| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work:Repair/Maintenance of Pipelines, Control Valves, Switch gears and allied works at 14 EME, 222 ASC, Tushar Vihar, 874 A Coy, 57 WEU and other locations under GE (Utilities) Udhampur. Contract No: GE/U-73/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth,foundation etc. or for shafts, wells, cesspits, maneholes, pier holes etc. and taking out/laying of pipe lines of soft/dense soil. Complete all as specified and directed by Engr-in-Charge. |
| 3 | Returning, filling, levelling, spreading, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engr-in-Charge. |
| 4 | Removing surplus soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 5 | Taking up or down CI/DI/MS water mains pipe 300 mm bore (including all fittings), with flanged/welded butt joint/ spigot and socket with rubber gasket Complete all as specified and directed by Engr-in-Charge. |
| 6 | Refixing MS/DI/CI pipe obtained from item No. 04 above and connections in new or old position (walls, trenches, ceiling and floors etc) of size 300 mm bore complete inlcuding main / branch connections Complete all as specified and directed by Engr-in-Charge. |
| 7 | Supply, laying, jointing and testing MS ERW pipe class 'B' of bore 300 mm having wall thickness 6 mm with permissible tolerance + 10% conforming to IS-3589, ISI marked alongwith circular welding joints laid in trenches/ along road/ on surface/ slopes/pillars/ culverts/ causeways etc, Complete all as specified and directed by Engr-in-Charge. |
| 8 | Taking up or down old unseviceable GI pipe of size 150 mm dia including all fittings Complete all as specified and directed by Engr-in-Charge. . |
| 9 | Refixing GI/CI pipe obtained from Item No.19 above and connections in new or old position (walls, trenches, ceiling and floors etc) of size 150 mm dia complete including main branch connections Complete all as specified and directed by Engr-in-Charge. |
| 10 | Supply & fixing GI pipes of size 150 mm dia, medium grade, galvanized with all fitting such as bends, tees, nipples, union and sockets, clamps etc laid in trenches, under floor/walls etc Complete all as specified and directed by Engr-in-Charge. |
| 11 | Taking up or down GI pipe of size bore of pipe 100mm diaincluding all fittings complete all as specified and directed by Engr-in-Charge. |
| 12 | Description all as per Ser Item No 10.00 here-in-before, but of size 80mm dia |
| 13 | Description all as per Ser Item No 10.00 here-in-before, but of size 50mm dia |
| 14 | Description all as per Ser Item No 10.00 here-in-before, but of size 40mm dia |
| 15 | Description all as per Ser Item No 10.00 here-in-before, but of size 25mm dia |
| 16 | Description all as per Ser Item No 10.00 here-in-before, but of size 20mm dia |
| 17 | Refixing GI/CI pipe obtained from Item No. 13 above and connections in new or old position (walls, trenches, ceiling and floors etc.) of fbore 100mm dia. Complete including main/branch connections complete all as specified and directed by Engr-in-Charge. |
| 18 | bore of pipe 80mm dia |
| 19 | bore of pipe 50mm dia |
| 20 | Supply & fixing only GI pipes in repair of bore of pipe 100mm dia, medium grade, galvanized with all fitting such as bends, tees, nipples, union and sockets, clamps etc laid in trenches, under floor/walls etc complete all as specified and directed by Engr-in-Charge. |
| 21 | Description all as per Ser Item No 17.00 here-in-before, but of dia 80 mm dia |
| 22 | Description all as per Ser Item No 17.00 here-in-before, but of dia 50 mm dia |
| 23 | Description all as per Ser Item No 17.00 here-in-before, but of dia 40 mm dia |
| 24 | Description all as per Ser Item No 17.00 here-in-before, but of dia 25 mm dia |
| 25 | Description all as per Ser Item No 17.00 here-in-before, but of dia 20 mm dia |
| 26 | M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) cement concrete in as in foundation filling of pillar complete all as specified and directed by Engr-in-Charge. |
| 27 | Supply fabrication and fixing MS joints like Flanged, bends, Tapers, tail piece (any type) caps, plugs for 100 mm to 300 mm bore pipe complete all as specified and directed by Engr-in-Charge. |
| 28 | Material and labour for spraying herbicide (Round up) on area to remove unwanted vegitation/grass at various locations complete all as specified and directed by Engr-in-Charge. |
| 29 | Material and labour for shifting heavy items /using excavator / cleaning areas / cleaning site by providing crane/hydra/excavators/tractors/trolley ect as required at site complete all as specified and directed by Engr-in-Charge. |
| 30 | Supply only lead wool /spunyarn for jointing the CI pipes complete all as specified and directed by Engr-in-Charge. |
| 31 | Supply only leadl for jointing socket and spigot CI pipes complete all as specified and directed by Engr-in-Charge. |
| 32 | M&L for Premix ready mix road repair patching compound for instant road repair manufactured with a blend of bitumen, aggregates and high grade polymer to ensure immediate bonding with existing surface available in bag of 25 Kg, complete all as specified and directed by Engr-in-Charge. |
| 33 | Material and labour for fabrication of MS sheets ,angle iron in replacement of old pit cover with necessary welding work and one coat of red oxide primer to the welded works and painted with black enamel paint complete all as specified and directed by Engr -in - Charge. |
| 34 | Supply and fix in replacement cast iron sluice valve suitable of size 150 mm (PN 1.6) as per IS : 14846 with iron wheel head both end flanged, non rising type and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,complete all as specified and directed by Engr-in-Charge. |
| 35 | Description all as per ser item No 31.00 here-in-before, but of size 100 mm dia |
| 36 | Description all as per ser item No 31.00 here-in-before, but of size 80 mm dia |
| 37 | S&F of Gun-metal, globe or gate valves, 50 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge. |
| 38 | Description all as per ser item No 34.00 here-in-before, but upto 40 mm bore. |
| 39 | Description all as per ser item No 34.00 here-in-before, but upto 25 mm bore. |
| 40 | Description all as per ser item No 34.00 here-in-before, but upto 20 mm bore. |
| 41 | Description all as per ser item No 34.00 here-in-before, but upto 15 mm bore. |
| 42 | Providing and carrying out welding of any type (electric arc / gas welding) for fabrication, erection or repair of steel/MS/GI members, brackets, frames, supports, angles, flats, pipes etc. of any size and thickness, including surface preparation, alignment, welding consumables, finishing and all incidental works, complete, measured per stick/ filler rod / welding rod, complete all as specified and directed by the Engineer-in-Charge |
| 43 | Repair and overhauling of pressure filter of capacity 10,000 GPH of size 1625mm dia ,3250 mm height by carrying out the following works :-a) Opening of manhole cover, hand hole cover & pipe line by taking out / cutting the old rusted MS bolts, nuts & washers etc & keeping in safe custody, taking out the exhausted filtering media, PVC strainers and disposal of exhaust media out side the campus, including dismantling of unserviceable PVC strainer by scrapping inside the Softing vessel. Refixing the man hole cover, hand hole cover and pipe line etc including provision of fixing material i.e. rubber gasket, nuts, bolts and washer etc and testing on completion complete all as specified and directed by the Engineer-in-Charge.(b) Cleaning and scrapping the inner periphery of the vessel and flushing out with fresh water to remove the traces of the defused resin, rust etc complete all as specified and directed by the Engineer-in-Charge.(c ) Supply and filling new life filter media of i.e. graded gravels fine / course and special quartz filter and source Breaker as existing complete all as specified and directed by the Engineer-in-Charge. |
| 44 | (d)Supply and fixing of Strainers of qty in each filter complete all as specified and directed by the Engineer-in-Charge.(e) Material and labour for painting of inner surfaces of the vessel with two coats of Anti Corrosive Black paint suitable for drinking water purpose over one coat of primer.(f) Material and labour for painting of outer surface of the vessel with two coats of synthetic enamel paint complete all as specified and directed by the Engineer-in-Charge.(g) Rubber gaskets |
| 45 | Material & labour for dewatering the dug well by means of submerssible pump and empty the well of all water.If sludge is present use raw water pump for handling solids.Remove all sludge and debris from the bottom and apply chlorine solution to the walls and scrub with a long handled brush to remove algae,slime and mineral buildup.Repair any cracks in the well lining with a stiff mortar.Prepare a chlorine solution and add it to the well water for disinfect the well.Allow the the solution to stand several hours to kill bacteria effectively. Dewater the well and allow the well to recharge and test the residual chlorine level.If it is too high repeat the dewatering and recharging process untill the level is acceptable. After disinfection water will be tested by a certifed lab for bacteriolagical and other contaminants test complete all as specified and directed by Engr-in-Charge. |
| 46 | Dismantling and taking down old unsv LT Panel and Supplying, installing, testing & commissioning indoor type cubical panel board outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick and MS angle section 50x50x6 mm suitable for floor mounted with nuts & bolts , frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/openable with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Aluminium bus bar of 400 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following, complete all as specified and directed by Engineer-in-Charge:- |
