|
| 1 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 2 | Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately) complete all as specified and as directed. |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 4 | Dismantling pre-cast RCC fencing posts or struts (wood, steel or RCC) any section including taking out embedded portion in concrete complete all as specified and as directed. |
| 5 | Excavation in post hole (or similar holes) each n.exc 0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil to a distance n.exc 50 m and making good in hard/dense soil.complete all as specified and as directed. |
| 6 | M & L for PCC (1:3:6) type D-2 (using 40 mm graded stone aggregate ) as in foundation filling or mass concrete, complete all as specified and as directed. |
| 7 | S & F mild steel work conforming to Fe 290.Gde-E-165 in posts & struts in swan neck angle including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and as directed. |
| 8 | S & F steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161 1979 grade St 240 complete all as specified and as directed. |
| 9 | M&L for mild steel round bars 10mm dia and over cut to length bent to shape required and fixing as required in fencing of Fe-410 W(gde-E-250) quality A or Fe 290 (gde-E-165). complete all as specified and as directed. |
| 10 | Supply only chain link MS galavanised fencing complete all as specified and as directed. |
| 11 | Fixing only chain link fencing including line wires, and mesh size type of stadrads, rail straining bols etc size of mess (100mm x 100 mm x 4 mm) dia wire complete all as specified and as directed. |
| 12 | S&F in repairs for galvanised 2 str and steel barbed wire 2.24 mm dia barbed with 2mm dia bars and 75mm spacing and straining and fixing to any type of standard rails straining bold, inc securing or typing at crossing with galvanised mild steel wire staples or steel pins (each line wire to be measured ) complete all as specified and as directed. |
| 13 | S&F MS bolts machine made with hexagonal or square head one end and screwed the other or screwed both end n.ext 5 cm long, 12 mm dia. complete all as specified and as directed. |
| 14 | Dismanteling to plain or corrugated MS sheet any gauge, thickness including nainital or similar pattern as in roof covering complete all as specified and as directed. |
| 15 | S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof / wall covering, fixed with self tapping screws etc complete all as specified and as directed. (Note:- Item rate shall be include any height of Bldgs / Hangars for scaffolding as all arrangement.) |
| 16 | M&L for two coat of synthetic enamel paint to new steel surface over a coat of red oxide primer n exc 10 cm width or girth incl preparation of new surfaces complete all as specified and as directed. |
| 17 | M&L for two coat of synthetic enamel paint to new steel surface over a coat of red oxide primer exc 10 cm width or girth incl preparation of new surfaces complete all as specified and as directed. |
| 18 | M&L for preparing surfaces of new steel and iron work of any description and girth at treated area n.exc 0 .5 sq each and treated with Tar/ Coal tar black paint complete all as specified and as directed. |
| 19 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) complete all as specified and as directed.. |
| 20 | M&L for 100 mm thk PCC (1:4:8) type D-2 as in subbase to flooring complete all as specified and as diretcted. |
| 21 | M&L 40 mm thick PCC (1:2:4) ,type B-1(20 mm graded aggregate) in flooring with finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 22 | M&LGlass dividing strips, 3 mm thick 38mm wide inserted in position complete all as specified and as directed. |
| 23 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.. complete all as specified and as directed. |
| 24 | M&L for chequered cement concrete tile (30 cm x 30 cm x 20 to 25 mm) thick set jointed and pointed in neat cement siurry in floor with grey cement and pig ments over 20 mm thick screed bed or bedding layer of CM (1:6) complete all as specified and as directed. |
| 25 | M&L for 50mm avg thickness sand filling / cushioning bed with necessary consolidation for bedding layer of tiles etc complete all as specified and as directed.. |
| 26 | M&L for Machine pressed precast concrete interlocking paver block any shape and size conferming to IS 15658-2006 of 80 mm thick M-40 Grade with gray cement and pigment ccomplete all as specified and as directed. |
| 27 | M&L for Machine pressed precast concrete interlocking paver block any shape and size conferming to IS 15658-2006 of 60 mm thick M-35 Grade with gray cement and pigment complete all as specified and as directed. |
| 28 | M&L for cement concrete Type B-0 using 12.5 mm graded stone aggregate (Nominal mix in 1:2:4) in copings, benching and the like including weathering slightly rounded or chamfered angles as directed including necessary form work and finishig all exposed surfaces complete all as shown on drgs complete all as specified and as directed. |
| 29 | Demolition of reinforced cement concrete (Reinforcement cut as required to facilitate deomolitions) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 30 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed. |
