| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (AF) JORHAT ON BEHALF OF PRESIDENT OF INDIA Name of Work : REPAIR AND CLEANING OF SEWAGE LINES, MANHOLES, SEPTIC TANKS MANHOLE COVERS IN OTM OF TECH AREA AT AFS UNDER GE (AF) JORHAT CONTRACT AGREEMENT NO: GE (AF)/JOR/ OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # NUMBER # NUMBER # TEXT # Srl.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P BASIC RATEIn Words Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Cleaning and de-sludging of existing septic tank / deep manhole of any depth including taking out sludge in any form alongwith all other foreign materials by mechanical equipment or mannually or by way of any other suitable means including removal of sludge and other foreign materials out of the MOD land by any mean (Working in foul condition) and making good as it is complete all as specified and as directed.Note: No extra payment shall be admissible for dewatering. |
| 3 | Cleaning manhole depth not exc. 0.50 metre by opening cover and taking out accumulated brick bats, garbage, silts or any other items, removing and carrying same to a distance exc. 50 metre but not exc. 100 metre and buried under ground (minimum 300mm below ground level) including necessary excavation of pits and returning, filling in and dressing of surplus soil ground to slope as required, re-fixing the cover after cleaning of manhole complete all as specified and as directed. |
| 4 | All as per Serial item No. 02 here-in-before but for depth of manhole exc. 0.50m and not exc. 1.00m. |
| 5 | All as per Serial item No. 02 here-in-before but for depth of manhole exc. 1.0m and not exc. 2m. |
| 6 | Cleaning gully trap (manhole type) depth not exc. 0.50 metre by opening cover and taking out accumulated night soil, sludges, brick bats or any other Items, removing and carrying same to a distance exc. 50 meter and not exc. 100 meter and buried under ground (minimum 300mm below ground level), re-fixing the cover after cleaning of gully traps including necessary excavation of pits and returning, filling in and dressing of surplus soil, ground to slope as required complete all as specified and as directed. |
| 7 | M&L for removing of small vegetation /bushes /roots/plants /grass etc from any position of bldg or for better access of manhole/septic tank /sewage line sites complete all as specified and as directed. |
| 8 | Cleaning 150mm dia bore sewage line by roding from manhole, septic tank, gully traps, etc. with rods, bamboos, rotary cleaner, etc. and well flushing with water complete all as specified and as directed. |
| 9 | Labour only for cleaning of blocked WHB, kitchen sink, water closet, etc. complete all as specified and as directed. |
| 10 | S&F as in repairs 75mm bore PVC (SWR) soil, waste and ventilating pipe, single socket in any length with rubber ring joint, fixed to walls/floor with CI clamps complete all as specified and as directed. |
| 11 | S&F as in repairs 110mm bore PVC (SWR) soil, waste and ventilating pipe single socket in any length with rubber ring joint fixed to walls/trench with CI clamps complete all as specified and as directed. |
| 12 | S&F as in repairs 75mm bore (dia) PVC (SWR) bends complete all as specified and as directed. |
| 13 | S&F as in repairs 75mm bore (dia) PVC (SWR) bends with access door complete all as specified and as directed. |
| 14 | S&F as in repairs 110mm bore (dia) PVC (SWR) bends complete all as specified and as directed. |
| 15 | S&F in repairs 110mm bore (dia) PVC (SWR) bends with access door complete all as specified and as directed . |
| 16 | S&F as in repairs 75mm bore (dia) PVC (SWR) Tee complete all as specified and as directed. |
| 17 | S&F as in repairs 75mm bore (dia) PVC (SWR) Tee with access door complete all as specified and as directed. |
| 18 | S&F as in repairs 110mm bore (dia) PVC (SWR) Tee complete all as specified and as directed. |
| 19 | S&F as in repairs 110mm bore (dia) PVC (SWR) Tee with access door complete all as specified and as directed. |
| 20 | S&F as in repairs 75mm bore (dia) PVC (SWR) vent cowl complete all as specified and as directed. |
| 21 | S&F as in repairs 75mm bore (dia) PVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified and as directed. |
| 22 | S&F as in repairs 110mm bore (dia) PVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified and as directed. |
| 23 | S&F as in repairs 75mm bore (dia) PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed . |
| 24 | S&F as in repairs 50mm bore (dia) high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches/walls complete all as specified and as directed. |
| 25 | S&F as in repairs 500 litres capacity rotational moulded polyethylene water storage tank (cylinderical vertical with closed tap), hoisted and fixed in position including taking down old unserviceable water storage tank complete all as specified and as directed. |
| 26 | All as per Serial item No. 24 here-in-before but 1000 litres capacity. |
| 27 | S&F as in repairs 20mm bore ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed, (Minimum weight 15mm-142gms/ 20mm - 210 gms/ 25mm-455gms/ 40mm - 690 gms) complete all as specified and as directed. |
| 28 | S&F as in repairs 20mm bore gun-metal, globe or gate valves with iron wheel head, screwed both ends on any pipe including necessry fittings complete all as specified and as directed. |
| 29 | S&F 32mm dia flexible PVC pipe for waste pipe designed to connect wash basin/kitchen sinks, etc. with length not less than 600mm complete all as specified and as directed . |
| 30 | S&F as in repairs waste coupling of stainless steel of suitable size for sink complete all as specified and as directed. |
| 31 | S&F as in repairs 32mm dia waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms/40mm-60gms) for WHB complete all as specified and as directed. |
| 32 | S&F as in repairs looking mirror of size 600mmx450mm, 5.5mm thick sheet glass with PVC beading all around, etc. complete all as specified and as directed. |
| 33 | S&F as in repairs brass chromium plated shower rose of size 125mm with swivel joints including fixing to 15mm dia steel pipe or union complete all as specified and as directed. |
| 34 | S&F as in repairs health faucet (ABS body) mild steel chromium plated, suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 35 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete), set in cement mortar, etc. complete all as specified and as directed. |
| 36 | M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipe of 150mm dia including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 37 | M&L 150mm salt glazed stoneware drain pipes, laid in trenches and jointed as specified complete all as specified and as directed. |
| 38 | M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipe of 110mm dia including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 39 | Excavation in trenches in soft/loose soil not exc 1.5m wide and 1.5m in depth for foundation, etc. drain, mahole not exc. 10 Sqm on plan and n. exc. 1.5m in depth and getting out soft/loose soil complete all as specified and as directed. |
| 40 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and as directed. |
| 41 | Removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point in soft/loose soil complete all as specified and as directed. |
| 42 | S&F for 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches complete all as specified and as directed. |
| 43 | Demolition of brick work, built in cement mortar including all quoins, arches, pillars, etc. of any descriptions complete all as specified and as directed. |
| 44 | M&L for brick work with sub class 'B' bricks, straight or curved on plan, exc. 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed. |
| 45 | M&L for brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:6) complete all as specified and as directed. |
| 46 | Demolition of cement concrete (unreinforced) in ground floors and pavings, etc. not exc. 15cm thickness (below or above ground level) complete all as specified and as directed. |
| 47 | M&L for 50mm thick PCC (1:2:4) type C-1 (using 20mm graded stone aggregate) as in floor, finishing even and smooth without using extra cement complete all as specified and as directed. |
| 48 | M&L for 75mm thick flooring as in plinth protection in plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate), finished even and smooth without using extra cement complete all as specified and directed. |
| 49 | M&L for chequered tiles of size 300x300x20mm thick as on floors, set and jointed in neat cement slurry and grey cement and pigment, over and including screed bed of 20mm thick in cement mortar (1:4) as on path, etc. complete all as specified and as directed. |
| 50 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block, M-35 grade with approved colour, design & pattern as on footparth, parks,lawns, drive ways or light traffic parking, etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & patternover and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer throughvibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extrasand complete all as specified and as directed. |
| 51 | M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggegate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 52 | Forming contraction (Dummy) joints 65mm (deep) x 10mm (wide), filled with sealing compound complete all as specified and as directed. |
| 53 | Taking down cement plaster including racking out joints, hacking for key and scrubbing down with water complete all as specified and as directed. |
| 54 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces of walls in cement mortar (1:4) and finished surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 55 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces of walls in cement mortar (1:6) and finished surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 56 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over and including one coat of alkali resistant primer complete all as specified and as directed. |
| 57 | M&L for preperation of surfaces, plastered or unplastered after complete removal of existing treatment and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces complete all as specified and as directed. |
| 58 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over and including one coat of primer complete all as specified and as directed. |
| 59 | M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed. |
| 60 | Dismantling of damaged RCC works (cover slab of manholes, septic tank, kit slab or similar articles) of any descriptions and any positions, not otherwise specifically provided for complete all as specified and as directed. |
| 61 | M&L for RCC (1:2:4), type B-1 (using 20mm graded stone aggregate) as in cover slab for manholes, septic tanks, kit slab, pillar, columns, etc. complete all as specified and as directed. |
| 62 | Use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 63 | M&L for RCC (1:2:4), type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 64 | S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends binding with and including mild steel wire not less then 0.9mm dia or securing with clips quality conforming, etc. complete all as specified and as directed. |
| 65 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the permises complete all as specified and as directed. |
| 66 | M&L for vitrified ceramic coloured tiles of size 10mm thick (square/rectangular), area of each tile not exceeding 0.36 sqm as in floors, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and as directed. |
| 67 | M&L for glazed ceramic coloured tiles of size 350x250x7mm/450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match as on vertical surfaces such as skirting, dado, etc., over and including 10mm thick backing layer in cement mortar (1:3) on fair faces of brick work or concrete surfaces complete all as specified and as directed. |
| 68 | M&L for non skid ceramic coloured tiles of size 7 to 8mm thick (square/rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 20mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and as directed. |
| 69 | S&F as in repairs vitreous china squatting pan, ‘ORISSA’ pattern of size 580x440mm, White with 'P' or 'S' trap integral foot rest, providing joints between flush pipe and socket of WC pan (excluding flushing cistern and flush pipe), fixing with and including provision of 150mm thick lime concrete bedding including taking out unserviceable WC pan and connected items complete all as specified and as directed. |
| 70 | S&F as in repairs vitreous china wash down water closet pan (Pedestal pattern) of size 575x345x390mm, White with 'P' or 'S' trap including fixing bolts (excluding flushing cistern and flushing pipe) with plastic water closet seat, black, closed pattern with recessed bottom and over including mild steel chromium plated aluminium hanging device and including taking out old existing unserviceable WC and making good to disturbed surfaces with cement mortar (1:3) complete all as specified and as directed. |
| 71 | S&F as in repairs 10 litres capacity PVC low level syphonic action type flushing cistern, white with inlet, ball valve, float and handle including brackets and flushing pipe of 32mm dia. Cutting and pinning in ends, making good to the disturb surfaces in cement mortar (1:3) complete all as specified and as directed. |
| 72 | S&F as in repairs vitreous china wash hand basin of size 550x400mm (flat back or angle back type), white with 32mm dia brass chromium plated waste fitting, galvanised iron 'light grade' 32mm bore waste pipe, a pair of cast iron brackets duly painted/erecting stand including cutting and pinning in ends, making good to distrurbed surfaces in cement mortar (1:3) inlcuding taking down old existing unservicable wash hand basin and connected items complete all as specified and as directed. |
| 73 | S&F as in repairs vitreous china urinals, bowl type (back or corner wall type) half stall urinal complete providing and fixing plugs, bedding urinal against wall in cement mortar(1:2) securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) including waste coupling of PTMT suitable for urinals (minimum weight : 32mm- 45 gms) complete all as specified and as directed. |
| 74 | S&F as in repairs 15mm dia PVC 600mm long connection pipe with PTMT nuts of length complete all as specified and as directed. |
| 75 | S&F as in repairs water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 76 | S&F as in repairs kitchen sink with drainage board, made of stainless steel 1mm thick overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm with plugs, washers and waste pipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe complete all as specified and as directed. |
| 77 | Taking up or down 15mm bore steel tubing and connections, for re-fixing or removal from site complete all as per specified and as directed. |
| 78 | Re-fixing only 15mm bore old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) including cleaning and re-running the old screw threads as required complete all as specified and as directed.Note : Old serviceable pipes obtained under Serial item No. 76 above shall reuse. |
| 79 | Taking up or down 20mm bore steel tubing and connections, for re-fixing or removal from site complete all as per specified and as directed. |
| 80 | Re-fixing only 20mm bore old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) including cleaning and re-running the old screw threads as required complete all as specified and as directed.Note : Old serviceable pipes obtained under Serial item No. 78 above shall reuse. |
| 81 | S&F as in repair 15mm bore galvanised iron water tubes, 'medium grade' with all fittings and fixed to walls or ceilings or laid in floors complete all as specified and as directed. |
| 82 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc. 10cm girth complete all as specified and as directed. |
| 83 | S&F as in repairs 20mm bore galvanised iron water tubes, 'medium grade' with all fittings and fixed to walls or ceilings or laid in floors complete all as specified and as directed. |
| 84 | S&F as in repairs PVC 15mm dia bib cock of PTMT white colour, screwed down, high pressure with crutch or butterfly handle, screwed for iron pipe or for unions complete all as specified and as directed. |
| 85 | S&F as in repairs for PVC 15mm dia pillar cock of PTMT any colour, screwed down, high pressure with crutch or butterfly handle, screwed for iron pipe or for unions (minimum weight : 15mm - 110gms) complete all as specified and as directed. |
| 86 | S&F as in repairs for PVC 15mm dia angle/stop valve of PTMT any colour, screwed down, high pressure with crutch or butterfly handle, screwed for iron pipe or for unions (minimum weight : 15mm - 90gms) complete all as specified and as directed. |
| 87 | S&F as in repairs 15mm bore pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed. |
| 88 | S&F as in repairs 15mm bore bib taps, chromium plated, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 89 | S&F as in repairs 15mm bore stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 90 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 91 | Dismantling wrought iron or mild steel work of any description not otherwise specifically provided for complete all as specified and as directed. |
| 92 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W, Gde E-250 complete all as specified and as directed. |
| 93 | M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggegate) as in foundations, filling and mass concrete, etc. complete all as specified and as directed. |
| 94 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including 'Nainital' or similar pattern roof covering complete all as specified and as directed. |
| 95 | S&F as in repairs pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, etc. fixed with self tapping screw complete all as specified and as directed. |
| 96 | S&F as in repairs pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, etc., fixed with self tapping screw complete all as specified and as directed. |
| 97 | S&F as in repairs 0.63mm galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls, etc. with grade of zinc coating 275 complete all as specified and as directed. |
| 98 | S&F as in repairs 0.63mm galvanised, corrugated mild steel sheeting bent to curve with two corrugations side lap, fixed with coach screws and washers, in roofs, walls, etc. with grade of zinc coating 275 complete all as specified and as directed. |
| 99 | S&F as in repairs 0.63mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 100 | Taking down chowkats or frames with shutters (without taking off the shutters from the frame) of area not exc. 1.50 Sqm each complete all as specified and as directed. |
| 101 | S&F PVC solid door frame of size 50x47mm size made out of 5.0mm plain colour PVC sheet reinforced with mild steel square tube as specified and as per manufacture’s instructions complete all as specified and as directed. |
| 102 | S&F 30mm thick factory made solid panel PVC door shutter (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded palin colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on on either side and as gap insert for top rail and bottom rail. Panellining of plain colour PVC sheet to be fitted in the MS frame welded /sealded to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site as per specification and drawing complete all as specified and as directed. |
| 103 | S&F 100mm long butt hinges, \\"medium weight\\" cold rolled mild steel complete all as specified and as directed. |
| 104 | S&F 150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed. |
| 105 | S&F 150mm size extruded aluminium alloy handle, fabricated type anodised complete all as specified and as directed. |
| 106 | Taking down shutters with frames of size exc. 1.5 sqm but not exc. 4 sqm each with shutters (without taking off shutters from the frame) and refixing in the same opening complete all as specified and as directed. |
| 107 | Cutting into existing manholes for connecting new drains for 150mm inner dia pipe, making good to pipe and rendering, cutting out existing benching for and formingbranch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) smooth finished, and reforming benching as required complete all as specified and as directed. |
| 108 | M&L for endura rustic tiles of size 30cmx30cmx10mm thick, (parking tile) area of each tile as in floor, etc., set and jointed in neat cement slurry and pointed in white or colured cement to match, over and including 15mm thick bedding layer in cement mortar (1:6) as screed bed complete all as specified and as directed.NOTE : The contract sum shall be derieved by deducting the amount shown in Schedule of Credit attached to this tender from total amount of Schedule 'A'/BOQ. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |