| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 2 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings. |
| 3 | Dismantling wrought iron or mild steel work of any description |
| 4 | Dismantling timber scantlings 40 sq. cm and over in section unframed work in any position |
| 5 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 6 | M & L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in Cement mortar 1:4. |
| 7 | Taking down Chowkhats or frames exc. 1.5 sq. m but n.exc. 4 sq.m each with shutters (without taking off shutters from the frames) and removing to CW store as directed |
| 8 | Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 9 | Demolition of reinforced cement concrete in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work |
| 10 | Laying of Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface (Except material) as directed. |
| 11 | M&L for providing cement concrete type B-1, 1:2:4 (20mm graded aggregate), 100mm thickness as directed. |
| 12 | S&F Steel work in tubular trusses and purlins etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 |
| 13 | S&F of rolled mild steel in plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections Fe-290 (Gde E 165) |
| 14 | S&F of Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 as directed. |
| 15 | M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width, Type C1, 1:3:6 (20mm graded aggregate) set in CM 1:4, complete as directed. |
| 16 | S&F of Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified |
| 17 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with coach screws. |
| 18 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil as directed. |
| 19 | M&L for cement concrete for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete Type-B1, 1:2:4, 20 mm graded aggregate. |
| 20 | M&L for Cement concrete in surface channels and drains Type-D2, 1:4:8 (40mm graded aggregate) |
| 21 | M&L for Reinforced concrete pipes bore 300 mm, class NP2, laid and jointed complete with collars |
| 22 | Providing precast cement concrete, type-B1,1:2:4 mix ratio using 20mm graded aggregate in landings, cover slabs (for man holes / Drainage etc.), shelves and similar articles with plain faces including formwork and finishing set in Cement mortar 1:4 as directed. |
| 23 | Welded steel wire fabric supplied and fixed complete to wood or steel members Weight per square metre N exc 4 kg |
| 24 | M&L for cement concrete Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like Type, B1 1:2:4 (20mm graded aggregate) |
| 25 | Formwork to soffits of suspended slabs rough finished flat surface of concrete such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 26 | Formwork to sides rough finished flat surface of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 27 | M&L for TMT bars , 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as directed. |
| 28 | M&L for Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite including M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes |
| 29 | Providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete. |
| 30 | M&L for Rendering 12 mm thick on fair faces of brick work or concrete surfaces in cement plaster 1:4 |
| 31 | M&L for Rendering 12 mm thick on fair faces of brick work or concrete surfaces in cement plaster 1:4 provided as floating /setting coat |
| 32 | S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm |
| 33 | S & F 25 mm Bore dia. Tubes, 'Medium Grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors. |
| 34 | S & F 15mm Bore dia. Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule as directed |
| 35 | M & L for Distempering walls with white or tinted distemper oil emulsion 02 coats , 01 coat with alkali resistant priming paint including preparatory works on new surfaces as directed. (Make: Asian/ Dulux/ Nerolac as approved by the EIC to be used). |
| 36 | M & L for Painting on new steel surfaces of any description, over 10cm width or girth, using synthetic enamel paint two coat including one coat zinc chrome primer and preparatory works as directed. (Make: Asian/ Dulux/ Nerolac as approved by the EIC to be used). |
| 37 | Removing excavated material /soils exc. 1km but n exc. 5km and depositing where directed |
| 38 | Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of exc. 100m and n.exc. 1000m, including loading, unloading and stacking at the destination. Please Enable Macros to View BoQ information |