| 1 | Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and directed |
| 2 | Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in soft/loose of soil complete all as specified. |
| 3 | Removal of excavated soil to a distance n. exc 50 m above the starting point complete all as specified. |
| 4 | S&F in repair DWC pipe (6mtr length) of 63 mm of outer dia and 50 mm inner dia with connected sockets complete all as specified and as directed. |
| 5 | Taking out old serviceable/unserviceable LT UG cables of size 10 to 70 Sq mm 3.5/4 Core from trenches, poles/walls/ducts and floor including taking out old unserviceable/serviceable bricks covers/GI pipe of any size from trenches for removing or re-laying (after necessary repair/jointing) the cable complete all as specified and as directed. |
| 6 | Laying only and connection of serviceable XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of following sizes laid in trenches or fixed on walls/floor/pole complete all as specified and as directed. |
| 7 | (a) 10 sqmm to 70 Sqmm 3.5/4 core |
| 8 | Re-laying of old serviceable bricks as in cable protection cover, laid flat and dry in trenches over the cable length of brick laid prependicular to the direction of cable complete all as specified and as directed. Note:- Old serviceable bricks obtained from item here-in-before shall be used under this item. |
| 9 | M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as specified and as directed. |
| 10 | Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of the following sizes laid in trenches or fixed on wall/floor/poles complete all as specified and as directed :- |
| 11 | (a)10 Sq mm 4 core |
| 12 | (b)16 Sq mm 4 core |
| 13 | M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 50 mm bore below/ under existing road surfaces / floors at a level not less than 0.60 mtr etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed.Note : (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt. |
| 14 | S&F in repair LED street light 60 W intelligent dusk dawn sensor based automatic switch on and off based on ambient lux levels/day light levels including aluminium housing, clear toughened glass, silicon gasket, inbuilt 10KV SPD,>100 Lm/W, IP 66 and suitable for 50 mm dia bracket complete all as specified and directed. |
| 15 | S&F in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum housing , clear toughened glass and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with inbuilt 10KV SPD,>100 Lm/W, IP 66 and suitable for 50 mm dia bracket complete complete all as specified and directed. |
| 16 | S&F in repair LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing, clear toughened glass and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with inbuilt 10KV SPD,>100 Lm/W, IP 66 and suitable for 50 mm dia bracket complete complete all as specified and directed. |
| 17 | S&F in repair LED Solar street light fitting 40 Watt including galvanized steel pole(76 OD) height 6m , in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed. (Excavation & earth work shall be measured separately) |
| 18 | S&F LED flood light 250 watt 230 V AC outdoor type with thermal management inmultiple optics and equipped with IP66 protection, with impact and corrosion resistantcomplete with driver and lamp complete all as specified and directed.Note for Above item no. 11 to 15 - (i) The contractor shall be liable for at least 2 years warranty of LED lights. (ii) The security money shall be deposited by contractor against the warranty of LED lights as per policy. |
| 19 | S&F in replacement nature switch based timer 5KW single phase integrated model for LED Street lights control with voltage monitoring device,enclosed in SMC Enclosure conorming to IP 54 protection complete all as specified and directed. |
| 20 | Taking out lantern carriage of high mast light fitting with the help of integral power tools for repair and maintenance of unserviceable parts of any capacity including repair of winch power tool double drum and servicing and greasing of motor of highmast including replacement of minor defective parts with new parts (Major items shall be measured and paid seperately) and made the fittings serviceable complete all as specified and directed. |
| 21 | S&F in repair LED aviation obstruction light in red colour with 10 W capacity by lowering the lantern removing the old light and refixing the newly one and raising the lantern in same position with coonected accesssories complete all as specified and directed. |
| 22 | S&F copper conductor of size 5core, 2.5 Sqmm pvc sheathed flexible type for highmast trailing cable including removal of old cable and reconnecting with proper size of thimble and connected accessories complete all as specified and directed. |
| 23 | M&L for re-winding of existing highmast three phase motor of capacity upto 1.5 hp with reverse and forward moving ,6 pole single speed suitable for high mast including dismantling of motor and refixing after rewinding in same position with connected accessories complete all as specified and directed. |
| 24 | S&F in repair MCB FP 32 Amps, 230 volts, 10 KA with enclouser in existing highmast panel complete all as specified and directed. |
| 25 | S&F in repair MCB SP 6 to 32 Amps, 230 volts, 10 KA with enclouser in existing highmast panel complete all as specified and directed. |
| 26 | S&F in repair PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor flate/round 3 core, 2.5 Sqmm complete all as specified and directed. |
| 27 | Taking down carefully unserviceable LED street light, flood light fitting upto 250 watts of any type from pole/wall/High mast dismantling and checking out serviceability of parts/circuit such as drivers, etc repalcement of unserviceable parts with new parts including soldering with existing circuit board, reassembling and refixing in position including connecting, testing complete all as specified and directed. Note : New parts will be measured and paid separately under relevant items of BOQ as 'supply only'. |
| 28 | Supply only driver suitable for LED Security light 30/45 Watt complete all as specified and directed. |
| 29 | Supply only driver suitable for LED Security light 60/72 Watt complete all as specified and directed. |
| 30 | Supply only driver suitable for LED Flood light 90/110/120 Watt complete all as specified and directed. |
| 31 | Supply, erecting and fixing in repair true vertical position, steel tubular swaged pole (410 SP-31), 09 meter long, complete with cast iron base plate, pole cap/finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be painted with two coats of aluminium paint over a coat of red oxide primer including painting blue(sky blue) strips of 15 cm width in alternate layers up to 1.2 mtr above the ground level complete all as specified and directed.Note : Excavation, Earth work and PCC etc shall be measured and paid separately. |
| 32 | S&F in repair for pole factory made, dust proof, vermin proof , out door type Polycarbonate boxs not less in size 200x300x105 incl MCB SP 6 Amps,, 4 nos aluminium bus bar, insulator,GI nut, bolts and washers and aluminum lugs etc with and including FI clamp made out of 30 mmx 3 mm , nut and bolts complete all as specified and directed. |
| 33 | S&F in repair Street light bracket made out of 32 mm dia GI light grade pipe 1.2 mtr long bend to shape 120 degree and duly fixed alongwith existing pole/bldg with the help of 2 Nos of MS clamp of sizes 32x3 mm including suitable size of bolt ,nuts, and washers complete all as directed . |
| 34 | Demolition of PCC/Black bitumin road of any description and in any position not otherwise specially provided , etc complete all as specified and directed. |
| 35 | M&L for PCC (1:2:4) type B1 using 20 mm gradded stone aggregate for coping of poles, panel board etc complete all as specified and as directed. |
| 36 | M&L for cement concrete (1:3:6) type C2 using 40 mm gradded stone aggregate for Cement concrete in foundations , filling and mass concrete etc complete all as specified and as directed. |
| 37 | Surface dressing in soft/loose soil not exceeding 15 cm deep and removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr and spray of herbicide chemical to stop the growth of grass and bushings complete all as specified and directed.Note: The Security amount @2.5% or 2500.00 which ever is more shall be retained from FB/Submit FDR in favour of accepting officer against the guaranties for stop the growth of grass and bushing two years from actual date of completion of work. |
| 38 | M&L for trimming/cutting/chopping of tree branches all around LT/HT over conductor upto two meter and removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr complete all as specified and directed. Note-(i) The deemed rate shall includes all T & P required for tree branch cutting. |
| 39 | Releasing tension of existing OH line, of ACSR/copper conductor or GI earth wire of any size/type on existing OH line and restretching properly and fixing on existing insulators on OH cross arms of poles including disconnection service connection street light fitting etc and reconnecting the same after restretching complete all as specified and directed. (Note : Each conductor will be measured seperately). |
| 40 | M&L for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.00mm thick burried directly in ground vertically at a depth not less than 3.25 metre below normal ground level with top edge of earth plate at a depth not less than 2.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 32x6 mm as earthin lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforced with 8mm dia TMT bar at 75c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed. |
| 41 | Preparation of surface of LT steel poles 9 meter long, cross arms clamps etc for painting and M &L for painting with one coat of superior quality aluminum paint on exposed surface of poles and street light bracket mounted on the poles,junction box etc and making black strip upto1.5 Mtr height from ground level and writing pole Nos etc. written on it with black synthetic enamel paint compete all as specified and directed Please Enable Macros to View BoQ information |