| 1 | Taking down shutters of any description exc. 1.00 Sq.m and n.exc. 2.00 Sq.m each. |
| 2 | Taking down Chowkats with shutters (Without taking off shutters from frame) area exc 1.5 Sqm but not exc 4.00 Sqm |
| 3 | Taking down Chowkats with shutters (Without taking off shutters from frame) n exc 1.5sqm each complete |
| 4 | S&F of 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed |
| 5 | S & F Solid PVC Door Frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with M S Square tube,supplying and fixing in opening as per manufacturers instructions and as directed by Engineer-in-Charge. |
| 6 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails. M S tube for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS fram welded/sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement. |
| 7 | S&F 35mm thick plain factory made framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply The size of rail and stile as per IS 1003 (Part-I Kiln seasoned and chemically pressure treated complete all as specified. |
| 8 | S & F, 35mm thick, 2nd class hardwood glazed & skelton shutters, open rebated & prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a). |
| 9 | S&F 35 mm thick flush shutters , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 10 | M&L Preparatioin of new wooden surfaces of any description over 10CM width or girth and applying two coats of synthetic enamel paint over a coat pink primer.complete all as specified and as directed. |
| 11 | S&F 100mm long MS Medium weight Butt hinges cold rolled , fixed complete all as specified and as directed. |
| 12 | S&F 100mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 13 | S&F 150mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 14 | S&F 200mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 15 | S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified and as directed.. |
| 16 | S & F 300mm long MS ordinary rat tail rod pattern springs inc. roller & roller plate complete all as specified and as directed. |
| 17 | S & F 150mm long floor door stopper of aluminium alloy boly and tongue anodised with hard steel spring fixed in floor complete all as specified and as directed. |
| 18 | S & F Brass Mortice lock 4 leavers vertical type size 100mm complete all as specified and as directed.. |
| 19 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed in panels of joineries with stainless steel wire staples complete all as specified and as directed. |
| 20 | Taking down steel/aluminium /windows, /doors, of any size with/without frame and shutters and including with all connected accessories complete. |
| 21 | S & F Powder coated Aluminium anodized frame work for door / windows / ventilators with one or more rebates including joining heat for fixing etc complete all as specified |
| 22 | S&F Powder coated anodied aluminium window and ventilator shutter ,side hung type without sash bars aluminium sections weighing 0.55 kg/m including necessary joining cleats ,glazing clips rubber packing anodised aluminium snap beading ,screws,anodised aluminium fitting such as peg stays 150 mm long (1 no),hinges typeB-21 100mm long (2 nos) suitable handle (1no) complete all as specified. |
| 23 | S & F Powder coated anodized door shutters, aluminium section weighting 0.55 Kg/M including necessary joinging cleats, galzing clips, ruber neoprene pakcing handles 2 Nos in each door, hinges anodised aliminium snap beading screws etc, complete all as specified |
| 24 | S&F Aluminium door closure extruded section body hydraulically regulated disignatin No 3 universal type suitablefor door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed all as specified and directed. |
| 25 | S&F 5.5 mm thick sheet Glass ground or obscured or frosted on one side selected quality and glazing with oil putty in square exc 0.50 Sqm in each pane complete all as specified and directed by Engr-in-charge |
| 26 | S & F prelaminated particle board 9mm thick interior grade pre laminated one side with decorative choice lamination and other side balancing white lamination fixed with screws. |
| 27 | S&F 4mm thick Figured glass, pin head type and glazing with oil putty in square not exceeding 0.50 Sqm in each pane all as specified and as directed. |
| 28 | S&F Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter, jointed internally with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified & as directed by Engineer-In-Charge. (Note ; 4mm thick sheet glass and stainless steel wire mesh will be measured and paid separately) |
| 29 | M&L for preparation of new steel or iron surface of any description over 10cm in width or girth,not otherwise described applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 30 | S&F 4 mm thick sheet Glass ground or obscured or frosted on one side selected quality and glazing with oil putty in square exc 0.50 Sqm in each pane complete all as specified and directed by Engr-in-charge |
