| Sl. No. | Item Description |
| 1 | PART-A (CIVIL WORK) |
| 2 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. ( CSR Item No.6.6 ) |
| 3 | Cement Concrete 1:6:12 (b) with stone aggregate 40mm gauge stone aggregate (ii) using mixing by mechanical means using concrete mixer volumetric type. ( CSR Item No. 10.8 b (ii)) |
| 4 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth. ( CSR Item No. 11.3 (i)) |
| 5 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded. ( CSR Item No. 10.26) |
| 6 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. ( CSR Item No. 11.4 (i)) |
| 7 | 115 mm thich brick wall in cement sand mortar 1:4 without reinforcement superstructure. ( CSR Item No. 11.36) |
| 8 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. ( CSR Item No.9.6 ) |
| 9 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. ( CSR Item No.9.8 ) |
| 10 | RCC M-20 mechanically batch mixed using batch type concrete mixer as per IS: 1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. ( CSR Item No. 10.2) |
| 11 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete. ( CSR Item No. 18.19) |
| 12 | Dismantling of walls tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. ( CSR Item No.30.94 ) |
| 13 | Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. ( CSR Item No. 30.95) |
| 14 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. ( CSR Item No. 14.72) |
| 15 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Glossfinish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. ( CSR Item No.14.127 ) |
| 16 | Dismantling of flexible pavement (by mechanical means ) (a) Dismantling of flexible pavements thickness above 50mm by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT&H specifications. ( CSR Item No.24.3 (a)). |
| 17 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.(a) Door of area 3 sqm. and below. ( CSR Item No. 8.26 (a)) |
| 18 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge. ( CSR Item No. 8.44) |
| 19 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded). ( CSR Item No.31.11) |
| 20 | 20mm thick cement plaster 1:6 in two coats work.( CSR Item No. 15.28) |
| 21 | 12.5 mm thick cement plaster 1:5. ( CSR Item No.15.1 ) |
| 22 | Cement rendering on plaster 1mm thick . ( CSR Item No. 15.48) |
| 23 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing. ( CSR Item No.13.13( i)) |
| 24 | Cement concrete 1:2:4 gola 10cmx10cm concave quadrant along junction of roofs with parapet wall finished smooth where specifically specified. ( CSR Item No. 13.55) |
| 25 | Khurra on roof as per item No. 13.43 with C.I. Spouts 100 mm dia fixed in position. ( CSR Item No.13.46 ) |
| 26 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes single socketed (working pressure 4 kgf/cm2) confirming to IS: 4985, including fixing with MS clamps (i) U-PVC pipes (working pressure 4 kgf/sqm) pipe 110 mm dia. ( CSR Item No. 13.74 A (a) i)) |
| 27 | Providing and fixing 110 mm dia. U.P.V.C coupling/socket bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. (a) UPVC 110 mm bend. ( CSR Item No.13.76 (a )) |
| 28 | Providing and laying LDPE (Low Density Polythylene sheets ) over roofing before laying of roof tiles, having thickness of 200 micron including cutting, jointing (heat seal jointing with hot iron ) and overlapping of minimum 150mm and CC gola 75mm wide, complete in all respect to the satisfaction/approvl of engineer-in-charge. ( AOR ) |
| 29 | Scraping white wash and color wash ( CSR Item No. 8.31 (a)) |
| 30 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish. ( CSR Item No.16.65 ) |
| 31 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade. ( CSR Item No. 16.1) |
| 32 | Carriage of material (Earth, Surkhi. Sand, Earth, Fly Ash. Bajri. Ballast. Stone Boulders. Kankar and Building Rubbish, Earth)including loading and unloading (metaled roads)With lead up to 1.00 km. ( CSR Item No. 5.2 (i) & 4.1 (B)) |
