| 1 | Supplying and laying of following PVC insulated and PVC sheathed /XPLE armounrd Aluminum Conductor power cable of 1.1 KV grade of following size in the existing RCC/ HUME/DWC/METAL/Open Duct pipe as required. |
| 2 | 3 X 10 Sq. mm armounrd Aluminum conductor power cable |
| 3 | Supplying & Fixing of 3 X 4 Sq. mm Unarmounrd Aluminum conductor cable |
| 4 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 5 | 200 Watt |
| 6 | LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 4000°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. system lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 7 | 200 Watt |
| 8 | Supplying and Fixing pole box with hot press mounted SMC pole box of inside dimension 250mm x 250mm x 160mm deep having hinged cover with MS clamp of size 25mm x 5mm flat iron (NS) Nut and bolt washers etc. including suitable locking arrangement and 1no.SPMCB with all accessories mounting system and 3 phase aluminum backlight connector 16amp capacity for terminating of 3 phase cable including gasket connection complete etc. as required |
| 9 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 10 | 125 A,36KA, FPMCCB |
| 11 | 250 A,36KA, FPMCCB |
| 12 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 13 | Fabricating, Supplying and fixing wire mesh protection frame work made out of 40 mm x 6 mm thick angle and \\"T\\" strengthened with intermediate menberers of MS flat iron of size 30 mm x 5 mm thick welded at a distance of 30 cm horizontally and vertically and duly welded with wiremesh of size 75 mm x 25 mm made with 6 SWG wire mesh of size 75 mm x 25 mm made with 6 SWG wire on all sides and top i/c providing and fixing of double door gate with double locking arrangement ( Two nos. sliding bolts and one No. go down lock) having 0.5 mtr long legs of 40 mm x 40 mm x 6 mm thick angles iron, duly grouted in cement concrete foundation ration 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate) upto suitable depth painting with on coast of red oxide & two coats of synthetic enamel paint of approval colour and shade etc. complete as reqd. |
| 14 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. |
| 15 | 4 X 16 sq. mm |
| 16 | 4 X 25 sq. mm |
| 17 | 3½ X 50 sq. mm (35mm) |
| 18 | Providing & Fixing PVC insulation tape upto 30 cm on all the four core of existing 1.1 KV grade aluminium power cable in order to avoid any exposed surface touching the poles complete testing on load etc. as required. |
| 19 | Providing & Fixing 200 GSM (thick) tarpauling (white Colour) sheet of not less than 6ft x 6ft in the existing 8/10/12 mtr. pole with the help of suitable size of adhesive tape in order to avoid any current leakage complete water proof sealing complete etc. as required. Please Enable Macros to View BoQ information |