| 1 | Excavation in foundation , trenches etc. in earth work lift upto 1.50 mtrs. Stacking the excavated soil not more than 3 mtrs. Clear from the edge of excavation and than returing the stacked soil in 15cm layers, when required into plinth, sides of foundation etc. Consolidationg each deposited ayer by ramming and watering and then disposing of all surplus excavated earth directed within all lead & lift as per direction & satisfaction of the Engineer-in-charge. |
| 2 | Providing, Laying, Jointing & testing in trenches following dia, and grade having suitable pressure 4.00 Kg/Cm2 working pressure polythene pipe high density confirming to IS: 4984-1995 complete with special flange compression type fittings (Earth work in trenches to be measured and paid for separately) with in all leads and lifts as per direction & satisfaction of the Engineer-in-charge. |
| 3 | 250mm dia HDPE pipe grade PE-80 PN4 |
| 4 | 225mm dia HDPE pipe grade PE-80 PN4 |
| 5 | Providing, fixing, testing and comissioning of LETBXU 7PA 6J0 street light high quality costum moulded polycarbonatediffuse cover output short circuit over voltage surge and phase to phase protection high effeciency long life LED with raw powder coated metallic silver finish cover perimeter / boundary lighting 50 watts 240 volts (PF>0.95 ) of GEC, philips, Bajaj, Havells or any other ISI approved brand and make including suitable angle clamps for fixing and any other fitting required for installation of lights complete in all respects as per direction and satisfaction of engineer in charge. |
| 6 | Supplying Round Cusions complete in all respects as per direction and satisfaction of engineer in charge. |
| 7 | Providing and installation of electric gyser 15 litres capacity as per relavent IS codes ( latest with up to date ammendments if any) of Havels, V.Guard, Crompton or any other IS approved brand including the cost of fixure at site within all leads and lifts as per direction and satisfaction of engineer in charge |
| 8 | Providing & fixing Electric Heat Blower (Havells Cista) as required complete in all respects as per direction and satisfaction of engineer in charge complete in all respects. |
| 9 | a) Havells Cista blower |
| 10 | Providing and fixing of Elecric Heater (ozone Carbon Heater for VIP Set) complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 11 | Providing and fixing of Elecric Heater Three rod complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge |
| 12 | Providing & fixing L& T automatic starter for Submersible pumping machinery manufactured by parental company comprising ML 4 contacts and MN relays, overload and single facing protection confirming to IS-13947-4 IEC-60947-4 along with testing certificate including pushing button auto start, auto stop and restart facility, ICT switches and all other electrical accessories which required for the job single phase preventor, 3-phase indicator, time, relay selector and Entire satisfication of the engineer- in -charge. |
| 13 | Providing & fixing L&T automatic Starter for Centrifugal pumping machinery manufactured by parental company comprising ML 4 contacts and MN relays, overload and single facing protection confirming to IS-13947-4 IEC -60947-4 along with testing certificate including pushing button auto start, auto stop and restart tacility, ICT switches and all other electrical accessories which required for the job single phase preventor, 3-phase indicator, time, relay selector and Entire satisfication of the Engineer-in-charge. |
| 14 | 15 HP |
| 15 | 100 HP |
| 16 | Providing and fixing PVC jointless flat water proof copper cable of finolex/Gloster as per BIS-1554 Part-I-1998 latest with upto date ammendments suitable for the pump sets offered i/c all other electrrical equipment/accessories such as thimbles flexible pipe solder nuts bolts cable, gland etc laid in pipe for trenches under floor. The type & size will be subject to approval of HPSEB authority in case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer without extra cost ) as per the entire satisfaction of the Engineer In charge. |
| 17 | 3 Core Cable 25mm sqare |
| 18 | 3 Core Cable 10mm sqare |
| 19 | 3 Core Cable 6mm sqare |
| 20 | Providing and Supplying of Transformat Oil complete in all respect. |
| 21 | Providing and fixing of Cast Iron Sluice valve of following dia ISI marked made Kirlosker PN 1.00 conforming to IS (14846-2000) latest with up to date ammendements, both side flanged T-17 including cutting, welding, gasket sheet 3mm thick champion make nut, bolt complete in all respects with in all lead and lifts as per direction & satisfaction of Engineer - in - charge. |
| 22 | 150mm dia |
| 23 | 100mm dia |
| 24 | 80mm dia |
| 25 | 65mm dia |
| 26 | Providing and Fixing of Main Switch box 250 Amp. of sputnik make Complete in all respect with in all lead and lifts as per direction & satisfaction of Engineer - in - charge. |
| 27 | Providing and Fixing Voltmeter 0-500 volt Complete in all respect with in all lead and lifts as per direction & satisfaction of Engineer - in - charge. |
| 28 | Providing and Fixing of Amp. Meter 0-100Amp. Complete in all respect with in all lead and lifts as per direction & satisfaction of Engineer - in - charge. |
| 29 | Supply of submersible pumping set of (KSB/Kalama/Kirloskar/Johnston/Cromption/BS) make conforming to BIS; 8034-1976 latest suitable for lifting clear water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- |
| 30 | Total Head :- 150.00 mtr |
| 31 | Discharge required from each pump. :- 6.99 LPS |
| 32 | Transportation of rig along with allies accessories etc. complete including erection & levelling at site through all kind of roads, approaches field etc. in all lead & lift |
| 33 | Flushing of Tube well by continuous over pumping method with V.T pumps, Submersible pumps of suitable capacity not less than double the discharge established by the compressor method/design discharge, untill the well sand free as per IS-11189-1985 with upto date ammendments, if any complete in all respect as per the direction of Engineer-in-charge. The drawdown & discharge to be established by running the VT/Submersible pump continuously for 30Hours in the presence of the officer not less than the rank of Assistant engineer |
| 34 | Providing and laying cement concrete work 1:4:8(1cement:4sand: 8 graded stone aggregate 40mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in foundation and plinth |
| 35 | Brick work using common burnt clay building bricks (Ist class) in foundation and plinth in cement mortar 1:4 (1cement:4 sand) in all leads and lifts. |
| 36 | Cement concrete flooring 1:2:4(1cement:2sand:4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement (40mm thick) in all leads and lifts. |
| 37 | 15 mm thick cement plaster in single coat on fair side of brick/ stone masonry/concrete for interior plastering upto floor two level including arrises internal rounded angles cement mortor 1:3 ( 1 cement:3 sand ) |
| 38 | Providing Tor steel reinforcement for RCC work including bending,binding & placing in position complete upto floor two level |
| 39 | Item No. 11 Rabate 3% Please Enable Macros to View BoQ information |