with closed top ) hoisted and fixed in position including dismantling of existing water tanks complete all as specified and directed. |
| 39 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.;and cutting chases for concealed water tubing or concealed conduitwiring, etc. and making good, cutting exceeding 20cm girth |
| 40 | S&F 15 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid in floors, complete complete all as specified and directed |
| 41 | S&F 20 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid in floors, complete all as specified and directed |
| 42 | S&F in repairs 20mm Gate valves with iron wheel head screwed both ends for iron pipe and fixed. |
| 43 | S&F in repairs Oval type Wash Hand Basin (Counter Top) superior quality 550 x 400 mm size fitted and including 15 to 18 mm thick granite top over RCC slab incl waste coupling 150mm long complete all as specified and directed. |
| 44 | S&F in repair, Brass CP wash basin mixer (Long nose Elbow Operated)15mm bore dia for mixing Hot or Cold water screwed down for iron pipe and fixed all as specified and as directed. |
| 45 | S&F in repair, Brass CP wall mixer (long nose)15mm bore dia for mixing Hot or Cold water screwed down for iron pipe and fixed all as specified and as directed. |
| 46 | S & F in repairs SS Soap dish, , approximate size 160x 160x90mm complete all as specified and directed. |
| 47 | S& F in repairs Chromium plated Toilet paper holder with flat recessed type stainless steel .Complete all as specified and directed |
| 48 | S & F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washerscomplete all as specified and directed. |
| 49 | S & F in repairs PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 50 | Supply & Fix in repairs, 75mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors and fixed to wall with PVC holding clamps complete all as specified and directed. |
| 51 | S&F in repairs, 110mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors and vertical surfaces complete all as specified and directed. |
| 52 | S&F in repairs, 75mm bore dia PVC floor trap (SWR) plain with grating including jointing with solvent cement to waste pipe complete all as specified and directed. |
| 53 | S&F in repairs, 75mm bore PVC(SWR) Reducer, TEE, Y, etc complete all as specified and directed. |
| 54 | S&F in repairs, 110mm bore PVC(SWR) bends any radius, complete all as specified and directed. |
| 55 | S&F in repairs, 110mm bore PVC(SWR) Acess door bends any radius, complete all as specified and directed. |
| 56 | S&F in repairs, 110mm bore PVC(SWR) Reducer, TEE, Y, etc complete all as specified and directed. |
| 57 | S&F in repairs, 75mm bore PVC(SWR) vent cowl complete all as specified and directed. |
| 58 | M&L for Granite (Z Black) work (table rubbed and polished) 20mm thick in steps jambs,pillars, window cills, cooking plateform /partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed in CM 1:6 incl moulding, chamfering of edges complete. |
| 59 | S&F TWO BAY SCRUB SINK:S.S. 304, 2 Bay with sensor and foot padel: 2-Bay scrub sink, with infrared photo sensor, digital timer with valve and 2 nos solenoid valves along with manual option made for stainless steel grade 304 polished finished. The scrub sink is provided with front access panel for ease of maintenance and repairs. complete all as specified and directed. |
| 60 | S & F (in repair) 15 mm dia chromium plated angle cocks/stop valves, brass, screwed down, high pressure with crutch or butterfly handle, flench screwed both ends for iron pipe or for union complete all as specified & directed. |
| 61 | M&L for Cutting out concrete blocks, slabs, brickwork or stone masonry (in alternate course), forming tooth-ings for and bonding new work in CM 14: into old work, except materials entering old wall, complete all as specified and directed . |
| 62 | M&L, Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in 1:4 CM complete all as specified and directed . |
| 63 | M & L for water proofing treatment to roofs surfaces including a coat of applied bituminous shalitex primer @ 0.30 lit per sqm evenly on roof surface and a coat of hot bitumen 85/25 @ 1.2 kg/sqm shall be applied on primed surface and laying of 3mm thick APP modified polymeric membrane (weight not less than 3 kg/sqm) unrolled and bonded completly to the substrate with side overlap of 75 mm and end overlap of 100 mm and then sealed/fused by flame or bitumen and a coat of hot blown bitumen grade 85/25 @ 1.2 kg/sqm shall be applied on top of APP modified polymeric membrane as per manufacturer instruction and finally it will be finished with a coat of aluminium paint @ 0.20 kg/sqm ,complete all as specified and as directed . |
| 64 | Supply only Liquid water proofing compound |
| 65 | S&F in repairs curtain rod Min weight 250gm per Rm made of SS pipe dia of rod 25 mm with decorative brackets and ends complete all as specified and as directed. |
| 66 | S&F in repairs Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,hinges, locking arrangements handles all complete as per architectural drawings and the directions of Engineer-in-Charge |
| 67 | S&f Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed |
| 68 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles semi perforated12 mm thick micro tegular edged GRG false ceilling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS false 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross of size 15x 32mm of length 1200 mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items(galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mmto be fixed on periphery wall I partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws.The work shall be carried out as per specifications, drawing and as per directions of the Engineer-inCharge. |
| 69 | S&F Framed work as in doors or gates Fe 410 -W (Gde E- 250) quality A of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 70 | S&F Steel rolling shutters,(1.25mm thick) with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull ormanual type |
| 71 | S&F PANELLING: G.I. with PUFF 50mm thick_WallThe pre-fabricated modular construction is designed and constructed for exact size of field and future diassembly, enlargement, or relocation. The Pre- fabricated Operating Room will be a freestanding structure, constructed from composite, free standing insulated steel wall panels. These panels are produced in a double band laminator, in which two continously moving belts of 120 GSM galvainized sheets of 0.8 mm are firmly bonded together by the sprayed -in insulating foam, which hardens during this process. The core has consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3. |
| 72 | S&F PANELLING: G.I. with PUFF 30 mm thick_CeilingThe pre-fabricated modular construction is designed and constructed for exact size of field and future diassembly, enlargement, or relocation. The Pre- fabricated Operating Room will be a freestanding structure, constructed from composite, free standing insulated steel wall panels. These panels are produced in a double band laminator, in which two continously moving belts of 120 GSM galvalnized sheets of 0.8 mm are firmly bonded together by the sprayed -in insulating foam, which hardens during this process. The core has consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3. |