| 47 | a) Supply and fixing MCCB 250 Amps, 36 KA 4 pole 415 Volts AC, adjustable type, complete (incoming)-01 Nos.b) Out going MCCB TP 100 Amps 36 KA adjustable type - 3 Nos c) Star Delta starter with contactor for 40 HP 02 Nosd) Interconnection of MCCBs , to Busbar with copper strip of suitable size with PVC insulated colour coaded heat shrinkable type sleeves - 1 Jobe) RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nosf) Digital Ammeter of range 0-400 A, auxiliary voltage 230 volts with selector switch -01 Nosg) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 Noh) Single phase preventer , Over load /under voltage relay , Phase sequence corrector 01 jobMisc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cable lugs, sleeves, cable glands etc complete |
| 48 | Material and labour for fabrication, supply, fixing and commissioning signage boards for installations of size not less than 1.0M x 1.0M made out of ACP sheet of 3mm thickness with english alphabets and numerics cut out and designed out of 3mm thick acrylic sheet neatly pasted on the ACP board with MES logo ,framed and standed in stainless steel,both legs of height 1.5M above the ground level and embeded in pcc 1:4:8 (45 cm below GL)l with necessary fixing arrangement as per the site requirement complete all as specified and as directed..Note:- (a) Before fabrication of the display board, the contractor has to produce a paper printout detailing all documents and matter to be displayed so as to get it inspected and passed by Engr-in-charge. (b) Matter to be displayed, colour of the ACP sheet and colour of Retro Reflective sheet will be as specified and directed by Engr-in-Charge. (c) The quoted rate is deemed to be inclusive of cost of labour and materials required for fixing of the display board at various locations. |
| 49 | M& L for dismantiling and shifting of pump and motor of capacity upto 50HP from B res to JNE , B Well or vice versa by means of transport and fixing the same on the plinth by providing new pcc 1:3:6 and fixing the bolt with frame and getiing the allignment of pump and motor connecting to the suction & delivery ,neccessary welding works ,Motor connection with starter ,testing complete all as specified and directed by Engr in Charge. |
| 50 | M & L for Repair/Replacement of clariflocculator CENTRAL BEARING ASSEMBLY complete with CI Housing, Shaft, bearing, grouting bolt, Current Collector Box etc.01 No, replacement of carbon brush assembly 01 No, replacement of MS chains 01 Nos, flocculator driving case -01Nos, clarifier driving drum -01 Nos,flocculator driving case -01 Nos .FLOCULATOR DRIVING ARRANGEMENT replacement of floculator/ reddle and shaft complete with Bearing Housing, Coupling, Bevel Gear, Motor, Gear Box, flexible coupling etc. CLARRIFIER END CARRIAGE DRIVE ASSEMBLYcomplete with idle shaft driving wheel, plummer bearing, chain sproket, motor, suitable gear box, Flexible Coupling etc., repair to reduction gear by replacement of gears, Gear shaft for end carriage type U-400 ratio 1:50 , complete all as specified and directed by Engineer-in-Charge. |
| 51 | Note :- (i) T&P required for lifting and lowering for clarifloculator tank compartment shall be provided by the contractor.(ii) Necessary safety precautions for workmen shall be the responsibility of the contractor.(iii) The cost of transportation to workshop and back is deemed to be included in the quoted rate. (iv) T&P required such as Hydra Crane shall be provided by the contractor and rate for the same be included in the quoted rates. |
| 52 | Supply, installation & commissioning of Multi-parameter Analyser complete with advanced microprocessor based system to analyse and dispay details of COD/BOD/TSS/PH/TSS/Flowmeter etc with OFFSET correction , touch screen, alpha numeric display 240x128 pixel, LCD with backlit etc comply to IP54 including all safety measures relay for dry contact alarms for high and high-high set points,monitor failure, microprocessor failure having digital output RS232/RS485. The online multi parameteres analyser will comply with POnline Continuous Effluent Monitoring System (OCEMS) requirements of CPCB and data will be transmitted to server of the DPCC/MES in confirmation with CPCB Guidelines.Method : COD/BOD/TSS: UV-VIS absorption dual beam spectrophotometry at 190~750nm & pH:Potentiometric with combination pH sensor Calibration : Online auto zero calibration for COD/BOD/TSS with OFFSET correction. Manual SPAN calibration for COD/BOD/TSS/pH (inplace). Operation cycle;Continuous or batch type ,Cleaning : Automatic built-in cleaning function, complete all as specified and directed by Engineer-in-Charge. |
