| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sidesand ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing & reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately All works above plinth level upto floor V level |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 6 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :5 Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 7 | Extra for brick work with common burnt clay bricks/ cement concrete bricks in superstructure above plinth level upto floor five level |
| 8 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in Superstrcuture above plinth level upto floor V-level including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 9 | Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, pillars, piers, abutments, posts and struts. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platforms. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, buttresses, plinth andstring courses etc. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 16 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 17 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 18 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 19 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) excluding floating coat of neat cement 40mm thick with 20 mm nominal size stone aggregate. |
| 20 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 21 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 22 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) Sal wood |
| 23 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cementconcrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1stclass hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 25 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butthinges bright finished of required size with necessary screws Second class Kail wood |
| 26 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge Second class Kail wood |
| 27 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete 2 mm thick |
| 28 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 29 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 30 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work |
| 32 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 33 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 34 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete 250x16 mm |
| 35 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 150x10 mm |
| 36 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete 125 mm |
| 37 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete |
| 38 | Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete |
| 39 | Providing and fixing of C P fittings of approved brand as directed by EIC |
| 40 | C P Bib cock long nose |
| 41 | C P Bib cock short body |
| 42 | C P Angle valve |
| 43 | PVC Connection |
| 44 | C P Towel Rod |
| 45 | C P Towel Ring |
| 46 | Waste pipe with coupling |
| 47 | C P grating |
| 48 | Looking Mirror |
| 49 | Soap Dish |
| 50 | Steel Shelf |
| 51 | Shower |
| 52 | Ball valve 25mm CPVC |
| 53 | Ball valve 32mm CPVC |
| 54 | Tank nipple 25mm dia |
| 55 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. |
| 56 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 57 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid. |
| 58 | Providing and fixing of 01 HP motor for water storage tank of approved brand including all necessary fittings complete Job as directed by EIC. |
| 59 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 20mm nominal outer dia pipes. |
| 60 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 25mm nominal outer dia pipes. |
| 61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-char External work including trenching, refilling etc. 25mm nominal outer dia pipes. |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charExternal work including trenching, refilling etc. 32mm nominal outer dia pipes. |
| 63 | Providing and fixing of PVC Pipes and fittings of approved brand as directed by EIC |
| 64 | PVC Pipe 110mm dia |
| 65 | PVC Pipe 75mm dia |
| 66 | PVC floor trap 75mm |
| 67 | PVC P trap 100mm |
| 68 | PVC Door bend 110mm |
| 69 | PVC Plain bend 110mm |
| 70 | PVC Door bend 75mm |
| 71 | PVC Plain bend 75mm |
| 72 | Brick Manhole (1.5'x1.5') with cover |
| 73 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 74 | Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of:(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 75 | Providing and laying protective layer to water proofing with cement concrete 50mm thick in 1:2:4 (1 Cemant: 2 coarse sand : 4 graded stone aggregate) properly finished in proper Grade /Slope for proper drainage of rain water, including cost of waterproofing compound (Tapecrete or equivalent) mixed with concrete @ 50 ml per bag of cement with 10mm nominal size stone aggregate (Crushed) including all leads, lifts, costs and carraiges of all materials involved complete. |
| 76 | Disposal of surplus excavated earth from muncipal limits upto 10.0 km as directed by EIC at site. |
| 77 | Providing and fixing M.S. grills, Rialing, lockup doors of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer and paint all complete. |
| 78 | Providing and fixing of brick masonary manholes 300mmx300mm incluidng CI cover with frame, plaster and concrete base all complete. |
| 79 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 80 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite Work |
| 81 | Carraige of material from source to work site by M.T. |
| 82 | Sand Aveg. lead of 20 Km |
| 83 | Stone Agg. Below 40mm Aveg. lead of 20 Km |
| 84 | Bricks Aveg. lead of 125 Km Please Enable Macros to View BoQ information |