| 1 | Please Enable Macros to View BoQ information Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: AGE(I) BHALRA Name of Work : CERTAIN REPAIRS TO DRAIN, PATHS, HARD STANDINGS, FENCING, COMPOUND WALL, RETAINING WALL FOR ZONE-III TO VI DHARMUND MIL STN UNDER AGE (I) BHALRA Contract No: AGE (I)/Bhalra- /2026-27 (NIT No. 37 of 2026-27) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground. |
| 3 | Plain cement concrete type C-2(1:3:6) using 40mm graded stone agg as in foundition filling and mass concrete |
| 4 | S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire; flat iron fillets (for securing wire mesh) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165. |
| 5 | S&F in repairs galvanized two strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain-ing bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire. staples or steel pins etc as directed. (Each line wire to be measured). |
| 6 | Restraining and resecuring including making good staples etc galvanized two strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain-ing bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire. staples or steel pins etc as directed. (Each line wire to be measured). |
| 7 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and as directed by Engineer-in-charge |
| 8 | M&L for brick work of old size sub class ‘B’ bricks straight or curved on plan exceeding 6mtr mean radius built in Cement Mortar 1:6 complete all as specified. |
| 9 | M & L for walling of random rubble stone masonry uncoursed well bounded, bedded and solidly hearted built in CM 1:6. |
| 10 | Desciption as per above item no 5 but except stone |
| 11 | Pre cast cement concrete 1:3:6 Type C1 using 20 mm graded aggregate and setting in CM 1:6 concrete in joints to match as in bond stone. |
| 12 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified of random rubble walling with maximum depression on face from straight edge held against the dressed surface not exceeding 20mm lime or sand stone, complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for Plain cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregates as in copings etc. and in similar works including weathering,slightly rounded or chamfered angles and throating and necessary form works,all as specified. |
| 14 | Taking down cement plaster of any description on brick or stone walls or from concrete surface incl raking out joints, hacking for key,scrubbing down with water and removing unserviceable material outside cantt area all as specified and directed by Engr-in-Charge. |
| 15 | M&L for Rendering 15mm thick in CM 1:4 on fair faces of brick/ stone surface finished even and smooth without using extra cement etc. all as specified. (Including all necessary scaffolding lifiting arrangement for external surfaces). |
| 16 | M&L for applying two coats of cement based paint incl preparation of new plastered surface complete all as specified. |
| 17 | M&L for applying one coat of cement based paint incl preparation of old plastered surface complete all as specified. |
| 18 | Demolition of reinforced cement concrete of any description and in any position (Reinforement cut as required to facilitate demolition) |
| 19 | M&L for Pre-cast RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in cover slab fixed in position including necessary form work and set in CM 1:6 |
| 20 | M&L TMT Bars , 10mm dia over cut to length , bent to shape reqd including cranking bending and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips all as specified . |
| 21 | Dismantling and refixing in same position MS/CI steel gates/door n exc 10 Sqm after necessary repair work/welding etc to existing grills, frames, rollers, gusset plates, rails, braces, hoks, sheets, holdfast etc, complete and making good to existing surfaces complete all as directed at site. (Note : Any steel member to gate shall be measured and paid seperately) |
| 22 | M&L for one coat synthetic enamel paint on old steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surface all as specified and directed |
| 23 | M&L for two coats synthetic enamel paint on new steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surface all as specified and directed |
| 24 | Demolition of Concrete ground floors and pavings n.exc 15cm thickness(below or above ground level) complete all as specified. |
| 25 | M&L cement concrete 1:3:6, type C-1 using 20mm graded stone (machinical crushted ) including necessary formwork as in surface channel and drains complete all as specified and as directed. |
| 26 | M&L Plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base of floor or paving 75mm thick,all as specified. |
| 27 | M&L for precast chequered tiles (factory made rectified) of size tiles 300mX300mmX25mm over 20mm thick cement screed layer in cement mortar 1:4 ,top layer glazed made in grey cement and pigment in required patterns(compressive strength not less than 250 kg per Sqm) as approved by Engr-in-charge complete, all as specified. |
| 28 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; , M-35 Grade complete all as specified. Total in Figures 23 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only |