| 53 | User programmable Operation ,Reagent and chemical free analysis Compensation : Auto turbidity and colour compensation, Interference : Independent of flow and pressure variations .Type :Advanced microprocessor-based system Measuring cycle : Programmable / normally 3-5 minutes Analog output : 0/ 4-20 mA. DC, isolated Enclosure protection : Comply to IP54, Stainless steel enclosure Relay outputs : Dry contact alarms for high and high-high set points, monitor failure, microprocessor failure Power supply : 110- 230V AC,50Hz, 30 VA Digital output : RS 232/ RS 485 Ambient temperature : 0 to 50 Deg. C .One set of chlorine analyser for monitoring of residual chlorine. Out put - 4-20mA Resolution:0.01 mg/l. Acciracy < 2% of full scale Response Time T90 in 60 sec,Temperature operating : -5 to + 70 degree celsius, Sensor measuring electrode type :Amperometric type (potentiometric free chlorine sensor) Make Enviro Emperical,Aaqua pristine or any other equivalent model . |
| 54 | Supply, Installation, Testing, Commissioning and Programming of Reporting Software with user configurable reports along with data collection of parameters, events, alarms complete with user defined logo, user name, date and time, page no.header and footer. Note: All the monitoring systems to be shown in single screen, the system to be analysed and read from any system through internet, the cost of data transmission and modems etc included in the rates for all montoring systems for a period of one year,cost and recharge all to be included in the quoted rates. |
| 55 | Supply and fix Electromagnetic flow meter with inline full bore electormagnetic type havong bi- directional flow and tolallisation facitlity etc complete all as specified and directed. Note: The rates includes all cutting, welding, provn. of pipes,flanges, fixtures and accessories for succesful installation in outlet pipe from filters to treated water tanks of 80mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 56 | Dismantling and taking down old unsv LT Panel and Supplying, installing, testing & commissioning indoor type cubical panel board outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform with nut and bolts, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl aluminium bus bar of 1900 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following, complete all as specified and directed by Engineer-in-Charge:-Make : (Hanson,DV Electromatics, Universal) |
| 57 | a) 4 Nos bus bar of equal size made out of aluminiumr strip of suitable size with PVC insulated coloured heat shrinkabal type sleeves, of rating 1900Amps, mounted on non cracking resin type insulators - 01 Jobb) LT ACB, 4 pole, 415 volts, 50 kA, 1250 Amps mannual draw out type with thermal magnetic release, Icu=Ics=Icw 50kA (1 Sec) with accessories confirming to IEC 60947-2&3 - 01 No (Incoming)c) ON Load change over 4 Pole 1250 Amps 415 V-01 Nosd) Interconnection of ACBs O/G to Change over with suitable busbar and Out going of change over will be provided with aluminum busbar for tapping of cables of appox 0.60 mts mounted on insulators.e) Under voltage, over voltage ,over load relay,phase sequence corrector - 01 Jobf) Interconnection of ACBs , Change over to Busbar with aluminium strip of suitable size with PVC insulated colour coaded heat shrinkable type sleeves - 1 Jobg)RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nosh)Digital Ammeter of range 0-800 A, auxiliary voltage 230 volts with selector switch -02 Nos |
| 58 | i) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 Noj)Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cable lugs, sleeves, cable glands etc complete |
| 59 | Supply, installing, testing and commissioning, factory made and tested, automatic power factor control panel (APFC Panel), indoor type , cubical front opening type. The panel shall be of protection class IP- 54 and made of 16 SWG CRCA MS sheet and MS angle 40x40x6mm thick, powder coated finish over one coat of red oxide primer primer on outside surface and painted inside with two coats of red oxide primer, including internal wiring with PVC insulated solid copper conduit cables, IS – 694 marked, 1100 volts grade of appropriate size but not less than 2.5 sqmm and comprising of the following :(a) Incoming MCCB, LT, 4 pole, 200Amp rating, 35 KA rupturing capacity : 01 Nos . (b) Capacitors type MPPH (Heavy duty) as per IS 13585/ hot I / 1994 / IS 13340/ 1993, for 120 KVAR, having 5 nos of steps / stages. (3 x,5,3 x10,25,50)(c) Microprocessor based, modular type , Intelligent APFC relay capable of having self adjustment to any capacitor value suitable to maintain power factor between 0.9 to 0.99 with digital indication of power factor, preset parameters and having in built capability of indication and elimination of defective capacitor steps. (d) Direct capacitor for Transformer no load losses 7.5 KVAR with TPN MCB 25 Amps |
