| 1 | Taking up U/S CI /DI/AC water main (incl all fitting) with spigot & socket /MS pipe or any other type of pipe or lead joint incl burning out joint & recovering lead from pipe of 400 mm bore for laying /rerouting of serviceable pipe after cleaning complete all as specified and as directed. |
| 2 | All as per item 1 above but 250 mm dia bore complete all as specified and as directed. |
| 3 | All as per item 1 above but 200 mm dia bore complete all as specified and as directed. |
| 4 | All as per item 1 above but 150 mm dia bore complete all as specified and as directed. |
| 5 | All as per item 1 above but 100 mm dia bore complete all as specified and as directed. |
| 6 | Material and labour DI pipes of size 400 mm bore with spigot and socket end centrifugally cast class \\"K- 9\\" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and as directed. |
| 7 | All as per item 6 above but 250 mm dia bore complete all as specified and as directed. |
| 8 | All as per item 6 above but 200 mm dia bore complete all as specified and as directed. |
| 9 | All as per item 6 above but 150 mm dia bore complete all as specified and as directed. |
| 10 | All as per item 6 above but 100 mm dia bore complete all as specified and as directed. |
| 11 | Material and labour DI pipes of size 200 mm bore with spigot and socket end centrifugally cast class \\"K- 7\\" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and as directed. |
| 12 | All as per item 11 above but 150 mm dia bore complete all as specified and as directed. |
| 13 | All as per item 11 above but 100 mm dia bore complete all as specified and as directed. |
| 14 | M&L DI bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y juction double branch cross(all socket and spiogat collars caps and plug for the pipe socket & spiogat of the following size 250 upto 400 mm dia complete all as specified and as directed. |
| 15 | All as per item 13 above but Upto 80 to 200 mm bore complete all as specified and as directed. |
| 16 | M&L for run laid laid joint for CI pipe of size 100 mm bore complete all as specified and as directed. |
| 17 | M&L for run laid laid joint for CI pipe of size 150/200 mm bore complete all as specified and as directed. |
| 18 | M&L for ruber gas ket joint/ tyton joint for CI / DI pipe of size 250 to 400 mm bore complete all as specified and as directed. |
| 19 | M&L for ruber gas ket joint/ tyton joint for CI / DI pipe of size 80 to 200 mm bore complete all as specified and as directed. |
| 20 | Taking down carefully cast iron sluice valve of size 250 mm bore from CI water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed. |
| 21 | Taking down carefully cast iron sluice valve of size 200 mm bore from CI water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed. |
| 22 | Taking down carefully cast iron sluice valve of size 150 mm bore from CI water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed. |
| 23 | Taking down carefully cast iron sluice valve of size 100 mm bore from CI water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed. |
| 24 | Taking down carefully cast iron sluice valve of size 80 mm bore from CI water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed. |
| 25 | Taking out existing U/S CI sluice valve of any size any pattern up to 250 mm bore from 80 mm bore complete all as specified and as directed. |
| 26 | S&F Cast iron gate sluice valve of size 80 mm dia Stainless steel stem PN- 1.6 ( Flanged) conforming to IS 14846 hand wheel operated complete all as specified and as directed. |
| 27 | All as per Item No 26 Above but 100 mm dia complete all as specified and as directed. |
| 28 | All as per Item No 26 Above but 150 mm dia complete all as specified and as directed. |
| 29 | All as per Item No 26 Above but 200 mm dia complete all as specified and as directed. |
| 30 | All as per Item No 26 Above but 250 mm dia complete all as specified and as directed. |
| 31 | Disconnecting and taking down old existing PVC tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including all fittings/accessories and fixtures such as bends, union, elbow socket, valves, taps etc, all as directed and specified for 20 mm dia pipe complete all as specified and directed. |
| 32 | All as per item No. 31 here in above but 25 mm dia complete all as specified and as directed. |
| 33 | All as per item No. 31 here in above but 40 mm dia complete all as specified and as directed. |
| 34 | All as per item No. 31 here in above but 50 mm dia complete all as specified and as directed. |
| 35 | All as per item No. 31 here in above but 80 mm diacomplete all as specified and as directed. |
| 36 | All as per item No. 31 here in above but 100 mm dia complete all as specified and as directed. |
| 37 | Supply and Fixing in any length UPVC pipe 20 mm dia pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed |
| 38 | All as per item No. 37 here in above but size (25 mm dia) complete all as specified and as directed. |
| 39 | All as per item No. 37 here in above but size (40 mm dia) complete all as specified and as directed. |
| 40 | All as per item No. 37 here in above but size (50 mm dia) complete all as specified and as directed. |
| 41 | All as per item No. 37 here in above but size (80 mm dia) complete all as specified and as directed. |
| 42 | All as per item No. 37 here in above but size (100 mm dia) complete all as specified and as directed. |
| 43 | S & F in repair UPVC Ball valves with operating handle (stop valve) of size 20 mm dia complete suitable for fittings with ASTM - 1785, Schedule 40 UPVC pipes complete all as specified and as directed. |
| 44 | All as per item No. 43 here in above but of size (25 mm dia) complete all as specified and as directed. |
| 45 | All as per item No. 43 here in above but of size (50 mm dia) complete all as specified and as directed. |
| 46 | All as per item No. 43 here in above but of size (80 mm dia) complete all as specified and as directed. |
| 47 | S&F ball valve gun metal valve with iron handle screwed both ends for iron pipe and fixed of size bore of pipe 40 mm complete all as specified and as directed. |
| 48 | All as per Item No 47 Above but Bore of pipe 50 mm complete all as specified and as directed. |
| 49 | Taking out existing U/S NRV of size upto 200 mm bore complete all as directed. |
| 50 | Suply and fixing cast iron NRV flanged end of size 200 mm dia with all fitting and accessories complete all as specified and as directed. |
| 51 | All as per item 50 above but 150 mm dia complete all as specified and as directed. |
| 52 | All as per item 50 above but 100 mm dia complete all as specified and as directed. |
| 53 | All as per item 50 above but 80 mm dia complete all as specified and as directed. |
| 54 | M & L for repairing and attending complaint for per day of no water supply etc in MD/OTM buildings at AOR of GE (A) Bhuj, arrangement of all T&P and ledder for climbing to roof of Bldgs and excavation & earth work if any and including all minor parts such as elbow,tee,socket,union,solution , D/mechnical joint etc upto 80 mm GI/Upvc pipe complete including threading/cutting of pipe as required at site complete all as specified and as directed. |
| 55 | Supply only UPVC pipe fittings any type & size upto 50 mm bore including all connected accessories to fix in pipe line complete all as specified and as directed. |
| 56 | Supply only UPVC pipe fittings any type & size above 50 and upto 100 mm bore including all connected accessories to fix in pipe line complete all as specified and as directed. |
| 57 | Supply only mechanical joint ( Badiya) for any type & size of pipe including all connected accessories to fix in pipe line complete all as specified and as directed. |
| 58 | Supply only D joint CI comlete with all accessories suitable for 400 mm bore any pipe line complete all as specified and as directed. |
| 59 | Supply only D joint CI comlete with all accessories suitable for 250 mm bore any pipe line complete all as specified and as directed. |
| 60 | Supply only D joint CI comlete with all accessories suitable for 200 mm bore any pipe line complete all as specified and as directed. |
| 61 | Supply only D joint CI comlete with all accessories suitable for 150 mm bore any pipe line complete all as specified and as directed. |
| 62 | Supply only D joint CI joint comlete with all accessories suitable for 100 mm bore any pipe line complete all as specified and as directed. |
| 63 | Supply only D joint CI joint comlete with all accessories suitable for 80 mm bore any pipe line complete all as specified and as directed. |
| 64 | Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed. |
| 65 | Rentring filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed. |
| 66 | Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed. |
| 67 | Hard standing cutting/road cutting for laying of pipe and making surface good with PCC 1:3:6 complete all as specified and directed. |
| 68 | Taking out existing U/S foot valve of size 50-150 mm bore complete all as specified and as directed. |
| 69 | Suply and fixing cast iron foot valve ball type flanged end of size 150 mm dia with all fitting and accessories complete all as specified and as directed. |
| 70 | Suply and fixing cast iron foot valve ball type flanged end of size 100 mm dia with all fitting and accessories complete all as specified and as directed. |
| 71 | Suply and fixing cast iron foot valve flanged end of size 80 mm dia with all fitting and accessories complete all as specified and as directed. |
| 72 | Suply and fixing cast iron foot valve flanged end of size 50 mm dia with all fitting and accessories complete all as specified and as directed. |
| 73 | S&F in replacement end Cap Plug of size up tp 50 mm complete all as specified and as directed. |
| 74 | Testing of Raw /clear Water for bacteriological analysis, Chemical analysis, as per stareded/IS code test from any Govt. Approved/recognized Lab or NABL approved Lab or as approved by the GE. Sample should be collected by Ref of lab. |
| 75 | M&L for painting of Valve Chambar palastered portion with cement base and steel portion with synthetic enamel paint of any size complete all as specified and as directed. |
| 76 | Supply & demonstration of chlorine residual test kit portable manually operated range 0.1 - 1 PPM and 0.6 to 6 PPM with enclosure & orthodin solution bottle 500 ml cap complete all as specified and as directed. |
| 77 | M & L for gland filling of Sluice Valves/Pumps including Nuts & Bolts as per existing size and nos complete all as specified and as directed. |
| 78 | S&F in repair new Leather Sheet flap with Cast iron plate of foot valve upto 100 mm dia with necessary fixing arrangement like nut , bolts washer packing sheet etc including taking out existing defective foot valve from UG sump complete all as specified and as directed. |
| 79 | S&F in repair new Leather Sheet flap with Cast iron plate of foot valve of size 150 mm dia with necessary fixing arrangement like nut , bolts washer packing sheet etc including taking out existing defective foot valve from UG sump complete all as directed at site. |
| 80 | Supply and Fixing in replacement of Key for operating of sluvice valave of size upto 250 mm complete all as specified and as directed. |
| 81 | S&F tank nipple suitable for HDPE water tank of size 20 mm complete all as specified and as directed. |
| 82 | S&F tank nipple suitable for HDPE water tank of size 25 mm complete all as specified and as directed. |
| 83 | Disconnecting and Taking up U/S CI /DI/PP-R / Unplasticiscd PVC pipes of pressure rating 10 kgf/cm2 laid in trenches from pipe of 20 mm bore for laying /rerouting of serviceable pipe after cleaning complete all as specified and as directed. |
| 84 | All as per item 83 above but 25 mm dia bore complete all as specified and as directed. |
| 85 | All as per item 83 above but 40 mm dia bore complete all as specified and as directed. |
| 86 | All as per item 83 above but 50 mm dia bore complete all as specified and as directed. |
| 87 | All as per item 83 above but 80 mm dia bore complete all as specified and as directed. |
| 88 | All as per item 83 above but 100 mm dia bore complete all as specified and as directed. |
| 89 | All as per item 83 above but 150 mm dia bore complete all as specified and as directed. |
| 90 | Supply and Fixing in any length UPVC pipe 20 mm dia pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed |
| 91 | All as per item No. 84 here in above but size (25 mm dia) complete all as specified and as directed. |
| 92 | All as per item No. 84 here in above but size (40 mm dia) complete all as specified and as directed. |
| 93 | All as per item No. 84 here in above but size (50 mm dia) complete all as specified and as directed. |
| 94 | All as per item No. 84 here in above but size (80 mm dia) complete all as specified and as directed. |
| 95 | Supply and Fixing in any length 3- layer 20 mm dia PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches required length complete all as specified and directed |
| 96 | All as per item No. 85 here in above but size (25 mm dia) complete all as specified and as directed. |
| 97 | Supply, laying, connecting, jointing and testing ductile iron pressure pipe of size 100 mm(4\\") inch dia , ISI marked suitable for \\"push on joints\\" in standard working lengths supplied with rubber gasket duly ISI marked for water supply, Class K-7 with socket and with cement mortar lining inside the metalic zinc coating with finishing layer of bituminious paint on outside the pipe complete all as specified & directed. |
| 98 | Supply, laying, connecting, jointing and testing ductile iron pressure pipe of size 150 mm(6\\") inch dia , ISI marked suitable for \\"push on joints\\" in standard working lengths supplied with rubber gasket duly ISI marked for water supply, Class K-7 with socket and with cement mortar lining inside the metalic zinc coating with finishing layer of bituminious paint on outside the pipe complete all as specified & directed. |
| 99 | Supplying fixing and testing of DI pipe fittings (Specials) heavy duty for any type ( flanged/socketed) pipes such as, bends (any type radius, and angle), tapers, any type straight bend, increasing, decreasing, or double socket etc) Tee pieces, ring branch, Y junction, double branch, Cross (all socket or socket and spigot), collors, caps and plugs, adopters etc of any size radius and length confirming to IS specifications up to 250 mm bore complete all as specified and directed. |
| 100 | Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc complete all as specified and as directed. (Note : outer dia of pipe 16 mm to 50 mm) |
| 101 | Taking out existing U/S PPR/ UPVC Ball valves valve of size 20-80 mm bore complete all as specified and as directed. |
| 102 | S & F in repair UPVC Ball valves with operating handle (stop valve) of size 20 mm dia complete suitable for fittings with ASTM - 1785, Schedule 40 UPVC pipes complete all as specified and as directed. |
| 103 | All as per item No. 91 here in above but of size 25 mm dia complete all as specified and directed. |
| 104 | All as per item No. 91 here in above but of size 40 mm dia complete all as specified and directed. |
| 105 | All as per item No. 91 here in above but of size 50 mm dia complete all as specified and directed. |
| 106 | All as per item No. 91 here in above but of size 80 mm dia complete all as specified and directed. |
| 107 | S & F in repair PP-R Ball valves (brass insert) as per requirement of the site PP-R Ball valves with operating handle (stop valve) of size 20 mm dia complete suitable for fittings with ASTM - complete all as specified and as directed. (Note : include UV stabilized and antimicrobial fusion welded) |
| 108 | All as per item No 92 here in above but of size 25 mm dia complete all as specified and directed. |
| 109 | Taking out existing U/S foot valve of size 50-100 mm bore complete all as specified and as directed. |
| 110 | Suply and fixing cast iron foot valve flanged end of size 100 mm dia with all fitting and accessories complete all as specified and as directed. . Make- Kirloskar/zoloto /Kartar |
| 111 | Suply and fixing cast iron foot valve flanged end of size 80 mm dia with all fitting and accessories complete all as specified and as directed. Make- Kirloskar/zoloto /Kartar |
| 112 | Supply and fixing D joint CI complete with all accessories suitable for 150 mm bore any pipe line complete all as specified and directed. |
| 113 | Supply and fixing D joint CI complete with all accessories suitable for 100 mm bore any pipe line complete all as specified and directed. |
| 114 | Supply and fixing D joint CI complete with all accessories suitable for 80 mm bore any pipe line complete all as specified and directed. |
| 115 | Taking out existing U/S CI sluice valve of any size any pattern up to 200 mm bore complete all as specified and directed. |
| 116 | S&F Cast iron sluice valve of size 80 mm dia Stainless steel stem PN- 1.6 ( Flanged) conforming to IS 14846 hand wheel operated complete all as specified and directed. |
| 117 | All as per Item No 101 above but 100 mm dia complete all as specified and directed. |
| 118 | All as per Item No 101 above but 150 mm dia complete all as specified and directed. |
| 119 | Taking out the broken, rusted, valve pit cover of any size and M & L for fixing valve pit cover of suitable size to existing made of 3mm thick MS sheet/plate including provision of hinges, handle and locking arrangement including 40 x40 x 4mm iron frame fixed or top of valve pit , including two coat of anti-corrosive paint over a coat of red oxide primer and necessary brick and cement work complete all as specified and as directed. |
| 120 | M&L for Construction of block masonery valve pit chamber of size 900 x 900 x 900 MM (internal dimension) (above GL 0.30 mtr) suitable for fixing of sluice valves, 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 10mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 10mm thick, finished even and smooth, without using extra cement, 5 mm thick plate cover on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified and directed. |
| 121 | M & L for Hard standing cutting/road cutting for laying of pipe and making surface good with PCC 1:3:6 complete all as specified and directed. |
| 122 | Supply, Installation, commissioning and testing Submersible pump set in replacement of cap 15 HP (Pump & Motor) comprising of bronze impellers directly coupled with motor cast iron body electric driven 415V, TP suitable for 300 mm dia borewell multi-stages, discharge of 500 LPM at 40 metre head and complete with suitable end connecting tail piece ,NRV and submersible cable minimum 7.5 RM complete all as specified and directed. (New Pump house) |
| 123 | Supply and Fix in replacement of Automatic Star Delta starter for 20 HP motor which includes 2 contactors of 20A ,1- contactor of No of 12A ,1-No of Thermal over load relay of capacity 45 to 75A ,1-No of Timer ,1-N0's of Volatge sensing relay,control wiring ,MCB,push buttons,Indicating lamps,15 KVAR Capacitor bank and other necessary control wiring including mounted of existing place with necessary civil work, nuts, bolts & washer etc complete all as specified and directed. (Note : New Pump house ) |
| 124 | S & F of 15 KVAR Capacitor bank ,Voltage rating 415V or 440V ,Cylindrical or Box type complete all as specified and directed. Make :L&T,Scneider electric ) Location : Rambag Water Point |
| 125 | Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed. |
| 126 | Returning, filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed. |
| 127 | Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting pointall complete all as specified and directed. |
| 128 | Supply, install, commissiong in repair Ultrasonic Flowmeter of dia 200 mm, 4 - 20 mA DC, Line Size : DN80 Pressure Rating : 10 kg/cm2 Design of measuring sensor : Flange ANSI 80 Flange Material : Carbon Steel Sensor Lining : Hard Rubber ,Electrode Material : SS 316L Earthing Rings : SS 316,Measuring Tube : SS 304 Coil Housing : Carbon Steel ,Protection Class : IP 65 complete all as specified and as directed. |
| 129 | Supply, install, commissiong in repair Ultrasonic Flowmeter of dia 80 mm, 4 - 20 mA DC, Line Size : DN80 Pressure Rating : 10 kg/cm2 Design of measuring sensor : Flange ANSI 80 Flange Material : Carbon Steel Sensor Lining : Hard Rubber ,Electrode Material : SS 316L Earthing Rings : SS 316,Measuring Tube : SS 304 Coil Housing : Carbon Steel ,Protection Class : IP 65 complete.(Location ; Khari Rohar) |
| 130 | S&F polypropelene rope 32 mm dia, confirming to IS standard, heavy duty grade for securing the submersible pump set alongwith column pipes of borewells complete all as specified and as directed. Make : GARWARE or equivalent |
| 131 | Testing of Raw Water for physical, bacteriological analysis, Chemical analysis, Toxic substance present ,virological , iron salinity as per stareded/IS code test from any Govt. Approved/recognized Lab or NABL approved Lab or as approved by the GE. Sample should be collected by Ref of lab. |
| 132 | M & L for repairing and attending complaint for per day of no water supply etc in MD/OTM buildings at AOR of Gandhidham Stn, arrangement of all T&P and ledder for climbing to roof of Bldgs and 1 cum of excavation & earth work if any and including all minor parts such as elbow,tee,socket,union,solution , D/mechnical joint etc upto 80 mm GI/Upvc pipe complete including threading/cutting of UPVC /GI pipe as required at site complete all as specified and directed (Note: Docket provide by contractor). Please Enable Macros to View BoQ information |
| 133 | M & L for repairing and attending complaint for per day of no water supply etc in MD/OTM buildings at AOR of Gandhidham Stn, arrangement of all T&P and ledder for climbing to roof of Bldgs and 1 cum of excavation & earth work if any and including all minor parts such as elbow,tee,socket,union,solution , D/mechnical joint etc upto 80 mm GI/Upvc pipe complete including threading/cutting of UPVC /GI pipe as required at site complete all as specified and directed (Note: Docket provide by contractor). Please Enable Macros to View BoQ information |