| 31 | S & F 18 /19 mm thick Block boards, grade 1 quality,Exterior grade,decorative type with decorative face veneer on both sides, fixed with screws to timber frame-work, fixed with screws to timber frame work , all as specified and as directed. |
| 32 | S & F Extra over rates of block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails all as specified. |
| 33 | S&F 75mm long MS Medium weight Butt hinges cold rolled , fixed complete all as specified and as directed. |
| 34 | S & F 30mm width flaps of Continuous (piano) hinges,mild steel, bright finish or electro galvanised in repairs all as specified and as directed. |
| 35 | S & F 100 mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and as directed |
| 36 | Petty repairs to joinery works such as easing of doors, windows, kitchen cabinets , refixing builder hardware gauge etc incl petty repair items / materials like screws, nails , washers, grease etc and all kind of machine works i.e welding, cutting, bending, dilling , grinding, polishing etc of various location under akash vihar to the satisfaction of user and rectifying other misc minor carpentary works assigned by the Engneer In Charge. Note : (i) Replacement of builders hardware if required shall be measured and paid separately.(ii) Contractor or his authorised representative will collect such type of complaints from AKASH VIHAR complaint cell of AGE B/R - I at 8.30 AM on daily basis except sunday /Holiday. No extra payment shall be made on account of collection of complaint.(iii) Complaint must be attended within 24 hours of receipt of complaint else recovery of Rs. 100/-per complaint/ per day will be Charged strictly. |
| 37 | S&F in repair door closure extruded section body hydraulically regulated disignatin No 3 universal type suitablefor door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed all as specified and directed. |
| 38 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed in panels of joineries with stainless steel wire staples fixed in repair complete all as specified and as directed. |
| 39 | M &L Welding in repairs to the thickness exc 6mm but n. exc 9mm steel section, welded length n. exc 2.5 cm in each length etc all as directed by Engineer-in- charge. |
| 40 | Hacking out old broken glass ( any thickness, size, quality or description) from metal frame frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones including supply and fix 4mm thick sheet glass ordinary quality in square or n. exc 0.5 sqm each pane up to 6th floor complete all as specified and directed by Engr-in-charge. Note : Extra cost will not be paid for scaffolding works & safety precaution of workers. |
| 41 | Hacking out old broken glass ( any thickness, size, quality or description) from metal frame frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones including supply and fix 4mm thick sheet glass ordinary quality in square or exc 0.5 sqm each pane up to 6th floor complete all as specified and directed by Engr-in-charge. Note : Extra cost will not be paid for scaffolding works & safety precaution of workers. |
| 42 | S&F in repairs 150 mm aluminium anodised barrel tower bolts, of extruded section with ISI mark all as specified and directed |
| 43 | S&F in repairs 200 mm aluminium anodised barrel tower bolts, of extruded section with ISI mark all as specified and directed |
| 44 | S&F in repairs 300mm aluminum anodised sliding door bolts, with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast alluminium alloy with ISI mark complete all as specified and directed. |
| 45 | S&F in repairs mild steel butt hinges of 75 mm size medium weight cold rolled by welding to existing frame complete all as specified and directed |
| 46 | S&F in repairs mild steel butt hinges of 100 mm size medium weight cold rolled by welding to existing frame complete all as specified and directed |
| 47 | S&F in repairs 150 mm extruded aluminum alloy handles, fabricated type anodized complete all as specified and directed |
| 48 | S&F in repairs 100 mm long safety type aluminium anodised hasp and staple with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 49 | S&F in repair floor door stopper of aluminium alloy body and tongue, overall length of cover plate 140 mm anodised with hard drawn steel spring, fixed in floors complete all as specified and directed. |
| 50 | S&F in repair mild steel helical door spring 300mm ordinary rat tail rod pattern springs including roller plate complete all as specified and directed. |
| 51 | S & F in repair Brass Mortice lock 4 leavers vertical type size 100mm complete all as specified and as directed.. |