| 33 | Providing and fixing tiled false ceiling at hight upto 4 mtr. of specified materials of size 595x595mm (GI Metal Ceiling Lay in perforated Tangular edge global white color tiles of size 595x595 mm and 0.5mm thick with 8mm drop ;made of GI sheet having galvanizing of 100gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes and having NRC (NoiseReduction Coefficient )of 0.5,electro statically polyester powder coated of thickness 60microns (minimum), including factory painted after bending and perforation,and backed with a black Glass fiber acoustical fleece..) inter horizontal level,suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120grams/sqm, both side inclusive)consisting of main \\"T\\" runner with suitably spaced joints together required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, space data 1200mm center to center and cross \\"T\\" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main \\"T\\" at 600mm center to center to form a grid of 1200x600mm and secondary cross \\"T\\" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be inter locked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size24x24x0.3mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with12.5mm dia and 50mm longdash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8mm spaced at 1200mm center to center along main T,bottom exposed width of 24mm of all T sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawing sand as directed by Engineer-in-charge. ( CSR Item No. 13.81) |
| 34 | WATER PROOFING WORK AT TERRACE AREA: Supplying and applying SmartCare Damp Proof Ultra, fiber reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflectivity Index (SRI) of 105 on top of roof in three coats @ 1.2 litre/sqmt to be reinforced, having minimum elongation of 350%, tensile strength 2.9Mpa and shall have crack bridging ability of up to 2.5mm and shall resist 10bars of hydrostatic pressure, reduces surfaces temperature up to 10 degree Celsius also IGBC certified (Indian Green Building Council) Certificate will be provided by company. The system consists of self priming with 33% water dilution followed by two undiluted coats of Damp Proof ultra , the fibre mesh of 40 to 50 GSM must be sandwich between 1st and 2nd coat of Damp Proof Ultra. (dry film thickness of complete application/system not less than 500 microns) and Ponding test to be done after application of material.( NS ) |
| 35 | Apply a coat of uv based Waterproofing (diluted with water in the ratio 2:1) self-priming coat in the SSD condition. Apply 1st coat of uv based Uv based chemical at the rate of of 0.45 – 0.5 / litre / Sq.mt / Coat. Laying a 45 Gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwiched between the first and second coat. While the 1st coat is still wet. Allow the first coat to dry for 4-6 hours. Apply second coat of uv based chemical with the same application coverage. Application direction of second coat should be perpendicular to that of the first coat. Allow second coat to dry for 4-6 hours. Apply third coat of uv based chemical at an application direction that is perpendicular to that of the second coat. Allow the system to air cure for 7 days minimum. The material having following technical properties: Attains a Tensile Strength with Fiber N/mm 2 ≥6-8 as per ASTM D 2370; Elongation at break ≥ 200% as per ASTM D 2370, Crack bridging ability up to 2 mm, Shore-A Hardness 80 as per ASTM D2240-2015, Tear Resistance with Fiber N/mm 34 as per ASTM D 624. ( ( NS ) . |
| 36 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.( CSR Item No.33.19 ) |
| 37 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge.(ii) 4 mm thick ACP sheet. ( CSR Item No.17.97 (ii) ) |
| 38 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material. ( CSR Item No.14.3 ) |
| 39 | Ceiling Lights 600x600mm . ( CSR Item No. MR) |
| 40 | Stripping and stacking iron sheets of a roof including ridging, flashing, eaves boards gutters and down pipes. ( CSR Item No. 8.11) |
| 41 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.( CSR Item No.8.46 ) |
| 42 | Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. ( CSR Item No.18.53 ) |
| 43 | steel Work Fixed independently without connecting plates including cutting hoisting and Fixing in positon tees angles & channels . ( CSR Item No.18.1 © ) |
| 44 | Steel work in hip & jack rafters common rafters purlins etc. with angle cleats and other connecting plates. ( CSR Item No. 18.2) |