| 73 | S&F for Filling of all Joints and Cavities with Metallic Epoxy filler and sanded flush to provide a jointless finish and then coat of paint is applied on the surface of wall with the help of roller with a water based liquid plastic aseptic and self- sterilizing wall coating system. |
| 74 | S&F FLOORING TILE/ROLL:Flooring seamless with perfectly curved flash-covings, resistance to mechanical stress and dynamic loads and having ESD/EMI (conductive) protection characteristics, 2mm thick, washable vinyl. (INCLUDING SELF LEVELLING) |
| 75 | S&F Storage G.I. of size 850 x 1666 x 350mm With Tufphon Glass DoorThe storage unit should be made with minimum 1.2 mm thick of Gl. The shelves should be of toughened glass with 2 or more. 25mm dia holes on each shelf for air circulation inside the Storage unit and removable for cleaning The storage unit should be divided 2 or more parts and each part should have individual glass doors. Each glass door shall be with 6mm dia 2 or more holes on each halve of storage unit. Storage unit shall be with high quality locking system.The overall size should be approx. 850mm X 1666mm X 350mm Should be flush mounted/built-in to MOT panel with same finish. |
| 76 | S&F PRESSURE RELIEF DAMPER (SLEEVES & GRILLS)Cascade Pressure Stabilizer having multi 304 graded stainless steel blades to control room air pressure. |
| 77 | S&F Automatic Hermatically Sealed Door |
| 78 | Providing, Fixing, Supply, Installation and Commissioning of Automatic Hermetically sealed Sliding Doors with the following Specification of Size 1500mm X 2100mm• Automatic Hermetically Sealing Sliding Doors having finished surface in high pressure laminate/3 mm pre painted aluminium sheet/SS 304 mm + Sheet/8 mm toughen glass pained on both sides with vision panels of 300 X 300 mm. For smooth sliding the door moves on nylon wheels within a single piece aluminium extruded track. (i) The controller should be capable of being operated by Hand sensor/foot switches. (ii) The track should be of stainless/aluminium and the running surface for the top rollers should be suitable angled to reduce resistance to movement (iii) The door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provide under the stainless steel track to enable smooth and noiseless movement (iv) Opening and closing of the door should be microprocessor controlled electromechanical movement (v) The door material should be high quality and should match the interior and care should be taken to make the leaf strong and light weight. (vi) One should be able to open and close the door effortlessly in case of failure of automatic mechanism/power.(vii) Door opening handle should be strong and study. Material should be of SS/Aluminium.(viii) Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic selling (to maintain air pressure differential). Air tightness 99.99% at a pressure of 100KPa. (ix)The finished for on the either side of the door should be perfectly level (maximum permissible difference +1mm) (x)The overall thickness of the finished door should be 55 to 60mm. The inner part of the door should be filled with CFC free polyurethane foam thickness of 48mm or nearby. (Sealed airtight to prevent further ingress of any microbial organism). (xi) The door and control should comply with IEE regulation and BS 7971 standardization. All motors used should be DC brushless motors with essential; isolation from mains. (xii) Noise level should not exceed 60 db. (xiii) The starting time after receiving the signal should be adjustable between 0.5 to 20 seconds. (xiv) Door should provide X-ray protection (For cath lab only) as per AFRB regulation (Lead equivalent at 100 KV is 0.27mm) (xv) The complete door assembly should be CE marked. (xvi) est certificate for hermetically sealed frame (factory test certificate) should be enclosed with the pre dispatched documents. |
| 79 | All as per item 2.75 above but of size 1000mm X 2100mm. Complete all as specified and directed. |
| 80 | M & L for brick work with sub class B bricks old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer- In- charge. |
| 81 | M & L for cement concrete 1:3:6 type C-2 for 150 mm dia in concrete bed to drain pipes including packing under and haunching against the sides of pipes etc complete all as specified and directed by Engineer-In- Charge |
| 82 | M & L for reinforced concrete pipes,150mm dia class NP-2 laid and jointed complete with collars complete all as specified and directed by Engineer-In- Charge. |
| 83 | Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150mm dia pipes complete all as specified and directed by Engineer-In- Charge. |
| 84 | M & L for providing precast RCC 1:2:4 type B-1 using 20mm graded stone agg as in cover slab and manhole cover etc. complete all as specified and directed by Engineer-In- Charge. |
| 85 | SCHEDULE A PART-I C (RAMP BLDG WORK) |
| 86 | M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed by Engr-In- Charge. |
| 87 | M&L RCC M-30 (Design Mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed |
| 88 | M&L RCC M-30 (Design Mix) as in Columns, pillars, piers, posts and struts complete all as specified and as directed |
| 89 | M&L RCC M-30 (Design Mix) Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed |
| 90 | M&L RCC M-30 (Design Mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed |
| 91 | M&L for formwork (rough finished surface) to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter for rough finished surface |
| 92 | M&L for formwork (rough finished syrface) to sides of pillars, posts, struts, piers, columns and stanchions square/rectangular for rough finished surface |
| 93 | M&L Formwork (rough finished surface) to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, antilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 94 | M&L Formwork (rough finished surface) to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 95 | M&L for Formwork (rough finished surface) to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide |
| 96 | Ditto item no. 3.10 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 97 | M&L precast cement concrete Block Masonary with solid blocks type C1 1:3:6 20mm graded stone aggregate exc 10 cm in width, 25 cm in depth, 15cm in height and setting in mortar 1:6 . |
| 98 | M&L for 15mm thick rendering in cement mortar 1:6 to on brick masonary wall surfaces or on other than fair faces of brick masonary finished even and fair without using extra cement, complete all as specified and directed. |
| 99 | M&L for 15mm thick rendering on fair faces of brick/ concrete surfaces in CM 1:4 finished even and fair. Complete all as specified and directed. |
| 100 | M&L for rendering 5mm thick on fair faces of brick work or concrete surfaces. Complete all as specified and directed. |
| 101 | M&L for 40 mm thick Cement concrete flooring type B-1, 1:2:4 (20mm graded aggregate) finished even and smooth without using extra cement.Complete all as specified and directed. |
| 102 | Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green . Complete all as specified |
| 103 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 104 | Welded steel wire fabric (exc 4.00 Kg) supplied and fixed complete to wood or steel members |
| 105 | M&L for preparing new plastered surfaces of walls and applying two coats of Oil bound distemper on walls over a coat of primer, complete all as specified. |
| 106 | M&L for preparing new plastered ceiling surfaces and applying two coats of Oil bound distemper over a coat of primer, complete all as specified. |
| 107 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Complete all as specified and directed. |
| 108 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer incl preparation of new steel surface complete. |
| 109 | M & L PCC 1:2:4 type B-2 using 20mm graded stone agg as in foundation, posts filling and mass concrete complete all as specified and directed. |
| 110 | S& F steel work in tubular truses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 Grade St-240 |
| 111 | S & F MS joist channel (Fe410-W Gde E-250 quality A), angle or Toe section MS Tubes, Flat square bars etc. fixed independly or framed or without connecting plates, trusses etc any type framming including purlins and rafters etc conforming to Grade Fe 410-0 or Fe 310-0 complete all as specified adn directed by Engr- in- charge. |
| 112 | M&L plates (plain or chequered) channels Fe410 W (Gd E250) qualilty B square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified adn directed |
| 113 | S&F prepainted galvanised aluminium zinc coated GI base corrugated steel sheet 0.50mm thk of any colour having tensile strength of 550MPA as in roof covering/ cladding to wall, fixed with shelf tapping screws as specifeid |
| 114 | S&F prepainted galvanised aluminium zinc coated GI base Plain steel sheet 0.50mm thk for ridge cover of any colour as directed by GE having tensile strength of 550MPA as in roof covering/ cladding to wall, fixed with shelf tapping screws complete all as specified adn directed by Engr- in- charge. |
| 115 | M&L for hardcore (broken stone or boulders) of gauge n exc. 63 mm all as specified and directed. |
| 116 | M&L PCC D-2 1:4:8, 75mm thick (40mm Graded agg) in floor sub base |
| 117 | S&F Mild steel angles, tees, flats, C - section, MS Square Bars, MS Tubes etc as in steel gates, steel posts and struts in fencing, grills, railing etc including embending in concrete and screwing etc including cut to shape as directed drilling holes, noching for wire etc including all nesessary driling, bolting, welding or reveting and similar work comforming Fe290 Gd E165 complete all specified and directed by Engr- in- charge. |
| 118 | SCHEDULE A PART-II (DEMOLITION WORKS) |
| 119 | Demolition for Brickwork or stone/ boulder masonry/ Pcc block walling built in Cement Mortar complete all as specified and directed. |
| 120 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided for complete all as specified and as directed |
| 121 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for. |
| 122 | Taking down old cement plaster any description on brick or stone wall/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete as specified and directed. |
| 123 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm but n.exc 4 Sqm each complete all as specified and directed. |
| 124 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) n.exc 1.5 Sqm each complete all as specified and directed. |
| 125 | Demolition of cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided for complete all as specified and as directed |
| 126 | Taking up or down 15 mm steel tubing and connections complete all as specified and directed. |
| 127 | Taking up or down 20 mm steel tubing and connections complete all as specified and directed. |
| 128 | Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 129 | Taking down existing un-serviceable water proofing treatment from roof slab and cleaning the roof slab by wire brush up to mother slab and removing WPT felt exc 500 mtr but not exc 1.50 Km etc complete all as specified and as directed |
| 130 | Dismantling of old Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, any type including cover fillets |
| 131 | SCHEDULE A PART-III (RETAINING WALL) for details refer pdf folder |
| 132 | SCHEDULE A PART IV ( SITE CLEARANCE & EARTH WORK ) for details refer pdf folder |
| 133 | SCHEDULE A PART V ( ROAD PATH AND CULVERT ) For details refer pdf folder |
| 134 | SCHEDULE A PART VI- (SEWAGE DISPOSAL) for details refer pdf folder |
| 135 | SCHEDULE A PART VII ( AREA DRAINAGE ) for details refer pdf folder |
| 136 | SCHEDULE A PART VIII (COMPOUND WALL AND GATE) for details refer pdf folder |
| 137 | SCHEDULE A PART IX - A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder |
| 138 | SCHEDULE A PART IX - B (EXTERNAL ELECTRIC SUPPLY) |
| 139 | Supply, installing, commissioning & testing Energy Efficient type (Level-III) transformer step down 11/0.433 KV as per IS 1180-2014 Level-2), copper wound outdoor type AC, 3ph, 4 wire 50 Hz filtered & Dehydratd tranformer oil and standard fittings/acccesories of capacity 160 KVA naturally cooled with external cooling tubes, core type delta connected on primary (HV side) and star connected on secondary (LV side) having taping + 2.5, 5, 7.5% to be varied by a manually operated off load tap changing gear including first filling of oil, all fitting and accessories and mounting all as specified. The transformer shall have HT bushing on high voltage side and LT bushing and LT cable end box on low voltage side with neutral brough out side for earth connection and installed on PCC plat form as per manufacturer recommanded and all as specified and directed. |
| 140 | M&L for construction of plateform of size 2500 x 2500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primer complete all as specified. |
| 141 | Supply and fixing Pin type porcelain insulator, vitorous white/brown, including one GI spindle with GI Nut, bolt and washers, 150 hight, 150 dia for HT 11 KV all as specified and directed. |
| 142 | Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 65 protection made out of CRCA sheet 3.15 mm thick powder coated with seven tank process, fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with Copper bus bar capacity 400 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- |
| 143 | INCOMING :- (a) 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 01 Nos (Incoming)OUTGOING :- (b) 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 01 Nos (Out going for Crisis Ward) & Spare MCCB space for future load.(c) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA with Thermal megnatic relay adjustable type – 02 Nos (d) Supply and fix 4 Pole MCCB 32/40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA with Thermal megnatic relay adjustable type – 02 Nos (e) Digital Voltmeter with built in selector switch 0-500Volts -1No(f) Digital Ammeter with built in selector switch 0-200 amps with suitable CTs -1 No(g) LED Indicated Lamp (R,Y,B) one Set-01Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate.(ii) Internal power and control wiring with suitable size PVC insulated multistranded copper wire. |
