| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /disintegrated rock complete all as specified and directed. |
| 2 | All as per item No 01 for each additional 1.5m or partthereof in depth beyond the first 1.5 m complete all as specified and directed. |
| 3 | Returning, filling in, soft /disintegrated rock including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed. |
| 4 | Removing excavated material soft /disintegrated rock n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | M&L for spread fine river sand in trenches complete all as specified and as directed. Note: For measurement purpose, punned down thickness shall only be taken. |
| 6 | Supply and laying cable protection bricks, common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed. |
| 7 | M&L for PCC (1:4:8) Type D2 (using 40 mm graded aggre-gate) as in foundations,of pole/stay including form work complete all as specified and directed. |
| 8 | M&L for PCC (1:3:6) Type C1 (using 20 mm graded aggre-gate) as incoping of poles stud including form work complete all as specified and directed. |
| 9 | Dismantling and taking down existing unserviceable / deshaped / worn out LT / HT steel tubular / PCC pole of any shape, size & height including demolition of existing PCC foundation with and including MS cross arms, insulator etc. complete all as specified and directed.Note :- PCC pole, corss arms and insulator obtained under this will be consider for credit schedule. |
| 10 | Dismantling and taking down bend/damaged mild steel work such as cross arms, bracing, supported, clamps & back plates etc complete all as specified and directed. |
| 11 | Dismantling and taking out of old existing unserviceable insulators of any description and in any position complete all as specified and as directed. |
| 12 | Dismantling of existing unserviceable stay assy any type/size from its stay rod, cutting stay rod (above ground portion ) including stay GI wire, dismantling MS clamps, nuts, bolts, GI stay bow loop insulators etc including GI wire complete all as specified and directed. |
| 13 | Dismantling of ACSR conductor of any type complete all as specified and directed. |
| 14 | Disconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 100mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed. |
| 15 | S&F of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP 55 (11.0 meter long) as per IS-2713 including painting two coats of aluminium paint over one coat of red oxide primer including 4 Nos band/straps with yellow and black colour in alternate way (250mm wide each) aluminium paint two coat at a distance 300mm from plinth block and marking pole nos with black paint including tarring one coat on steel surface embedded in concrete complete all as specified and directed. Note :- Necessary earth work and excavation, PCC in foundation 1:4:8 type D-2, using 40mm graded stone aggregate and PCC 1:3:6 type C-1, using 20mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50mmeasured and paid sepearately |
| 16 | M&L for dismantling of old unserviceable lightening arrester and supply and fix new lightening arrester non liner type confirming to IS No 3070 part I complete with all fittings, transmission class discharge capacity 12KV/10 KA suitable for 11 KV including making connections with over head line with ACSR conductor complete on poles all as specified and directed. |
| 17 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic aluminium paint complete all as specified and directed. |
| 18 | Supply, installation. connecting electrically & commissioning in replacement HT 11 KV outdoor type switch air break, gang operated, tripple pole mounted horizontal or vertical mounting fixed type complete with insulators 15 Nos 200 Amps rating and steel frame mechanically operated mechanism consisting of operating rod 25mm bore light grade GI pipe of suitable length worked from ground level and with locking arrangement flat iron clamp 50mmx6mm including MS channel of suitable size length for fixing GOD including bolts, nuts and washer complete all as specified and directed. |
| 19 | M&L for galvanized steel wire 3.15/4 mm dia to HT over head line as continuous earth or fabrication of guarding cradles all as required at site complete all as specified and directed. |
| 20 | S&F in replacement of existing unserviceable Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 X 20 cm size complete all as specified and directed. |
| 21 | Supply & Fixing stay assembly complete with all accessories, such as stay plate 300x300x6mm, stay rod 215cm long and 20mm dia with nuts including GI Bow turn buckle etc, all as per Electrical Plate No 1 SSR-2009 Part-I complete all as specified and directed. (Necessary excavation and PCC and one set of stay clamps at top of pole & loop insulator of size 90x140mm porcelain, vitreous, white, brown or green shall be measured and paid seperately) |
| 22 | S&F Galvanised stay wire of size 7/4mm all as specified and directed. |
| 23 | M&Lfor loop type insulator porcelain vitirious porcelain white, brown or green large size with overall dimensions 90 x 140 mm clearence of hole 25.5mm complete all as specified and directed. |
| 24 | Supply and fix disc type polymer Insulator with hardware fitting ball and socket type, 70 KN disc assembly for working pressure 11000 Volts complete all as specified and as directed. |
| 25 | Supply and fix pin type polymer Insulator with hardware fitting ball and socket type, 70 KN for working pressure 11000 Volts complete all as specified and as directed. |
| 26 | Supply, streching and fixing of over head ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. |
| 27 | Restreching only overhead ACSR conductor/earth wire of any size and type comprising of one conductors/wire over steel tubluar poles, incl opening, streching, binding and jointing the conductor to insulator with and incl 14 SWG binding wire and tape the jumper complete all as specified and directed. |
| 28 | M&L for punning of tree branches touching to electric overhead lines with growth around HT overhead lines poles and stay complete to clear span of 2 mtr all around the OH lines poles with all tools and plants as required at site by the contractor including cleaning the area/site. Note (i) Any breakdown of line caused during the punning shall be made good by the contractor without any extra cost (ii) Distance between pole to pole shall be measured as one span. (iii) Only those span will be measured in which trees are alives. |
| 29 | Supply and fixing female contact spring loaded having brass contacts suitable for GOD 200A for working pressure 11000Volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation all as required at site complete all as specified and directed. |
| 30 | Supply and fixing male contact with arching horn having brass contacts suitable for GOD 200A for working pressure 11000Volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation all as required at site complete all as specified and directed. |
| 31 | Supply and fixing copper braided belt 400mm long with MS jumper carrier suitable for GOD 200A for working pressure 11000Volts, galvanised iron bolts, nuts and washers for fixing all as required at site or directed by Engr In charge. |
| 32 | Supply and fix alumn conductor screened with extruded semi conducting compound XLPE insulated of size 70 sqmm 11 KV cut to size all as required for jumpers of HT lines complete all as specified and directed. |
| 33 | M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty ) with alumn conductor, 11/6.35KV grade, suitable for earthed system, with aluminium conductor, 3 core 95 Sqmm complete all as specified and directed. |
| 34 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm complete all as specified and directed. |
| 35 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm complete all as specified and directed. |
| 36 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.complete all as specified and directed.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 37 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 32x6 mm GI strip as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia medium grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 38 | Supply only graded coarse aggregate of nominal size 20mm around indoor/outdoor substation/ 2 pole/4 pole structure boundry complete all as specified and directed. |
| 39 | Labour for laying,spreading and leveling graded coarse aggregate complete all as specified and directed. |
| 40 | M&L for Cutting bushes, levelling the area around E/M installation, sub stations, pole structure etc including surface excavation not exceeding 30 cm deep and avearaging 15 cm deep and getting out roots etc and throw away not less than 50 mtr from the site and making good complete all as specified and directed. |
| 41 | M& L for replacement of Cable lugs with aluminium alloy tubular bimetallic terminals of size 95 Sqmm incl crimping with help of crimping tools complete all as specified and directed. |
| 42 | Excavation in post holes(or similar holes) in soft/disintegrated rock each n exc 0.5 cu m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/disintegrated rock complete all as specified and directed. |
| 43 | M&L for cement concrete 1:2:4 type B2 using 40mm graded stone aggregate as in foundation filling and mass concrete etc complete all as specified and directed. |
| 44 | S&F rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc, (cut to ordinary lengths i.e within 20mm of the length as indicated) in Fe-410W Gde E-250 quality 'B' complete all as specified and directed |
| 45 | M&L mild steel round bars 10mm dia and over of Fe-290(Gde E-165) and over cut to length bent to shape required including provision of binding wire complete all as specified and directed. |
| 46 | S&F 11 to 15mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut with length of bolt exc 5cm but n exc 10 cm long and 11 to 15 mm dia of neck complete all as specified and directed. |
| 47 | M&L for preparation of new steel surfaces of any description over 10cm width or grith and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome primer complete all as specified and directed. |
| 48 | Supply only chain link MS galvanised fencing, any size and type complete all as specified and directed. |
| 49 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc, including provision of binding wire complete all as specified and directed. |
| 50 | S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete all as specified and directed. |
| 51 | Dismantling structural steel work in cluding doors, gates but excluding framed truss etc. complete all as specified and directed. |
| 52 | S&F Rolled mild steel in (Fe-410 W(Gde E-250) quality B) framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging also fastening and fixing complete all as specified and directed. |
| 53 | M&L for prepration of old treated surface of existingsteel tubular pole 11 mtr hight without removing accessories and Preparation surfaces for repainting. Repainting the pole with one coat of alternate black and yellow strips of 30 cm upto height of 1.5 mtr using synthetic enamel. Marking the pole number with black enamel paint. Repainting the remaining pole and iron parts steel cross arms i.e 'U' clamps etc above 1.5 Mtr height by applying two coat of synthetic enamel aluminium paint all as required at site complete all as specified and directed. |
| 54 | M&L for prepration of old treated surface of existing two pole structure steel tubular pole 11 mtr hight without removing accessories and Preparation surfaces for repainting. Repainting the pole with one coat of alternate black and yellow strips of 30 cm upto height of 1.5 mtr using synthetic enamel. Marking the pole number with black enamel paint. Repainting the remaining pole and iron parts steel cross arms i.e 'U' clamps etc above 1.5 Mtr height by applying two coat of synthetic enamel aluminium paint complete all as specified and directed. |
| 55 | M&L for prepration of old treated surface of existing four pole structure steel tubular pole 11 mtr hight without removing accessories and Preparation surfaces for repainting. Repainting the pole with one coat of alternate black and yellow strips of 30 cm upto height of 1.5 mtr using synthetic enamel. Marking the pole number with black enamel paint. Repainting the remaining pole and iron parts steel cross arms i.e 'U' clamps etc above 1.5 Mtr height by applying two coat of synthetic enamel aluminium paint all as required complete all as specified and directed. Please Enable Macros to View BoQ information Compatibility Report for BOQ86480.xls Run on 5/18/2026 10:02 If the workbook is saved in an earlier file format or opened in an earlier version of Microsoft Excel, the listed features will not be available. Significant loss of functionality # of occurrences Version Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear truncated. 3.0 Excel 97-2003 Some cells in this workbook contain data validation rules, which refer to values on other worksheets. These rules won't be saved. 4.0 Excel 97-2003 |