| 1 | Demolition of brickwork or stone boulder masonry built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed. |
| 2 | M&L for demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provied for complete all as specified and directed |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 4 | Excavation in trenches n.exc 1.5 m wide & n exc 1.5 m in depth for foundation etc or for shafts, weils, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/ disintegrated rocks as specified & as directed by Engineer-in-Charge. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/ disintegrated rocks, complete all as specified. |
| 6 | Removing excavated material to a distance exc 500mtr and not exceeding 1.5 Km and depositing outside MoD land complete all as specified and directed. |
| 7 | M&L PCC M-10 (Nominal Mix) 1:3:6 Type C-2 using 40mm graded stone aggregate in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 8 | M&L for RCC M-30 design mix (20mm graded aggregate) for Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs all as specified & directed by Engineer -In-Charge |
| 9 | M&L for RCC M30 design mix (20 mm graded aggregate) for Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 10 | M&L for RCC M30 design mix using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 11 | 11 M&L, Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and directed by Engineer-in-Charge. soffits (if any) of foundation and plinth beams; and similar work, vertical or to batter etc on fair finished surfaces all as specified & all as on fair finished Surfaces. |
| 12 | M&L, Formwork to sides and soffits of floor or roof beams, beam haunchings, girder, bressummers, RCC bands, lintels, cantilevers, shelves including sup- ports, overhangs on fair funished surfaces etc. also splays between floors and beams, etc. all as specified & all as directed by Engineer-in-Charge. |
| 13 | M&L, Formwork to sides of pillars, posts, struts, piers, columns and stanchions on fair finished surfaces all as specified & all as directed |
| 14 | M&L CRS TMT bars 10 mm dia & over cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends & binding with & including mild steel wire (not less than 0.9 mm dia) or securing with clips quality conforming all as specified & as directed by Engineer-in-Charge. |
| 15 | M&L for CRS TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 16 | M&L, Pre-cast cement concrete block masonry type C1 (1:3:6) using 20mm graded stone aggregate set in CM 1:4 with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and directed. |
| 17 | Providing Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in copings etc and Cum like including weathering slightly rounded or chamfered angles and throating as directed. |
| 18 | M&L, Rendering 15 mm thick on fair faces of brick, block masonry or concrete surfaces with in CM 1:4 on wall with water proofing component all as specified & directed. Note: WPC measured and paid seperately |
| 19 | Supplying & applying integral waterproofing compound all as specified & as directed by Engineer-in-Charge |
| 20 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement/ chalk whiting as primer complete all as specified and directed. |
| 21 | S& F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into. Kg spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified |
| 22 | S&F mild steel rolled section Fe-410-W(Gde E-250), quality 'A' as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. complete all as specified |
| 23 | S&F bitumen dip concertina coil punched tape 2.60mm dia high tensile steel spring steel wire dia of coil 610mm, when stretched the length shall be 6m in one coil and tied to barbed wire with and inel provision of steel slips @ 5 clips spiral in one row complete without coating complete all as specified and directed. |
| 24 | S&F in repairs galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed by Engineer-in- charge.(each line wire to be measured) |
| 25 | S & F for framed work such as grills, gate, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tank and similar works conforming to Fe-410-0 of Fe-310-0. |
| 26 | M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 27 | M&L for geofabric filter having opening size less than 75mm and permeability more than 15 lit/sqm/sec to be laid above the seabed with specified gradient complete all as specified and directed. |
| 28 | M&L for 0.15m thick nylon/gunny bags filled with stone grit (5mm size) to be laid in required gradient above the geofabric filter complete all as specified and directed. |
| 29 | M&L for 50-100 kg boulders granite stones (50% more than 75 kg) laid for a thickness upto 0.60m above the stone grit packed gunny/nylon bags complete all as specified and directed. |
| 30 | M&L for 500-1000 kg boulders granite stones (50% more than 750 kg) laid for a thickness upto 1.30m above the 50-100 kg stone boulders complete all as specified and directed. |
