| 1 | Labour only for attending the emergent complaint of DG sets of 7.5 KVA to 320 KVA capacities including AMF Panel installed at various locations of air force station bhuj. Carrying out general servicing and minor repairs and/or replacements, including following jobs whichever is required to make DG Set functional complete all as specified and directed by Engineer-in-Charge :- (i) Checking and cleaning of diesel filters & oil filters and making a list of filters required to be replaced.(ii) Checking of engine oil level and intimating the quantity of oil required for topping, if any. (iii) Checking, cleaning and servicing including oiling & greasing of engine and making list of repairs / replacements required, if any. (iv) Checking, cleaning, watering & general servicing of alternator battery including tightening of nuts, bolts, lugs and the like. Also making a list of repairs / replacements required, if any.(v) Checking the earthing connections of neutral and body of DG set, tightening of connections and making a list of repairs / replacements required, if any. (v) Checking of DG set and AMF door hinges and do replace/repair to make its functional if required. |
| 2 | (vi) Checking of self starter and intimating Engr in charge if required to be repaired / specially serviced in workshop. (vii) Checking, cleaning and general servicing of AMF panel including replacement / tightening of nuts, bolts, lugs and other such minor parts, oiling & greasing and making list of repairs / replacements required, if any. (viii) Checking, cleaning & general servicing of instrument panel and making a list of repairs/ replacements required, if any. (ix) Checking, cleaning and general servicing of various parts of DG set such as timer, contactors , meters, etc. and making list of repairs / replacements required, if any. (x) Tightening / replacement of nuts, bolts, washers and the like of DG set all as directed. (xi) Checking for diesel leakage from any point and rectify if can be rectified by minor repairs / replacements. Else make list of repairs / replacements required, if any. (xii) Checking, cleaning and adjusting fan belt tension and making a list of replacements requirted, if any. (xiii) Checking, cleaning & general servicing of exhaust / silenecer including checking for leakage of smoke & rectify, if can be rectified by minor repairs / replacements. Else make a list of repairs / replacements required, if any. |
| 3 | (xiv) Checking, cleaning and tightenening of electrical connections including replacement of minor parts. (xv) Checking & cleaning of AVM pads, tightening / replacement of nuts, bolts, & washers and making a list of replacements required, if any. (xvi) Checking, cleaning & tightening of exhaust pipe, flange and lagging, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any. (xvii)(a). Checking output of alternator and adjusting the same to specified values, in case of brush type (b) cleaning & servicing of the alternator, minor repairs & replacements and making list of alternators requiring complete overhauling (xviii) Checking, cleaning & tightening of all hose pipes, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any. (xix) Checking, cleaning & servicing of air filter elements and making a list of replacements required, if any. (xx) Oiling, greasing and checking for proper functioning of DG set.(xxi) Review/Reset of time of all perimeter DG set (9 Loc) will be considered as one complaint. |
| 4 | Note - I. Rates quoted by the tenderer are also deemed to include the cost of supply & fix in replacement of minors parts like nuts, bolts, washers, lugs, etc., supply and applying oil & greasing and minor repairs to DG set. II. The work under this item is to be carried out as complaint recieved and as directed by the Engineer in charge. III. List of repairs / replacements prepared by the contractor shall be submitted to the Engineer in charge for verification. IV. The all mentioned above maintenance work carried out by contractor. |