| 144 | Supply and laying of Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75 for cable protection cover of size 230mm x 115mm x 75mm laid across the cable (i.e width of brick along the length of cable) for cable protection all as specified and directed. |
| 145 | M & L Cable route indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 50 x 6 mm, welded/riveted on back side of plate, fixed and grounted in position with PCC type C-1, block of suitable size complete. |
| 146 | Supply and install Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long). Note - Excavation, PCC for foundation shall be measured and paid separately under respective item. |
| 147 | Supply and install Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long). Note - Excavation, PCC for foundation shall be measured and paid separately under respective item. |
| 148 | Material and Labour for anti-climbing device, spikes type fabricated out of MS bars (round/square and flate inculading nuts, bolts, washers and welding in to halves made to shape to suit the cross sections of the pole. |
| 149 | Supply and fixing Junction box with aluminium bus bar suitable for 3 phase & Neutral , 4 wire of capacity 32 Amps and MCB 0.5 to 1 amps SPN complete with fixing clamps etc. |
| 150 | Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 3x1.5 Sqmm 1100 Volt , drawn through LT steel tubular poles for connection to street light from junction box as directed by Engr- in- Charge. |
| 151 | Bed Head Panel of 4 Feet LengthElectrical 6 Sw.Soc. Body : 6063 T6 , Extruded Aluminium Alloy Profile (ISO AlMg0.5Si). T = Not less than 2mm, Finish : Epoxy coated to RAL 7035 (Textured), End Cover : ABS Symmetrical in design for aesthetics, Overall dimensions (in mm): 1200 Medio (L × W × H) 1215 × 175 × 85, Type : Horizontal - Surface mountable, Certifications : CDSCO License No. ISO 9001:2015 - Quality Management Systems -MFG/MD/2023/000469, Make - Aktiv/HISPL |
| 152 | Supply, install and commissioning Servo Controlled Voltage stabilizer for automatic operation (Confirming as per BIS: 9815 : Part 1 : 1994 Reaffirmed 2019), three phase, 50 Hz, naturally oil cooled, indoor type, copper wound, digital display type, rfelay relay free smooth adn silent operation wtih 1st filling of transformer oil (IS 335 : 2018) & esigned for input variation between 300 V to 460 V with output voltage stabilized at 415V with accuracy ± 2.5% (Adjustable), class of Insulation A, No load losses less than 0.5%, full load losses less than 2.5%, duty cycle - continuous 24 x 7, Efficiency more than 95%, Digital display Voltmeter/Ammeter and speed of correction 6/8 Volts per second with over load and short circuit protection, high /low voltage cut off, single phase sequence change protection and by pass arrasngements and of capacity 150 KVA all as specified and directed. |
| 153 | Supply, installing, commissioning & testing Energy Efficient type transformer step down 11/0.433 KV as per IS 1180-2014 Level-3), copper wound outdoor type AC, 3ph, 4 wire 50 Hz filtered & Dehydratd tranformer oil and standard fittings/acccesories of capacity 250 KVA naturally cooled with external cooling tubes, core type delta connected on primary (HV side) and star connected on secondary (LV side) having taping + 2.5, 5, 7.5% to be varied by a manually operated off load tap changing gear including first filling of oil, all fitting and accessories and mounting all as specified. The transformer shall have HT bushing on high voltage side and LT bushing and LT cable end box on low voltage side with neutral brough out side for earth connection and installed on PCC plat form as per manufacturer recommanded and all as specified and directed. |
| 154 | Supply, installing, erecting, commissioning and testing new factory made LT panel board, 415 Volts, 3 Phase & 4wire system, cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with bakelite sheet between bus bar & cable alley with front side shutters with locking arrangement, including TPN Aluminium bus bar insulated with colour coaded heat shrinkable sleeve of rating not less then 1.5 times the rated capacity of the incomer MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh to the back side of cable alley for the protection purpose . All type Test Certificates and Design varification with switch geares (MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job. The TPN bus bar shall be mounted on F class insulators with intervals not more then 500 mm. All interconnections between the main bus bar as well as incoming/outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less then 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 2.5 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm properly welded with 45 CM long 04 legs of angle iron 50x50x6 mm using 3.15 mm thick CRCA sheet corners to all legs and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of Aluminum lugs and suitable size of chrome plated brass double compression glands provided for incoming and out-going cables comprising the following :- Make of ACB/ MCCB/MCB/Change over switch: L&T/ABB/LEGRAND/SCHNIEDER/SIEMENS |
| 155 | INCOMING :- (a) Supply and fix 4 Pole MCCB 500 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 01 Nos (Incoming)OUTGOING :- (b) Supply and fix 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 03 Nos (Out going for Compressue unit 1 & 2 and 01 Spare).(c) Supply and fix 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 01 No (Out going for OT building load).(d) Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA with Thermal megnatic relay adjustable type – 01 Nos (future load)(e) Digital Multimeter with built in selector switch -1No(f) ED Indicated Lamp (R,Y,B) one Set-01Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate.(ii) Internal power and control wiring with suitable size PVC insulated multistranded copper wire. |
| 156 | Supply and fix Industrial UPS of capacity 10 KVA three phase AC with backup 30-60 minutes on full load and on 50% load respecitvely, input 300 to 450V and out put 415 V ± 1%, inbuilt Isolation Transformer, Battery Interlink connections, battery Capacity 9984 VAH, with battery rack of 32 Nos 12V-26AH Batteries, with provison of interlink connection for 10 KVA UPS - 384 VDC including necesary connection with suitable size of PVC insulated branded copper conduction cable for connection to electrical distribution board all as specified and directed. |
| 157 | Supply laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade of size 400 Sqmm 3.5 core all as specified and directed. Note :- Earth Work, sand cushioning, brick covering, light Grade GI tubing shall be measured and paid separately under respective item. |