| 52 | S&F in repairs of powder coated curtain rod brackets suitable for fixing 1\\" dia size curtain rail, fitted over wooden round gatta, complete etc, all as specified and as directed. |
| 53 | S&F in repairs 20 mm dia anodised aluminium anodised powder coated tubular curtains rod including fixing brackets complete all as specified and directed. |
| 54 | Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in internal and external surfaces of man holes, septic tank, filter bed etc incl removing of debries complete all as specified and directed. |
| 55 | M/L Rendering 15mm thick in CM 1:4 on fair faces of brick or concrete and finishing the surfaces even and smooth without using extra cement in patch work at various places upto 8th storey incl necessary formwork complete all as specified & directed. |
| 56 | M&L Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing even and fair. complete all as specified and directed. |
| 57 | M&L Rendering 10mm thick in cement mortar 1:3 as in ceiling concrete surfaces including finishing even and fair. complete all as specified and directed. |
| 58 | M & L for applying three coats of white wash on wall including preparation of newly plastered surfaces complete all as specified and as directed. |
| 59 | M & L for applying two coats of oil bound distemper on walls over a coat of primer including preparing newly plastered wall surfaces complete all as specified and as directed. |
| 60 | M & L for applying three coats of white wash on ceiling including preparation of new plastered surfaces complete all as specified and as directed. |
| 61 | M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified |
| 62 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar , incl all quions, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 63 | Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in hard/dense soil all as specified and directed. |
| 64 | Returing, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm, hard/dense soil |
| 65 | Removing building materials etc. to a distance of 5 Km out side MoD/Unit land including loading, unloading and stacking at the destination etc. complete all as direction of Engineer-in-charge, |
| 66 | M & L for Walling of squared rubble,regular coursed, well bonded,bedded and solidly hearted masonary built in CM 1:6 including hammer dressing all as specified and directed. |
| 67 | All as per above Item No 66 but except material , complete all as specified and directed. |
| 68 | Extra over stone masonry for hammer dressing to face stones and dressing offace beds and joints as specified, of random rubble walling, uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface not exceeding 20 mm complete for lime or sand stones, complete all as specified. |
| 69 | M&L Keyed pointing to random or polygonal rubble stone masonry, uncoursed or brought upto courses in cement mortar 1:4 complete all as specified. |
| 70 | M&L for flush pointing to squared rubble masonry, uncoursed or brought upto courses in CM 1:4, complete all as specified and directed by Engineer - in - charge. |
| 71 | Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width Type C1 1:3:6 (20 mm graded aggregate ) and setting in mortar CM 1:6 but except Blocks etc. complete. |
| 72 | Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width Type C1 1:3:6 (20 mm graded aggregate ) and setting in mortar CM 1:6, complete. |
| 73 | M&L for concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete all as specified and directed. |
| 74 | Material and Labour for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, mud stops, benching, water tank platform etc.on roof, chajja weathering, slightly rounded or chamfered angles and throating etc. including necessary form work complete as directed. |
| 75 | Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc |
| 76 | Dismantiling wrought iron or mild steel work of any description not otherwise provided for etc comoplete all as specified. |
| 77 | S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) coforming to Fe 410 -W (Gde E-250) Quality -A all as specified and directed. |
| 78 | S&F for Posts and Struts in fencing including cutting tops to shape as directed drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 79 | Dismantling fencing wire mesh, any type |
| 80 | Supply only chain link MS galvanised fencing any size or type , complete all as specified and directed by Engineer - in - charge. |
| 81 | Fixing only chain link fencing including line wires,, any mesh, size and type to any type of standards, rails, straining bolts, welding work required etc. including provision of winding wire, complete all as specified and directed by Engineer - in - charge. |
| 82 | Dismantling barbed wire fencing of any description |
