| 1 | Demolition brickwork or stone masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified. |
| 2 | M&L for Squared rubble walling, Jodhpur type brought upto courses, well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified. |
| 3 | All as per Item Ser No 2 here in before but except stone. |
| 4 | Extra over Sl items 2 for hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm and dressing face beds and joints as specified to squared rubble walling Jodhpur type, brought upto courses complete all as specified. |
| 5 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified. |
| 6 | M&L rendering 15 mm thick in CM 1:4 including WPC on stone masonry surfaces or on other than fair faces of brick masonry finished even and smooth without using extra cement complete all as specified. |
| 7 | Cleaning of all blockages of Nahani trap/floor trap, bottle trap, gully trap, P or S traps of WCs, by removing solid/liquid or mud deposited in the trap or CI/PVC pipe line /Bends by rodding manually and removing the sludge duly covered in a hygenic manner and making the WC (Indian or European type)/WHB/Sink/Floor trap/Gully trap fully functional upto 1st Manhole,by deploying safaiwala per day and using manual/pressure cleaning pump & flexible rods and other necessary equipments to maintain internal sewage system in the area of AGE B/R Nagtalao complete all as specified.Notes:- (i) Contractor or his authorised representative collect such type of complaints from AGE B/R Nagtalao complaint cell at 9.00 AM on daily basis except sunday /Holiday. No extra payment shall be made on account of collection of complaint.(ii) The safailwala shall come on daily basis with necessary equipments as reqd to carry out the necessary complaints. Non availability of equipments in any case will not be admissible . (iii) Complaint must be completed within 24 hours without any fail otherwise recovery shall be made double the market rate to the contractor. (iv) Line cleaning upto 1st manhole to be paid for separately under separate item in the BOQ |
| 8 | Cleaning of manholes complete of any size and at any location incl taking out sludge and other material deposited in manhole and its disposal to a distance n exc. 50 M all as directed by Engr-in-Charge for depth of manholes as given below:- (a) Depth of manhole n exc 1.00 M |
| 9 | All item as per Ser No 8.00 above but depth of manhole exc 1.00 M & n exc 2.00 M |
| 10 | All item as per Ser No 8.00 above but depth of manhole exc 2.00 M & n exc 3.00 M |
| 11 | Cleaning and rodding the blocked sewage line of 150 mm dia and depth upto 1.5 m by rodding, well flushing using adequate water between successive manholes in suitable lengths by blocking the first and last manholes of sewage line and making it clear till the smooth flow of sewage line(manhole to manhole or Gully Trap to Manhole) including desludging the manholes on both ends and cleaning the line by manual or mechanical means as directed by Engr-in-Charge and removing the sludge/sewage & other deposits obtained from line cleaning out side of MoD land in covered van/trolleyfrom site including resetting the manhole cover including taking precautionary and safety measures and making the area neat and clean complete all as specified and directed. Note :- Desludging and dewatering of Manholes for the line under cleaning to be measured and paid for separately under respective items of the BOQ as per the depth of manholes. |
| 12 | All item as per Ser No 11.00 above but sewage line of 200 mm bore and depth of sewage line upto 1.50 m complete all as specified. |
| 13 | Cleaning/ taking out sludge/ mud/ silt from manhole and septic tanks of any size, depth and capacity by manually or mechanically in foul condition including dewatering septic tank and manholes when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and or buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified. Note:- Sludge/ muds/ silt including water shall be measured before taking out from manholes/ septic tank. |
| 14 | Taking out muddy/ sewage water from manholes, soakage pit/ septic tanks of any size, depth and capacity by using of mechanical sewage/ mud water disposal pump set and dispossed off muddy/ sewage water in a closed container vehicle to a distance outside MD land complete all as specified and directed by Engr-in-charge. Note:- All labour and T&P i.e. sewage water pump set, diesel, transportation of pump set from one place to other place, suction pipe, delivery pipe and manpower, prepair approach to working site/ point etc required for above work, shall be deemed included in unit rates quoted by the contractor and nothing extra shall be admissible on this account. |
| 15 | Removing Blockage of SGSW / NP2 pipe line of any description with help of mechanically operated nozzle machine to clean sewage line block due to accumulation of sludge/ unwanted materials/etc which leads unhygeinic condition , stored sewage water/ effluent (liquid/ semi liquid) should be pumping out/ bailing out from the manholes or water inflow caused by spring or tidal or river seepage or broken water mains or drains and the like pumping out with nozzle machine/diesel driven gen set into closed containers & delivering the same outside defence land complete all as specified. |
| 16 | Checking and attending complaints of PVC/CI pipes any dia leakage from bends,clamping the vertical stacks,jointing the leakages from bends , & other fittings/fixtures which is causing obstruction to sewage/waste water flow in PVC/CI stacks including carrying out minor repairs such as replacement of jointning material, or any other repair not mentioned herein before etc to make the PVC/CI functional and leak proof to the satisfaction of the occupants/users under the jurisdiction of AGE B/R Nagtalao Note: (i) Contractor or his authorised representative collect such type of complaints from AGE B/R Nagtalao complaint cell at 8.30 AM on daily except Sunday & Holiday. No extra payment shall be made on account of collection of complaint.(ii) Complaints must be completed with in 24 hrs without any fail otherwise recovery shall be made double the market rate to the contractor. (iii) Any new items like bends , pipes ,clamps , access doors, cowl etc to be replaced if required while carrying out these complaints should be replaced under the respective schedules under the BOQ and will be paid for separatley in addition to this item. (iv) The Contractor or his authorised representative shall come on daily basis with necessary equipments as reqd to carry out the necessary complaints. Non availability of equipments in any case will not be admissible |
| 17 | Plugging minor leakages of SGSW/ RCC pipes 150 mm bore to 300 mm bore pipes by carefully detecting leakage, cleaning outer surface of pipes and plugging with cement mortar 1:2 and/ or PCC 1:2:4 Type B-1 including rubber packing as required at site all as specified and as directed by Engineer-in-charge. (Note:- Excavation, returning filling & removal of surplus soil shall be measured and paid for separately under respective Items). Note: (i) Contractor or his authorised representative collect such type of complaints from AGE B/R Nagtalao complaint cell at 8.30 AM on daily except Sunday & Holiday. No extra payment shall be made on account of collection of complaint.(ii) Complaints must be completed with in 24 hrs without any fail otherwise recovery shall be made double the market rate to the contractor. (iii) Any new items like bends , pipes ,clamps , access doors, cowl etc to be replaced if required while carrying out these complaints should be replaced under the respective schedules under the BOQ and will be paid for separatley in addition to this item. (iv) The Contractor or his authorised representative shall come on daily basis with necessary equipments as reqd to carry out the necessary complaints. Non availability of equipments in any case will not be admissible |
| 18 | Surface dressing n.exc 15cm deep including Cleaning away all grass vegetation, saplings, shrubs, brush wood under growth and roots for making approach and around septic tanks, soakwells, manholes to manholes for sewage line and removing the rubbish to a distance not exceeding 50 M and deposting complete all as specified. |
| 19 | Excavation over area in mud or liquid mud / sludge (including removing accumulated water nearby from leaking sewage piplines) not exceeding 1.50 m in depth and getting out in soft/loose soil and returning filling in soils etc after repairs of the pipe etc complete all as specified. (for repairing leaking sewage pipelines) |
| 20 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified. |
| 21 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified. |
| 22 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified. |
| 23 | Demolition and breaking up 150 mm bore drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified. |
| 24 | All as per item No 18.00 here in above but 200mm bore pipe. |
| 25 | M&L for 150 mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified. |
| 26 | M&L for 200 mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified. |
| 27 | M&L for Reinforced concrete pipes of 150 mm bore , class NP2, laid and jointed complete with collars complete all as specified. |
| 28 | M&L for Reinforced concrete pipes of 200 mm bore , class NP2, laid and jointed complete with collars complete all as specified. |
| 29 | M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) in bedding and haunching against the side of drain pipes for 150mm dia bore after they are laid and tested complete all as specified. |
