| 1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 2 | 3 x 2.5 sq. mm (DSR ref. 1.17.12) |
| 3 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 4 | 25 mm (DSR ref. 1.21.2) |
| 5 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 1 run of Cable (DSR ref. 1.53.1) |
| 7 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 8 | 6 way (4 + 18), Double door (DSR ref. 2.4.2) |
| 9 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 10 | Single pole (DSR ref. 2.10.1) |
| 11 | Supply and erection of 63 amp MCB TPN C series 10KA including connections make legrand, L&T Schenider, hager complete in all respect to the enitre satisfaction of the Engineer-in-Charghe. (NS) |
| 12 | S/E/T/C of manageble network switch enterprises segment 24 port with POE 1x100 mbs speed or above complete in all respect to the entire satisfaction of the Engineer-in-Charge. Make:- Cisco/Uniper/Aruba. (NS) |
| 13 | Supply and erection of 22U rack on existing wall in any height including lead and lift complete in all respect to the entire satisfaction of the Engineer-in-Charge. Make:- Combrac/Netfox/Mass rack (NS) |
| 14 | Supply and erection of I/O (input/output) link including cost of box for the same in any height including lead and lift. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. Make:- D-Link/ Schenider/Goldmedal. (NS) |
| 15 | Supply and erection of patch panel 24 port with required material in any height including lead and lift. Complete in all respect to the entire satisfaction of the Engineer-in-Charge.Make:- D-Link/ Hickvision/Schenider (NS) |
| 16 | Supply and erection of patch cord with connector on both end in any height including lead and lift. Make:- D-Link/ Hickvision/Schenider (NS) |
| 17 | Penta scanning of internet points with the help of penta scanning machine including labour charges to operate it. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 18 | Supply and erection of computer point with 3x5 amp with required modular plate on the running trunking on the computer tables. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 19 | Supply, Installation, Testing & Commissioning of 2-way, Ceiling- mount loudspeaker. Frequency range - 65 Hz to 20 kHz, Rated RMS Power-30Watts or better, Sensitivity-89 dB SPL or better, Coverage Angle-110° conical or better, Maximum SPL Continuous/Peak- 104dB/110dB or better, Rated Impedance - 8 Ohms. Transformer Tapping-70V/100V(30, 15, 7.5watts) or better. Transducer - LF- 6.5-inch or better, HF-.86-inch or better coaxially mounted with LF, Material - Painted ABS polymer Baffle and Power coated steel grille or better. Safety rating - UL1480, UL2043. Mounting rails and C-Ring for ceiling tile included. make QSC/Bose/Martin/JBL/Bosch. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 20 | Supply, Installation, Testing & Commissioning of Quad channel class- D amplifier with minimum 60 watts/channel into Low-Z loads. Four channels can also be bridged in pairs, each pair providing up to 100 watts rms into 4/8 ohms or 125 watts rms into 70V/100V or better. Signal to Noise (A weighted, 20 Hz-20 kHz)->100 dB or better, Frequency Response-20 Hz - 20 kHz or better, Input Sensitivity-1.23 Vrms (+4 dBu) or better, Input Impedance->10 ΚΩ (balanced), >10 ΚΩ (unbalanced) or better, Front Panel Indicators-Power, per channel Signal, per channel Protect/Limit, Controls-4Ω/8Ω/70V Bridge Highpass On/100V Bridged Highpass on per channel pair. Should be Energy star rated. Size half RU with rack mounting hardware included.make QSC/Bose/Martin/JBL/Bosch. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 21 | Supply, Installation, Testing & Commissioning of Open Architecture Digital Signal Processor with minimum 16 Mic/Line inputs and 8 Line outputs. Shall support phantom power on each microphone input. AEC channels - 16 or more with 200ms tail length for analog & network audio. Minimum 8x8 Dante channels and support for up to 128x128 Network audio channels via Dante /AES67 or similar protocol. POTS and SIP Softphone integration for Audio conferencing. USB-B port supporting (NS) |
| 22 | AV USB Bridging for sofware or web-based conferencing applications emulating USB Audio (Speakerphone) and USB video (Camera) driver - 24 bit-A/D-D/A converter or better, 48kz sample rate or better, input frequency response of 20 Hz to 20 kHz or better, input dynamic range> 109 dB or better. make QSC/Bose/Martin/JBL/Bosch. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 23 | Supply, Installation, Testing & commissioning of Chairman unit Frequency response 200 Hz to 12.5 kHz, Headphones load impedance > 32 ohms < 1k ohm, Loudspeaker nominal output 72 dB SPL, Mechanical Dimensions device without microphone (H x W x D) 64 x 203 x 146 mm (2.5 x 8.0 x 5.7 in), Height with microphone in horizontal position 130 mm (5.1 in), Length of microphone from mounting surface CCSD-DL: 480 mm (18.9 in) Make: Bosch /Sennheiser/Beyerdynamic. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 24 | Supply, Installation, Testing & Commissioning of Cable Manager with HDMI LAN & USB-C Connectivity. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 25 | Supply, Installation, Testing & Commissioning of 4K Network PTZ Conference camera with minimum 12x optical zoom & 80-degree horizontal coverage. Low Noise CMOS 4K image sensor with User- configurable resolution and quality for IP streams (up to 1080p). HDMI resolutions up to 4K30 or better and SDI-3G resolution up to 1080p60 or better. Image rotation controls to allow for inverted mounting using ceiling bracket. Minimum Illumination - 0.5 Lux @ (F1.8, AGC ON) or better, Horizontal Rotation Range - ±170°, Vertical Rotation Range -30° to +90° or better, White Balance controls-Auto, indoor, outdoor, one-push, manual, specified color temperature or better. Camera should be able to transmit video via network to USB endpoint connected for video conferencing. Power - PoE & AUX. Shall include wall mounting bracket included, make QSC/Polycom/Cisco. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 26 | Supply, Installation, Testing & Commissioning of Network Video Endpoint configured as Encoder. Minimum Inputs - 1 x HDMI Input and 1 x USB-C for single cable connectivity for Video encoding, AV USB Bridging - emulating webcam video and AEC speakerphone audio driver for Software based Video Conferencing and for charging the connected device. Local Output 1x HDMI with Scaling, HDMI audio embedding and deembedding, Network Audio supported via Dante/AES67 or similar protocol, Video Resolution - 4K60 4:4:4 or better. Power - PoE and AUX, Control Port - RS232 or better, Mounting hardware included. make QSC/Polycom/Cisco. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. |
| 27 | Supply, Installation, Testing & Commissioning of Network Video Endpoint configured as Decoder. Outputs - 1 x HDMI with scaling or better. Local inputs - 1xHDMI and 1 x USB-C for local switching Audio embedding and deembedding, Network Audio supported via Dante/AES67 or similar protocal. Video Resolution - 4K60 4:4:4 or better, Power - PoE and AUX, Control Port - RS232 or better, Mounting hardware included make QSC/Polycom/Cisco. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. |
| 28 | Supply, Installation, Testing & Commissioning of Wireless Presenter Device make Barco/Crestron/Extron. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. |
| 29 | Supply, Installation, Testing & Commissioning of High Definition Multi-touch Touch Screen Controller with 24-bit color display viewable screen Dimension (diagonal) - 7-inch or better, Resolution -1280x800 or better, Brightness - 400 nits or better Aspect ratio - 16:10 or better, Power - PoE or better, Mounting- Wall and Tabletop, Orientation - Vertical/horizontal, Configurable LED's on both side or similar for status indication, sensors- Ambient light Sensor, Proximity Detection or better. Make Barco/Crestro/Extron. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 30 | Supply, Installation, Testing & Commissioning of Hardware or software based control system with required ports to control the devices mentioned in BOQ with perpetual licenses to connect Wall/ Table mount touch screen controllers and iOS and Windows devices as wireless touch controller, make Barco/Crestron/Extron. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 31 | Supply, Installation, Testing & Commissioning of minimum 10 Port network switch with 10/100/1000 Mbps half/full duplex ports on RJ45 connections. Minimum 8 PoE++ (90W) ports with up to 720 Watts total power budget. Two 10 Gbps SFP/SFP+ ports. Layer 2 and Layer 3 managed (non-blocking) and preconfigured with appropriate quality of service (QoS) for use with related network AV technologies like Dante/AES67 for audio, video, and control networks. It shall provide IGMP snooping and IGMP querying for networked audio and video multicast traffic. An inbuilt DHCP server shall be preconfigured for optional use in applications requiring automatic device addressing. Internal power supply with a rear panel IEC power input socket for 120-240 VAC. Mounting Accessories to be included. .make Barco/Crestron/Extron. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 32 | Supply, Installation, Testing & Commissioning of All required Cables and Connectors: Speaker Cable, Microphone Cable/Signal Cable, Antenna Cables, STP Cat6. make Barco/Crestron/Extron. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 33 | Supply, Installation, Testing & Commissioning of AV Rack or Credenza 15U make NetRack/Comrack. Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) Please Enable Macros to View BoQ information |