| 60 | Note :-(i) The APFC panel and all connected items mentioned shall be of the same make. (ii) The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification, shall be deemed to be included unless specifically excluded. The equipment shall conform in all respects to high standards of engineering design and workmanship and shall be capable of performing in continuous operation. |
| 61 | Supply, installing, testing and commissioning, factory made and tested, automatic power factor control panel (APFC Panel), indoor type , cubical front opening type. The panel shall be of protection class IP- 54 and made of 16 SWG CRCA MS sheet and MS angle 40x40x6mm thick, powder coated finish over one coat of red oxide primer primer on outside surface and painted inside with two coats of red oxide primer, including internal wiring with PVC insulated solid copper conduit cables, IS – 694 marked, 1100 volts grade of appropriate size but not less than 2.5 sqmm and comprising of the following, complete all as specified and directed by Engineer-in-Charge : |
| 62 | (a) Incoming MCCB, LT, 4 pole, 100Amp rating, 35 KA rupturing capacity : 01 Nos . (b) Capacitors type MPPH (Heavy duty) as per IS 13585/ hot I / 1994 / IS 13340/ 1993, for 75 KVAR, having 5 nos of steps / stages. (5,10,10,25,25,)(c) Microprocessor based, modular type , Intelligent APFC relay capable of having self adjustment to any capacitor value suitable to maintain power factor between 0.9 to 0.99 with digital indication of power factor, preset parameters and having in built capability of indication and elimination of defective capacitor steps. (d) Direct capacitor for Transformer no load losses 7.5 KVAR with TPN MCB 25 AmpsNote :-(i) The APFC panel and all connected items mentioned shall be of the same make. (ii) The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification, shall be deemed to be included unless specifically excluded. The equipment shall conform in all respects to high standards of engineering design and workmanship and shall be capable of performing in continuous operation. |
| 63 | Material & labour for providing Earthing complete with GI earth plate electrode 60 x 60 x 0.6 cms thick burried directly in ground (earth plate not less than 2.25 mtr deep below normal ground level) with top edge of the plate at a depth not less than 1.50 mtrs below normal ground level connected to GI strip earth lead 32 x 6 mm Flat by means of bolts, nuts and twin washers made out of galvanised iron or steel all as shown in electrical plate No. 5 of SSR Part I and connected to to earth test point all as specified and as directed including provisioning of protection pipe 40 mm dia bore, watering pipe with funnel and PCC Pit with RCC cover, testing on completion and submissin of test report to the department, complete all as specified and directed by Engineer-in-Charge. |
| 64 | Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade 0f size 95 Sqmm 3,5 core laid in trenches, floors, ducts passing through pipe for road crossing etc complete all as specified and directed by Engineer-in-Charge. |
| 65 | Supply only 5 in 1 digital quality meter to measure PH, EC,TDS,Salt & Temp with USB cord for charging & voice guided results and LED display for measurement,designed to endure water proof and dustproof build IP 65complete all as specified and directed by Engineer-in-Charge. |
| 66 | Material and labour for attending repair and rectification of leakages in water main pipe lines of dia ranging from 150mm to 300mm including sluice valves, non-return valves (NRV) and connected fittings by excavation, dewatering, cutting, dismantling defective portion, replacing nuts, bolts, rubber insertion, gland packing and other minor accessories required for smooth functioning of valves and pipe lines complete all as specified and as directed.The work shall also include minor repair to valves, tightening of joints, leakage rectification, refixing, testing and commissioning of pipe line system, including restoration of the disturbed surface complete. The contractor shall attend complaints/breakdowns at any time as directed by the Engineer-in-Charge and complete the work satisfactorily. Note Major replacement of pipe sections, valves and specials shall be measured and paid separately. |
