| 1 | Labour charges for annual maintenance and repairing of electrical wiring & electrical installation of all offices and all pump houses panel including replacing of damaged electrical materials (Supply separately) including operation of pumps for all pump houses and operation of valve for office buildings incl. submersible pumps to maintain the water supply throughout the daily by filling O.H resorvoir atleast 3 times a day & engagement of 02(two) nos. lift operator having requisite permit for operation of one no VIP/general lift incl. cleaning and sweeping of the lift car, machine room and checking of lift light, machine room electrical wiring, petty repairing such as replacement of fuse, light mat etc. as per direction of EIC. Electrician & helper also maintaining staircase light, campus light, minor maintenance of 11KV substation, maintenance of sinage, cleaning of fan of above buildings by engaging 01(one) no. electrician, 01(one) no. helper during that period. The work should be executed by maintaining job resister with attendance register as per direction of EIC. |
| 2 | Electrician-1 no. @Rs.17372.00 per month per head |
| 3 | Semi skilled Helper-1 nos. @Rs.15843.00 per month per head |
| 4 | Lift operator - 02 nos. @15843.00 per month per head |
| 5 | Overtime over normal working hours. (If required) |
| 6 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 6-32A (Make: Havells or equivalent). |
| 7 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 40A DP (Seimens or equv.) |
| 8 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 63A FP (Seimens or equv.) |
| 9 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 100A FP (Seimens or equv.) |
| 10 | Supplying of approved make high speed ceiling fan (ISI make0 of following size having double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250V. 900mm/1050mm/1200mm |
| 11 | Supplying of approved make wall fan oscillating type with base, blades, guard,speed ragulator etc. AC 230-250V. 400mm Sweep |
| 12 | Supplying of approved make Pedestal fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts. 500mm sweep. |
| 13 | Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250. 225mm sweep RPM 900 / 1400 (9\\") |
| 14 | Supplying of approved make plastic ventilating exhaust fan AC 230-250. Ventilus 8\\" 200 Ivory, White, make : crompton |
| 15 | Opening the Ceiling fan testing, checking and Re-winding by supplying super enamelled copper wire of appropriate gauge, minilex paper, mica sheet, changing the loops, overhauling, backing, varnishing, re-fitting and using and measuring r.p.m. for ceiling fan above 36\\" sweep up to 60\\" sweep. |
| 16 | Supplying following sizes Capacitor of 250V rating: |
| 17 | 2.5 MFD Capacitor (Universal Make or equivalent) |
| 18 | 4 MFD Capacitor (Universal Make or equivalent) |
| 19 | Supply and fixing of philips Soft Glow Office compliant fully diffused recessed mounted 2'X2' false ceiling based LED light including connection by 1.5 sq mm cu wire. Make : Philips 36 Watt. |
| 20 | Supply and fixing of GreenLED Ultima Square (6\\" x 6\\") , incl cutting the false ceiling in reqd dimensions also the wiring and connection of the light by 1.5 sq mm cu wire complete. Make : Havells, 18 watt square/ round. |
| 21 | Supply and fixing of Havells Post top Luminaries model no : CORALPT35WLED (35Watt) over the preinstalled GI Pipe over the gatestructure or similar structure incl. connection by 1.5 sq mm cu wire from loop box to the light. |
| 22 | Supply and fixing of philips Smartbrite Xtra 4ft run length LED Batten Tube light, incl Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. Philips make, 40 Watt. |
| 23 | TMC501 Conventional industrial batten Philips LEDtube, model.no : TMC 501 P 1xT-LED 22 W P3241 |
| 24 | Supplying of different types of LED lamps. Make : Philips, 9.0 Watt, Base B22/ E27, 825 Lm |
| 25 | Supplying of different types of LED lamps. Make : Philips, 12.0 Watt, Base B22/ E27, 1200 Lm |
| 26 | Supplying and delivery including carriage, handling, fixing of the following materials at site for electrical repairing work. |
| 27 | 1.5 sq.mm 'FR' stranded Copper Wire |
| 28 | 2.5 sqmm'FR' stranded Copper Wire |
| 29 | 4.0 sqmm 'FR' stranded Copper wire |
| 30 | 6.0 sqmm 'FR' stranded Copper wire |
| 31 | 1 module GI/PVC box |
| 32 | 2 module GI/PVC box |
| 33 | 4 module GI/PVC box |
| 34 | 6 module GI/PVC box |
| 35 | 2 row 12 module GI/PVC box |
| 36 | 2 row 18 module GI/PVC box |
| 37 | 2 module Cover plate |
| 38 | 3 module Cover plate |
| 39 | 4 module Cover plate |
| 40 | 6 module Cover plate |
| 41 | 2 row 12 module Cover plate |
| 42 | 2 row 18 module Cover plate |
| 43 | One way Circular Box & cover |
| 44 | Two way Circular Box & cover |
| 45 | PVC inspection box of 175x100x65mm |
| 46 | 3 way Ceiling Rose/Batten Holder |
| 47 | Ding Dong Call Bell (Anchor) |
| 48 | Bulk head light fitting (Havells Make) |
| 49 | 20 mm dia PVC Conduit |
| 50 | 25 mm dia PVC Conduit. |
| 51 | PVC casing-capping of size 25x12mm |
| 52 | 13mm heavy gauge Polythene Pipe |
| 53 | 6A Modular type Switch |
| 54 | 15A flushed type 3 pin Plug Socket |
| 55 | Step Type Electronics Fan regulator |
| 56 | 16A Modular type Switch |
| 57 | 6A Modular type 5 pin Plug Socket |
| 58 | 16A Modular type 6 pin Plug Socket |
| 59 | 20/25A socket |
| 60 | 20/25A starter |
| 61 | 20/25A plug top |
| 62 | GST@18% on total amount |
| 63 | CESS@1% on total amount Please Enable Macros to View BoQ information |