| 1 | Excavating over areas, not exceeding 1.5 m deep and getting out in soft/loose soil,comeplete all as specified and directed. |
| 2 | Excavating over areas, exceeding 1.5 mtr but but not exceeding 3.00 mtr deep and getting out in soft/loose soil,comeplete all as specified and directed. |
| 3 | Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed. |
| 4 | Excavation in trenches in any type of soil exceeding 1.5 metre but not exceeding 3.0 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc.complete all as specified and directed. |
| 5 | Formwork to rough finished surfaces of walls,retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter of rough finished surface of concrete of curved surface .complete all as specified and directed. |
| 6 | M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in as in walls, retaining walls, basement walls, ballast walls and the like, any footing ,including attached pilasters and buttressed etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 7 | M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in coloumns, pillars, piers,post and struts etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 8 | M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in foundation including including rafts,footing,foundation beams; plinths beams; rafts for columns, etc.; basement slabs, under-reamed piles and mass concrete etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 9 | Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed. |
| 10 | Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions of rough finished surface of concrete surfaces square, rectangular or polygonal for rough finished surface of concrete complete all as specified and directed. |
| 11 | M&L for 15mm thick rendering on stone masonry surfaces or on fair face of brick work or concrete surface in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed , Note:(i) Two coat of acrylic cementitious water proofing coating ( Dr FIXIT Pidifin 2K manufactured by M.s Pidilite Industries Ltd or equivalent) and followed by an overlayed protective screed plaster along with liquid water proofing compound approved make as per manufacturer's instructions on plastered surfaces of basement slab/wall to achieved as per manufacturers instruction complete all as specified and directed.(ii) Rate quoted by bidder deemed to be inclusive of WPC & Dr FIXIT Pidifin 2K manafactured by M/s Pidilite Industries. |
| 12 | M&L for preparation of newely plastered surfaces of wall and applying three coats of white wash on wall surface complete all as specified & directed. |
| 13 | M&L for hard core of broken stone or boulder gauge not exceeding 63mm deposited, spread & leveled in layers not exceeding 15cm thick, watered and rammed to a true surface etc complete all as specified& directed. |
| 14 | .M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed. Note:- Plinth Protection shall be laid to slope 1:30 in alternative bays. |
| 15 | M&L for mild steel TMT steel bars 10mm dia and over grade Fe-500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. |
| 16 | M&L for mild steel TMT bars 08 mm dia and over grade Fe -500 , as in stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for coloumn,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. |
| 17 | Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge. |
| 18 | Removal of surplus excavated soil to a distance exceeding 50 Mtr and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified. |
| 19 | S&F for framed bracket of angle or tee or flat iron etc as per drawing including cutting, bending, welding, drilling, countersunk, cleat or other connecting plates,cutting, each bracket including nut, bolts ad screws etc complete all as specified including supports or stays for fixing gutter or PVC pipe including painting two coats of aluminium paint over a coat of primer ( Code E-165) quality A1 as specified and directed. |
| 20 | M& L for forming construction (Dummy) joint 30mm deep x 10mm wide filled with & including sealing compound grade A as complete all as specified and directed. |
| 21 | M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ of thickness of slab complete all as specified and directed. |
| 22 | M&L for 10cm thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, not exceeding. 2 m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4, complete all as specified and as directed. |
| 23 | S&F of 0.63mm thick plain, galvanised, mild steel sheeting, in ridges,hips, valley gutters, drip and straight flashings and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc, complete all as specified and directed, |
| 24 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 25 | S&F 110mm dia PVC (SWR) bends complete all as specified and directed. |
| 26 | M&L for fly ash brick work using old size bricks (size 15-12894-2002), straight or curved on plan exceeding 6.0 m mean radius, built in cement mortar 1:4 etc complete all as specified & directed. |
| 27 | M&L for 15mm thick rendering (external) on stone masonry surfaces or on other than fair face of brick work or concrete surface in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed |
| 28 | M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including use and waste of necessary formwork complete all as specified and directed. |
| 29 | Excavation in post holes (or similar holes) each not exceeding .0.5 cum, getting out, not. exceeding. 25 cm, removing surplus soil to a distance not exceeding 50m and making good surface for hard / dense soil etc, complete all as specified and directed. |
| 30 | S&F for rolled sections such as main and cross beams, hip and jack rafters, purlins where connected to hip and jack rafters, including cleats or other connecting plates and cutting, drilling holes for bolts and including welding, conforming to grade Fe 410-W Grade E-250 quality etc complete all as specified and directed |
| 31 | Use & waste form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed. |
| 32 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa & minimum AZ @150 gm/Sqm( be coated with hot dip alloy of 55 % aluminium, 43.5% Zinc, 1.5% Silicon and finished with resin coat on both surface @ 150 gm/Sqm of coating both surfaces) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed. |
| 33 | M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified & directed. |
| 34 | S&F for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick walls (concealed) and making good the surface in cement mortar 1:3 complete all as specified & directed. |
| 35 | S&F for GI water tubing medium grade, ISI marked, galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick walls (concealed) and making good the surface in cement mortar 1:3 complete all as specified & directed. |
| 36 | S & F 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. Please Enable Macros to View BoQ information |