| 1 | Items : |
| 2 | Excavating over area, n exc 1.5 m deep getting out in soft/ loose soil as per SSR & as dir by E in C. |
| 3 | Excavating over areas, n exc 1.5 m deep getting out in hard/dence soil as per SSR & as dir by E in C. |
| 4 | Demolition of Concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) as per SSR & as dir by E In C. |
| 5 | Excavating over areas in soft /loose soil, add to items 03004 for each additional 1.5 m or part therof in depth beyond the first 1.5 m and getting out as per SSR & as dir by E in C. (max depth 0.75 mtr for earth pit) |
| 6 | Excavating over areas in hard/dense soil, add to items 03004 for each additional 1.5 m or part therof in depth beyond the first 1.5 m and getting out as per SSR & as dir by E in C. (max depth 0.75 mtr for earth pit) |
| 7 | Shingle filling in floor or pavings, laid in layers n exc. 15 cm thick, spread, levelled, and blinded with earth and rammed including watering as per SSR and As dir. by E in C. |
| 8 | Laid dry bricks, sub class ‘B' laid flat, in floors, old size brisks as per SSR & as dir by E in C. |
| 9 | Tubes, 'light grade , galvanised with all fittings laid in trenches bore of the tube 40 mm as per SSR & as dir by E in C. |
| 10 | Reinforced concrete pipes, class NP2, laid and jointed complete with collars, bore of pipe 150 mm as per SSR & as dir by E in C. |
| 11 | Supply & laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 core 10 sq. mm stranded conductor nominal cross-section in service connections as per SSR & as dir by E in C. |
| 12 | S&F of Wiring for ciircuit/submain wiring alonwith earth wire with the 4x2.5 sq.mm of FR is PVC insulated copper conductor single core cable in surface/recessed as requiredin PVC conduit as per SSR & as dir by E in C. |
| 13 | M&L of broken stone or boulders loose filling with aggregates of gauge 40 to 80 mm in soakage pits, soakage wells as per SSR & as dir by E in C. |
| 14 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm. in soft/ loose soil/ hard/ dence soil as per SSR and as dir.by E in C. |
| 15 | M&L of earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate n. less than 1.5 mtr below normal ground level connected to galvanised iron strip as a earthing lead of size 25 x 4 mm by means of bolts, nuts,chuck nuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion as per SSR & as dir by E in C. |
| 16 | TMT bars 8 mm dia & over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as per SSR & as dir by E in C. |
| 17 | Formwork to sides of pillers, posts, struts, piers, colums & stanchions square, rectangular or polygonal rough finished surfaces of concrete as per SSR & as dir by E in C. |
| 18 | Cement concrete in foundation , filling and mass concrete Type C2 1:3:6 ( 40 mm graded aggregated) as per SSR & as dir by E in C. |
| 19 | S & F of Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') as per SSR & as dir by E in C. |
| 20 | S & F of mild steel plianed black sheet in wall cladding, and similar work cut to size, holes punched; including round headed screws clout nails and revets and fixed to wood or steel framing with plain 40 mm lap joints with reveted or welded seams, including bendingor turning up, mitred angles, etc. as required thickness of sheet 1.60 mm as per SSR & as dir by E in C. |
| 21 | Compression / crimping type sleeve joint for jointing conductors / jumper connections including treatment with conducting jelly up to 10 mm dia of conductor ,wire overall M & L as pe SSR & as dir by E in C . |
| 22 | Supply of GI Octagonal pole 12 mtrs as per Diamension: Top - 100 mm, Bottom Dia - 240 mm, Section - 2 (section length - 6200 mm each) Thick - 3 mm each with Base Plate - 350x350x20 mm P.C.D. 350 mm, Base plate hole dia suitable for M24 foundation bolts etc as per OFV drawing No.V/SK/1226 & dir. by E in C. |
| 23 | Supply & fixing of GI bracket for 6 street/flood light fitting on each pole complete with required material as per Ofv drawing No. V/SK/1227 & dir. by E in C. |
| 24 | Supply & fixing LED flood flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistance complete with driver and lamp as per SSR & as dir by E In C. |
| 25 | Foundation of 12 Mtr octagoanl pole with excavation,reinforced steel, concrete & foundation bolts as per OFV drawing No. V/SK/1228 & as per dir. by E in C. Please Enable Macros to View BoQ information |