| 5 | Material & labour for full servicing of DG Sets of capacity 7.5KVA to 63KVA complete all as specified and directed by Engineer-in-Charge as per following :-(i) Draining out engine/lubricant oil flushing including filling fresh oil afterdrain out old oil by skilled OEM trademan of DG set including replacement of oil pan /chamber gasket .(ii) Supply & fix in replacement lubricant oil filter element .(iii) Supply & fix in replacement fuel filter element.(iv) Supply & fix bypass filter element.(v) Checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc.(vii) Checking of belt tension and adjusting as per requirment.(viii) Check all electrical conditions.(ix)Check pollution level.(x) Change water separator and radiator cleaning with chemical.(xi) Change hydraulic governor oil, change aneroid oil, check aneroid adjustment, replace aneroid breather.(xii) Clean radiator externally, check fan hub/Idler and water pump/idler.(xiii) Inspect units, replace as required (Alternator/Generator,Starter etc), check air cleaner if required (Amount of air filter will be paid separately), evacuator valves change if required. Note- Servicing of DG set to be carried out by authorized firm and certificate of authorised dealership to be placed by the contractor prior to commence the servicing of DG set at site. |
| 6 | Material & labour for full servicing of DG Sets of capacity 70KVA to 160KVA complete all as specified and directed by Engineer-in-Charge as per following :-(i) Draining out engine/lubricant oil flushing including filling fresh oil afterdrain out old oil by skilled OEM trademan of DG set including replacement of oil pan /chamber gasket .(ii) Supply & fix in replacement lubricant oil filter element .(iii) Supply & fix in replacement fuel filter element.(iv) Supply & fix bypass filter element.(v) Checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc.(vii) Checking of belt tension and adjusting as per requirment.(viii) Check all electrical conditions.(ix)Check pollution level.(x) Change water separator and radiator cleaning with chemical.(xi) Change hydraulic governor oil, change aneroid oil, check aneroid adjustment, replace aneroid breather.(xii) Clean radiator externally, check fan hub/Idler and water pump/idler.(xiii) Inspect units, replace as required (Alternator/Generator,Starter etc), check air cleaner if required (Amount of air filter will be paid separately), evacuator valves change if required. Note- Servicing of DG set to be carried out by authorized firm and certificate of authorised dealership to be placed by the contractor prior to commence the servicing of DG set at site. |
| 7 | Material & labour for full servicing of DG Sets of capacity 200 KVA to 320KVA complete all as specified and directed by Engineer-in-Charge as per following :-(i) Draining out engine/lubricant oil flushing including filling fresh oil afterdrain out old oil by skilled OEM trademan of DG set including replacement of oil pan /chamber gasket .(ii) Supply & fix in replacement lubricant oil filter element .(iii) Supply & fix in replacement fuel filter element.(iv) Supply & fix bypass filter element.(v) Checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc.(vii) Checking of belt tension and adjusting as per requirment.(viii) Check all electrical conditions.(ix)Check pollution level.(x) Change water separator and radiator cleaning with chemical.(xi) Change hydraulic governor oil, change aneroid oil, check aneroid adjustment, replace aneroid breather.(xii) Clean radiator externally, check fan hub/Idler and water pump/idler.(xiii) Inspect units, replace as required (Alternator/Generator,Starter etc), check air cleaner if required (Amount of air filter will be paid separately), evacuator valves change if required. Note- Servicing of DG set to be carried out by authorized firm and certificate of authorised dealership to be placed by the contractor prior to commence the servicing of DG set at site. |
| 8 | Material & labour for preparing old painted surface of DG sets (complete including engine, alternator, body & chases) by thoroughly cleaning the surfaces to remove dirt, dust, rust flakes and paint flakes, using wire brush or sand papers, damp cloth or as directed. Priming the surface with anti corrosive primers using suitable sprayers. Applying automotive paint using sprayers till glossy finish is obtained, complete all as per manufacturers instructions and writting MES Number in block capital letters complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply only lead acid battereies for DG set complete all as specified and directed by Engineer-in-Charge of following capacity:-(Maintenance free battery of 2 years warranty) |
| 10 | 88 AH,12 Volt. |
| 11 | 150 AH,12 Volt. |
| 12 | 180 AH,12 Volt. |
| 13 | Repair and maintenance of FIP including replacement of Plunzers, Governer kit with pin, Nozzles P type,Head ball guide kit, Head sheet (set of 12 piece) rock rod, rollar bearing, oil seal, piston pin, gasket kit and sleeves complete all as specified and directed by Engineer-in-Charge DG set of following capacity:- |
| 14 | DG Set Upto 25 KVA |
| 15 | DG Set 30 to 50 KVA |
| 16 | DG Set 62.5 to 75 KVA |
| 17 | DG Set 82.5 to 100 KVA |
| 18 | DG Set 125 to 320 KVA |
| 19 | Material & labour for taking out radiator of DG set 7.5 KVA to 50KVA for repair, welding, brazing, leak testing, descaling & refixing to DG set to its original position and testing complete all as specified and directed by Engineer-in-Charge. |
| 20 | Material & labour for taking out radiator of DG set 62.5 KVA to 100 KVA for repair, welding, brazing,leak testing, descaling & refixing to DG set to its original position and testing complete all as specified and directed by Engineer-in-Charge. |
| 21 | Material & labour for taking out radiator of DG set 125 KVA to 320 KVA for repair, welding, brazing,leak testing, descaling & refixing to DG set to its original position and testing complete all as specified and directed by Engineer-in-Charge. |
| 22 | Taking out the charging alternator of DG Set of following capacity and shifting to workshop for rewinding of armature including replacement of rewinding unserviceable, bushes & minor parts & reinstalling the same after testing complete all as specified and directed by Engineer-in-Charge of following:-. |
| 23 | DG set of capacity upto 15 KVA |
| 24 | DG set of capacity 25 to 37.5 KVA |
| 25 | DG set of capacity 50 KVA |
| 26 | DG set of capacity 62.5/63 KVA |
| 27 | DG set of capacity 70 to 82.5 KVA |
| 28 | DG set of capacity 100 to 320 KVA |
| 29 | Supply & fix in replacement solenoid switch for 200 to 320 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
| 30 | Supply & fix in replacement solenoid switch for 160 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
| 31 | Supply & fix in replacement solenoid switch for 100 to 125 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
| 32 | Supply & fix in replacement solenoid switch for 70 to 82.5 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
| 33 | Supply & fix in replacement solenoid switch for 62.5/63 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
| 34 | Supply & fix in replacement solenoid switch for 7.5 to 50 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
| 35 | Supply & fix in replacement of AMF Relay suitable for DG sets complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply & fix in replacement of single phase preventor complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply & fix in replacement of PLA relay complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply & fix in replacement 3 pole power contactor with auxiliary 25 A,415 V complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply & fix in replacement 3 pole power contactor with auxiliary ,40/45 A,415 V complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply & fix in replacement 3 pole power contactor with auxiliary 75 A,415 V complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply & fix in replacement 3 pole power contactor with auxiliary 110/115 A,415 V complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply & fix in replacement 3 pole power contactor with auxiliary 185/225 A,415 V complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply & fix in replacement of HRC fuse base of capacity 125 to 400 Amps complete all as specified and directed by Engineer-in-Charge. |
| 44 | Removing, transporting to workshop, repairing & servicing of self starter of DG set ranging from 7.5 KVA to 320 KVA including replacement of parts such as washer, nut, bolts, bush, solonoid, rotor etc., reassembling and testing complete all as specified and directed by Engineer-in-Charge. |
| 45 | Descaling of water jacket of engine by using descaling solution with pressure circulation pump,leak testing, soldering, brazing, checking for leaks and recirculating with clear water complete all as specified and directed by Engineer-in-Charge for following DG sets:- |
| 46 | Up to 63 KVA DG Set |
| 47 | 70 KVA to 160 KVA DG Set |
| 48 | 200 KVA to 320 KVA DG Set |
| 49 | Supply & fix in replacement \\"V\\" belt for radiator fan complete all as specified and directed by Engineer-in-Charge for following DG Set:- |
| 50 | Upto 50 KVA |
| 51 | 62.5 to 82.5 KVA |
| 52 | 100 to 320 KVA |
| 53 | Replacement / filling up/ top up of engine oil (20 W 40) suitable for DG sets complete all as specified and directed by Engineer-in-Charge. |
| 54 | Replacement / filling up/ top up of pre mix coolant suitable for DG Set complete all as specified and directed by Engineer-in-Charge. |
| 55 | Material & labour for cleaning of diesel tank of DG Set \\"tank cleaned on Date to be writen ,complete all as specified and directed by Engineer-in-Charge. |
| 56 | Supply & fix in replacement of anti vibration pad suitable for 25 to 320 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply & fix in replacement of air cleaner filter for DG Set capacity 200 KVA to 320 KVA complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply & fix in replacement of air cleaner filter for DG Set capacity 70 KVA to 160 KVA complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply & fix in replacement of air cleaner filter for DG Set capacity 7 KVA to 63 KVA complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply & fix in replacement of hose pipe set suitable for following capacity of DG sets & complete all as specified and directed by Engineer-in-Charge for following. |
| 61 | Up to 63 KVA DG set |
| 62 | 70 KVA to 160 KVA DG set |
| 63 | 200KVA to 320 DG set |
| 64 | Supply & fix in replacement of AVR suitable for following capacity of DG Sets & complete all as specified and directed by Engineer-in-Charge for following. |
| 65 | Up to 50 KVA DG set |
| 66 | 62.5 to 125 KVA DG set |
| 67 | 160 to 320 KVA DG set |
| 68 | Supply & fix in replacement of battery lugs complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply & fix in replacement of ignition switch suitable for DG sets & complete all as specified and directed by Engineer-in-Charge. |
| 70 | Supply & fix in replacement of self starter suitable for up to 25 to 50 KVA DG Set 12 Volt complete all as specified and directed by Engineer-in-Charge. |
| 71 | Supply & fix in replacement of self starter suitable for 62.5 to 82.5 KVA DG Set 12 Volt complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply & fix in replacement of self starter suitable for 100 to 125 KVA DG Set 12 Volt complete all as specified and directed by Engineer-in-Charge. |
| 73 | Supply & fix in replacement of self starter suitable for 160 to 320 KVA DG Set 24 Volt complete all as specified and directed by Engineer-in-Charge. |
| 74 | Repair/replacement wiring upto 5mtr of DG Set/AMF panel 25 to 50 KVA complete all as specified and directed by Engineer-in-Charge. |
| 75 | Repair/Replacement wiring upto 5mtr of DG Set/AMF panel 62.5 to 100 KVA complete all as specified and directed by Engineer-in-Charge. |
| 76 | Repair/Replacement wiring upto 5mtr) of DG Set/AMF panel 125 to 320 KVA complete all as specified and directed by Engineer-in-Charge. |
| 77 | Supply & fix in replacement of of battery charger of 6 Amps for 12 Volt battery complete all as specified and directed by Engineer-in-Charge. |
| 78 | Supply & fix in replacement of battery charger of 6 Amps for 24 Volt battery complete all as specified and directed by Engineer-in-Charge. |
| 79 | Supply & fix in replacement of water pump complete for 35 to 320 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
| 80 | Supply & fix in replacement of diesel pipe filter to pump for DG set complete all as specified and directed by Engineer-in-Charge. |
| 81 | Supply & fix in replacement of diesel pipe filter to tank for DG set complete all as specified and directed by Engineer-in-Charge. |
| 82 | Supply & fix in replacement radiator up to 100 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
| 83 | Supply & fix in replacement radiator from125 to 200 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
| 84 | Supply & fix in replacement DG set/AMF Panel power controller up to 50 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
| 85 | Supply & fix in replacement DG set/AMF Panel power controller from 62.5 to 125 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
| 86 | Supply & fix in replacement DG set/AMF Panel power controller from 160 to 320 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
| 87 | Supply & fix in replacement MCCB's,415 Volts , 3 / 4 pole , with adjustable thermal & fixed magnetic settings having complete all as specified and directed by Engineer-in-Charge. for following capacities :- |
| 88 | 63 Amps 16 KA |
| 89 | 100 Amps 16 KA |
| 90 | 125 Amps 25 KA |
| 91 | 160 Amps 36 KA |
| 92 | 200 Amps 36 KA |
| 93 | 250 Amps 36 KA |
| 94 | 400 Amps 36 KA |
| 95 | Supply & fix Diesel pump with pipe assembly to make it fully fuctional and fixing it to its original position of DG set in any capacity including replacement necessary element complete all as specified and directed by Engineer-in-Charge. |
| 96 | Supply & fix Selector Switch 4/6 base complete all as specified and directed by Engineer-in-Charge. |
| 97 | Material & labour for complete checking of AMF panel,finding the fault,servicing complete including as per site and replacement of unserviceable spares and testing complete for manual & auto operations complete all as specified and directed by Engineer-in-Charge.(Note:- Supply only of new items required for replacement will be measured & paid seperately under respective item of schedule.) |
| 98 | Supply & fix distiled water suitable for battery of DG set complete all as specified and directed by Engineer-in-Charge. |
| 99 | Opening the coupling of DG set of capacity 200 to 320 KVA , dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified and directed by Engineer-in-Charge. |
| 100 | Opening the coupling of DG set of capacity 7.5 to 63 KVA, dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified and directed by Engineer-in-Charge. |
| 101 | Opening the coupling of DG set of capacity 70 KVA to 160 KVA, dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified and directed by Engineer-in-Charge. |
| 102 | Material & labour for calibration of fuel injector assembly of DG set of 70KVA to 160 KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc complete all as specified and directed by Engineer-in-Charge. |
| 103 | Material & labour for calibration of fuel injector assembly of DG Set of 7.5KVA to 63KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc complete all as specified and directed by Engineer-in-Charge. |
| 104 | Material & labour for calibration of fuel injector assembly of DG Set of 200KVA to 320 KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc complete all as specified and directed by Engineer-in-Charge. |
| 105 | Supply & fix in replacement of bentex wheel complete suitable for self starter complete all as specified and directed by Engineer-in-Charge. |
| 106 | Supply & fix in replacement of battery copper cable red with plug of size 35 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 107 | Supply & fix in replacement of battery copper cable black with plug of size 35 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 108 | Supply & fix in replacement fan assembly along with hub suitable for DG Set of any cap complete all as specified and directed by Engineer-in-Charge. |
| 109 | Supply & fixing in replacement three phase Volt Meter of size 96x96x80mm, flush mounting on panel 0 to 500 Volts, digital type, with built in selector switch complete all as specified and directed by Engineer-in-Charge. |
| 110 | Supply & fixing in replacement three phase Amps Meter of size 96x96x80mm, flush mounting on panel 0 to 200 Amps digital type, with built in selector switch complete all as specified and directed by Engineer-in-Charge. |
| 111 | Supply & fixing in replacement three phase AC multimeter of size 96x96x80mm, flush mounting on panel 0 to 500 Volts, 0 to 200 Amps and power digital type, with built in selector switch complete all as specified and directed by Engineer-in-Charge. |
| 112 | Taking out the alternator of DG set of capacity 7.5 KVA to 320 KVA and shifting to workshop for rewinding of armature including replacement of rewinding unserviceable, bushes & minor parts & reinstalling the same after testing complete all as specified and directed by Engineer-in-Charge. |
| 113 | Supply, install, testing and commissioning of AMF Panel OUTDOOR TYPE suitable for 35 KVA DG set factory made out of CRCA Steel 3.15mm thick Sheet, floor mounted type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints will be suitable gasketed to form dust and vermin proof. The panel should be powder coated with minimum thickness of 50 microns, after elaborate pre-treatment to form a long lasting characteristic. The control panel will be complete in all respect with fuses, wiring and labels etc, the following will be incorporated in the AMF Panel :-(i)Multifunctional meter digital (Amp+Volt+PF+Hz+KW+KWH)-01 No.(ii) Alternator voltage monitor 01 No(iii) Main voltage monitor - 01 No(iv) Ammeter DG digital - 01 No(v) Voltmeter DG digital - 01 No (vi) Main Power contactor -4 pole of capacity 63 Amps -01 No(vii) DG Power contactor -4 pole of capacity 63 Amps - 01 No(viii) Indicator Lamp - 02 Nos(ix) MCB (For control ckt)-10 Nos(x) Auxiliary Contactor -02 Nos (xi) Automatic battery charger 12 volt -01 No(xii) Terminal O/L relay - 01 No(xiii) Terminals (for control cable)-06 Nos(xiv) One set of copper bus bar of 200 Amps capacity. (xv) Main MCCB -4 pole of capacity 63 Amps -01 No(xvi) DG MCCB -4 pole of capacity 63 Amps - 01 No(xvii) control cable of suitable size -1 Job Note: The required PCC foundation for AMF Panel is included in the rate . |
| 114 | Complete overhauling of DG set of 7.5 KVA - 320 KVA capacity with dismantling of exhaust piping, fuel piping, HP pipes, inlet mainfold, hoses, Cy head, injectors and other related assessories and top overhauling CR bearing, con rod, piston, piston ring, cylinder liner and major overhauling charges watre pump, oil cooler HE, crank shaft, main bearing, thrust washer etc and reassembling with required torque tappet setting and trail and refixing of following items at original position etc complete all as specified and directed by Engineer-in-Charge. |
| 115 | Supply only cylinder liner complete all as specified and directed by Engineer-in-Charge. |
| 116 | Supply only piston complete all as specified and directed by Engineer-in-Charge. |
| 117 | Supply only piston ring complete all as specified and directed by Engineer-in-Charge. |
| 118 | Supply only inlet valve complete all as specified and directed by Engineer-in-Charge. |
| 119 | Supply only exhaust valve complete all as specified and directed by Engineer-in-Charge. |
| 120 | Supply only valve seat inlet complete all as specified and directed by Engineer-in-Charge. |
| 121 | Supply only valve seat exhaust complete all as specified and directed by Engineer-in-Charge. |
| 122 | Supply only valve guide complete all as specified and directed by Engineer-in-Charge. |
| 123 | Supply only HCT switch complete all as specified and directed by Engineer-in-Charge. |
| 124 | Supply only injector nozzle complete all as specified and directed by Engineer-in-Charge. |
| 125 | Supply only delivery valve complete all as specified and directed by Engineer-in-Charge. |
| 126 | Supply only pipe set complete all as specified and directed by Engineer-in-Charge. |
| 127 | Supply only connecting rod assly DL-6complete all as specified and directed by Engineer-in-Charge. |
| 128 | Supply only set gasket complete all as specified and directed by Engineer-in-Charge. |
| 129 | Supply only set of fuel flex complete all as specified and directed by Engineer-in-Charge. |
| 130 | Supply only con rod bush complete all as specified and directed by Engineer-in-Charge. |
| 131 | Supply only con rod bearing complete all as specified and directed by Engineer-in-Charge. |
| 132 | Supply only oil pressure guage complete all as specified and directed by Engineer-in-Charge. |
| 133 | Supply only water temp guage complete all as specified and directed by Engineer-in-Charge. |
| 134 | Supply only ammeter complete all as specified and directed by Engineer-in-Charge. |
| 135 | Supply only LLOP switch complete all as specified and directed by Engineer-in-Charge. |
| 136 | Supply only sealing ring complete all as specified and directed by Engineer-in-Charge. |
| 137 | Supply only AVM complete all as specified and directed by Engineer-in-Charge. |
| 138 | Supply only T/C KIT complete all as specified and directed by Engineer-in-Charge. |
| 139 | Supply only AVM for meter box complete all as specified and directed by Engineer-in-Charge. |
| 140 | Supply only set of O ring complete all as specified and directed by Engineer-in-Charge. |
| 141 | Supply only set of hose clip complete all as specified and directed by Engineer-in-Charge. |
| 142 | Supply only set of hoses complete all as specified and directed by Engineer-in-Charge. |
| 143 | Material & labour of diod to be fixed in alternator complete all as specified and directed by Engineer-in-Charge. |
| 144 | Supply & fixing in replacement digital timer for ON/OFF to the perimeter lights/DG Set complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |