| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | Dismantling posts or struts (wood, steel or RCC) any section embedded in concrete, masonry, brick work, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 3 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 4 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlarfacings, dressedstonework and precastconcrete articles all as specified and directed. |
| 5 | Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft /loose soil complete all as specified and directed. |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan (including getting out and disposal of excavated earth lead upto 50 mtr and and lift upto 1.5 m, complete all as specified and directed. |
| 7 | All as per ser Item No.5.00 here-in -before but each additional 1.5 m or part thereof in depth beyond the first 1.5 m complete. |
| 8 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed. |
| 9 | M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation, filling in and mass concrete complete all as specified and directed. |
| 10 | Use & waste for form work to sides of concrete foundations, footings bases of columns, raft and raft beams, sides and soffits (if any) of foundaton and plinth beams; and similar work, vertical or to batter for rough finished surfaces of concrete complete all as specified and directed. |
| 11 | M&L reinforcement cement concerete for foundation footings, plinth beams, bases for column etc type M-25 grade using 20 mm graded stone aggregate complete all as specified and directed. |
| 12 | Use& waste for form work to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surfaces of concrete complete all as specified and directed. |
| 13 | M&L for reinforced cement concrete for column etc type M-25 grade using 20 mm graded stone aggregate complete all as specified and as directed. |
| 14 | Use & waste for formwork to sides and soffits offloor or roof beams, beam haunch-ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors andbeams, etc also splays between floors and beams etc rough finished surfaces of concrete all as specified and directed. |
| 15 | M&L reinforcement cement concerete for beam etc type M-25 grade using 20 mm graded stone aggregate complete all as specified and directed. |
| 16 | S&F for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookingends and bindingwith and includingmild steel wire(annealed) not lessthan 0.9mm dia or securing with clips quality complete all as specified and directed. |
| 17 | All as per ser Item No.15.00 here-in -before but 6 to 8 mm dia TMT bar for stirrups |
| 18 | M&L for brick work with fly ash bricks builts in CM (1:4) straight or curved on plan exc 6m mean radius built with fly ash brick complete all as specified and directed |
| 19 | M&L for rendering 15 mm thick in CM (1:4) on fair faces of bricks or concrete surface finished even smoth without extra cement all as specified. complete all as specified and directed. |
| 20 | M&L for moorum in returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified and directed. |
| 21 | Removal excavated material n exe 50 mtr and depositing where directed. complete all as specified and directed. |
| 22 | M&L for 18 to 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4 as backing coat for receiving granite complete all as specified and as directed. |
| 23 | M&L for steel gate, including pintle hinges, stops, hand-made sliding bolts, etc. framed work, forged into spikes, framed guard bars; barred iron doors, and drilled for fixing of steel sheeting or other covering similar work conforming to Fe.290 Gde-E-165 complete all as specified and directed. |
| 24 | S&F angle iron fencing posts including cutting tops to shape as directed, drilling holes, notching for wire ets; flat iron fillets including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 25 | M&L for preparation of newly plastered wall surfaces and applying coats of white two coats of cement based paint over a coat of alkali resistant primer complete all as specified and directed. |
| 26 | M&L for preparation of new or previously untreated surfaces of steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed. |
| 27 | S&F galvanised 2 strand, mild steel barbed wire, 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing ortying at crossings with and provision of galvanised mildsteel wire complete all as specified and directed. |
| 28 | M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate in kerbs /copings/bed plates and the like including weathering ,slightely rounded or chamfered angles and throating as directed including use of necessary form work complete all as specified and directed. |
| 29 | M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in drain and surface channel complete all as specified (Forming fair finished to drain/channels shall be measured and paiid seperately complete all as specified and directed. |
| 30 | Extra for forming fair finished surfaces of drain or channels, inner girth 40 cms, using extra cement including forms, moulds mitred/ stopped ends etc., complete. |
| 31 | Deduct Schedule of credit (calculation will be done off line) Rs. 45500.00 Please Enable Macros to View BoQ information |