| 45 | Structural steel work in compound girders or Stanchions built up from two or more R.S. joists or channel section or plates & angles etc. including cutting and fixing all lattice bars, stiffeners, gusset plates, bolts, nuts, rivets, welding rod, etc. complete with flange plates, heads, sole plates, angle connections, etc. with hoisting and erecting in position. ( CSR Item No. 18.7) |
| 46 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5- 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (b) 0.60 mm (+ 0.05% ) thick. ( CSR Item No.13.27 ii (b) ) |
| 47 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. ( CSR Item No. 16.2) |
| 48 | Painting two or more coats with aluminum paint to give an even shade excluding priming coat. ( CSR Item No. 16.25) |
| 49 | A. ASPHALT BASE FOR OUTDOOR RECREATIONAL SURFACE . A. Dressing of soil after removing existing grass and weeds . B. Brick work around the court. C. Compaction of the sub base will be by 8-10 ton roller. D. Carry out anti-termite and weedicide on the total area by spraying. E. Lay a layer of 53mm/ 40mm compacted water bound macadam in two layers respectively of 3\\". WBM to be densely compacted by keing and inter locking the stones to ensure that no settlement takes place. F. Lay a 30 mm compacted thick hot mix Asphalt BM course. G. Lay a 20 mm aggregate mixed with dust compacted thick hot mix A.C course. H. Concrete slope to all sides of the court to seal it. ( NS. ) |
| 50 | B. Kyrocryl 8 layers ultra cushion flooring (FIBA standard). In this system one layer primer, one layer resurfacer, two layer of heavy cushion, two layer of fine cushion, one layer of kyrocryl acralyic texture coat, one layer of kyrocryl acrylic finish top coat with game line marking on complete court as per the specification given by federation Internationale de Basket ball Amaeteur. Primer for proper bonding between the floor and the resurfacer for better strength of the synthetic floor. Good quality synthetic material with binders, surfaces, all weather shield cushion coating. ( NS) |
| 51 | C. Basketball fixed poll set in M.S pipe 6 inch (20 mm acrylic board ) Acrylic board size standard (1800 x 1050 mm ) with normal ring and complete set. ( NS) |
| 52 | D. Chain Link Fencing . 2\\"x 2\\" G.I chain link fencing with 10' height. All vertical poll are 50nb with 14 gauge and horizontal pipes are 40nb with 14 gauge price including primer and paint. ( NS) |
| 53 | E. M.S pipe of 3 & 2 inch, 22 feet above the ground & 3 feet inside the ground, 200 watt led light per pole with wiring and MCB. ( NS) |
| 54 | Cement Concrete 1:2:4 with stone ballast or shingle (ii) using mechanical means using concrete mixer volumetric type.( CSR Item No.10.13 a (ii) ) |
| 55 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension on higher side shall be accepted but no extra payment on this account shall be made. (g) fixed window / ventilator made of (small series) frame 47x50 mm & mullion 47x68 mm both having wall thickness of 1.9+=0.2 mm and single glazing bead of appropriate dimesnion (Area upto 0.75 sqm). ( CSR Item No. 33.18 (g)) |
| 56 | Dismantling brick work tile, masonry or tile lining (b) in cement . ( CSR Item No. 8.5 (b)) |
| 57 | Removing of re-fixing of M.S iron grill . (AOR) |
| 58 | Extra rates for white washing, distempering, painting and decorative cement based paints etc for superstructure Where any single storey height exceeding 4 mtr in height for every additional height of 2 mtr or part thereof (External or Internal) ( CSR Item No.16.72 ) |
| 59 | Scraping (a) Cement plaster. ( CSR Item No. 8.31 (c)) |
| 60 | Dismantling concrete (d) Cement concrete plain1:2:4 mix.( CSR Item No.8.6 (d) ) |
| 61 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10sqm ( CSR Item No. 16.6 ) |
| 62 | Supply of Brick tiles . ( AOR ) |
| 63 | Supply and fixing of toughened glass 8 mm thick .( M.R) |
| 64 | Supply and fixing of Sealent for joins in ACP sheets.( M.R) |
| 65 | Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. ( CSR Item No.14.87 ) |
| 66 | PART-B (WATTER SUPPLY ITEMS) |
| 67 | Dismantling sanitary fixtures such as European/Indian/Orissa W.C., PVC/ China ware cistern, Wash hand basin, Urinal Pot, Sinks and CP fittings and disposal of dismantled material within a distance of 100 mtr. Completein all respect as required by Engineer-in-charge (CSR item No. 30.88(a)) Europeon Indian/Orissa W.C. |
