| 1 | Supply Laying, jointing in repair with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 35 Sqmm 3.5 core , 1100 volts, grade including taking down UNSV cable all as specified and as directed. |
| 2 | Supply Laying, jointing in repair with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 16 Sqmm 4 core , 1100 volts, grade including taking down UNSV cable all as specified and as directed. |
| 3 | Supply Laying, jointing in repair with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 16 Sqmm 2 core , 1100 volts, grade including taking down UNSV cable all as specified and as directed. |
| 4 | Supply Laying, jointing in repair with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 10 Sqmm 2 core , 1100 volts, grade including taking down UNSV cable all as specified and as directed. |
| 5 | Supply Laying, jointing in repair with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 50 Sqmm 3.5 core , 1100 volts, grade including taking down UNSV cable all as specified and as directed.Note for item no 1 to 5:-1.Contractor shall produce test certificate of XLPE cables from OEM or Authorised dealer of OEM. |
| 6 | Supply & fixing in replacement pin type insulator porcelain, vitreous, white/brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 65mm dia and 100mm height for working pressure 1100 volts grade, complete all as specified & directed. |
| 7 | Supply & fixing in replacement Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, as under: Working pressure in volts 1100 volts, Height 100mm, max dia 115mm, section of straps 31x5mm dia of bolt 14mm, complete all as specified & directed. |
| 8 | Stretching/tightening of existing ACSR conductor after loosening binding wire from insulators and removing spacers upto a level to maintain a permissible space between conductors after rebinding the conductor with insulator with 14 SWG GI wire, complete all as specified & directed. |
| 9 | Material and labour for painting of LT panel boards with the help of jet spray paints, panels out door/in door of size above 3.00 Sqmm and up to 10 Sqmm floor mounted installed at different locations including preparation of exposed surface by removing old paint from the body, cleaning the surface with thinner and applying two coats of synthetic enamelled smoke grey paint complete all as specified and directed. |
| 10 | S&F in replacement change over switch 100 Amps off load (side handle) in sheet enclosure four pole to be fixed on wall with fastner, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed. |
| 11 | S&F in replacement change over switch 200 Amps off load (side handle) in sheet enclosure four pole to be fixed on wall with fastner, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed. |
| 12 | Material & labour for painting to existing steel tubular LT poles, 09 Mtr long including cross arms, channels, angle iron support, bracings, clamps etc. with one coat of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed. |
| 13 | Supply & fixing in replacement aluminium conductor steel reinforced (ACSR) of any size for HT/LT overhead lines on steel tubular poles/PCC poles, stretching without kinks and bends including binding wire suitable cross section (but not less than 16 SWG), complete all as specified & directed. |
| 14 | M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified & directed. Please Enable Macros to View BoQ information |
| 15 | M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified & directed. Please Enable Macros to View BoQ information |