| 67 | Material & labour for Servicing of ACB (Air Circuit Breaker)Material and labour for servicing of Air Circuit Breaker (ACB) by taking necessary shutdown, racking out the ACB from panel, opening and cleaning of internal components, removal of carbon deposits from contact strips/contacts using suitable electrical cleaning chemical spray, checking wear and tear parts, greasing of moving/mechanical parts with approved lubricant, tightening of terminals and connections, checking of tripping mechanism, spring charging arrangement and insulation condition, reassembling, testing and commissioning complete all as specified and as directed. The work shall include functional testing of ACB after servicing and ensuring smooth operation of breaker in all respects, complete all as specified and directed by Engineer-in-Charge.. |
| 68 | Supply and fixing digital potable chlorine meter with LED display to measure chlorine level of water from 0 to 5 PPM ,with 1.5V battery AAA type power source,response time < 5 seconds,with memmory function stores and recall options complete all as specified and directed by Engineer-in-Charge.(Make Aquasol Digital or any equivalent model ) |
| 69 | Dismantling and taking down old unsv LT Panel and Supplying, installing, testing & commissioning indoor type cubical panel board outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform with nut and bolts, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Aluminium bus bar of 200 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :--(Make : Hanson, Universal, DV Electromatics)a) 4 Nos bus bar of equal size made out of Aluminium strip of suitable size with PVC insulated coloured heat shrinkabal type sleeves, of rating 200Amps, mounted on non cracking resin type insulators - 01 Job |
| 70 | b) MCCB TPN 100 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection 01 Nos (Incoming)c) MCCB TP 63 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection 03 Nosd) In built Star Delta starter suitable for 10 HP motor. 03 Nos with relays.e) Under voltage, over voltage ,over load relay,phase sequence corrector - 01 Jobf) Interconnection of MCCBs to Busbar with AL strip of suitable size with PVC insulated colour coaded heat shrinkable type sleeves - 1 Jobg)RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nosh)Digital Ammeter of range 0-100 A, auxiliary voltage 230 volts with selector switch -02 Nosi) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 Noj)Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cable lugs, sleeves, cable glands etc complete |
| 71 | Supply,installation,commisioning and testing of centrifugal pump of 10 HP with CI Impellor, CI casing, SS shaft capable to handle rough water having 1200 LPM at effective head of 30 Mtr coupled with squirrel cage induction motor IEC3 7.5 KW 3 phase 415 volts TEFC type minimium 80% efficency coupled to driver rating 10 HP squirrel cage induction motor 1475 RPM 3 Ph 415 volts 50 Hz as as per manufacturer design with all standard fixing coupled through flexible coupling to be connected with suction and delivery side + coupling and base plate including taking out UNSV pump of same capacity complete all as specified and directed by Engr-in-Charge. Note :(i) UNSV Pump & motor should be the property of the department Loading/unloading & transportation charges from site to MES store yard shall be deemed included in the quoted rates. (ii) Any fabrication work reqd for fixing the pump shall be deemed included in the quoted rates. |
| 72 | Supply and fabricating of header by MS ERW pipe of bore 200 mm having wall thickness 6 mm with permissible tolerance + 10% conforming to IS-3589, ISI marked, in 3.5 meter long with welded flanges, MS flanges not less than 24 mm thick on both ends closed with end plates including provision of 02 nos inlets (2x 80 mm ) from delivry side and 04 outlets from distribution side ( 02 x 80mm, 01 x 150mm, 01 x50 mm, dia MS pipe , 6 mm wall thickness with not less than 22 mm thick MS welded flanged ends including paint with two coat of synthetic enamelled paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 73 | Material & labour for electromagnetic flowmeter signal converter with gapichal led display to operate 250VAC .4-20mA with IOT Device,flange type to measure the flow of liquid at maximum temp 180 degree Celsius, DN 80 complete all as specified and directed by Engineer-in-Charge. |
| 74 | Material & labour for electromagnetic flowmeter with signal converter with gapichal led display to operate 250VAC .4-20mA with IOT Device,flange type to measure the flow of liquid at maximum temp 180 degree Celsius, DN 150 complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply & fixing micro processor based turbidity meter of range 0 to 1000 NTU with LED display ,power source 220 V + 10 V AC,50 Hz with test tube set of three and operating mannual, complete all as specified and directed by Engineer-in-Charge. |
| 76 | Supply only 0-Tolidine reagent (500 ml) for chlorine estimation with four nos chloroscope for various pump houses complete all as specified and directed by Engineer-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |