| 1 | Rewinding of stator winding of ceiling fan of 1200 mm / 1400 mm sweep with suitable size of super enameled copper wire including dismantling the old copper wire and vanishing greasing testing etc. as required (including less of scrap material, dismantle copper wire will not be taken back). |
| 2 | Replacement of fan condencer 2.5/3.15 MFD for above size of ceiling /exhaust fans as required (old condencer will not be retained by the contractor ). |
| 3 | Providing & fixing (Replacement) of suitable size of bearing 6201 / 6202 of make NBC / SKF for 1200 mm sweep ceiling fan including greasing including less the cost of old bearing etc. as required. |
| 4 | Providing & fixing of clip/clamp for capacitor including deduct of cost of old clip etc. as required. |
| 5 | Rewinding of stator winding of up to 450 mm sweep size exhaust fans with suitable size enameled copper wire (as per manufactaraur specification) including sleevingof stator suitable insulation materials ie \\"E\\" class varnish complete with dismentling and reassambling after repair i/c connection testing etc as required(Burnt copper wire will be retained by the contractor). |
| 6 | Lowering and Lifting of various sizes submersible motor pump set from/to the borewell including all accessories etc as required. |
| 7 | Providing & Fixing of Pump head cast Iron i/c rubber flage suitable for 0.5/1.0 HP monoblock pump etc as required. . |
| 8 | Rewinding of 1.0 HP Monoblock / Submersible motor with all necessary materials. The motor is to be wound taking the no. of coil turns and pitch etc as reqd as it was originally wound with reqd. size of super enamelled copper wire with \\"E\\" class insulating materials, varnishing,ball bearing,running capacitor, greasing & testing as required i/c transportation from site & back with a guarantee of 6 months. (Including less of cost of old Scap material) |
| 9 | Rewinding of 3.0 HP Submersible/ Monoblock/ Openwell motor with all necessary materials. The motor is to be wound taking the no. of coil turns and pitch etc as reqd as it was originally wound with reqd. size of super enamelled copper wire with \\"E\\" class insulating materials, Ball Bearing, varnishing, greasing & testing as required i/c transportation from site & back with a guarantee of 6 months.(Including less of cost of old Scap material) |
| 10 | Rewinding of 7.5 HP SuSubmersible/ Monoblock/ Openwell motor with all necessary materials. The motor is to be wound taking the no. of coil turns and pitch etc as reqd as it was originally wound with reqd. size of super enamelled copper wire with \\"E\\" class insulating materials, varnishing,Bearing, greasing & testing as required i/c transportation from site & back with a guarantee of 6 months. (Including less of cost of old Scap material) |
| 11 | Rewinding of 10.0 HP Submersible/ Monoblock/ Openwell motor with all necessary materials. The motor is to be wound taking the no. of coil turns and pitch etc as reqd as it was originally wound with reqd. size of super enamelled copper wire with \\"E\\" class insulating materials, varnishing,Bearing, greasing & testing as required i/c transportation from site & back with a guarantee of 6 months. (Including less of cost of old Scap material) |
| 12 | Rewinding of 15.0 HP Submersible/ Monoblock/ Openwell motor with all necessary materials. The motor is to be wound taking the no. of coil turns and pitch etc as reqd as it was originally wound with reqd. size of super enamelled copper wire with \\"E\\" class insulating materials, varnishing,Bearing, greasing & testing as required i/c transportation from site & back with a guarantee of 6 months. (Including less of cost of old Scap material) |
| 13 | Servicing of Split & Window type of 1.5/2.0 Ton Air conditioner i/c Cleaning/washing of filters, checking of gas pipings/leakages, insulation, compressor and all electric connections etc as required. |
| 14 | Servicing of 1.5/2.0 Ton split type AC using chemicals wash the copper coil of outdoor unit to remove dirt and solid particles for cooling as required. |
| 15 | Supplying and replacement of rotary compressor suitable for 1.5 ton Split/window AC i/c refilling the required qty of requisite oil and gas including one years warrenty i/c installation testing and commissioning etc as required. (Carrier/Volats /Llyod//LG) |
| 16 | Providing and refilling of Gas (Charging of Refrigent R-22/ 410/314 A) suitable for 1.5 / 2.0 Ton Split & window type Air conditioner of and making functional etc as required. |
| 17 | Providing and fixing of starting / Running Capacitor suitable for 1.5/2.0 ton air conditioner i/c connection and testing etc as required. |
| 18 | Providing and fixing of fan 3.15 mfd capicator for for 1.5/2.0 ton air conditioner i/c connection and testing etc as required. |
| 19 | Providing and fixing of Swing motor new suitable for 1.5/2.0 ton air conditioner i/c connection and testing etc as required. |
| 20 | Providing and fixing of PCB plate suitable for 1.5/2.0 Ton split type air conditioner i/c installation testing and commissioning etc as required. |
| 21 | Providing and fixing of blower motor of 1.5 Ton split type air conditioner i/c connection and testing etc as required. |
| 22 | Repairing of 5/4 KVA voltage stabiliser changing of relay, PCB , Volt meter,transformer & connection testing etc all electric connections etc as required. |
| 23 | Providing and Fixing of remote with stand suitable for 1.5/2.0 Ton split type AC including deduct of cost of old Remote as required. |
| 24 | Providing and replacement of Heating Element of 2 kW suitable for 15/25/35/50 Ltr Geyser connection testing etc as required. |
| 25 | Providing and replacement of Thermostate suitable for 15/25/35/50 Ltr Geyser connection testing etc as required. |
| 26 | Cleaning of Geyser tank (15/25/35/50 Ltr) and pipe line with required material and mechanic, connection testing etc as required . |
| 27 | Providing and replacement of Geyser indicators Lamp (Red & Green) 300-500V suitable for 15/25/35 Ltr Geyser connection testing etc as required. Please Enable Macros to View BoQ information |