| 1 | Supply Items : |
| 2 | Supply of L.T Aluminum armored XLPE single core cable size |
| 3 | 1X630 Sq mm. |
| 4 | 1X400 Sq mm. |
| 5 | Supply of Al Crimping lugs (630/400/120/70/35/25) Sq mm. for XLPE cable |
| 6 | Long Barrel Crimping Al. Lugs of Size -630 Sq.mm |
| 7 | Long Barrel Crimping Al. Lugs of Size -400Sq.mm |
| 8 | Long Barrel Crimping Al. Lugs of Size -240 Sq.mm |
| 9 | Long Barrel Crimping Al. Lugs of Size -185 Sq.mm |
| 10 | Long Barrel Crimping Al. Lugs of Size -120 Sq.mm |
| 11 | Long Barrel Crimping Al. Lugs of Size -70 Sq.mm |
| 12 | Long Barrel Crimping Al. Lugs of Size -50 Sq.mm |
| 13 | Supply of 1100 Grade. PVC sheathed steel strip armored, aluminum conductor LT XLPE insulated cable size |
| 14 | 3.5 CX240 Sq mm. XLPE |
| 15 | 3.5 CX120 Sq mm. XLPE |
| 16 | 3.5 CX70 Sq mm. XLPE |
| 17 | Supply of Cable end termination using total Double Compersation Brass Glands and Crimping type Aluminum thimbles size for L.T. cables. |
| 18 | 3.5 CX240 Sq mm. XLPE |
| 19 | 3.5 CX120 Sq mm. XLPE |
| 20 | 3.5 CX70 Sq mm. XLPE |
| 21 | Supply of HDPE pipe 110 mm dia to be laid by horizontal drilling for under ground piping (trenchless) at road cross of above cable. |
| 22 | Supply of LT Distribution Panels for the Replacement of Damage Panels |
| 23 | Supply of Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 1000 & 630 KVA (Type A-1) Incomer - 1 No. 1250 Amp. TP MDO ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer-1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 4 sets of 400 amp. TP MCCB with spreader & Extended handle) (2 sets of 250amp. TP MCCB with spreader & Extended handle) (2 sets of 100 0amp. TP MCCB with spreader & Extended handle) |
| 24 | Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubicle should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 400 KVA (Type A-2) (Incomer - 1 set of 800 amp. ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 6 sets of 250 amp. TP MCCB with spreader & Extended handle (5No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
| 25 | Supply of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 400 amp. Aluminum Bus bar (Type B-1) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) having : 1 no Incomer 250amp. TP MCCB and 6 No.out-going 100 amp. TP MCCB with spreader & Extended handle. |
| 26 | Supply of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 300 amp. Aluminum Bus bar (Type B-2) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) having : 1 no Incomer 250amp. TP MCCB and 5 No.out-going 100 amp. TP MCCB spreader & Extended handle. |
| 27 | Supply of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 300 amp. Aluminum Bus bar (Type B-3) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) having : 1 no Incomer 250 amp. TP MCCB and 4 No.out-going 100 amp. TP MCCB spreader & Extended handle. |
| 28 | Supply of GI Pipe 40mm dia B-Class 40 feet long for earthing of Type A and B panels |
| 29 | Supply of G.I . Pipe Chemical Earthing (electrode 3 mtr long 80 mm inner dia along with Chemical powder) |
| 30 | Supply of G.I.Strip of Size 50X6mm for connecting the Panels A& B type Panels. |
| 31 | Supply of LT Straight Through Jointing Kits |
| 32 | 3.5CX240sq.mm XLPE |
| 33 | 3.5CX120sq.mm XLPE |
| 34 | 3.5 CX70 Sq mm. XLPE |
| 35 | Supply of Off Size Nut & Bolts with washresg Duly Galvanised |
| 36 | 12X40mm |
| 37 | 16X35 mm |
| 38 | ERECTION PART |
| 39 | Laying, Testing & Commissioning of L.T Aluminum armored XLPE single core cable size |
| 40 | 1X630 Sq mm. |
| 41 | 1X400 Sq mm. |
| 42 | Erection of Al Crimping lugs (630/400/120/70/35/25) Sq mm. for XLPE cable |
| 43 | Long Barrel Crimping Al. Lugs of Size -630 Sq.mm |
| 44 | Long Barrel Crimping Al. Lugs of Size -400Sq.mm |
| 45 | Long Barrel Crimping Al. Lugs of Size -240 Sq.mm |
| 46 | Long Barrel Crimping Al. Lugs of Size -185 Sq.mm |
| 47 | Long Barrel Crimping Al. Lugs of Size -120 Sq.mm |
| 48 | Long Barrel Crimping Al. Lugs of Size -70 Sq.mm |
| 49 | Long Barrel Crimping Al. Lugs of Size -50 Sq.mm |
| 50 | Laying, testing and commissioning of 1100 volts grade, PVC sheathed steel strip armored aluminum conductor LT XLPE Insulated Cable of sizes 3.5 CX70/3.5 CX120/3.5 CX240 Sq mm. to be laid under ground in HDPE Pipes (As Above Clouman B-1,B-2,B-3 & B-4 mentioned cable are laid in this technology) |
| 51 | Digging of trench by Making pits after due survey with the help of utility detector ofexisting electrical/telephonic cable/and other utilites of public utilites department and laying of cables of size 3.5 CX70/3.5 CX120/3.5 CX240 Sq mm. XLPE by manual drill (by making moles) ( (As Above Clouman B-1,B-2,B-3 & B-4 mentioned cable are laid in this technology) |
| 52 | Laying of HDPE pipe for the protection of XLPES cable during the making of straight through jointing kit & Up to bottom of A& B Type Panel cable covering |
| 53 | Supply of Cable end termination using total double compersation Brass glands and crimping type aluminum thimbles size for L.T. cables. |
| 54 | 3.5 CX240 Sq mm. XLPE |
| 55 | 3.5 CX120 Sq mm. XLPE |
| 56 | 3.5 CX70 Sq mm. XLPE |
| 57 | Supply of HDPE pipe 110 mm dia to be laid by horizontal drilling for under ground piping (trenchless) at road cross of above cable. |
| 58 | Erection of L.T. Distribution Panels for the replacement of Damage Panels |
| 59 | Erection for the replacement of Damage of Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 1000 & 630 KVA (Type A-1) Incomer - 1 No. 1250 Amp. TP MDO ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 4 sets of 400 amp. TP MCCB with spreader & Extended handle) (2 sets of 250amp. TP MCCB with spreader & Extended handle) (2 sets of 100 0amp. TP MCCB with spreader & Extended handle) |
| 60 | Erection for the replacement of Damage of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubicle should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 400 KVA (Type A-2) (Incomer - 1 set of 800 amp.ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 6 sets of 250 amp. TP MCCB with spreader & Extended handle (5No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
| 61 | Erection for the replacement of Damage of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 400 amp. Aluminum Bus bar (Type B-1) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) having : 1 no Incomer 250amp. TP MCCB and 6 No.out-going 100 amp. TP MCCB with spreader & Extended handle. |
| 62 | Erection for the replacement of Damage of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 300 amp. Aluminum Bus bar (Type B-3) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) having : 1 no Incomer 250 amp. TP MCCB and 4 No.out-going 100 amp. TP MCCB spreader & Extended handle. |
| 63 | Dismantle & Making of Suitable Foundation as per Kesco Specification for the Installation of Type - A Panel and removal of Devris from the site including deposit of Damge panel from site to nerest Kesco Store (Associated to Sl No- 19.01- 19.02) |
| 64 | Dismantle & Making of Suitable Foundation for the Installation of Type - A Panel and removal of Devris from the site including deposit of Damge panel from site to nerestKesco Store (Associated to Sl No- 19.03-19.04) |
| 65 | Erection of GI Pipe 40mm dia B-Class 40 feet long for earthing of Type A and B panels |
| 66 | Erectionof G.I . Pipe Chemical Earthing (electrode 3 mtr long 80 mm inner dia along with Chemical powder) |
| 67 | Erection of G.I.Strip of Size 50X6mm for connecting the Panels A& B type Panels. |
| 68 | Erection of LT Straight Through Jointing Kits |
| 69 | 3.5CX240sq.mm XLPE |
| 70 | 3.5CX120sq.mm XLPE |
| 71 | 3.5 CX70 Sq mm. XLPE |
| 72 | Installation Off Size Nut & Bolts with washresg Duly Galvanised |
| 73 | 12X40mm |
| 74 | 16X35 mm Please Enable Macros to View BoQ information |