| 1 | Comprehensive Maintenance and servicing to DG set by OEM/ Authorized service centre once in a three month including attending faults on call basis for normal repairs including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery tereminals, adding distilled water checking the oil, coolent levels Auto Manual functions, contact points, timers of capacity 200 & 250 KVA DG set installed at 110 Single officers area Mhow complete all as specified and directed.Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per OEM specifications/ instructions. (iii) The whole servicing shalll be carried out through OEM/ Service engineer whose certificate shall be produced to Engineer-in-Charge. (iv) Proper record & test results of the same shall be maintained as directed. (v) Work shall be carried out at site at different location. |
| 2 | All as per Srl item No. 1.00 but capacity 180 KVA DG set installed at MAP Kodariya. complete all as specified and directed. |
| 3 | All as per Srl item No. 1.00 but capacity 160 KVA DG set installed at MAP Kodariya and HQ MCTE Mess, complete all as specified and directed.. |
| 4 | All as per Srl item No. 1.00 but capacity 125 KVA DG set installed at FCTS Mhow complete all as specified and directed.. |
| 5 | All as per Srl item No. 1.00 but but capacity 100 KVA DG set installed at HQ MCTE, complete all as specified and directed.. |
| 6 | All as per Srl item No. 1.00 but but capacity 62.5 KVA DG set installed at MAP Kodariya, complete all as specified and directed.. |
| 7 | All as per Srl item No. 1.00 but but capacity 30KVA DG set installed at WB-02, WB-27, GC Mess complete all as specified and directed. |
| 8 | All as per Srl item No. 1.00 here-in-before but capacity 15KVA DG set installed at HQ CWE complete all as specified and directed. |
| 9 | Supply only Diesel filter element with 'O' ring suitable for 160 KVA to 250 KVA DG set compete all as specified and directed. |
| 10 | Supply only Diesel filter element with 'O' ring suitable for 125/ 100 KVA DG set compete all as specified and directed. |
| 11 | Supply only Diesel filter element with 'O' ring suitable for 62.5 KVA DG set compete all as specified and directed. |
| 12 | Supply only Diesel filter element as per OEM specification with 'O' ring suitable for 30 KVA and 15 KVA DG set compete all specified and directed. |
| 13 | Supply only air filter element as per OEM specification suitable for 180 to 250 KVA DG set compete all as specified and directed. |
| 14 | Supply only air filter element as per OEM specification suitable for 160 KVA DG set compete all as specified and directed. |
| 15 | Supply only air filter element as per OEM specification suitable for 125 KVA DG set compete all as specified and directed. |
| 16 | Supply only air filter element as per OEM specification suitable for 100 KVA DG set compete all as specified and directed. |
| 17 | Supply only air filter element as per OEM specification suitable for capacity 62.50/ 30 KVA DG set compete all as specified and directed. |
| 18 | Supply only air filter element as per OEM specification suitable for capacity 15 KVA DG set compete all as specified and directed. |
| 19 | Supply only Fan Belt as per OEM specification complete suitable for 180 to 250 KVA DG set compete all as specified and directed. |
| 20 | Supply only Fan Belt as per OEM specification complete suitable for 160 KVA DG set compete all as specified and directed. |
| 21 | Supply only Fan Belt as per OEM specification complete suitable for 125 KVA DG set compete all as specified and directed. |
| 22 | Supply only Fan Belt as per OEM specification complete suitable for 100 KVA DG set compete all as specified and directed. |
| 23 | Supply only Fan Belt as per OEM specification complete suitable for capacity 62.50/ 30 KVA DG set compete all as specified and directed. |
| 24 | Supply only Fan Belt as per OEM specification suitable for capacity 15 KVA DG set compete all as specified and directed. |
| 25 | Supply only Belt as per OEM specification for battery charging alternator complete suitable for 180 to 250 KVA DG set compete all as specified and directed. |
| 26 | Supply only Belt as per OEM specification for battery charging alternator complete suitable for 160 KVA DG set compete all as specified and directed. |
| 27 | Supply only Belt as per OEM specification for battery charging alternator complete suitable for 125 KVA DG set compete all as specified and directed. |
| 28 | Supply only Belt as per OEM specification for battery charging alternator complete suitable for 100 KVA DG set compete all as specified and directed. |