| 31 | M&L for Reinforced cement concrete type B1, (1:2:4) using 20 mm graded aggregate as in foundation, including rafts, footings,foundation beams, base for columns etc, basement slabs, under-reamed piles and mass concrete complete, all as specified and as directed. |
| 32 | M&L for Reinforced cement concrete type B1, (1:2:4) using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete, all as specified and as directed. |
| 33 | M&L for RCC (1:2:4) type B-1 (20 mm graded aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 34 | M&L Pre-cast cement concrete cover slab for manhole and drain in plain cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) set in cement mortar (1:4) with plain faces complete all as specified and as directed. (Note:- Reinforcement shall be measured and paid seperately) |
| 35 | Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits(if any) in foundation, plinth beams and similar work vertical or to batter complete all as specified to give rough finished surfaces on flat surfaces of concrete. complete all as specified and as directed. |
| 36 | M&L Form work to sides of square or rectangular columns, pillars, posts and struts for rough finished surfaces of concrete complete all as specified and as directed. |
| 37 | M&L for form work to sides and soffits of beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves etc in fair finished surface complete all as specified and as directed. |
| 38 | M & L for Mild steel TMT steel bar 10 mm dia & over cut to length bent to shape required and binding wire with and including MS wire annealed not less than 0.9 mm dia as in reinforcement complete all as directed and as specified. |
| 39 | M&L for MS TMT bars 05 mm and over, upto and including 10 mm dia in stirrups, spaces and binders complete all as specified and as directed. |
| 40 | S&F mild steel framed work such as grills, gratings as for ornamental and intricate design gates side hung including pintle hinges, stops, hand made sliding bolts, etc confirming to Fe-290, Gde-E-165 complete all as specified and as directed. |
| 41 | Demolition of brick/precast concrete block walling built in cement mortar complete all as specified and as directed.. |
| 42 | M&L for Pre-cast cement concrete (1:2:4) type B1 (20 mm graded aggregate) block masonry with solid blocks,set in 1:6 cm, exc. 10 cm in width and setting in mortar, complete all as specified and as directed. |
| 43 | Taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 44 | Rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished fair and even to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed. |
| 45 | Rendering 20 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished fair and even (without using extra lime or cement) complete all as specified and as directed. |
| 46 | M&L for Preparation of new plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistance primer complete all as specified and as directed. |
| 47 | M&L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs pillars, window cills ,cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade or granite over including rendering 10mm thick in CM (1:4) etc complete all as specified and as directed. |
| 48 | M&L PCC (1:3:6) type C-1 (using 20 mm graded aggr) as in surface channels & drains,benching of manholes complete all as specified and as directed.. |
| 49 | Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc. complete all as specified and as directed. |
| 50 | M&L cutting into existing manholes (150 mm dia pipe) for connecting new drains,making good to pipe and rendering,cutting out existing benching for and forming branch cahnnel(1/2 round or 3/4 section) incement concrete (1:2:4) type B-1 smooth finished and reforming benching as required complete all as specified and as directed. |
| 51 | Demolition and breaking up drain pipes (Salt glazed ware, PVC/AC or Reinforced concrete) set in cement mortar,and taking out of trenches, if required, Internal dia of pipe in 75MM/100mm complete all as specified and as directed. |
| 52 | Supplied and fixed PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed. |
| 53 | Supplied and fixed PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floorscomplete all as specified and as directed. |
| 54 | Taking down eaves gutters and rainwater pipes (any size or pattern) , including all fitting ,head, shoes ,bend, swan-nacks etc., including cleaning or refixing or removal to store. complete all as specified and as directed. |
| 55 | Supplied and fixed PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed..(ISI MARKED) |
| 56 | Supplied and fixed PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 57 | Supplied and fixed PVC (SWR) bends any radius 110 mm dia complete all as specified and as directed..(ISI MARKED) |
| 58 | Supplied and fixed PVC (SWR) bends any radius 75mm dia complete all as specified and as directed.(ISI MARKED) |
| 59 | Supplied and fixed PVC (SWR) Single 'T ' any radius 110 mm dia complete all as specified and as directed. (ISI MARKED) |
| 60 | Supplied and fixed PVC (SWR) Single 'T' radius 75 mm dia complete all as specified and as directed. (ISI MARKED) |
| 61 | Supplied and fixed PVC (SWR) double 'Y ' any radius 110mm dia complete all as specified and as directed. (ISI MARKED) |
| 62 | Supplied and fixed PVC (SWR) double 'Y '' any radius 75 mm dia complete all as specified and as directed. (ISI MARKED) Please Enable Macros to View BoQ information |