| 68 | Dismantling sanitary fixtures such as European/Indian/Orissa W.C., PVC/ China ware cistern, Wash hand basin, Urinal Pot, Sinks and CP fittings and disposal of dismantled material within a distance of 100 mtr. completein all respect as required by EIC.(CSR item No. 30.88(b)) PVC/China Ware Cistern. |
| 69 | Dismantling sanitary fixtures such as European/Indian/Orissa W.C., PVC/ China ware cistern, Wash hand basin, Urinal Pot, Sinks and CP fittings and disposal of dismantled material within a distance of 100 mtr. Completein all respect as required by Engineer-in-charge (CSR item No. 30.88(c)) Wash hand basin / urinal pot. |
| 70 | Dismantling sanitary fixtures such as European/Indian/Orissa W.C., PVC/ China ware cistern, Wash hand basin, Urinal Pot, Sinks and CP fittings and disposal of dismantled material within a distance of 100 mtr. Completein all respect as required by Engineer-in-charge (CSR item No. 30.88(e)) CP brass bib cock/ Angle cock/ Stop cock/shower/bottle trap. |
| 71 | Dismantling sanitary fixtures such as European/Indian/Orissa W.C., PVC/ China ware cistern, Wash hand basin, Urinal Pot, Sinks and CP fittings and disposal of dismantled material within a distance of 100 mtr. Completein all respect as required by Engineer-in-charge (CSR item No. 30.88(f)) wall mixer/sink mixer/basin mixer/concealed stop cock . |
| 72 | Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings compete in all respect.(CSR item No. 28.63(a)) 15mm internal diameter pipe line . |
| 73 | Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings compete in all respect.(CSR item No. 28.63(f) )50 mm internal diameter pipe line |
| 74 | Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings compete in all respect.(CSR item No. 28.63 (h)) 80mm internal diameter pipe line |
| 75 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. (a) 15mm i/d. ( CSR Item No.28.36 (a)) |
| 76 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. (f) 50mm i/d labour rate . ( CSR Item No.28.36 (f)) |
| 77 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. (h) 80mm i/d labour rate . ( CSR Item No. 28.36 (h)) |
| 78 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. ( CSR Item No.30.4 ) |
| 79 | Providing and fixing Stainless steel health faucet complete in all respect.( CSR Item No.30.24 ) |
| 80 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. (a) with C.P brass nut. ( CSR Item No.30.8 (a) ) |
| 81 | Providing and fixing in position vitreous Chinaware white Indian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. ( CSR Item No. 30.16) |
| 82 | Providing and fixing partition for different type of urinals. (a) (iii) Toughned glass partition 8 mm thick size 450x900 mm C/S. ( CSR Item No.30.21 (a) (iii)) |
| 83 | Providing and fixing in position C.P. Brass Urinal button flusher 15 mm of approved make (to the approval of Engineer-in-charge). ( CSR Item No. 30.36) |
| 84 | Providing and fixing in position C.P brass basin mixer without pop-up waste system with 450 mm long flexible hose of approved make (to the approval of Engineer-in-charge) instead of C.P. brass pillar tap complete in all respect. ( CSR Item No. 30.38) |
| 85 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. (a) C.P brass towl rails size 15mm dia 610 mm long .( CSR Item No.30.58 (a) ) |
| 86 | Providing & Fixing in position mirror of superior glass Size 1500mm x600mm or any other required size (of approved quality) and of required shape and size with high quality polystyrene moulding frame of 40 to 50mm size (of approved quality and shade) with 4mm thick hardboard backing fixed in with rawl plugs 50mm, C.P. brass screws and washers complete in all respect.( CSR Item No.30.62 (b)) |
| 87 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. ( CSR Item No.30.64 (A) ) |
| 88 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.(a) C.P brass 15 mm stop cock male and female end .( CSR Item No.30.66 (a) ) |
| 89 | Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect. (a) C.P brass liquid soap container .( CSR Item No.30.67 (a) ) |
| 90 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. (a) PVC tube connection of size 15 mm x 450 mm with C.P. brass nut .( CSR Item No.30.72 (b) ) |