| 29 | Supply only Belt as per OEM specification for battery charging alternator complete suitable for capacity 62.50/ 30 KVA DG set compete all as specified and directed |
| 30 | Supply only Belt as per OEM specification suitable for battery charging alternator complete suitable for capacity 15 KVA DG set compete all as specified and directed. |
| 31 | Supply only Rubber Hose pipe as per OEM specification set for water circuit with clamps complete suitable for 180 to 250 KVA DG set compete all as specified and directed. |
| 32 | Supply only Rubber Hose pipe set as per OEM specification for water circuit with clamps complete suitable for 160 KVA DG set compete all as specified and directed. |
| 33 | Supply only Rubber Hose pipe set as per OEM specification for water circuit with clamps complete suitable for 125 KVA DG set compete all as specified and as directed. Make : (As per existing DG Set Make) |
| 34 | Supply only Rubber Hose pipe set as per OEM specification for water circuit with clamps complete suitable for 100 KVA DG set compete all as specified and directed. |
| 35 | Supply only Rubber Hose pipe set as per OEM specification for water circuit with clamps complete suitable for capacity 62.50/ 30 KVA DG set compete all as specified and directed. |
| 36 | Supply only Rubber Hose pipe set as per OEM specification for water circuit with clamps complete suitable for capacity 15 KVA DG set compete all as specified and directed. |
| 37 | Supply only Engine oil, multi grade premium Genuine oil 20W/ 40 as per manufacturer recommendations in DG sets complete all as specified and directed. |
| 38 | Supply and applying Petrolium Jelly (01 Kg plastic sealed container) complete all as specified and directed. |
| 39 | Supply and filling distilled water for topping up in lead acid batteries complete all as specified and directed. |
| 40 | Supply and filling electrolyte as per OEM specification of suitable specific gravity for lead acid batteries in sealed container complete all as specified and directed. |
| 41 | M&L for Battery leads as per OEM specification of PVC insulated, multistranded, copper conductor of size 70 Sqmm of 1.25 mtr long ach duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations complete including removal of extg unserviceable one complete all as specified and directed. |
| 42 | M&L for battery teriminal brass clamps as per OEM specification including removal of extg unserviceable one compete all as specified and directed. |
| 43 | M&L for disconnecting all electrical connections from DG set charging alternator of any capacity from base plate by opening nuts & bolts keeping aside the alternator for inspection and taking out the to work shop for rewinding including testing & commissioning complete all as specified and directed. |
| 44 | Taking down turbo charger from engine of DG set of any capacity for servicing and replacement of turbo kit as per OEM specification complete all as specified and directed. |
| 45 | M&L for water temperature gauge including sensor and cable as per OEM specification complete as per sample including removal of extg unserviceable one complete all as specified and directed. |
| 46 | M&L for dismantaling the radiator taking to work shop for overhauling & cleaning, de-scaling with acid, removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads, drain out hoses pipe, clips, etc and refixing its original position for 15 KVA to 100 KVA capacities of DG set complete all as specified and directed. |
| 47 | All as per Srl item No. 46.00 above but 125 KVA DG set to 160 KVA DG set, complete all as specified and directed. |
| 48 | All as per Srl item No. 46.00 above but 180 KVA DG set to 250 KVA DG set, complete all as specified and directed. |
| 49 | M & L for repair and calibration of FIP and injectors from OEM for petty repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for 15 KVA to 100 KVA capacities of DG set complete all as specified and as directed. Note:- A certificate to the effect that the calibration and repairs has been carried out by the authorised dealer shall be submitted by the contractor. |
| 50 | All as per Srl item No. 49.00 above but 125 KVA DG set to 160 KVA DG set, complete all as specified and directed. |
| 51 | All as per Srl item No. 49.00 above but 180 KVA DG set to 250 KVA DG set, complete all as specified and directed. |
| 52 | M & L for Repair/ overhauling of self starting/ Exciter system as per OEM specification of DG set including replacement of carbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 24 volts with necessary connections incluing testing and commissioing complete all as specified and directed.. |
| 53 | M & L for Repair/ overhauling of self starting system of DG set including replacement of carbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 12 volts with necessary connections incluing testing and commissioing complete all as specified and as directed. |
| 54 | M & L for repairing of battery charging alternator engine as per OEM specification mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, carbon brushes of capacity 24 volts including testing and commissioing complete all as specified and directed. |
| 55 | M & L for repairing of battery charging alternator engine as per OEM specification mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, carbon brushes of capacity 12 volts including testing and commissioing complete all as specified and directed. |
| 56 | S & F in repair battery charging circuit suitable for 24 volts, DC in existing DG set panel board including addition/ alteration in wiring system complete with auto transformer, diodes, filter circiut, condensers, DC ammeter, DC volt meter with selector switches and indicating bulbs etc as per OEM specification complete all as specified and directed.. |
| 57 | S & F in repair battery charging circuit suitable for 12 volts, as per OEM specification DC in existing DG set panel board including addition/ alteration in wiring system complete with auto transformer, diodes, filter circiut, condensers, DC ammeter, DC volt meter with selector switches and indicating bulbs etc complete all as specified and directed.. |
| 58 | S&F in repair for AVR (automatic voltage regulator) control unit assembly as per OEM specification suitable for 15 KVA DG set to 160 KVA DG set including removal of extg unserviceable one compete all as specified and directed.. |
| 59 | S&F in repair for AVR (automatic voltage regulator) control unit assembly as per OEM specification suitable for 180 KVA DG set to 250 KVA DG set including removal of extg unserviceable one compete all as specified and directed. |
| 60 | M & L for fuel steel braided pipe with benjo bolts and washers as per OEM specification etc of length 30 cm long including removal of existing unserviceable one compete all as specified and directed. |
| 61 | M & L for fuel steel braided pipe with benjo bolts and washers as per OEM specification etc of length 45 cm long including removal of existing unserviceable one compete all as specified and directed. |
| 62 | M & L for fuel steel braided pipe with benjo bolts and washers as per OEM specification etc of length 60 cm long including removal of existing unserviceable one compete all as specified and directed. |
| 63 | M & L for canopy hinges for auqastic doors with suitable bolts and nuts of DG set including removal of extg unserviceable one compete all as specified and directed by Engr-in charge. |
| 64 | M & L for Anti vibration pads with suitable bolts and washers including removal of extg unserviceable one compete all as specified and directed.. |
| 65 | M & L for carrying our repairs to AMF panel/ Auto and Manual of up to 250 KVA DG set at various instllation inclduing study, tracing out circuit, testing, repalcing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioing complete all as specified and as directed. (Note:- Spares like Volt meter, CT, power contactor required for repair will be measured and paid under relevant items. complete all as specified and directed. |
| 66 | Supply only for digital type frequency meter 96 x 96mm flush/ square pattern as per OEM specification including removal of extg unserviceable complete all as specified and directed.. |
| 67 | Supply only for digital type Ammeter 0-400/ 5 Amps 96 x 96mm square flush pattern with selector switch as per OEM specification including removal of extg unserviceable one complete all as specified and directed. |
| 68 | Supply only for digital type Ammeter 0-200/ 5 Amps 96 x 96mm square flush pattern with selector switch as per OEM specification including removal of extg unserviceable one complete all as specified and directed. |
| 69 | Supply only for digital type Ammeter 0-100/ 5 Amps 96 x 96mm square flush pattern with selector switch as per OEM specification including removal of extg unserviceable one complete all as specified and directed.. |
| 70 | Supply only for digital type Voltmeter 0-500 Volts 96 x 96mm square flush pattern with selector switch as per OEM specification including removal of extg unserviceable one complete all as specified and directed. |
| 71 | Supply only for LED indicator lamps R, Y, B with holder 15mm screw type as per OEM specification including removal of extg unserviceable one complete all as specified and directed.. |
| 72 | Supply only for CT cast resin type of ratio 400/ 5 Amps of suitable VA burden as per OEM specification including removal of extg unserviceable one complete all as specified and directed.. |
| 73 | Supply only for CT cast resin type of ratio 200/ 5 Amps of suitable VA burden as per OEM specification including removal of extg unserviceable one complete all as specified and directed.. . |
| 74 | S & F for CT cast resin type of ratio 100/ 5 Amps of suitable VA burden as per OEM specification including removal of extg unserviceable one complete all as specified and directed.. |
| 75 | S&F in repair for Power Contactor as per OEM specification 415 Volt, 50 Hz AC suitable for DG set control panel/ AMF panel for 100 KVA to 160 KVA capacity of DG set complete all as specified and directed. |
| 76 | All as per Srl item No. 79.00 above but 180 KVA DG set to 250 KVA DG set complete all as specified and directed. |
| 77 | S & F for Time dealy relay as per OEM specification suitable for 15 KVA DG set to 100 KVA DG set including removal of extg unserviceable one complete all as specified and as directed. |
| 78 | S & F for Time dealy relay as per OEM specification suitable for 125 KVA DG set to 250 KVA DG set including removal of extg unserviceable one complete all as specified and as directed. |
| 79 | M & L for solinoid switch assembly 24 volts as per OEM specification suitable up to 250 KVA DG set including removal of extg unserviceable one complete all as specified and directed by Engr-in charge. |
| 80 | M & L for solinoid switch assembly 12 volts as per OEM specification suitable up to 250 KVA DG set including removal of extg unserviceable complete all as specified and directed. |
| 81 | M & L for self starter assembly 12 volts as per OEM specification complete suitable up to 250 KVA DG set including removal of extg unserviceable one complete all as specified and directed. |
| 82 | M & L for self starter assembly 24 volts complete suitable up to 250 KVA DG set including removal of extg unserviceable one complete all as specified and directed. |
| 83 | M & L for electronic speed control unit assembly 12 volts as per OEM specification suitable up to 250 KVA DG set including removal of extg unserviceable complete all as specified and directed. |
| 84 | M & L for electronic speed control unit assembly 24 volts as per OEM specification suitable up to 250 KVA DG set including removal of extg unserviceable complete all as specified and directed. |
| 85 | M & L for SMPS (system main power supply) type control unit assemblyas per OEM specification suitable for 12 volts battery charger for including removal of extg unserviceable complete all as specified and directed. |
| 86 | M & L for SMPS (system main power supply) type control unit assembly as per OEM specificationsuitable for 24 volts battery charger for including removal of extg unserviceable complete all as specified and directed. |
| 87 | S & F for single phase preventer as per OEM specification suitable for operation on 415 Volts 50 Hz AC supply including removal of extg unserviceable one complete all as specified and directed. |
| 88 | S & F in replacement for battery low maintenance lead acid of capacity 12 volts 180 AH with initial charging complete all as specified and directed. |
| 89 | S & F in replacement for battery low maintenance lead acid of capacity 12 volts 150 AH with initial charging complete all as specified and directed. |
| 90 | M & L for welding MS pipe heavy duty 100mm dia suitable for exhaust manifold of DG set with necessary scraping cutting to size as required and painting with two coats silver paint over a coat of redoxide primer including removal of extg unserviceable complete all as specified and directed. |
| 91 | M & L for Engine complete overhauling of DG set capacity UP TO 250 KVA of Kirloskar/ Crompton Greaves makes by opening the top cover complete including dismatlling the engine head, cylinder liner and piston assembly, crankshaft assembly, radiater fan belt and radiator fan, gear assembly complete removing of engine side for repair/ replacement of parts i.e gasket, washer, 'O' ring all types etc including grinding polishing of crank shaft, head repairing and overhauling valve seat cutting and replacing, valve tapping, head assemble and testing of DG set after necessary repair with and authorised dealer fix at site reassembling of DG set and testing on full load upto entire satisfaction of Engineer in Charge all as directed (Note:- Spare parts will be measured and paid seperately under relevent items) |
| 92 | (a) Supply only Piston assembly, complete all as specified and directed. |
| 93 | (b) Supply only Piston ring set, complete all as specified and directed. |
| 94 | (c) Supply only full engine gasket, complete all as specified and directed. |
| 95 | (d) Supply only Main bearing set, complete all as specified and directed. |
| 96 | (e) Supply only Main cylinder liner, complete all as specified and directed. |
| 97 | (f) Supply only Main cylinder head copper sleeves, complete all as specified and directed. |
| 98 | (g) Supply only Lock nut, compelte all as specified and directed. |
| 99 | (h) Supply only Big end bearing, complete all as specified and directed. |
| 100 | (i) Supply only Timing Belt, complete all as specified and directed. |
| 101 | (j) Supply only benjo bolt, complete all as specified and directed. |
| 102 | (k) Supply only Timing belt tension adjuster, complete all as specified and directed. |
| 103 | (l) Supply only inlet valve, complete all as specified and directed. |
| 104 | (m) Supply only Exhaust Valve, complete all as specified and directed. |
| 105 | (n) Supply only head gasket, complete all as specified and directed.. |
| 106 | (o) Supply only oil pump assembly, complete all as specified and directed. |
| 107 | (p) Supply only Thrust washer, complete all as specified and directed. |
| 108 | (q) Supply only Crank case gasket, complete all as specified and directed. |
| 109 | (r) Supply only Head nozzle plug set, complete all as specified and directed. |
| 110 | S & F for pressure gauge 0 to 7 Kg/ Sqcm as per OEM specificationalong with sensor and cables for DG set including removal of extg unserviceable one complete all as specified and directed. |
| 111 | S & F for microprocessor based multifunction controller as per OEM specification suitable for DG sets operation of any capacity and showing the various parameters such as volt, ampere, frequency, RPM etc complete as per site requirment including removal of extg old unserviceable one, complete all as specified and directed. |
| 112 | S&F in repair of connecting and testing MCCB in existing DG set Panel of 4 pole 200 Amps capacity with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu, suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON Position, connecting and testing complete including removal of exiting unsv complete all as specified and directed. |
| 113 | All as per Srl item No. 79.00 above but 4 pole 400 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu, complete all as specified and directed. |
| 114 | All as per Srl item No. 79.00 above but 4 pole 160 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu, complete all as specified and directed. |
| 115 | S&F connecting and testing open execution on load change over in existing DG set Panel of the following capacity, suitable for 415 volts, 50 Hz, 250 Amp, 4 pole with extended terminals type, interlocked to prevent opening when the Switch is in ON Position, connecting and testing complete including removal of exiting unsv change over complete all as specified and directed. |
| 116 | Supply and fill genuine coolant in 5 ltrs plastic sealed container for topping up in Radiator of DG set located at different locations as directed by Engr-in-Charge complete all as specified and directed. |
| 117 | M & L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strep 32 x 6mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40mm dia light grade GI pipe as shown in electrical plate no 3 of SSR Part-I of 2009 including necessary excavation and earth work GI pipe 20mm dia light grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 Type B1 (20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to panel board as indicated including testing including taking down old existing earthing complete all as specified and directed. |
| 118 | M & L for disconnecting all electrical connections from Coupling and flywheel DG set alternator of any capacity from base plate by opening nuts & bolts keeping aside the alternator for inspection and taking out the to work shop for rewinding including testing & commissioning complete all as specified and directed. |
| 119 | Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of size up to 250 KVA complete all as specified and directed. |
| 120 | S&F PVC insulated, Single core flexible cooper conductor cable, 1100 volt, Conf to IS 694, ISI Marked of size 70 Sqmm including fixing it by providing GI Strip clamp and also by using Heavy duty PVC tye on ground, and any other locations like on wall or laying on floor by providing saddles, including connecting terminals by providing copper lugs, brass nut and bolt with washer of suitable size as per site requirement to connect the cable including taking down old unserviceable cable complete all as specified and directed. Please Enable Macros to View BoQ information |