| 30 | M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) in bedding and haunching against the side of drain pipes for 200mm dia bore after they are laid and tested complete all as specified. |
| 31 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified. |
| 32 | M&L cement concrete (1:2:4) type B-1 (20mm graded stone agg) as in surface channels, drain and benching complete all as specified. |
| 33 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete including forms work, moulds mitred/stopped ends etc complete all as specified. |
| 34 | M&L for cutting into existing manholes / Septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 150mm bore pipe complete all as specified. |
| 35 | All item as per Ser No 34.00 above but for 200 mm bore pipe. |
| 36 | Dismantling old u/s PVC/CI pipe i/c fittings for 75 to 100 mm dia complete all as specified |
| 37 | Dismantling old u/s PVC/CI pipe i/c fittings for 110 mm dia complete all as specified |
| 38 | Supplying and laying of 75 mm dia PVC pipes (SWR) in trenches complete all as specified. |
| 39 | Supplying and laying of 110 mm dia PVC pipes (SWR) in trenches complete all as specified. |
| 40 | Supplying and laying of 75 mm dia PVC pipes (SWR) on walls / ceiling or laying in floors complete all as specified. |
| 41 | Supplying and laying of 110 mm dia PVC pipes (SWR) on walls / ceiling or laying in floors complete all as specified. |
| 42 | S&F 75 mm bore PVC bends any radius without oval acess door |
| 43 | S&F 110 mm bore PVC bends any radius without oval acess door |
| 44 | S&F 75 mm bore PVC bends any radius with oval acess door |
| 45 | S&F 110 mm bore PVC bends any radius with oval acess door |
| 46 | S&F 110 mm PVC (SWR) junction single, (Single T) equal or unequal |
| 47 | S&F 75 mm PVC (SWR) junction single, (Single T) equal or unequal |
| 48 | S&F 110 mm PVC (SWR) reducers |
| 49 | S&F 110 mm PVC (SWR) vent Cowl |
| 50 | M&L PVC (SWR) 75 mm bore floor trap, plain with grating including jointing with solvent cement complete all as specified |
| 51 | S&F in repair Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore pipe complete all as specified.Note- The clamp should be long as to maintain gap of 75-100 mm gap between wall and Pipe. |
| 52 | S&F in repair Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100/110 mm bore pipe complete all as specified.Note- The clamp should be long as to maintain gap of 75-100 mm gap between wall and Pipe |
| 53 | Dismantling of stone cover on manhole/drain of any description complete all as specified. |
| 54 | Provide and lay Machine cut sand stone slabs of thickness 5 cm in coverstones, for covering manholes/drain . n exc 2m in length punched dressed on face and along exposed edges ,width varies from 25 cm to 35 cm complete all as specified. |
| 55 | Dismantling of SFRC cover on manhole/drain of any description complete all as specified. |
| 56 | S&F for 75mm thick steel fibre reinforced (SFRC) man hole/ drain cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard, minimum load bearing capacity 5 ton/sqm, in square, rectangular or circular shape complete all as specified. |
| 57 | S&F in repair vitreous china squating pan of 'ORISSA' pattern size 580x440mm white with intregal foot rest including provision of lime concrete bedding but excluding flushing cistern flush pipe add fixed in repairs complete all as specified. |
| 58 | S&F in repairs PVC low level flushing cistern 10 litrs capacity (white ISI marked) with inlet ball valve, float and handle, syphonic action type including brackets and flush pipe of polythelene of low or high density of PVC 32mm dia for LLFC,including PVC connection pipe 450 mm length complete all as specified. |
| 59 | M&L for Cement concrete 25mm thick 1:2:4 type B0 using 12.5mm graded stone aggregate as in levelling course of floors finished fair and even complete all as specified. |
| 60 | M&L light colour nonskid ceramic tiles 7 to 8 mm thick area exc. 0.06 but n. exc. 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in colour cement including screed bed or bedding layer 15mm thick in CM 1:6 complete all as specified. |
| 61 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 62 | M&L for glazed ceramic tiles light colour of size 450x300x6 to 7mm thick on vertical surfaces of wall set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles including 10 mm thick screed /rendering in CM 1:4 complete all as specified. |
| 63 | S&F in repair vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover white/black closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, 32 mm dia PVC flush pipe connected to water closet with inlet(measured with flushing cistern), ball valve, float and handle complete all as specified. Please Enable Macros to View BoQ information |