| 1 | Operation & maintenance of clear water booster pump sets, submersible pump set EI & Fans of staff qtrs. And street light at following locations as per inventory terms & conditions attached.a) Old Rajender Nagar.b) Bagh Raoji,c) Dev Nagar,d) CC hosue Karol Baghe) Community Hall old Rajender Nagar. |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface / recessed steel/PVC conduit including dismantling as required. -Group A. (DSR No. 1.15.1) |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 4 | 3 x 4 sq. mm |
| 5 | 3 x 6 sq. mm |
| 6 | Dismentling, rewinding / repairing, greasing of following type ceiling fan / exhaust fan i/c re-installation connection testing etc. complete as reqd. |
| 7 | 48” ceiling fan |
| 8 | 300mm sweep exhaust fan |
| 9 | Supplying & Replacement(from deputed labour) of following items ( ISI marked) including connection, testing complete as required. |
| 10 | 5/6 Amp. Piano type switch |
| 11 | 15/16Amp. Piano type switch |
| 12 | 5/6 Amp. 3 pin socket outlet(Piano type) |
| 13 | 15/16 Amp. 6 pin socket outlet (Piano type) |
| 14 | 6 Amp. Bell push piano type |
| 15 | Call bell/Buzzer |
| 16 | Stepped stype modular fan regulator |
| 17 | PVC batten/Angle holder |
| 18 | 6-32 Amp. SP MCB 'C' curve 10 KA breaking capacity |
| 19 | 6-32 Amp. SP&N MCB (C- curve 10 KA breaking capacity) |
| 20 | 2.5mfd capacitor |
| 21 | 3.15mfd capacitor |
| 22 | 63 Amp. 2 pole isolator |
| 23 | 3 mm thick phenolic laminated sheet |
| 24 | Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. a) Installation, Testing and Commissioning to be done by electrician/wireman |
| 25 | Supplying, installation testing, commissioning of 300mm sweep exhaust fan, silver in colour having 3 no. of blade i/c condenser, etc. complete as required. |
| 26 | Supplying & replacement of T5 Tube with 20 watt LED Batten from deputed labour i/c connection, testing etc. complete as required. |
| 27 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) 63 A - (DSR No. 2.13.2) |
| 28 | Dismantling, rewinding and re-assembling of 5 HP 3 Phase 415 volt induction motor, replacement of connection plate i/c varnishing, tapping connection, testing cartage to and fro etc. complete as required. |
| 29 | Repairing of 5 HP centrifugal Pump set i/c S/R of following worn out parts i.e. gland sleeve, neck ring, ball bearing, nut bolt, poacing and cartage to & fro i/c dismantling & reassembling, commissioning at site etc. as required. |
| 30 | Rewinding & Repairing of 3 HP submersible mono block pump set i/c dismantling & reassembling, commissioning at site etc. as required. |
| 31 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required |
| 32 | 65mm dia |
| 33 | Servicing of following type Air Conditioning unit of 1.5/2 TR capacity i/c cleaning condenser and evaporation coil etc with chemical lubricating after washing air conditioning units alongwith front grill, oiling fan motor, reinstallation of air conditioner in the original location, testing etc. complete as required. |
| 34 | Supplying and charging of refrigerant gas in 1.5 Ton/2.0 TR capacity following type air conditioning units of different make i/c carrying out pressure test and cooling effect etc. complete as required. |
| 35 | Supply of 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable. |
| 36 | Supplying and fixing of 25 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 37 | Supplying, Installation, Testing & Commissioning of 45 watt Street light LED fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt) with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage rotection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 38 | Supply of LED Wall Light, 6 Watt, Outdoor Type, IP-65 Protected, Exterior Wall Washer Lamp complete with inbuilt LED and all accessories as required. |
| 39 | Supply of In-Ground LED Light Fixture, Warm White, IP-67 Waterproof, suitable for outdoor ground burial application, with 2 KV surge protection, complete with LED, driver and all accessories as required. |
| 40 | Supply, installation, testing & commissioning of Philips LED Garden Spike Light, 12 Watt, Warm White, IP65 water resistant, with COB integrated technology, adjustable spike mounting suitable for outdoor garden decoration/landscape lighting, complete with all accessories as required. Please Enable Macros to View BoQ information |