| 1 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil |
| 3 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. In soil. |
| 5 | M&L for Cement concrete in foundations, 1:3:6 type C2 using 40mm graded aggregate filling and mass concrete complete all as specified and directed |
| 6 | M&L for Brick work with sub class 'B' brick straight or curved on plan exc 6 m mean radius built in CM 1:6 |
| 7 | M&L for mild steel angle/flat iron securing bolt posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh/chain link fencing etc.) including all necessary drilling, bolting or riveting, and similar work complete all as specified and directed |
| 8 | M&L Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia/fixed with welding work supplied and fixed in position weight not exceeding 4.00 Kg/Sqm |
| 9 | M&L for preparing new steel surface of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint overa coat of red oxide primer complete all as specified and directed |
| 10 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 smooth and finished complete all as specified and directed |
| 11 | M&L for preparation of new concrete surface and applying two coats of cement base paint complete all as specified and directed |
| 12 | M&L for Cutting holes into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required exc 150 Sqcm but n. exc 400 Sqcm upto depth of 150mm complete all as specified and directged. |
| 13 | M&L for Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed of 300 mm long and fixed in position |
| 14 | M&L for mild steel but hinges 100mm long meduim weight and fixed in position complete. |
| 15 | M&L for Collapsible/Channel steel gates, made by MSFlat iron of size as directed by Engr-In-Charge top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete |
| 16 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth arround, in layers not exceeding 25 cm, in any type of soil complete |
| 17 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete |
| 18 | M&L for PCC 1:3:6 type C2 using 20mm graded aggregate as in filling mass concrete complete |
| 19 | M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 |
| 20 | M&L for precast cement concrete louveres and jallies 1:2:4 type B-0 using 12.5mm graded aggregate 25mm thick ( Measured solid) and fixed in position complete |
| 21 | M&L for re-inforcemment cement concrete1:2:4 type B-1 using 20mm graded aggregate as in lintel Beamsetc complete |
| 22 | M&L for TMT bars 10mm dia over cut to length bent to shape reqd, incl cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, quality confirming to Fe 410-S or Fe 410-0. |
| 23 | M&L for TMT Bar 5mm dia and over upto and including 10mm dia cut to length bent to shape reqd, incl cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers and binders complete |
| 24 | M&L for Formwork to sides and soffits of floor or roof beams, lintel beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. flat and rough finished complete |
| 25 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 |
| 26 | M&L preparation of new steel surfaces of any description over 10cm width or girth, not other wise described and applying two coat of synthetic enamel paint over a coat of primer. |
| 27 | M&L for 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 28 | M&L 15 mm thick plaster in CM (1:4) finished fair and even on brick/concrete surfaces on ext external surface of wall. |
| 29 | M&L concrete bed to drain pipes in cement concrete 1:3:6 type C2, 200 mm bore incl packing under and hunching against the sides of pipe after they are laid and teste complete all as specified and directed |
| 30 | M&L for re-inforced cencrete pipe, class NP-2 with one collar per length of 200 mm dia and fixed in position complette all as specified and directed. |
| 31 | M&L for Hardcore of broken stone or boulder of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 32 | M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed |
| 33 | M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 |
| 34 | M&L for Chequered cement concrete tilesof any size as directed by Engr-In-Charge and 25mm thick, set, jointed and pointed in neat cement slurry in floors |
| 35 | M&L for preparing new plastered surface of wall and aplying two coats of cement base paint over a coat of primer complete all as specified and direced. |
| 36 | Returning , filling , including spreading , levelling, watering and well ramming in layers not exc 25cm all as specified and directed |
| 37 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point as directed by Engr-in-Charge |
| 38 | M&L for Anodised aluminium frame powder coated for doors,partion wall including aluminium clip for glazing glass and pre laminated decorated ply etc complete all as specified and direced. |
| 39 | M&L for sheet glass oridinary quality 4.80mm thick and fixed in partion wall complete all as specsified and direcged. |
| 40 | M&L for Sun Glass film and fixed over glass complete all as directed by Engr-In-Charge. |
| 41 | M&L for Anodised aluminium door shutters,powder coated aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. |
| 42 | M&L for Aluminium alloy, anodised, sliding door bolt with hasp,300 mm long clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed and fixed in position complete |
| 43 | M&L for Mild steel Mortice lock, 4 lever vertical stype size 100 and fixed in door complete |
| 44 | M&L for Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in door/floor of 150mm long |
| 45 | M&L for Door closer hydraulically regulated, designation No-3 universal type suitable for door shutters of 851 to 1000 mm in width and of weight od door shutter between 61 to 80 kg and fixed in position complete |
| 46 | M&L for Wire netting of stainless steel wire 1.4mm dia and 12mm mesh fixed with tinned tacks of stainless steel wire staples and fixed in position complete |
| 47 | M&L for Cutting openings, through brick walls for door, window built in Cement mortar and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus matrl to out side of MD land complete all as specified and directed. |
| 48 | M&L for pre laminated Plain coloured PVC sheet 1.50 mm thick fixed or laid on to flush doors by using rubber based adhesive, supplying & fixing at site as per specification Please Enable Macros to View BoQ information |