| 31 | M & L for 7 meter long dipped galvanised octogonal pole with top A/F 70 mm bottom A/F 155mm made out of 3mm thick HT sheet along with base plate of size 260x260x16mm including 1500mm long single arm bracket made out of 48mm dia GI pipe and M20x700m long 'J' type EN8 grade foundation bolts along with template including the following:(a) MCB SP 6A 230V, 10KA mounted on 3mm thick hylem sheet - 01 No.(b) 4 way connector bolt along with locking arrangement weather prooof and water proof control space.Note:-(a) The rate quoted deemed to be include the cost of 50mm PVC pipe from cable trench to centre of the pole concrete and 'J' type EN8 grade foundation bolts & Base foundation.(b) The rate quoted deemed to include the cost of connection of incoming and outgoing cable in new octagonal poles through PVC pipe including taking out loop extending upto junction box connecting complete all as specified and as directed. (c) Base foundatic n designed as per OEM/ Manufacure drawing. |
| 32 | Supply and fixing of new generation energy saving and environmental friendly long life LED security light 90W, made up of pressure die cast aluminium housing with high power LED as lighting sourse and lens embedded PC cover having Top Opening separate driver with IP 66 protection complete in pole/post/wall position by connecting the electrical conrection and tightening the nut,bolts and clamps and all as specified and directed by Engineer-in-Charge |
| 33 | Supply and fixing of new generation post top energy saving er vironmental friendly, long Each 2.00 life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LED as light sourse Coral (opal) - IF65 suitable for pole dia 76 mm with 25 watt LED lamp complete all as specified and d rected by Engineer - in - Charge. |
| 34 | Supply and fixed of hot press moulded SMC junction box sme base and smc door door fixed with no night side sintex box of size 280 x 200 x 100m Cat No GS-JB- 2520 with 6 Amp MCB SP. Bus Bar power connector for RYB N fiked on epoxy base with the help of MS nuts bolts and MS clamps-2 Nos of size 40mm X 5mm thick including fixing arrangement on pole complete all as specified and directed. |
| 35 | Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized R steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4.0 core complete all as specified and directed. |
| 36 | 6 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4 sq mm,3 core, 1100 Volts grade complete all as specified and directed. |
| 37 | Excavation in trer ches n.exc 1.5 m wide and n.exc 1.5 m deep and getting out hard/dense soil for taking out/laying of UG cable LT of any size complete all as specified and as directed. |
| 38 | 8 Returning and filling in trenches incl spreading, levelling watering and raming in layer Cum n.exc 25 cm complete all as specified and directed. |
| 39 | 9 Removing of excavated mtrls n.exc 50 m and depositing where directed at a level n.exc Cum 1.5 m above the starting point. |
| 40 | Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and pla n surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 40 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. |
| 41 | M&L for earthing complete with galvanized steel earth plate electrode of size 600 x 600 Each 2.00 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI strips 25 x 4 mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia Gl pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick. RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrica plate No.3 of SSR Part-I all as specified and directed. |
| 42 | M & L earthing complete with galvanced steel earth plate electrode of size 600: 300 Each on thick buried directly in ground to a depth not less than 2 25 mtr below the more ground level with top edge of earth plate not less than 150 mtr below the normal ground level and connected to GI wire of dia 4.0 mm by means of nut, bolt & washer and protected by 40min dia GI pipe light grade and watering pipe of 20mm dia Gl pipes light grade and connected to earth test point including necessary excavationn, earth work. PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No.3 of SSR Part-1 all as specified and directed. |
| 43 | Supply, installation, testing & commissioning floor mounted factory made cubical LT panel out door type double door suitable size made of 3.15 mm thick CRCA sheet, CPRI approved IP-54 duly painted with epoxy based powder coated paint, including base channel, interconnection control wiring name plate for each switch gears, danger plate, earth bus bar, as per IS 5039. comprising of compartments for each feeder and its accessories, cable gland with hinged door, bus chamber with bolted door etc dust & vermin proof construction attractive powder coated Panel internal wiring for control circuit with copper cable 2.5 Sqmm. comprising with following including necessary PCC and excavation work all as specified and directed :-(a) Aluminium bus bar 200 Amps TPN-1 set(b) MCCB 4 Pole 63 Amps., 25 KA - 01 No. (incomer)(c) MCCB TPN 63 Amps.. 10 KA - 02 No. (outgoing)(d)Power Contactor 3 Pole 63 Amps -1(e) Timer switch 415 Volts 20 Amps- 01 No.(f) Digital Ammeter with CT's and Selector switch-01 Set(g) Digital Voltmeter with SS-01 Set(h) Indicating lamp LED Type-RYB-01 Set (i) Digital Multifunctional Meter - 01 Set Please Enable Macros to View BoQ information |