| 158 | Supply laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade of size 185 Sqmm 3.5 core all as specified and directed. Note :- Earth Work, sand cushioning, brick covering, light Grade GI tubing shall be measured and paid separately under respective item. |
| 159 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm all as specified and directed. Note :- Earth Work, sand cushioning, brick covering, light Grade GI tubing shall be measured and paid separately under respective item. |
| 160 | Supply and fix cable jointing kit for 11 KV grade cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core 95 sqmm all as specified and directed. |
| 161 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core 95 sqmm all as specified and directed. |
| 162 | Supply laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade of size 240 Sqmm 3.5 core all as specified and directed. Note :- Earth Work, sand cushioning, brick covering, light Grade GI tubing shall be measured and paid separately under respective item. |
| 163 | Supply laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade of size 16 Sqmm 2 core all as specified and directed. Note :- Earth Work, sand cushioning, brick covering, light Grade GI tubing shall be measured and paid separately under respective item. |
| 164 | Supply laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade of size 185 Sqmm 3.5 core all as specified and directed. Note :- Earth Work, sand cushioning, brick covering, light Grade GI tubing shall be measured and paid separately under respective item. |
| 165 | M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge. |
| 166 | Ditto as per srl item no 12.27above but with GI earth lead wire of 4mm dia as earth conductor and protection pipe of 15 mm dia for earthing of poles and lightening arrester incl connection with the equipment all as specified and directed. |
| 167 | SCHEDULE A PART X -A (EXTERNAL WATER SUPPLY) for details refer pdf folder |
| 168 | SCHEDULE A PART X - B (EXTERNAL WATER SUPPLY) |
| 169 | Material and labour for Cutting cast iron pipes in position for insertion of new tees, branches, etc.(inclusive of earth work, CI specials, tpt and labour charges etc) as specified and directed. |
| 170 | Material and labour for construction of Valve pit mesonery of size (internal) 950x950x950mm with PCC 1:3:6 type C1 using brick masonry in CM 1:6 with PCC 1:3:6 type C2 using graded stone aggregate in foundation, PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in flooring bed & copping and applying 15 mm thick cement plaster in cement motar 1:4 mixed with water proofing compound as per manufacturers instruction on the inside of valve pit & valve pit cover made out of 3mm thick mild steel sheet with 40x40x5 mm angle iron frame and 40x5 mm mild steel hold fast embedded in PCC including two coats synthetic enamel paint blue over a coat of red oxide primer etc all as specified and directed. |
| 171 | SCHEDULE A PART XI (AIR CONDITIONING AND REFRIGERATION) |
| 172 | 1. Supply and fix air cooled hi wall split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated for cooling and heating type split Air Conditioner outdoor and indoor complete with cordless remote control unit, Copper Condenser Coils, performs even at ambient temperature of 0°C to 52°C with 4 way air swing, operation range within 140-280 Volt,Hidden LED Display, noise level IDU-40(DB), Anti-Viral + PM 2.5 Air Filter, 10m long air throw, Turbo Cool, Installation Check, Auto Restart on power restoration, Rotary Compressor. equipped with R410A refrigerant with Dry Mode (Dehumidification), Heat Mode, Super Cool features. Offers with One Touch Silent Fan speed, inverter Compressor all as specified and directed. |
| 173 | 2. Supply and fix Refrigerator, Single Phase, electric driven, 230 Volt, sinsitu puf insulation, cfc free refrigerant, having energy efficient hermitically sealed reciprocating type compressor,Capacity 190 Litres, BEE 5 Star rating, with energy efficient, less noise long-lasting performance Compressor, Toughened Glass shelves, anti-bacterial gasket, with lock & key arrangement, intellisense inverter technology 12 Hrs of cooling retention, Insulated Capillary technology all as specified and directed. |
| 174 | 3. Supply and fix Water Cooler electric driven (Single Phase) 230 Volt, sinsitu puf insulation, cfc free refrigerant, having energy efficient hermitically sealed reciprocating type compressor, RO & UV purifier, having approx storage capacity 80 Liter and nominal cooling capacity of 40 liters per hour, BEE 5 Star rated, Dual Tap Dispensing with 2 cold water taps, optimized cooling technology, powered by R134a refrigerant and energy-efficient cooling while maintaining consitent water temperature, stainless steel rust resistant body, food grade tank delivers pure, contaminant free water, extra large stainless steel water tray with rapid drainage all as specified and directed. |
| 175 | 4. Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp all as specified and directed. |
| 176 | 5. Supply and fix voltage stabilizer for outomatic operation, single phase nautrally air cooled indoor type & designed for input variation between 170V to 250V with output stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA all as specified and directed. |
| 177 | 6. Supply and fix voltage stabilizer for outomatic operation, single phase nautrally air cooled indoor type & designed for input variation between 170V to 250V with output stabilized at 230V with accuracy of + 2.5% and of capacity 3 KVA all as specified and directed. |
| 178 | Supply Installation,Testing and commissioning of 100% Inverter VRF Modular units complete with Inverter Scroll compressor fitted with Conentrated winding, air cooled condenser with low noise fan having interconnected control wiring and refrigerant piping housed in compact housing duly powder coated, Conformal Coating on PCB, Hydrophilic Blue Fins, Twin Accumulator & Two Compressors in each Outdoor Unit. from & Above 18HP. All units are Cooling & Heating both with Eco Friendly Refrigerant (R-410a). Unit should deliver 100% capacity without deration upto 42°C Ambient Temperature.Operating Outdoor Ambient Temperature Range Cooling 10°C to 56°C & for Heating -10°C to 24°C.IPLV should be more than 6.7. VRF Installation work to be execute by OEM or OEM Authorised Vendor Only. All Drawings & Heat Load should be Vetted through OEM only. Make: O-General, Mitsubishi, Bluestar |
| 179 | 12 HP |
| 180 | 12HP (For standby for all 3 OT's) |
| 181 | Supply installation,testing and commissioning of Ductable Units with evaporator coil,fan and Fan motor, with corded remote control and necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required.The units shall be of following capacities. Make: O-General, Mitsubishi, Bluestar |
| 182 | 3Tr (1200CFM) |
| 183 | 4Tr (1600CFM) |
| 184 | Supply installation,testing and commissioning of Cassette Units with evaporator coil,fan and Fan motor, inbuilt Drain pump with corded remote control and necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required.The units shall be of following capacities. Make: O-General, Mitsubishi, Bluestar |
| 185 | 1.7Tr (650CFM) |
| 186 | 2.0Tr (695CFM) |
| 187 | 2.8Tr (945CFM) |
| 188 | Supply, Installation, testing and commissioning of (Air Handling Unit) Floor Mounted type, ‘EUROVENT CERTIFIED’ / 'AHRI Certified' 50 mm thick double skin Casing consist of Outer Skin of 0.6mm Pre Coated GI, Inner Skin of 0.6mm Plain SS-304, Frame work consist of Thermal Break Aluminium profile with thermal barrier, insulated panels of Thickness 45mm CFC Free PUF injected (Density: 40 kg / Cu. m.), Drain tray material consist of 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation, GSS Base Channel, with Mixing Chamber. Coil Casing / Blank offs SS-304, Include AHU Control Panel with VFD, with AHU Kit & Controllers(Include Remotes) Coil section with 6 row deep DX cooling coil, For Supply: With Copper tube(IGT):-Tube Dia 9.52 mm / 3/8” O.D, Thickness of Tube 0.5mm,Fins Thickness of 0.15mm of Plain Aluminium Fins, Copper with hydrophilic coating 11 to 13 Nos.Per Inch. Fine Fiter Section - EU-7 Rigid media type filter section require after fan section.Filter Section - Pre (Eu-4) & Hepa filter ( EU-13) with rigid media filter require for return air. Motor - EC Fan motor. UVGI Lamp, CO2 Sensor. |
| 189 | Total Refrigerant gas flow pressure drop including distributor - Max. 4 psig(Coil to be selected at below parameter:-a. 7.2°C Evaporative Temp, b. 54°C Condensing Temp, c. 4° C Superheat, d. 5°C Subcoolinge. Fluid Pressure Drop not more than 35 Pascal)DISTRIBUTORS SHOULD BE IN VERTICAL POSITIONSupply Air , Return and Fresh Air Damper require in AL construction with motorised Acuator. SS piping system for Pan type humdifier from humidifer to AHU section will install after the heater section ( Rate of Humdifier to be quoted separately) in respective item. Heater Section: GI strip heater in 3 bank construction is require as per below capacity with connected heater operating panel in Stap with sensor , contactors and relays. Make: Zeco, Edgetech, Systemair, Flakt |
| 190 | 5Tr (14200 CFM)125m Static Pressure, with Heater 2.0Kw~2.5Kw (With AHU Kit+Remote+AHU Control Panel) |
| 191 | 5Tr (2200 CFM) 125mm Static Pressure, with Heater 2.0Kw~2.5Kw (With AHU Kit+Remote+AHU Control Panel) |
| 192 | 6.5Tr (2400 CFM) 125mm Static Pressure, with Heater 3.0Kw~3.5Kw (With AHU Kit+Remote+AHU Control Panel) |
| 193 | 13Tr (4600 CFM) 125mm Static Pressure, with Heater 5KW~6Kw (Double Coil 1W & 1 Standby) (With AHU Kit+Remote+AHU Control Panel) |
| 194 | 14Tr (5200 CFM) 125mm Static Pressure, with Heater 5KW~6Kw (Double Coil 1W & 1 Standby) (With AHU Kit+Remote+AHU Control Panel) |
| 195 | Supply, Installation, testing and commissioning of (Air Handling Unit) Floor Mounted (TFA) type, ‘EUROVENT CERTIFIED’ / 'AHRI Certified' 40 mm thick double skin Casing consist of Outer Skin of 0.6mm Pre Coated GI, Inner Skin of 0.6mm Plain SS-304, Frame work consist of Thermal Break Aluminium profile with thermal barrier, insulated panels of Thickness 40mm CFC Free PUF injected (Density: 40 kg / Cu. m.), Drain tray material consist of 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation, GSS Base Channel, Coil Casing / Blank offs SS-304, Include AHU Control Panel with VFD, with AHU Kit & Controllers(Include Remotes) Coil section with 8 Row deep DX cooling coil, For Supply: Fan section with DIDW centrifugal backward curved fan,With Copper tube(IGT):-Tube Dia 9.52 mm / 3/8” O.D, Thickness of Tube 0.5mm,Fins Thickness of 0.15mm of Plain Aluminium Fins, Copper with hydrophilic coating 11 to 13 Nos.Per Inch. Filter Section -0.3 Micron Pre Filter . Motor - EC Fan motor. UVGI Lamp, CO2 Sensor.Total Refrigerant gas flow pressure drop including distributor - Max. 4 psigDISTRIBUTORS SHOULD BE IN VERTICAL POSITIONFresh Air Damper require in AL construction with motorised Acuator And Return Fan to Exhaust Air of Same capcacity Air flow as Supply air.Make: Zeco, Edgetech, Systemair, Flakt |
| 196 | 9Tr (2500 CFM) 50mm Static Pressure |
| 197 | S & F refrigerant Y-Joint for Combining Outdoor and Indoor Units required for distribution of refrigerant in copper piping as per final approved drawing which will be submitted by OEM.Make: O-General, Mitsubishi, Bluestar |
| 198 | Supply, installation, testing and commissioning high pressure interconnecting refrigerant pipe of following sizes including civil work like wall opening for copper and drain pipe for VRF system with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications. All Piping intall on cable trays(As per Sch Item 13) with cover for outdoor locations as per OEM recommendations and PVC sleeves shall be provided wherever pipe is crossing the wall. Food grade nitrogen shall be used while making brazing joints complete all as specified and directed. Make:Mandev, Maxflow, Rajco |
| 199 | 9.5 mm with 13 mm thick insulation |
| 200 | 12.7 mm with 13 mm thick insulation |
| 201 | 15.9 mm with 13 mm thick insulation |
| 202 | 19.1 mm with 13 mm thick insulation |
| 203 | 22.2 mm with 19 mm thick insulation |
| 204 | 28.6 mm with 19mm thick insulation |
| 205 | 34.9 mm with 19mm thick insulation |
| 206 | 41.3 mm with 19mm thick insulation |
| 207 | Supply and fixing in position the 32mm dia of PVC (UPVC quality) pipes, cut in required lengths and joined with PVC cement and also providing and fixing in position the necessary \\"U\\" trap elbows, tees, and reducer and all types of fittings. Cost to include all necessary as required. Necessary Wall cutting and making the wall good and its cost should be included. The pipe to be insulated by 9mm thick nitrile rubber thermal insulation of class 0 category. |
| 208 | Supply, fixing, testing and commissioning of 2 Core x 0.75mm² control wiring ( Sheilded Wire) from outdoor to indoor units to the central controller with all necessary accessories to make it functional as per OEM Recommendation. Make: PolyCab, Havells, Finolex |
| 209 | Supply and fixing of MS Stand as per OEM Recommendation and Placing of Outdour Unit on MS Stand of C Channel. |
| 210 | Supply, Charging of Refrigerant Gas R410a as per OEM Recommendation (Make:- SRF Floron, Honeywell & Dupont) |
| 211 | Supply and fixing of 125mm deep Antivibration Flexible Joints made out of imported fire retardant fabric with extruded aluminium frame/ flange on both sides for Outdoor Units. |
| 212 | Supplying and installation for following size of perforated Hot Dipped Galvanised Iron Covered cable tray for exposed refrigerant pipe With Bends, Tee, Cross Member & Reducer (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 213 | 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 214 | 300 mm wide x 50 mm depth x 1.6 mm thickness. |
| 215 | 450 mm wide x 50 mm depth x 2.0 mm thickness. |
| 216 | Supply and installation, testing, commissioning Outdoor type feeder piller Box made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete all as specifed abd directed & Connisting of the following equipments:-(i) MCCB, 4 pole , 36 KA , 400 Amps adjustable to thermal Magnetic Release -01 No (Incomming)(ii) MCCB, 4 Pole, 16 KA, 100 Amps -03 Nos, 63 Amps -06 Nos, 32 Amps - 10 Nos, (Out going)(iii) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set MAKE : L & T/Secure/Conserv(iv) Solid aluminium bus bar 400 Amp for 3 phase , 200 Amp for neutral, Includes Auto Phase Sequencer to stable Phase.(v) PCC and block Mesonry work for grouting of panel complete all as specified and directed |
| 217 | M&L for control wiring with 4 core X 16 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directedMake : Finloex/Havells/Polycab(Note : Four run of wire with PVC conduit will be considered as one Length.) |
| 218 | M&L for control wiring with 4 core X 10 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directedMake : Finloex/Havells/Polycab(Note : Four run of wire with PVC conduit will be considered as one Length.) |
| 219 | M&L for control wiring with 3 core X 1.5sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 25 mm dia as per IS 694 with on Cable Tray complete all as specified and directedMake : Finloex/Havells/Polycab(Note : Four run of wire with PVC conduit will be considered as one Length.) |
| 220 | S & F 12 way SPN Distribution Box with 240 Volts, 2 to 63 Amps complete all as specified and directed. Make-Legrend / Havells / Seimens |
| 221 | Supply and fixing SPN 40 to 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed. Make-Legrend / Havells / Seimens |
| 222 | Supply and fixing SP 6 to 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed. Make-Legrend / Havells / Seimens |
| 223 | Supply and fixing TPN, 40-63 Amp 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. Make-Legrend / Havells / Seimens |
| 224 | Supply, assembly and erection of Rectangular Aluminium sheet duct (Factory Fabricated)made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as corner, Cleat , Carrige bolt, Gasket and appropriate sealant on langitudinal joints etc complete including necessary MS Channels, Gurder supports as approved by Engr-in-charge including making of hole in any type of wall and making good with plastering work , masonry work and necessary MS channel supports complete all as specified and as directed |
| 225 | 22 Gauge AI Sheet (For OT & Corridor Rectangular Duct) |
| 226 | Supply & erection of 15 mm thick nitrile duct insulation with Aluminum foil. The thermal insulation shall be 15 mm thick non-fibrous, fire retardant, closed cell, tri- dimensional chemically crosslinked polythylene foam, confirming to class O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminum foil complete all as specified and directed. |
| 227 | Supply and fixing insulation acoustic lining of supply air ducting complete with Open cell nitrile Insulation 15mm thick of density 32 kg/cum or above complete all as specified and directed. |
| 228 | Supply and fixing of fire proof double layered canvas cloth connection for indoor unit outlet including inspection opening complete with flanges made out of 22 GSS Sheet on both side for connection to indoor unit and duct with nuts , bolts complete all as specified and directed. |
| 229 | Supply, installation ,testing and balancing of Aluminium Grills with volume control dampers, power coated , extruded aluminium construction complete all specified and as directed. |
| 230 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including painting work complete. |
| 231 | Taking down old AC Units (include Piping, Drain, Stands, & related Items) & Existing False Ceiling deposited to user all as directed by engr-in-charge.Note:-.Contrcator is advised to visit site before quoting rate. |
| 232 | Supply, install, testing and commissioning of PLENUM : 1.Plenum MOC : Stainless steel 304, 2. Thickness - 1.2 mm for 8ft x 8ft 3.Plenum Diffuser Grill : The high quality S.S.304 - Diffuser grill for securing unidirectional air flow according to EN ISO 14644.4.Diffuser grill : SS 304 grill designed to deliver uniform air velocity across the entire HEPA plenum to maintain uniform air displacement on the OT table. Thickness : 1.2mm5.Filter housing and pressure chamber : MOC stainless steel 304 matt polish, thickness 1.2 mm.6.Filter section : - Mini-pleat (H14) grade HEPA Filters - Filters to be D.O.P. tested to remove practices sizing up to 0.3.micron.7.Hepa Filters.: - Total Filter Area : 62 sq. ft for 8ft x 8ft plenum.8.Plenum Lights :-LED light box on all 4 sides with LED tubes - Box size 200mmx2000mm. -LED tube lights9. OT Lamp cut-out- 2ft x 2ft opening for OT lamp shaft |
| 233 | Supply, install, testing and commissioning of Control PanelThe membrane panel will contain 6 services Tiles as follows:1. Time day clock2. Time Elapsed Clock3. Temperature & Humidity Indicator 4. General/peripheral Lighting control5. Medical Gas Alarm Panel upto 6 gases6. TelephoneTime Day Clock will be digital type and clocks have high brightness characters, not less than 30mm in height. Time Elapsed Day Clock will be digital type and clocks have high brightness characters, not less than 30mm in height. Temperature Indicator will indicate the theatre temperature will be connected to the local pressure switches of Air-Conditioning system. Indicator will be digital type have high brightness characters, not less than 30mm in height. General Lighting System incorporates all the necessary controls of the lighting system inside the theatre. The medical gas alarm will indicate High and Low gas pressure for each gas service present in the operating theatre and will have an audible buzzer with mute facility. The medical gas alarms will be connected to local pressure switches located downstream of the last isolation valves.A Hand Free Set Telephone system incorporated in the panel |
| 234 | Supply , install , testing and commissioning of horizontal type pan humidifer 5Kw to 8Kw installed outside AHU with canopy suitable for outdoor type application with digital comunication facility and taking command from AHU complete with suitable size of PVC water tank , Pumps, Spray nozzle piping and electrical accessories complete with necessary foundation and stand as per OEM recommendation , all as specified and directed by Engg-in-charge. Note:Capacity of Humidifier should provide by contractor as per OEM recommendation. |
| 235 | M&L for under deck insulation with EPDM/Nitrile Rubber with Thickness 50 mm (Density : 50Kg/Cum) Class 0 with Temperature Range from -30DegC to 105Deg C. Ceiling Surface need to be Properly Cleaned then Fix Soffit/ Clamp to ceiling, Fix Z or C shaped Aluminiumm channel runner along the length of room 600mm space in one Direction to ceiling by Rawl Plugs/ Dash Fasteners. Use Adhesive to the Ceiling & Place Slabs Of nitrile Rubber/EPDM Insulation in Between by spot sticking method. hold the Insulation slab in position by 22SWG GI Lacing wire Placed Diagonally complete all Specified as Directed. |
| 236 | M&L for under deck insulation with EPDM/Nitrile Rubber with Thickness 50 mm (Density : 50Kg/Cum) Class 0 with Temperature Range from -30DegC to 105Deg C. Ceiling Surface need to be Properly Cleaned then Fix Soffit/ Clamp to ceiling, Fix Z or C shaped Aluminiumm channel runner along the length of room 600mm space in one Direction to ceiling by Rawl Plugs/ Dash Fasteners. Use Adhesive to the Ceiling & Place Slabs Of nitrile Rubber/EPDM Insulation in Between by spot sticking method. hold the Insulation slab in position by 22SWG GI Lacing wire Placed Diagonally complete all Specified as Directed. |
| 237 | X-RAY VIEW BOX: 940 x 640 x 60mmTwin Plate X-ray with body flange to flush in clean room partition, it will be LED Based for uniform illumination and supported by dimmable ballast, the On/Off will be provided on the facia panel of X-ray and Input voltage: 24 DC, 2.5 A Mounting will be flush with the wall to avoid dust accumulation and growth or organisms between wall and panel. Proper spring loaded film clip with rollers will be provided to hold the films firmly and to remove the film without scratches. The system should have electrical safety codes for high & low voltage system.This should be 2-plate X-ray viewing screen.It should be designed to provide flicker free luminance for the film viewing purpose.It should be installed flushed with theatre wall for hygienic and ease of cleaning purposeThe X-ray viewing screen should be designed for the purpose of front access. The X-ray viewing screen should be illuminated by high frequency LED.The dimming is controlled by the usage of dimming control with the PCB that is mounted inside the box. The diffuser should be able to diffuse the light evenly |
| 238 | PERIPHERAL LIGHTS: LED Dimmable (Size: 2*2\\") -Supply, installation, testing and comminssing of recess mounted LED Lights of 36 Watt 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. |
| 239 | MEDICAL GAS PIPE LINE INSIDE OT1. The bidder should ensure that all works carried out as per HTM 02-01/NFPA 99C/DIN/ISO 7396-1 standard.2. Bidder should provide Oxygen, Nitrous Oxide, Air4, Air7, Co2, Vacuum etc. supply to Operation Theatres from the existing lines terminated outside the MOT.3. Copper pipes should be of solid drawn, seamless, deoxidized, non-arsenical, and half hard, tempered and degreased copper pipe. All copper pipes should be degreased & delivered capped at both ends. 4. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition. The copper pipe should comply with EN 133485. It should be third party certified from Lloyd or SGS or metallurgy lab. 6. All Copper Pipes Fittings must be duly Medical Grade, seamless, fully degreased.7. The copper fitting should comply with EN 1254-1Entire installation should be done under direct supervision of the qualified and trained engineer who is certified as authorized person of HTM0201 and should be awarded as level 4 professional award. Handover certificate should also be signed by him withregistration number.Aadhar card of engineer, Valid certificate and valid authorization in the name of bidder should be submitted along with the bid. He should issue a report against handover of satisfactory installation as per guidelines of HTM02. And should be submitted to the authorities with handover documents. |
| 240 | Double Dome light with base plate:1. Dual Dome Ceiling mount structure2. Output Lux intensity of 1,50,000 Lux at 1 meter in each dome3. Power consumption of less than or equal to 120 watts per dome4. Colour temperature of the LED to be equal to daylight colour temperature - 50000 k5. Life of LED-50,000 hours or more6. Six motions in each arm to achieve all positions and angles7. More than 1100 mm up-down movement for both Domes8. All five rotary motions in each arm to have stopper less design for continuous rotation 9. Wide reach of more than 2 meters in all direction from centre for both arms to cover majority of operation room area10. Wide operating voltage range from 90 v to 260 v to cover mains voltage fluctuations11. Colour LCD with Touch Screen Control panel for each dome12. User selectable intensity variation with digital display from 0% to 100% individual for each dome13. Digital Display of Life of LED used in hours for each dome14. Wireless control of Light through Mobile app15. Data Storage, Analysis and Report Generation from Mobile App16. Fully Cardanic Quarter Sized Double yoke sets in domes for more freedom of movement and easy handling17. Availability of Direct battery operation option18. Provision of Camera mounting on each Dome19. Sterilisable & detachable Plastic handle at the centre of each dome for focus adjustment20. Aerodynamic pattern with air movement through the dome21. To have ISO 13485 & ISO 9001 certification and CE mark |
| 241 | Supply , install , testing and commissioning of Isolation transformer, floor mounted with different compartment inside, isolation panel system of required capacity shall be provided for every operation theatre to ensure the safety of staff and patient. System shall have isolators proveded through leakage relays etc. if required, according to IEC recommendation. These systms are to be commissioned by specialists. Normally Single phase, 50 Hz, indoor type, Copper Wound, Air Cooled, Class of insulation A, metallic body powder coated designed for Input Voltage range 240V, +- 5%, with ratio 1 :1, efficiency more than 95%. Potential difference between neutral to earth less than one volt with all standard fittings of capacity 10 KVA. It shall be medical grade, fault detection feature, chall be compliant to CEI 64-8/IEC 60364-7- 710/BS 7671 standard. The IPS shall be to integrate with surgeon control panesl as standard. Isolation panel system shall have facility to detect fault of leakage current for each circuit (minimum 12 circuits) and same shall be integrated with touch screen control panel of MOT and alarm status shal be displayed on the touch screedn control panel all as specified and directed. Please Enable Macros to View BoQ information |
| 242 | Supply , install , testing and commissioning of Isolation transformer, floor mounted with different compartment inside, isolation panel system of required capacity shall be provided for every operation theatre to ensure the safety of staff and patient. System shall have isolators proveded through leakage relays etc. if required, according to IEC recommendation. These systms are to be commissioned by specialists. Normally Single phase, 50 Hz, indoor type, Copper Wound, Air Cooled, Class of insulation A, metallic body powder coated designed for Input Voltage range 240V, +- 5%, with ratio 1 :1, efficiency more than 95%. Potential difference between neutral to earth less than one volt with all standard fittings of capacity 10 KVA. It shall be medical grade, fault detection feature, chall be compliant to CEI 64-8/IEC 60364-7- 710/BS 7671 standard. The IPS shall be to integrate with surgeon control panesl as standard. Isolation panel system shall have facility to detect fault of leakage current for each circuit (minimum 12 circuits) and same shall be integrated with touch screen control panel of MOT and alarm status shal be displayed on the touch screedn control panel all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail