| 1 | M&L for disconnecting, cutting and taking out unserviceable sealed unit AC compressor 1.5 Tonne capacity inverter/ non inverter, single phase, 230 Volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure testing, leakage, rectification and supply and fixing of new compressor of same capacity and make including gas charging R-22/ R32/ R-410c and testing complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for disconnecting, cutting and taking out unserviceable sealed unit AC compressor 2.0 Tonne capacity, single phase, 230 Volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage, rectification and supply and fixing of new compressor of same capacity and make including gas charging R-22/ R32/ R-410c and testing complete all as specified and directed by Engineer-in-Charge. |
| 3 | M&L for WATER JET servicing of SPLIT TYPE AC's of 1.5/ 2.0 Tonne capacity (complete indoor and outdoor unit by using service bag cover and cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil, condenser coil and other components using clean water greasing of fan, motor, blower etc. without damage any part and re-install at the same location complete all as specified and directed by Engineer-in-Charge.Note:- Contractor has to provide blower and jet pump for cleaning and washing of AC, a separate PVC bag will also be provided for collection of waste, mechanic will be responsible to clean the site after servicing. Contractor shall at his own cost arrange water for servicing purpose. |
| 4 | M&L for WATER JET servicing of WINDOW TYPE AC's of 1.5/ 2.0 Tonne capacity (complete unit by using service bag cover and cooling coil rinse solution for cleaning of coils), taking out the indoor and outdoor cover from existing location, cleaning of cooling coil, condenser coil and other components using clean water greasing of fan, motor, blower etc. without damage any part and re-install at the same location complete all as specified and directed by Engineer-in-Charge.Note:- Contractor has to provide blower and jet pump for cleaning and washing of AC, a separate PVC bag will also be provided for collection of waste, mechanic will be responsible to clean the site after servicing. Contractor shall at his own cost arrange water for servicing purpose. |
| 5 | S&F in repairs air conditioner running capacitor of capacity 2.5 MFD, 230 Volts, 50 HZ, suitable for indoor unit complete all as specified and directed by Engineer-in-Charge. |
| 6 | S&F in repairs air conditioner running capacitor of capacity 4 MFD, 230 Volts, 50 Hz, suitable for indoor unit complete all as specified and directed by Engineer-in-Charge. |
| 7 | S&F in repairs air conditioner running capacitor of capacity 6 MFD, 230 Volts, 50 Hz, complete all as specified and directed by Engineer-in-Charge. |
| 8 | S&F in repairs air conditioner running capacitor of capacity 45 MFD, 230 Volts, 50 Hz, complete all as specified and directed by Engineer-in-Charge. |
| 9 | S&F in repairs air conditioner running capacitor of capacity 50 MFD, 230 Volts, 50 Hz, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Takigng down existing condensing fan motor from the unit and M&L for rewinding of condensing fan motor of capacity 1.5/ 2.0 Tonne (split type/ window type) of any make with super enameled copper wire winding wire including replacement of the motor bushes and shaft and testing on load for the entire satisfaction of Engineer-in-Charge. |
| 11 | Takigng down existing fan blower motor of cooling unit and M&L for rewinding of fan blower motor of cooling unit of capacity 1.5/ 2.0 ton (split type/ window type) unit with supper enameled copper winding wire of suitable gauge wire including replacement of the shaft and bushes and testing on load for the entire satisfaction of Engineer-in-Charge. |
| 12 | S&F in repairs condensing fan motor of capacity 1.5/ 2.0 tonne for split type AC's single phase, AC 230 Volts, 50 Hz of original make as per existing in the machine at site complete all as specified and directed by Engineer-in-Charge. |
| 13 | S&F in repairs condensing fan DC motor for 1.5/ 2.0 tonne capacity split type AC's (for outdoor unit) of original make as per existing in the machine at site complete all as specified and directed by Engineer-in-Charge. |
| 14 | S&F in repairs fan blades (ISI Marked) of suitable size for outdoor unit of 1.5/ 2.0 tonne split type AC's complete all as specified and directed by Engineer-in-Charge. |
| 15 | M&L for reparing of PCB control card suitable for 1.5/ 2.0 tonne capacity indoor/ outdoor split type AC/ window AC, single phase and make the PCB control card functional complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for reparing of PCB control card suitable for 1.5/ 2.0 tonne capacity invertor split type AC/ window AC, single phase and make the PCB control card functional complete all as specified and directed by Engineer-in-Charge. |
| 17 | S&F in replacement PCB control card suitable for AC indoor unit 1.5/ 2.0 Tonne capacity split type AC, single phase of original make as per existing in the machine at site complete all as specified and directed by Engineer-in-Charge. |
| 18 | S&F in replacement PCB control card suitable for DC indoor unit of 1.5/ 2.0 TR capacity invertor split type AC, single phase of original make as per existing in the machine at site complete all as specified and directed by Engineer-in-Charge. |
| 19 | S&F in replacement PCB control card suitable for outdoor unit of invertor type split AC's capacity 1.5/ 2.0 Tonne of original make as per existing in the machine at site complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply only in replacement of remote suitable for 1.5/ 2.0 tonne capacity split AC of original make as per existing at site complete all as specified and directed by Engineer-in-Charge. |
| 21 | S&F in repairs capillary copper tube (ISI Marked) of split/ window type AC capacity 1.5/ 2.0 Tonne complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&F in repair condenser coil for window type/ Split AC 1.5/ 2.0 Tonne capacity of any make and size including charging of gas R-22/ R407C complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&F in repairs water tray (ISI Marked) for indoor unit of split AC of any capacity and make complete all as specified and directed by Engineer-in-Charge. |
| 24 | S&F in repairs relay of split type AC of any make and any capacity complete all as specified and directed by Engineer-in-Charge. |
| 25 | S&F in repairs thermostat suitable for any make of split/ window type AC 1.5 Tonne capacity complete all as specified and directed by Engineer-in-Charge. |
| 26 | S&F in repairs single pole contactor, suitable for split type AC of capacity 1.5/ 2.0 Tonnne complete all as specified and directed by Engineer-in-Charge. |
| 27 | M&L for finding out the leakage with the pressure test of the condenser or cooling coil of window type AC's/ split type AC's of 1.5/ 2.0 Tonne and dismantling the same for repair, re-assembling the same after repair the leakage point by brazing/ soldering with and including charging the gas R-22/ R-410a/ R-407c/ R-32 and testing the AC to the entire satisfaction of Engineer-in-Charge. |
| 28 | Supply, laying and commissioning of cable in replacement PVC sheathed cable with multistranded copper conductor of size 2.5 Sqmm, 3 Core complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F in repairs copper tube (ISI Marked) of size ⅝” or 1/2 \\"dia for any capacity of split type AC complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F in repairs copper tube (ISI Marked) of size ¼” dia for any capacity of split type AC complete all as specified and directed by Engineer-in-Charge. |
| 31 | M&L in repairs fire resistance, elastomeric nitrile rubber tubing (NBR) for pipe insulation thickness 10mm of size ⅝\\" or 1/2\\" dia of split type AC's any capacity complete all as specified and directed by Engineer-in-Charge. |
| 32 | M&L in repairs fire resistance, elastomeric nitrile rubber tubing (NBR) for pipe insulation thickness 10mm of size¼\\"dia of split type AC's any capacity complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F in repairs flexible drain pipe (PVC BRAIDED hose pipe) of size 15mm dia, for split type AC any capacity and any make complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F in repairs air filter element suitable for split type AC 1.5/ 2.0 Tonne capacity of any make complete all as specified and directed by Engineer-in-Charge. |
| 35 | S&F in repairs wall/ floor mounting bracket stand suitable for 1.5/ 2.0 Tonne capacity outdoor unit of split AC complete all as specified and directed by Engineer-in-Charge. |
| 36 | M&L for scraping and removing of old paint of MS sheet canopy and frame of condensing unit of split type air conditioner and preparation of steel surface with and including applying two coats of synthetic enamel of smoke grey color paint (Ist quality) over one coat of zinc chromate primer (spray painting shall be carried out with spray gun and compressor) complete all as specified and directed by Engineer-in-Charge. |
| 37 | S&F in repairs MCB SP 25 Amp, ‘C’ curve type, 10 KA complete all as specified and directed by Engineer-in-Charge. |
| 38 | S&F in repairs MCB SPN 25 Amp ‘C’ curve type, 230 Volts, 10 KA complete all as specified directed by Engineer-in-Charge. |
| 39 | S&F in replacement 3 pin plug top cap 15 Amp, AC, 240 Volts, 50 Hz, complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F in replacement 3 pin socket 20 Amp, AC, 240 Volts, 50 Hz for AC metal clad box complete all as specified and directed by Engineer-in-Charge. |
| 41 | Dismantling of split AC/ window AC any capacity with proper pump down from the site and diposit to MES work shop for major repair works complete all as specified and directed by Engineer-in-Charge. |
| 42 | Fixing and commisioning only of split/ window type AC capacity 1.5/ 2.0 Tonne (serviceable AC dismantled from item No. 41 above shall be reused) including testing after installation complete all as specified and directed by Engineer-in-Charge.Note:- Copper tubing if required shall be measured and paid seprately. |
| 43 | S&F in replacement voltage stabilizer of capacity 05 KVA for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-) 2.5% complete all as specified and directed by Engineer-in-Charge. |
| 44 | S&F in replacement display card of indoor unit of split AC capacity 1.5/ 2.0 Tonne of original make as per existing in the machine at site complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F in repairs L & key valve (ISI Marked) of size 5/8\\" or 1/2\\" for condenser unit split type AC 1.5/ 2.0 Tonne, proper leak check shall be carried after replacement of valve complete all as specified and directed by Engineer-in-Charge. |
| 46 | S&F in repairs L & key valve (ISI Marked) of size 1/4\\" for condenser unit split type AC 1.5/ 2.0 Tonne, proper leak check shall be carried after replacement of valve complete all as specified and directed by Engineer-in-Charge. |
| 47 | M&L for fabrication of canopy stand for outdoor split type AC unit with and including angle iron 40mm x 40mm x 6mm, with GI sheet on the top, including welding, cutting including painting and grouted in PCC (1:2:4) on roof/ floor installation at site complete all as specified and directed by Engineer-in-Charge. |
| 48 | S&F in repair contact sensor (indoor/ outdoor/ gas pipe/ temprature) suitable for existing split AC inverter type or non inverter type of capacity 1.5/ 2.0 Tonne complete all as specified and directed. |
| 49 | S&F in repairs flair nut size 5/8\\" and 1/2\\"dia for split type AC of any capacity complete all as specified and directed by Engineer-in-Charge. |
| 50 | S&F in repairs flair nut size 3/8\\" and 1/4\\" dia for split type AC of any capacity complete all as specified and directed by the Engineer-in-Charge. |
| 51 | S&F in repairs dead nut size 1/4'' dia for any capacity of split type AC complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 52 | S&F in repairs dead nut size 1/4'' dia for any capacity of split type AC complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |