Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #55974883

Tender For Construction Of 04 Technical Building At Cad Pulgaon Under Ge Pulgaon

Issued by Statutory Bodies & Commissions/Committees · Pulgaon, Maharashtra
Tender Value
27.53 Crore
Estimated cost
Bid Submission
18 Jul 2026
10 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pulgaon → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 04 Technical Building At Cad Pulgaon Under Ge Pulgaon

BOQ

Name of Work:- CONSTRUCTION OF 04 TECHNICAL BUILDING AT CAD PULGAON UNDER GE PULGAON
Sl. No. Item Description
1Note:-Please refer schedule 'A' notes before quoting the tender.
2GENERAL SUMMARY
3Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule ‘A’ Part- I (Ref prepriced schedule attached seperately)
4Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)
5Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)
6Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)
7Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY AND DG SET WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)
8Lump sum price worked out by the contractor for ROAD, PATH, CULVERTS AND HARDSTANDING WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
9Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately)
10Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VIII (Ref prepriced schedule attached seperately)
11Lump sum price worked out by the contractor for FIRE FIGHTING & FIRE ALARM WORKS as listed in Schedule ‘A’ Part-IX (Ref prepriced schedule attached seperately)
12Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS as listed in Schedule ‘A’ Part-X (Ref prepriced schedule attached seperately)
13Lump sum price worked out by the contractor for DEMOLITION AND DISMANTLING WORKS as listed in Schedule ‘A’ Part-XI (Ref prepriced schedule attached seperately)
14Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKS as listed in Schedule ‘A’ Part-XII (Ref prepriced schedule attached seperately)
15SCH 'A' Pt - XIII (MISCELLANEOUS ITEMS)
16INTERNAL ELECTRIFICATION WORKS NOTE:- For items of INTERNAL ELECTRIFICATION notes given at the beginning of Sch ‘A’ Part-III ( INTERNAL ELECTRIFICATION) shall also be applicable.
17S&F LED lamp 9/10W , in Type B22, 230V AC, 50HZ single phase including bakelite batton holder with all fitting fixing accessories complete all as specified and directed.
18S & F Flame proof - weather proof LED flood light fitting with protection IP-65 suitable for 60 Watt for indoor type complete all as specified and directed.
19M&L flame proof distribution board TPN 4 way ( Totally enclosed dust and flame proof /jet proof ( IP-65 protection) including flame proof MCB TPN 32-01 NOS, SP 5 to 30 Amps-12 NOS 240 volts AC 10KA (10 Nos) and RCCB 01 Nos 40 Amps, TPN MCB 40 Amps 415 volts AC 50 Hz 16 KA (01 No) Flame proof suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981 , with complete internal bus bar & wiring upto terminals.
20M&L flame proof distribution board SPN 8 way ( Totally enclosed dust and flame proof /jet proof ( IP-65 protection) including flame proof MCB SPN 32 Amp-01 NOS, SP 5 to 30 Amps-6 NOS 240 volts AC 10KA, Flame proof suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981, with complete internal bus bar & wiring upto terminals.
21EXTERNAL WATER SUPPLY WORKS NOTE:- For items of EXTERNAL WATER SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-IV (EXTERNAL WATER SUPPLY WORKS) shall also be applicable.
22M&L for construction of brick Masonarry valve pit chamber 900mm x 900mm x 900mm (internal size), 100 mm thick PCC 1:4:8 type D2 lean concrete foundation using 40 mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick build in CM 1:6 rendaring 15mm thick in cement 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 3.5mm thick MS sheet steel cover fixed on 50 x50x6 mm thick angle iron frame embbeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS coats of synthatic enamel paint of approved shade over a coat of primer (Red oxide) to all exposed surface complete all as specified and directed.
23EXTERNAL ELETRIC SUPPLY NOTE:- For items of EXTERNAL ELECTRIC SUPPLY notes given at the beginning of Sch ‘A’ Part-V (EXTERNAL ELETRIC SUPPLY) shall also be applicable.
24Supply and fixing PVC moulded case cable juction box outdoor type of size 200x140x95 mm with hinged front open door including locking arrangement and with one number MCB SP 6 Amp with necessary clamps made out of 25mm flat GI strip, nut, bolt etc and providing 3 core copper conductor 1.5 Sqmm from PVC junction box to street light fitting in with proper clamping complete all as specified and directed.
25Supply and fixing new 40mm bore or next suitable size (for 1x60 Watt LED fitting) light grade GI bracket 1.2 Mtr long bent to shape by cutting welding and well finishing including MS Clamp of flat iron of size 25x5mm suitable length 2 Nos complete for steel tubular poles with nuts,bolts and painting with two coats of aluminium paint over a coat of primer on MS Clamp complete all as specified and directed.
26Supply and fixing Double wall corrugated High Density POLYMER Ethylene (HDPE) pipe of size 50 mm as per IS 14930 (Part-2):2001, Laid in Trenches/floors and fixed on walls/poles, with and including necessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed.
27Supply and fixing Double wall corrugated High Density POLYMER Ethylene (HDPE) pipe of size 90 mm as per IS 14930 (Part-2):2001, Laid in Trenches/floors and fixed on walls/poles, with and including necessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed.
28M&L trenchless boring for Cable laying 150 mm bore size, not Exceeding 1.5 meter depth Complete all as specified and directed.
29Supply, installation, commisioning and testing Compact sub stn 160 kVA with fencing all as specified and directed consist of following components :-(a) 160 KVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oil immersed Copper Wound Step Down “BIS Marked & BEE Star Labelled” Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling BoxTransformer as per IS-1180:2014 Losses @50% Load - 570W Losses @100% Load - 1700W(b) HT Section 11KV, 630A, Indoor Type 26.3 KA Load Break Switch (LBS)with fuse trip, earth switch, dynamic MIMIC arrangement, 230 V AC shunt trip coil and 2no+2nc aux. contacts.(c) LT Panel comprising of following switchgear on LV Side;Incomer - 01 no.-320 Amp 415V 4 Pole 36KA MCCB with thermal magnetic based releasewith O/L & S/C protection outging - 200 amp,415V,28KA MCCB -02 nos . - RYB Indication Lamp - Ammeter - Voltmeter(d) MS Steel Sheet enclosure suitable for Outdoor Installation with MS channels (Base). 01 Set Provision for receiving Incoming and Outgoing cables through Bottom entry, Excluding Termination Kit and Glands .
30Supply, installation, testing & commissioning of diesel engine driven silent generating set sound proof acoustic enclosure (canopy CRCA sheet 2mm thick & noise level below 75 decible/M) with AMF panel inside the caropy, prime rating 8KW/10 KVA, 1500 RPM, 3phase, 415 volt, 4 wire, 50 Hz and power factor 0.8, complete all as specified and comprising the following and set of tools and maintenance spares as recommended by the manufacturer.
31(A) ENGINE PRIME MOVER:- Suitable for driving 8KW/10 KVA alteranator, liquid cooled, four stroke, two cylinder, battery start diesel engine, fuel tank of adequate capacity for 8 hrs running, Moef certified power not less than 23 HP and confirming to latest BS/IS specification rated for continous running capable of taking 10% over load for one hour in any 12 hrs operation, complete taking into consideration duration due to altitude/temp, mounted on MS frame pedestal support with the following standard accessories from the make specified in particular specification Part II (i) Fly wheel to match with the flexible coupling disc (i) Flexible coupling with guard (iii) Air cleaner paper element type (iv) Lubricating oil filter fuel filter flow element type (v) Fuel pump(vi) Radiator with fan (vII Governor for class A2 governing all as per OEM specifications and latest IS standrard (viii) Starter motor for electric start complete with charging alternator lead and acid maintenance free battery 01 No 12 V DG manufacture recommended with 2 years guarantty, battery leads with the copper conductor of adequate size and length. Diesel Engine control Panel compaliable with Remote mounting system and comprising of all standard fitment as per companys specification ON/OFF switch multi purpose meter with indication of ampere, voltage, hours, RPM, temperature, fuel position, power factor instrument panel duly wired into prime mover and lubricating oil temperature, lubricating oil pressure, battery charge ampere, push button start/stop, high water temperature etc complete all as specified and directed by Engr-in-Charge.(B) ALTERANATOR:- 8KW/10 KVA at 0.8 power factor brushless self-existed, self-regulated, 3 phase, 50 Hz, 415 volt 1500 RPM, 4 wire screen protected class 'H' insulation, drip proof three from simulation problem continuous rating conforming to IS 4722 or as per the latest IS specification complete with the automatic voltage regulator output voltage regulated between +/-1% on set voltage from No load to full load. Make of alternator Stamford (CGT) or equivalent Model from make specification in particular specification Part II. Please Enable Macros to View BoQ information
32(A) ENGINE PRIME MOVER:- Suitable for driving 8KW/10 KVA alteranator, liquid cooled, four stroke, two cylinder, battery start diesel engine, fuel tank of adequate capacity for 8 hrs running, Moef certified power not less than 23 HP and confirming to latest BS/IS specification rated for continous running capable of taking 10% over load for one hour in any 12 hrs operation, complete taking into consideration duration due to altitude/temp, mounted on MS frame pedestal support with the following standard accessories from the make specified in particular specification Part II (i) Fly wheel to match with the flexible coupling disc (i) Flexible coupling with guard (iii) Air cleaner paper element type (iv) Lubricating oil filter fuel filter flow element type (v) Fuel pump(vi) Radiator with fan (vII Governor for class A2 governing all as per OEM specifications and latest IS standrard (viii) Starter motor for electric start complete with charging alternator lead and acid maintenance free battery 01 No 12 V DG manufacture recommended with 2 years guarantty, battery leads with the copper conductor of adequate size and length. Diesel Engine control Panel compaliable with Remote mounting system and comprising of all standard fitment as per companys specification ON/OFF switch multi purpose meter with indication of ampere, voltage, hours, RPM, temperature, fuel position, power factor instrument panel duly wired into prime mover and lubricating oil temperature, lubricating oil pressure, battery charge ampere, push button start/stop, high water temperature etc complete all as specified and directed by Engr-in-Charge.(B) ALTERANATOR:- 8KW/10 KVA at 0.8 power factor brushless self-existed, self-regulated, 3 phase, 50 Hz, 415 volt 1500 RPM, 4 wire screen protected class 'H' insulation, drip proof three from simulation problem continuous rating conforming to IS 4722 or as per the latest IS specification complete with the automatic voltage regulator output voltage regulated between +/-1% on set voltage from No load to full load. Make of alternator Stamford (CGT) or equivalent Model from make specification in particular specification Part II. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55974883
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 27.53 Crore
LAST DATE 18-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Construction Of 04 Technical Building At Cad Pulgaon Under Ge Pulgaon
Basic Detail
Tender No CEBZ/PUL/TOKEN/02 OF 2026-27
Bidding Type Tender
Location
City Pulgaon
State Maharashtra
Key Dates
Publish Date 13 Jun 2026
Submission Date 18 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 27.53 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Not Available
Document List
BOQ_864580.xls
c13a14f4-7dd1-4058-a115-e8c331d2316c.html
drgsss.pdf
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_864580.xls

html

c13a14f4-7dd1-4058-a115-e8c331d2316c.html

pdf

drgsss.pdf

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders