| 1 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping site for lead upto 10 km periphery area for all lifts, complete as per directions of Engineer-in-charge. |
| 2 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m Ordinary rock as per the diretion of Engineer in Charge at site. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Tata/Sail/Jindal Panther/Shyam steel or as approved by HPPWD. Thermo-Mechanically Treated bars of grade Fe-500D or more as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 8 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 9 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 10 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like Cement mortar 1:6 (1 cement : 6 coarse sand) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 11 | Providing Sal wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 12 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick 5.0 mm thick glass panes (weight not less than 12.5 kg per sqm) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 13 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screw as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 15 | Providing and fixing 35 mm thick Second class teak wood shutters wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 16 | Providing and fixing 50 x 20 mm wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 17 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 18 | 20 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 19 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two or more coats on new work as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 20 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 21 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 22 | Painting Two or more coats on new work with synthetic enamel paint of approved brand and manufacture to give an even shade as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 23 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 24 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 25 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. 75 mm diameter |
| 26 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking the useful material in specified manners as per the direction of Engineer-In-Charge and disposal of unserviceable materials in all leads and lifts. Of area beyond 3 sq. metres. Please Enable Macros to View BoQ information |