| 91 | P&F in position S.S. grating with frame of approved make (to the approval of Engineer-in –Charge) complete in all respect) (CSR item no.30.80) |
| 92 | Cutting chase in brick walls in cement or in floor for embedding GI or CI pipes lines land making good the same to its original condition. (CSR item no. 30.85 a ( iii))75mm to 75 mm |
| 93 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. iii) size 630x450x830 mm. ( CSR Item No.30.31 ) |
| 94 | Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineerin-charge) complete in all respect.( CSR Item No. 30.44) |
| 95 | Providing, fixing and jointing G.I. union coupling (of approved make with the approval EIC) as per IS:1879 in G.I. pipe lines compete in all respect. CSR item No. 28.40a) 15mm i/d GI Union. ( CSR Item No.28.40(a)) |
| 96 | Providing, fixing and jointing G.I. union coupling (of approved make with the approval EIC) as per IS:1879 in G.I. pipe lines compete in all respect. CSR item No. 28.40 f) 50mm i/d GI Union. |
| 97 | Providing, fixing and jointing G.I. union coupling (of approved make with the approval EIC) as per IS:1879 in G.I. pipe lines compete in all respect. CSR item No. 28.40 h) 15mm i/d GI Union. ( CSR Item No.28.40(f)) |
| 98 | Providing and placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make ( to the approval of EIC) with covr with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank Triple layer tank ( CSR Item No. 30.97-A (i)). |
| 99 | P&F in position GI tank nipple of approved make ( to the approval of EIC) in PVC water storage tanks complete in all respect. GI tank Nipple 15mm i/d. ( CSR Item No.30.98( a)) |
| 100 | P&F in position automatic brass ball cock in tanks. Brass ball cock with rod and plastic ball 15mm i/d. ( CSR Item No.30.96 b (i)) |
| 101 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete as per CSR item No. 28.44 (a) 15mm i/d brass ball valves |
| 102 | Excavation manually in trenches with straight or open cutting in built up street/ lane having wall to wall width of street/ lane upto 3.0 metre, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto, to full dimensions and depth as shown on the drawings or as shall be required by Engineerin-charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic. Providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15m and for all lifts and subsequent refilling, watering and dressing upto groung level, including removal of surplus spoil from the site upto 15 metre distance complete in all respects.(i) all classes of soil except rocky. ( CSR Item No.29.1 A (i)) |
| 103 | Cement Concrete 1:8:16 (b)with stone aggregate40mm gauge (ii) Mixing by mechanical means using concrete mixer volumetric type. ( CSR Item No.10.6 b (ii) ) |
| 104 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. (B) single socket Type B (b) 110 mm o/d SWR UPVC pipe lines laid complete. ( CSR Item No.30.74 iii (B) b )) |
| 105 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. (B) single socket Type B (c) 90 mm o/d SWR UPVC pipe lines laid complete. ( CSR Item No.30.74 iii (B) c)) |
| 106 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. (ii) coupler. ( CSR Item No. 30.81 (iii) B (viii)) |
| 107 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. (iii) Elbow 90 degree (All sides socket ) . ( CSR Item No.30.81 (iii) B (v)) |
| 108 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. (iv) P trap/floor Trap 100 mm x 75 mm . ( CSR Item No. 30.81 (iii) B (x)) |
| 109 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. (b) 100 mm internal diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. with frame clear cover 300 mm x 300 mm anf out side size 330 mm x 330 mm . ( CSR Item No.30.99 (b)) |
| 110 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floor with cement concrete 1:2:4 mix (1 cement :2 concrete sand : 4 : graded stone aggregate 20mm nominal size) cement plastered on both side with cement mortar 1:2 (1cement : 2 coarse sand ) finished with a floating coat of neat cement and making necessary channals for the drain etc. complete. (a) For pipes 100 to 250mm Diameter. ( CSR Item No. 29.65 (a)) |
| 111 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. (a) size 450mmx450mm inside with RCC 455mmx455mm cover and frame light duty double seal. ( CSR Item No. 29.6) |
| 112 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. (a) M.S holder bats clamps for 100 mm i/d H.C.I pipes. ( CSR Item No.30.78 (a)) |
| 113 | ELECTRICAL ITEMS |
| 114 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring fan point (Without fan box)(CSR item No.34.02 item i (a)). |
| 115 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring light pointCSR item No.34.02 item (ii). |
| 116 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring call-bell point CSR item No.34.02 item (iii). |
| 117 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring 6Amp. wall socket pointCSR item No.34.02 item (iv). |
| 118 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring 16/20Amp. power plug control point CSR item No.34.02 item (vi). |
| 119 | PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1sq.mm (Un-sheathed) CSR item No.34.09 (i). |
| 120 | PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (Un-sheathed) CSR item No.34.09 (i). |
| 121 | PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 2.5sq.mm (Un-sheathed) CSR item No.34.09 (iii). |
| 122 | PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 4sq.mm (Un-sheathed) CSR item No.34.09 (iv). |
| 123 | PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 6sq.mm (Un-sheathed) CSR item No.34.09 (v). |
| 124 | SURFACE AIR CONDITIONER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of air conditioner supply terminal point on surface on wall etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having 25Amp. Combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2 Module), covered with Frame Plate etc., & including the cost of above material and other petty material with necessary connections etc.:-Wiring AC supply terminal point having 1 No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. CSR item No 34.07 ix . |
| 125 | Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring TV socket point (one module)CSR item No.34.01 item xi (a). |
| 126 | XLPE INSULATED ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminum conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 16sq.mm (2Core) Armoured(Loose) CSR item No.34.10 B (iii). |
| 127 | XLPE INSULATED ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminum conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 35sq.mm (31/2. Core) Armoured(Loose) CSR item No.34.10 B (xxiii). |
| 128 | XLPE INSULATED ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminum conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 300sq.mm (31/2. Core) Armoured(Loose) CSR item No.34.10 B (xxxi). |
| 129 | Supply and Erection of Post Top luminaries of appropriate make with 9 watt LED Lamp on existing pole including connection with single core copper cable 1.5mm2 with petty material required for erection as per AOR |
| 130 | Supply and Erection of outdoor water proof garden light of 1000mm height from the ground level with 15/16 watt LED Lamp including connection with single core copper cable 1.5mm2 and making of suitable concrete pedestal with required number of boards duly grouted. The light will be approved form the engineer in charge before installation as per AOR |
| 131 | Supply and erection of LED flood light luminaries of 150 watt including connection with single core copper cable 1.5mm2 with petty material required for erection as per AOR |
| 132 | Supply and erection of LED street light of 30 watt including connection with single core copper cable 1.5mm2 with petty material required for erection of exiting street light pole having street light bracket made of 2” GI pipe as per AOR |
| 133 | Supply and erection of LED Panel light of 2’x2 of 40/36 watt luminaries including connection with single core copper cable 1.5mm2 with petty material required for erection as per AOR |
| 134 | Supply and erection of LED Tube light of 4’ of 22 watt luminaries including connection with single core copper cable 1.5mm2 with petty material required for erection as per AOR |
| 135 | Supply and erection of LED Bulb of 5/6 watt luminaries including connection with petty material required for erection as per AOR |
| 136 | Supply and erection of LED Bulb of 9 watt luminaries including connection with petty material required for erection as per AOR Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail