| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 2 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 3 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 4 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied at 0.90 litre/10 Sqm) |
| 5 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. |
| 6 | Lettering with black Japan paint of approved brand and manufacture. |
| 7 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalentdesign mix). |
| 8 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (including equivalent design mix). |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources :8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 10 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick |
| 11 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20 mm nominal size stone aggregate |
| 12 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 13 | Repairing , servicing & over hauling of rolling shutters of all sizes including greasing, oiling, tensioning of springs also replacing the damaged parts of rolling shutters like laths, shafts, pulleys, side guides, bottom plates welding of locking hooks, handles etc. complete (if required) so as to make its operation smooth through out the full contract period. Necessary required parts for rolling shutters shall be supplied free of cost by department. 1st quality Grease is to be arranged by the contractor. |
| 14 | Supply of springs of grade No. 2 of 27.5 cm length including loading, unloading and transportation at site and including all taxes etc. complete. |
| 15 | Supply of shafts of approved quality for rolling shutters of all sizes of 40 mm dia. MS pipe including loading, unloading and transportation and including all taxes etc. complete. |
| 16 | Supply of M.S. wheel of required size for rolling shutter of approved quality including loading, unloading and transportation at site and inclusive of alltaxes etc. complete. |
| 17 | Renewing glass panes ,with putty and nails wherever necessary including raking out the old putty.Float glass panes of nominal thickness 4 mm( weight not less than 10 kg / sqm) |
| 18 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 20 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 21 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. |
| 22 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 32 mm dia. |
| 23 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 24 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 25 | Repair and maintenance of GI/Profile roof of godown with material such as silicon sealant, self driilling/self tapping screws of size 5.5 x 55 mm with EPDM seal, including greasing of turbo ventilators as and when required during the contract period complete as per the directions of Engineer-in-charge. (Details of cost for 5000 MT capacity godown) |
| 26 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design , In 75x75 mm deep chase. |
| 27 | White washing with lime to give an even shade: Old work (two or more coats) |
| 28 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour One coat. |
| 29 | Dismantling roofing including ridges, hips, valleys and gutters etc and stacking the material within 50 mtr lead of G.S. Sheet/profile sheets. |
| 30 | Providing and fixing precoated galvanized iron profile sheets(size, shape and pitch of corrugation, as approved by Engineer -in - Charge) 0.50mm+0.05% total coated thickness(TCT) with Zinc Coating 120gsm as per IS:277 in 240 mpa steel grade, 5-7mm microns epoxy primer on both side of the sheet and polyster top coating 15-18 microns. Sheets should have protective guards film of 25 microns minimum to avoid scratches while transportation and should have supplied in single length upto 12 meter or as desired by Eng-in-Charge. The sheet shall be fixed using self-drilling /self -tapping screws of size(5.5x55mm) with EPDM seal complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 31 | Supply, Installation, Testing and commissioning of Turbo ventilators Size - 24\\" dia as per manufacturer specification with all accessories and as directed by Engineer -in charge . Size 24\\" -stainless steel grade - 430, No. of outer wings - 24 (24\\"), No. of inner wings - 6 (24\\"), Fan Base - Nylon, Top & Bottom - stainless steel grade - 430, inside material - Nylon, Fan Blade OD - 600 mm, Nylon blade ring - 560 mm (for 24\\"), Total fan height - 360 mm (for 24\\"), Self lubricating bearing. Base sheet should be made of Poly carbonite sheet of 2 mm thick. |
| 32 | Dismantling tile work in floor and roof laid in cement mortar including stacking of material with in 50 mtr lead Thickness of Tiles 10mm to 25mm. |
| 33 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 34 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm. |
| 35 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 36 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 37 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level,Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 38 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 39 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 40 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball, 20 mm nominal bore, 120 mm long, weighing not less 198 gms. |
| 41 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall: 15 mm dia nominal bore. |
| 42 | Providing and fixing soil, waste and vent pipes , 75mm dia Sand cast iron S&S pipe as per IS: 1729. |
| 43 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 44 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead ,Of area 3 sq. metres and below. |
| 45 | Providing and fixing to existing door frames.25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. |
| 46 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. omplete (Copper oxidised as per IS 1378) 200x10 mm |
| 47 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) : 125 mm |
| 48 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing,aneling and dash fasteners to be paid for separately) For fixed portion:Polyester powder coated aluminium. (minimum thickness of polyester powder coating 50 micron). |
| 49 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing,aneling and dash fasteners to be paid for separately)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 50 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm). |
| 51 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc as required , in grating, framed guard bar, ladder, railing, bracket gates and similar work. |
| 52 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately). |
| 53 | Credit for Taking away dismantled/released materialson\\"as is where is basis\\" as per directions of Engg-in-charge old scrap iron obtained from various items. |
| 54 | Providing and fixing false ceiling at all height with internal densified sodium silicate reinforced with fibre and natural fillars false ceiling tiles of 595x595mm of approved texture, design and patterns as per CPWD specifications 2019, to be laid to a true horizontal level suspended on interlocking metal T Grid of hot dipped galvanized iron section of 0.33 mm thick( galvanized @ 120gm/sqm on both sides) comprising of main Tee runners of size 24x 38mm of length 3000mm, cross Tee size 24x32mm length 1200mm and secondary intermediate cross Tee of size 24x32mm of length 600 mm to form grid module of size 600x600mm suspended from ceiling using galvanised mild steel items ( galvanising @ 80gms /per sqm) i.e 12x50mm long dash fastners 6mm dia fully threaded hanger rod upto 1000 mm length and L- shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6 mm with precut holes on both 25mm flange to pierce into 12x50mm or even bigger size dash fastners if require , fixed with galvanized iron perimetre wall angle or size 24x24x0.40mm of length 3000mm to be fixed on periphey wall/partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall SS screw. The work shall be carried out as per specifications drawings and as per directions of Eng-in-Charge, With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles |
| 55 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. |
| 56 | Painting motif and grafitti on the Gable walls of godown with premium acrylic Smooth exterior paint with silicone additives of required shade: New Work(two or more coat) Please Enable Macros to View BoQ information |