| 83 | S & F for Galvanised 2 strand, steel barded wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of strandard rails straning bolts, incl, securing or tying at crossings with and provision of galvanised mild steel, wire staples or steel pins etc complete all as specified and directed. (each line wire to be measured separately). |
| 84 | Fixing only Galvanised 2 strand, steel barded wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of strandard rails straning bolts, incl, securing or tying at crossings with and provision of galvanised mild steel, wire staples or steel pins etc complete all as specified and directed. (each line wire to be measured separately). |
| 85 | Supply and Fix in repair for zinc coated concertina coil of thickness 2.50 mm of core wire and 0.5 mm thick cold rolled carbon strip (dia approx 610 mm that covering 6 mtr length and 50 spirals) having weight not less than 8.00 Kg per coil all as directed. |
| 86 | Material and Labour for preparation of Old decorated surfaces of Walls including brooming down or steel wire brushing, scrapping down smoke, soot, module, moss and efflorescence salt, etc and applying Two coats of cement base paint Complete all as specified and directed. |
| 87 | Excavation in trenches n.exc. 1.5 m wide and exc. 1.5 m and n. exc. 3.0 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in hard/dense soil all as specified and directed. |
| 88 | Returning, filling in with approved soil obtained from excavation including spreading levelling, watering and well ramming in layers n.exc. 25cm thick all as specified and directed.. |
| 89 | Removing the excavated soil to a distance exc 250 m and n.exc 500 m and depositing where directed all as specified. |
| 90 | Demolition and breaking up drain pipes(salt glazed ware,AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed for 150mm dia pipe all as specified and directed. . |
| 91 | All as per item no 94 above but 200 mm dia pipe. |
| 92 | M&L Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 150mm dia drain pipe all as specified and directed. |
| 93 | M&L Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 200 mm dia drain pipe all as specified and directed. |
| 94 | M&L for SWG drain pipe grade 'A' of 150 mm internal dia laid in trenches and jointed in cement mortar 1:1 all as specified. |
| 95 | M&L for SWG drain pipe grade 'A' of 200 mm internal dia laid in trenches and jointed in cement mortar 1:1 all as specified. |
| 96 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting ou existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm dia SWG pipe all as specified and directed. |
| 97 | Description All as per item no 96 above but 225 mm dia. |
| 98 | M&L for Cleaning of all blockage of Nahani trap/ floor trap, bottle trap, gully trap P or S traps of WCs, 100/75mm dia CI pipes upto 1st MH, CI/SGSW pipes between gully trap and 1st MH, CI/PVC 'T'/ Door bends etc to maintain internal sewage system and any type of sewage line ie branch sewer line, main sewer line etc, manholes of any section and depth, any situation by way of cleaning/disludging manholes by using any type of manually,mechanically or by way of any other suitable means including foreign materials as well as rodding of sewer lines and between successive from block manholes where required and ordered by Engineer-in-charge and keeping the sewage line functional cleaning trap,water closet,soil waste/vent pipe,gully traps upto final drop out let into septic tanks or central sewage system treatmenting in other adjoining Zone/Area of into sewage well (working in foul condition with taking precautionary measures) equipment as required or applicable all as specified and directed. manholes of any size and depth and removing the sludge/material and depositing outside the MOD land complete all as directed by Engr-in-Charge.NOTE : (i) Sufficient number of persons working under the area Akash Vihar (AF) camp cell in charge JE in all working days from 08.30 Hrs to 16.30 Hrs with necessary T&P. (ii) Complaint must be attended within 24 hours of receipt of complaint else recovery of Rs. 100/-per complaint/ per day will be Charged. (iii) The cost of transportation (to and fro) and other necessary T&P, flexible rods, wires, bamboo sticks and other equipment and safety gear shall be arranged/ bought by contractor to complete the job and no extra cost cost shall be paid to the contractor in this effect.(iv) Apprroximate length of sewage line is 1800 Rm.(v) Apprroximate No. of MH IS 400Nos. (vi) Apprroximate No. of Md Accn is 460 No. and OTM 20 No. |
| 99 | Cleaning and de-sludging of existing septic tanks / deep manholes up to 4 metre deep including taking out sewage water / sludge in any form alongwith all other foreign materials by mechanical equipment or manually or by way of any other suitable means including removal of sludge and other foreign materials out side the MD land by any means complete(working in foul condition) all as specified and directed. |
| 100 | Excavation in trenches for exposing the sewage line and breaking SGSW pipe horizontally on top to help cleaning the sewer line from Manhole to the location where the SGSW pipe is broken and covering the broken portion of SGSW pipe from the top and sealing the opening in CM (1:3) including returning filling and ramming in trenches with excavated earth and disposal off surplus earth to a distance not exceeding. 50 m complete all as directed by Engr-in-charge (irrespective of depth and type of soil). |
| 101 | Demolition of PCC around floor trap and dismantling existing floor trap and cleaning the blockage of pipe from floor trap to gully trap and supply and fix PVC floor/Nahani trap in existing pipe and embedding in CM (1:1) including lowering or raising with vertical piece with PVC pipe for jointing trap and fixing gratings at true level of floor up to 6th floor complete all as directed. |
| 102 | M & L for Pre-cast cement concrete block masonry type B1 1:3:6 (20mm agg) with solid blocks, exc 10 cm in width and setting in mortar 1:6 complete. |
| 103 | Material and Labour for Cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping, benching including finishing the concrete surface even & smooth without using extra cement. |
| 104 | Material and Labour for forming fair finish to channel in manholes using extra cement. |
| 105 | Material and Labour for rendering 15mm thick in CM 1:4 on brick or cement concrete surfaces & finished even and smooth without using extra cement. (WPC will be meausred and paid separately) |
| 106 | Supply only water proofing compound. |
| 107 | Material and Labour for PCC (1:3:6) type C2 using 40mm graded stone aggregate in foundation. |
| 108 | Demolition of reinforced cement concrete of any descripition and any position not other wise specially provided all as specified and as directed. |
| 109 | M&L Precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate ) for manhole cover & septic tank covers slabs etc including necessary form work and set in CM (1:4) all as specified and directed.. Note:- Reinforcement will be measured and paid seperatel |
| 110 | S/F MS TMT bars 10 mm dia and over for reinforcement etc, cut to length, bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed. |
| 111 | S/F MS TMT bars 6mm to 8mm dia and over for reinforcement etc, cut to length, bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 112 | Taking down rain water pipes / Drain pipes/ Soil waste pipes of any description and any size any pattern incl all fittings heads, shoes bends etc all as specified and as directed. |
| 113 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls bore of the pipe 110 mm upto 6th floor all as specified and directed. Note: Necessary Safety precautions / Scaffolding for workers are to be taken by the contractor and No Extra cost will be paid for the Scaffolding and safety precautions of workers. |
| 114 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls bore of the pipe 75 mm upto 6th floor all as specified and directed. Note: Necessary Safety precautions / Scaffolding for workers are to be taken by the contractor and No Extra cost will be paid for the Scaffolding and safety precautions of workers. |
| 115 | S&F PVC bends of 110 mm dia with access door complete all as specified and directed. |
| 116 | S&F PVC bends of 75 mm dia with access door complete all as specified and directed. |
| 117 | S&F PVC(SWR) junction double,(double T),equal or unequal. 110 mm dia with access door.all as specified and directed. |
| 118 | PVC (SWR) branch piece, single(singleY) equel or un equel fixed to 110mm bore of pipes with access door all as specified and as directed. |
| 119 | PVC (SWR) branch piece, double(double Y) equel or un equel fixed to 75mm bore of pipes with access door all as specified and as directed. |
| 120 | S&F PVC (SWR) vent cowl 110 mm dia complete all as specified and directed. |
| 121 | S&F PVC (SWR) vent cowl 75 mm dia complete all as specified and directed. |
| 122 | S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement in repair complete all as specified and directed. |
| 123 | S&F for PVC (SWR) gully trap of 125/110 mm dia set and jointing wilh solvent cement complete all as specified and directed. |
| 124 | S&F straps, supports or stays for rainwater, ventilating pipes, including bolts, if required with MS Flat Iron brackets for fixing PVC (SWR) pipes of 110mm dia single socketed in any length with @ 2.0 mtr interwell fixed to walls complete all as specified and directed. Please Enable Macros to View BoQ information |